• Title/Summary/Keyword: fire door

Search Result 217, Processing Time 0.024 seconds

Research and development of a three-stage door binder to improve the fire resistance of fire doors (방화문의 내화성능 향상을 위한 3단 문 결속기 연구개발)

  • Lim, Bo-Hyeok;Lee, Joo-Won;Cho, Dong-Hwan;Lee, Hae-Yeol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.157-158
    • /
    • 2023
  • Doors that are opened and closed when entering or exiting a general building are connected to the door frame and open and close. They are equipped with door locking devices of various structures, and are either locked to the door frame for the closing operation or released from the door frame for the opening and closing operation. Here, a single-stage door binding device having a door latch that is independently disposed at the center of one axis of the door is commonly used. On the other hand, if the size of the door is over a certain size or if the door is medium to large, the opening and closing operation may not be performed smoothly with only a single stage binder, or the closing state may not be achieved stably during the closing operation. In particular, in the case of the single-stage binding device provided in medium to large fire doors, the door is fixed to the door frame unstable, causing fatal errors in the fire prevention function of the fire door. Accordingly, in order to fundamentally solve these problems, we researched and developed a three-stage door binding machine that combines a top and bottom fastening structure with a single-stage fastening structure. This 3-stage door binder not only has the fire resistance performance of a fire door, but also has a T-shaped terminal in its fastening method, so if you eliminate the upper and lower fastening, it is a 1-stage binder like a regular product, but if you remove the door latch of the 1st-stage binder, it functions as an upper and lower 2-stage binder and forms a single mold. We researched and developed a three-stage door binder that can manufacture and produce three products at the same time, satisfying both product performance and price.

  • PDF

A Study on Improvement of the Quality Management for Fire Doors (방화문의 현장품질관리 개선방안에 관한 연구)

  • Choi, Dong-ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.93-94
    • /
    • 2019
  • When the fire door is recently installed in the field, there are frequent cases where the fire door is manufactured with fire door having low quality or different structure compared to the performance that the fire door producer has confirmed in the performance test or the construction specification. In order to improve the on-site quality management of the fire door, we comprehensively classify the quality management items of the fire door according to the management subject and the step by stage and set the field quality management procedure, the field quality management inspection item, regulations and standardized checklists were presented.

  • PDF

Study of evacuation fire doors in multiple facilities (다중이용시설의 피난방화문에 관한 연구)

  • Cha, Jong-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.12
    • /
    • pp.7380-7384
    • /
    • 2014
  • Evacuation fire doors were manufactured by applying phosphorescent paint to the whole fire door whose performance was already recognized, and applying heat sensitive paint around the grip. The facility was improved by the evacuation and safety functions on the fire door, which has been used as only a fire facility, and the fire door is also used as an evacuation facility. The brilliance of the evacuation safety fire door manufactured in this study passed the brilliance test of Korea Fire Institute with a performance more than the brilliance (7mcd after 60 minutes) of the existing inducement sign. During a fire, the visible area is larger than the evacuation door inducement, etc. and light preventive status in the lower part of the fire door was observed during the descent of smoke. Therefore, it is considered to extend the evacuation effective time of evacuators. In heat sensitive paint applied around the grip, a color change is observed on the fire door when approaching a certain temperature ($70^{\circ}C$). Therefore, the first disaster that evacuators can encounter on the grip of a fire door during a fire can be prevented and should be helpful in recognizing the backfiring possibility and preventing safety accidents for firefighters who must enter a fire space.

A Study on the Application of Quality Management to Fire Door Construction (방화문 시공시 현장품질관리지침 적용에 관한 연구)

  • Choi, Dong-ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.90-91
    • /
    • 2019
  • When the fire door is recently installed in the field, there are frequent cases where the fire door is manufactured with fire door having low quality or different structure compared to the performance that the fire door producer has confirmed in the performance test or the construction specification. Accordingly, on-site quality management and maintenance guideline for fire doors were presented. In this paper, we tried to explain the requirements for the construction of fire doors during the on-site quality management and maintenance guideline for fire doors presented in the study.

  • PDF

Statistical Analysis on the Structure of the Front Door in Apartment House (공동주택 세대 현관 방화문 구조에 관한 통계적 분석)

  • Shim, Han-Young;Park, Won-Jun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.23-24
    • /
    • 2021
  • Since 2011, apartment houses account for about 41% of the fires in residential facilities for the past 10 years. Fire-resistant performance of fire doors is becoming more important to prevent the spread of fire in apartment houses. This research analyzed the structure of fire door through each 10 DB based on the quality inspection report of Continuous Acquisition & Life-cycle Support(CALS) from 2016 to 2020, which passed the fire performance test based on the laws and notices of domestic fire door. Therefore, based on the results of the analysis of DB in the future, we will conduct a study on structural improvement and addition for fireproof performance improvement of fire door.

