• Title/Summary/Keyword: fire endurance

Search Result 37, Processing Time 0.024 seconds

Properties of the Spalling and Fire Resistance on the High Strength RC Column attached with the Stone Panel Using Lightweight Foamed Concrete (경량기포 콘크리트를 이용한 석재패널 부착 고강도 RC 기둥의 내화 및 폭렬특성)

  • Lee, Dong-Gyu;Beak, Dea-Hyun;Kim, Won-Ki;Jo, Yong-Beak;Han, Min-Choel;Han, Choen-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2007.11a
    • /
    • pp.19-22
    • /
    • 2007
  • This study discussed the prevention of the spalling and improvement of the fire resistance performance how to fill up lightweight foamed concrete on high strength RC column attached with the stone panel. The destructive spalling extremely occur caused by sudden high temperature and increased vapor pressure corresponding to falling the ston panel at all RC column, and the steel bar is exposed. The stone panel fall off about 30 minutes and spalling occur about 70 minutes on Plan RC column, fire endurance paint, and fire endurance mortar, so it can be confirmed that fire endurance paint and mortar, which is used as fire endurance material, are not effective. In the other side, it can be protected from fire about $120{\sim}140$ minutes when the lightweight foamed concrete is used as fire endurance material. For the weight loss after the fire test, plain is 33, fire endurance paint is 37%, and fire endurance mortar s 40.7%. And W/B 60%-3 is 53.4%, 60%-1.5 is 40.1%,65%-3 is 39.4%, and 65%-1.5% is 47.1. Overall, the weight loss of the plain is lower than that of the lightweight foamed concrete.

  • PDF

Decision of the priority of Fire Endurance and Spatting Prevention Efficiency in High Strength Concrete at High Rise Building Work (초고층 건축공사 고강도 콘크리트 골조의 내화 및 폭렬 방지성능 중요도 선정)

  • Baek, Dae-Hyun;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2008.11a
    • /
    • pp.804-807
    • /
    • 2008
  • Recently, with the increase of high rise and huge scale building construction, the use of high strength concrete has been increasing. High strength concrete has dense pore structure, which is susceptible to be damaged due to fire attack. For this, many researchers provide proper fire endurance method. In this paper, to provide the priority for selecting fire endurance method in high strength concrete execution, AHP technique is applied based on expert questionnaire. Fire endurance performance efficiency and ordinary performance efficiency was selected for level 1. Fire endurance performance efficiency had larger weight than ordinary one.

  • PDF

A Study on Fire Resisting Construction Design in Advanced Nation (선진각국의 내화설계법에 관한 연구)

  • 김화중
    • Fire Science and Engineering
    • /
    • v.2 no.2
    • /
    • pp.17-30
    • /
    • 1988
  • In Our Country, the fire safety design is done by the standard furnace fire test. This is haphazard procedure, as the standard furnace fire endurance of structural elements has little relation to the structural element endurance in an actual Compartment fire. The standard furnace fire test results, though obtained at great cost, do not contribute to the understanding of the behavior of structural elements in an elevated temperature environment and can not be applied rationally in fire safety design. The response of a steel and reinforced concrete structure in fire is a very complex problem. Therefore, in this paper is explained about tendency of study for fire safety design in advanced nations.

  • PDF

Fire Endurance Estimate of Reinforced Concrete Structure Using Nonlinear Finite Element Method (비선형 유한요소해석을 이용한 철근콘크리트 구조물의 내화성능평가)

  • Byun, Sun-Joo;Im, Jung-Soon;Hwang, Jee-Wook
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.6 no.1 s.20
    • /
    • pp.17-27
    • /
    • 2006
  • To estimate the retained strength of reinforced concrete structure after fire is very difficult because the complex behavior of structure is hard to understand during course of a fire. However, the damages which is caused by fire of the traffic facility infrastructure are enormous. Therefore the security against fire is important element that must not be overlooked. For this reason, an exact estimate method of the fire endurance is highly demanded. In this study, the validity of the nonlinear finite element method approach for the fire endurance of reinforced concrete structure is verified. The results of fire endurance estimate of underground road way by nonlinear finite element method approach are compared with those by ACI 216R-89.

The Evaluation of Fire Endurance of Glazing Systems with Automatic Sprinklers (자동 스프링클러로 보호된 창의 내화 성능 평가에 관한 연구)

  • Lee, Chang-Seop;Chang, Sok-Hwa;Kim, Hong;Jung, Ki-Chang
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1998.11a
    • /
    • pp.73-76
    • /
    • 1998
  • To use glazing systems protected by automatic sprinklers as fire barriers in building compartmentation, fire endurance tests of these systems have been performed by several research workers. Most of the tests concerned the types of glasses and sprinklers, sprinkler water flow rate, and sprinkler activation time. Horizontal side wall sprinklers and window glazing systems with a vertical center mullion were mainly applied in the tests. In the study, full-scale fire endurance tests were carried out to verify the ability of large glazing systems divided by a horizontal mullion and protected by pendent vertical sprinklers. The result shows that the protrusive length of the horizontal mullion, which is perpendicular to the glass surface, is the main parameter that determines the fire resistance rating of the systems. The mullion obstructs the water flow in the glass.

