• 제목/요약/키워드: fire endurance

검색결과 37건 처리시간 0.023초

고성능 RC 기둥의 재하가열시험에 의한 내화 특성 (Properties of Fire Endurance of High Performance RC Column by Loaded Heating Test)

  • 김경민;김기훈;황인성;이재삼;이성연;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(II)
    • /
    • pp.57-60
    • /
    • 2005
  • This study discusses spalling and fire enduring performance of high performance concrete (HPC) RC column subjected to loading under heating for 3 hours. According to the test, both the plain concrete and the concrete attached with fire enduring PC panel exceed allowable temperature after 60 minutes due to the exposure of steel bar and falling off of concrete resulting from severe spalling failure. It leads to buckling of main bar and at the same time, occurrence of collapse of plain HPC column member is observed after 2 hours and 1 hour 40 minutes's exposure to fire, respectively. On the other hand, HPC applying both PP fiber of 0.1$\%$ by mass of concrete and PP fiber+lateral confinement by metal lath maintains their original cross section, which is satisfied with the 3 hours fire endurance criteria, by discharging internal vapour pressure and enhanced lateral confinement force.

  • PDF

화염에 노출된 목재 마루 시스템의 신뢰성 해석에 관한 연구 (Study on the Reliability Analysis of Wood Floor System Exposed to Fire)

  • 김광철;이전제
    • Journal of the Korean Wood Science and Technology
    • /
    • 제32권5호
    • /
    • pp.66-74
    • /
    • 2004
  • 내화 성능은 표준 화염 조건에 노출된 목구조물의 안전성 평가를 위한 중요한 기준이 된다. 내화 성능의 기준으로 여러 나라에서 지속 시간과 파괴 시까지의 시간이 사용되고 있다. 본 연구에서는 화염에 대한 신뢰성 설계의 기초 연구로서 화염에 노출된 목재 마루 시스템의 신뢰성 해석이 진행되었다. 해석은 수치 해석적 방법과 결정론적 방법 두 가지를 모두 사용하였다. 두 방법 간에는 큰 차이를 보이지 않았다. 화염에 노출된 마루시스템의 신뢰도는 부재의 변이계수에 크게 의존하였으며 부재의 강도나 하중은 신뢰도에 크게 영향하지 않았다.

$80{\sim}100MPa$급 고강도 콘크리트의 폭렬방지 (Spalling Resistance of $80{\sim}100MPa$ High Strength Concrete)

  • 허영선;배장춘;이재삼;한창평;양성환;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.481-484
    • /
    • 2006
  • This study investigates the engineering and fire endurance properties of ultra high strength concrete. The mixture proportions with water to binder ratios (W/B) of 0.15 and 0.25 consist of various adding ratios, such as 0, 0.05, 0.1, 0.15, 0.2, 0.25 and 0.3 percent respectively, of polypropylene (PP) fiber. As for the parameters of specimens, fluidity, compressive strength and unloading fire test were carried out. Test showed that an increase of fiber contents had the favorable properties in fire endurance performance; specimens in W/B 15% required 0.3vol% of PP fiber and specimens in W/B 25% needed only 0.1vol% to prevent spalling.

  • PDF

섬유를 활용한 고강도 콘크리트기둥의 폭렬제어방안 (Spalling Reduction Method of High Strength Reinforced Concrete Columns Using Fibers)

  • 유석형
    • 한국화재소방학회논문지
    • /
    • 제23권4호
    • /
    • pp.7-12
    • /
    • 2009
  • 고강도 콘크리트(HSC)는 화재 시 $100^{\circ}C$ 이상에서 부재내부의 수분 증발로 인하여 발생한 수증기가 수밀한 콘크리트에 갇혀 피복이 탈락되는 폭렬현상이 발생한다. 콘크리트의 폭렬을 제어할 수 있는 방안으로는 폴리프로필렌 섬유(PP섬유)를 혼입하는 방법이 가장 효율적인 것으로 보고되었다. 그러나 일정량 이상 PP섬유의 사용은 폭렬저감에 효과가 없으며 특히, 초고강도 콘크리트의 시공성을 저하시킬 것으로 판단된다. 따라서 본 연구에서는 콘크리트 강도 60MPa에서 최적의 PP섬유량을 도출하고 120MPa 초고강도 콘크리트에서 시공성을 확보하기 위하여 PP섬유를 대신하여 PP분말 및 폴리비닐알콜(PVA)섬유를 사용한 기둥실험체의 내화실험 및 잔존강도 실험을 수행하였다. 실험결과 60MPa 실험체에서 PP섬유 함유량이 0%에서 0.2%까지 증가 할수록 잔존 축강도비는 68%에서 85%까지 증가하였으나, PP섬유 함유량이 0.2% 이상에서는 잔존강도의 증가가 거의 나타나지 않았다. 또한, 120Mpa 실험체에서 내화성능과 시공성을 함께 고려할 경우 PVA섬유가 가장 합리적인 것으로 나타났다.

고성능 RC 기둥의 마감재 변화에 따른 폭열 및 내화특성에 관한 연구 (A Study on the Properties of Fire Endurance and Spalling of High Performance RC Column with the Finishing and Covering Material)

  • 한천구;황인성;지석원;김경민
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제10권2호
    • /
    • pp.143-152
    • /
    • 2006
  • 건축물의 초고층화에 따라 최근 고성능 콘크리트의 사용이 증가하고 있다. 이러한 고성능 콘크리트는 고강도, 고유동, 고내구성 등 다양한 성능을 발휘하지만, 화재시 폭열에는 약한 것으로 알려져 있다. 본 연구는 PP섬유 혼입 및 마감재 변화에 따른 고성능 RC 기둥의 폭열방지 성능을 검토한 것이다. 실험결과 내화시험 후 폭열특성으로, 먼저 플레인의 경우 심한 파괴 폭열과 함께 철근이 노출됐고 내화뿜칠로 마감한 고성능 콘크리트는 내부 수분의 영향으로 플레인보다 더욱 심한 폭열을 나타냈다. 또한, 마감재 변화에 따른 시험체의 폭열특성으로는 내화도료로 마감한 경우가 가장 우수한 폭열방지 효과를 나타냈으며 폴리프로필렌 섬유를 0.1%혼입한 콘크리트는 3시간 가력 내화시험 후 가장 안전한 폭열방지 성능을 입증하였다.

Numerical study on the post-earthquake fire behavior of intermediate steel moment frames

  • Parvizizadeh, Shayan;Kazemi, Mohammad Taghi
    • Earthquakes and Structures
    • /
    • 제22권2호
    • /
    • pp.137-145
    • /
    • 2022
  • As steel is highly sensitive to temperature variations, fire exposure is more destructive in the case of steel structures in comparison to the concrete ones. The performance of an intermediate three-story steel moment frame with 4 spans was studied under the service load, thermal load and post-earthquake fire in this paper. Also, the effects of passive fire-protection materials such as ordinary cement-based and fire-retardant coatings were investigated. To model and analyze the structure; Abaqus software is utilized. In order to apply the earthquake effect, the push-over analysis method is employed. Changes in the stories deflection, endurance time and growth of nonlinear regions due to losses in the steel stiffness and strength, are among the issues considered in this study. As an interesting finding, the beams protected by ordinary cement-based coating could sustain the fire exposure at least for 30 minutes in all cases. The mentioned time is increased by employing a new fire-retardant protection, which could prevent significant loss in the structure resistance against fire, even after 60 minutes of exposure to fire.

철도터널 및 지하구간에서의 화재사고 위험성 분석 연구 (A study on the fire risk analysis on the railway tunnel and subway area)

  • 왕종배;홍선호;김상암;박옥정
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2003년도 추계학술대회 논문집(II)
    • /
    • pp.271-276
    • /
    • 2003
  • In this paper, various hazard factors are reviewed on the train fire accident in railway tunnel and subway. In case studies of systematic risk evaluation on the tunnel fire accident, we have learned the critical fire safety points for accident prevention and damage reduction such as fire-endurance of infrastructure, mortality of heat & toxic smoke, emergency situation control and management of escape requirements etc.. These hazard analysis study will contribute for improving the railway fire-safety and establishing the long-tenn safety management plan.