  • PDF

Properties of Fire Endurance of High Performance RC Column with Laterral Confinement Method (횡구속 방법에 따른 고성능 RC 기둥 콘크리트의 내화특성)

  • Hwang Yin Seong;Kim Ki-Hoon;Bae Yeoun Ki;Lee Bo Hyeong;Lee Jae Sam;Han Cheon Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.553-556
    • /
    • 2004
  • This paper is to investigate the spalling and fire endurance of high performance RC column member with PP fiber and lateral confinement of metal lath and non fire resistance removal type form. According to test results, combination of PP fiber and metal lath as well as use fire resistance non removal type form had favorable fire resistance by discharging internal vapour pressure and lateral confining. After fire endurance test, compressive strength decreased markedly caused by internal expansion pressure and crack. Residual strength of plain concrete was decreased to $22\%$. The use of PP fiber and lateral confinement of metal lath and non removal type form enhanced the residual strength above $40\%$. Especially, the combination of $0.1\%$ of PP fiber and lateral confinement with the level of 2.3T exhibited more than $51\%$ of residual strength. Therefore, to improve fire endurance and spalling resistance, the combination of $0.1\%$ of PP fiber and metal lath with 2.3T can be the proper measure.

  • PDF

Experimental study on cyclically-damaged steel-concrete composite joints subjected to fire

  • Ye, Zhongnan;Jiang, Shouchao;Heidarpour, Amin;Li, Yingchao;Li, Guoqiang
    • Steel and Composite Structures
    • /
    • v.30 no.4
    • /
    • pp.351-364
    • /
    • 2019
  • Earthquake and fire are both severe disasters for building structures. Since earthquake-induced damage will weaken the structure and reduce its fire endurance, it is important to investigate the behavior of structure subjected to post-earthquake fire. In this paper, steel-concrete composite beam-to-column joints were tested under fire with pre-damage caused by cyclic loads. Beforehand, three control specimens with no pre-damage were tested to capture the static, cyclic and fire-resistant performance of intact joints. Experimental data including strain, deflection and temperature recorded at several points are presented and analyzed to quantify the influence of cyclic damage on fire resistance. It is indicated that the fire endurance of damaged joints decreased with the increase of damage level, mainly due to faster heating-up rate after cyclic damage. However, cracks induced by cyclic loading in concrete are found to mitigate the concrete spalling at elevated temperatures. Moreover, the relationship between fire resistance and damage degree is revealed from experimental results, which can be applied in fire safety design and is worthwhile for further research.

Fire performance of concrete-filled steel tubular columns strengthened by CFRP

  • Tao, Zhong;Wang, Zhi-Bin;Han, Lin-Hai;Uy, Brian
    • Steel and Composite Structures
    • /
    • v.11 no.4
    • /
    • pp.307-324
    • /
    • 2011
  • With the increasing use of concrete-filled steel tubes (CFST) as structural members, there is a growing need to provide suitable measures for possible strengthening or repair of these kinds of structural elements. Fibre reinforced polymer (FRP) jacketing is a recent method and is particularly attractive in which it does not significantly increase the section size, and is relatively easy to install. Thus, it can be used to enhance strength and/or ductility of CFST members. Very little information is available on the performance of FRP-strengthened CFST members under fire conditions. This paper is an attempt to study the fire performance of CFST columns strengthened by FRP. The results of fire endurance tests on FRP-strengthened circular CFST columns are presented. Failure modes of the specimens after exposure to fire, temperatures in the cross section, axial deformation and fire resistance of the composite columns are analysed. It is demonstrated that the required fire endurance can be achieved if the strengthened composite columns are appropriately designed.

A Study on Assessment of Penetration Seals Performance of Nuclear Power Plants (원자력발전소 관통부 충전구조의 내화성능평가에 관한 연구)

  • Cho Hong-Seok;Park Jun-Hyen;Son Bong-Sae;Im Jung-Soon
    • Fire Science and Engineering
    • /
    • v.18 no.4
    • /
    • pp.93-102
    • /
    • 2004
  • The function of fire barrier penetration sealing is highly important to confine a fire propagation a fire severity within a fire area where the fire started. Especially for the penetration seals at the nuclear power plants with the long-term operated history, it is needed to make it clear that the conformance to the sealing requirements has been proven to guarantee the fire-resistive performance of fire barrier penetration parts. If there are any parts of fire barrier penetration sealing which can not meet the required rating for the fire endurance performance, the relevant parts must be modified to meet regulatory requirements. At this paper, the engineering analysis methodology was established to approximate the fire endurance rating for the fire barrier penetration seals. With this study, the method of engineering analysis to decide fire endurance rating for the fire barrier penetration seals was established and this way can be utilized to check the performance of the fire rating for the penetration seal at the domestic nuclear power plants.

Efficiency of insulation layers in fire protection of FRP-confined RC columns-numerical study

  • El-Mahdya, Osama O.;Hamdy, Gehan A.;Hisham, Mohammed
    • Structural Engineering and Mechanics
    • /
    • v.77 no.5
    • /
    • pp.673-689
    • /
    • 2021
  • This paper addresses the efficiency of thermal insulation layers applied to protect structural elements strengthened by fiber-reinforced polymers (FRP) in the case of fire event. The paper presents numerical modeling and nonlinear analysis of reinforced concrete (RC) columns externally strengthened by FRP and protected by thermal insulation layers when subjected to elevated temperature specified by standard fire tests, in order to predict their residual capacity and fire endurance. The adopted numerical approach uses commercial software includes heat transfer, variation of thermal and mechanical properties of concrete, steel reinforcement, FRP and insulation material with elevated temperature. The numerical results show good agreement with published results of full-scale fire tests. A parametric study was conducted to investigate the influence of several variables on the structural response and residual capacity of insulated FRP-confined columns loaded by service loads when exposed to fire. The residual capacity of FRP-confined RC column was affected by concrete grade and insulation material and was shown to improve substantially by increasing the concrete cover and insulation layer thickness. By increasing the VG insulation layer thickness 15, 32, 44, 57 mm, the loss in column capacity after 5 hours of fire was 30%, 13%, 7% and 5%, respectively. The obtained results demonstrate the validity of the presented approach for estimation of fire endurance and residual strength, as an alternative for fire testing, and for design of fire protection layers for FRP-confined RC columns.