  • PDF

화재에 대한 콘크리트구조물의 안전성 해석 (A Safety Analysis on the Fire Endurance of Concrete Structures)

  • 방명석
    • 대한안전경영과학회지
    • /
    • 제13권2호
    • /
    • pp.61-66
    • /
    • 2011
  • Fire disasters have frequently happened in concrete structures, which resulted in severe structural damages and unsafety. In this case, the method which had evaluated the safety of damaged structures was often unaccepted from most of stakeholders and engineers. The objective of this study is to develope the procedure and method to be able to determine the safety. Numerical simulation was applied to produce the maximum temperature and temperature distribution. Nextly, temperature propagation analysis was performed to plot temperature gradients at each depth and location. The material strength curve versus temperature was applied to determine the safety of concrete structures damaged by fire. The maximum temperature should be calibrated considering real fire records ; magnitude, intensity, situation etc. The results shows that the selected procedure and method was applicable and practical.

고강도 인터벌 트레이닝(HIIT)이 소방공무원의 체력 및 업무능력에 미치는 영향 (Effects of a High-Intensity Interval Training Program on the Fitness and Performance of Firefighters)

  • 김철호;지창진;김상호
    • 한국화재소방학회논문지
    • /
    • 제34권2호
    • /
    • pp.97-102
    • /
    • 2020
  • 본 연구는 소방공무원 16명을 대상으로 8주간 고강도 인터벌 트레이닝(HIIT) 중 타바타(Tabta) 프로그램을 진행하였으며 자료처리는 윌콕슨 순위검증(Wilcoxon signed rank test)와 대응표본 t검정(Paired t-test)분석을 실시하였다. 체력요인 중 하버드 스텝(Harvard step, 회)은 운동 전 87.19 ± 12.33에서 운동 후 93.81 ± 13.27 (p < .009), 윗몸일으키기(회)는 운동 전 35.75 ± 10.73에서 운동 후 39.00 ± 8.80 (p < .001), 악력(kg)은 운동 전 53.35 ± 6.11에서 운동 후 55.65 ± 6.74 (p < .035)으로 각각 유의한 차이가 나타났다. 신체조성 중 체지방률(%)은 운동 전 17.69 ± 4.32에서 운동 후 15.66 ± 3.33 (p < .003), 근육량(%)은 운동 전 36.65 ± 4.38에서 운동 후 36.41 ± 4.24 (p < .043), 체중(kg)은 운동 전 75.50 ± 6.40에서 운동 후 74.24 ± 6.40 (p < .000)으로 각각 유의한 차이가 나타났다. 37층 도착시간은 운동 전 8 min 13 s ± 1 min 8 s에서 운동 후 7 min 19 s ± 1 min 6 s (p < .002) 유의하게 감소시켰다. 따라서 HIIT는 화재 및 재난상황 대비 업무능력 향상에 긍정적 영향을 미칠 것으로 판단된다.

Numerical investigation on punching shear of RC slabs exposed to fire

  • Sadaghian, Hamed;Farzam, Masood
    • Computers and Concrete
    • /
    • 제23권3호
    • /
    • pp.217-233
    • /
    • 2019
  • This paper describes the numerical modelling of an interior slab-column connection to investigate the punching shear resistance of reinforced concrete (RC) slabs under fire conditions. Parameters of the study were the fire direction, flexural reinforcement ratio, load levels, shear reinforcement and compressive strength of concrete. Moreover, the efficiency of the insulating material, gypsum, in reducing the heat transferred to the slab was assessed. Validation studies were conducted comparing the simulation results to experiments from the literature and common codes of practice. Temperature dependencies of both concrete and reinforcing steel bars were considered in thermo-mechanical analyses. Results showed that there is a slight difference in temperature endurance of various models with respect to concrete with different compressive strengths. It was also concluded that compared to a slab without gypsum, 10-mm and 20-mm thick gypsum reduce the maximum heat transferred to the slab by 45.8% and 70%, respectively. Finally, it was observed that increasing the flexural reinforcement ratio changes the failure mode from flexural punching to brittle punching in most cases.