  • PDF

A Study on the Proposal of Durability and Service Life of Fire Door in apartment house (공동주택 방화문의 내구성능 및 내용연수 제안에 관한 연구)

  • Kwon, Yeong-Jin;Kim, Yun-Seong;Jin, Seung-Hyeon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.49-50
    • /
    • 2022
  • There are continuous cases of fire expansion due to fire door problems around the world, including the 2010 Shanghai Apartment Fire, the 2017 Grenfell Tower Fire in England, and the 2020 Ul-san Residential and Commercial Complex Fire. In order to prevent such fire damage, the country has strengthened the performance standards of fire doors, and recently, efforts have been made to ensure the best performance of fire doors by introducing a quality recognition system. Securing the performance of fire doors is a very important aspect. However, there is a concern that old fire doors may not function normally in the event of fire due to natural deterioration, corrosion, and damage during the use process, but countermeasures are insufficient. Therefore, from a management perspective, it is very important to maintain fire doors and secure an appropriate replacement time. Therefore, the purpose of this study is to determine whether the fire door has durability to prevent fire spread in the process of use through operation probability analysis and expert surveys, and to propose an appropriate useful life of the fire door.

  • PDF

Effect of Platform Screen Door on fire in the subway station (스크린도어가 설치된 지하철 승강장의 화재유동 전산 수치 모사를 이용한 스크린도어의 화재 영향 연구)

  • Jang, Yong-Jun;Jung, Woo-Sung;Park, Won-Hee;Kim, Hag-Beom
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1337-1345
    • /
    • 2007
  • The present study is a basic investigation for systematically proceeding disaster prevention studying the effect of platform screen door in case of fire at the subway station. In the paper, the characteristics of screen door were surveyed and described. The fully closed platform screen door and the island type of subway station were employed for simulation-study. Numerical simulations of fire driven flow at the subway station with platform screen door were performed with commercial fire CFD code. For analyzing of the effect of platform screen door, the fire simulations with and without the platform screen door were compared. For the fire location, the one is located on the platform and the other case on the railway. The Ultrafast model was taken as fire growth scenario. The maximum heat release rate was 10MW. The propagated time of the heat and smoke to stairs was within 4 minute when the fire is located on the platform. However the heat and smoke propagation was block off by screen door when the fire is located on the railway.

  • PDF

Evacuation Simulation for the Exit with a Windbreak Door in Underground Arcade (지하상가 출입구 방풍문 설치에 따른 피난안전해석)

  • Choi, Young-Sang;Jeon, Heung-Kyun;Choo, Hong-Lok
    • Fire Science and Engineering
    • /
    • v.23 no.3
    • /
    • pp.1-10
    • /
    • 2009
  • This paper presents a study on the evacuation analysis in underground arcade. In this study, the effect of the exit with a windbreak door has been investigated by using evacuation simulation program (building EXODUS). Also, the simulation has included the impact of smoke, heat and toxic gases by fire simulation program (CFAST). The results were obtained for the conditions of without and with door of the two exit with 1,088 evacuation population. As a results, for non-fire evacuation, there was only a little difference of evacuation time for both conditions. However, for fire emergency evacuation, the evacuation time for the condition with door increased more 110 seconds than for the condition without door. When the auto door not opened, the evacuation time was increased more 670 seconds than for the condition without door. Consequently, in case of fire, the automatic door should be operating by the signal of fire detector and keep open when the fire accidents. To lead the evacuees well to the escape route the luminaries for an emergency exit sign have to be reinforced to the wall and floor around the exit.

A Study on the Closing Force according to the Opening Angle of the Door in the Smoke Control System (제연구역 출입문 개방 각도에 따른 폐쇄력에 관한 연구)

  • Oh, Won-Sin;Joung, Suck-Hwan
    • Journal of the Korea Safety Management & Science
    • /
    • v.23 no.4
    • /
    • pp.43-48
    • /
    • 2021
  • In this study, the experiment was conducted on a fire door(W × H = 0.98 m × 2.19 m) installed on the vestibule. The effective leakage area for each opening angles and closing forces derived from the impulse-momentum equation was compared and analyzed with the experimental results. As a result of the experiment, the major factors affecting the door closing forces were the pressure difference and the area of the door. The difference of door closing forces between measured and calculated values by the impulse-momentum equation showed a deviation of less than ±15% at the opening angles of 5°to 10°. At the door opening angle of 2.5°, the dynamic pressure was much higher than the measured static pressure, and this pressure difference is estimated to be air resistance acting to prevent the door from being completely closed.

A Study on the Double Gap Blocking Device for the Improvement of Fire Resistance and Airtightness of Steel Door (강철재 도어의 내화, 기밀성 향상을 위한 이중틈새 차단장치에 관한 연구)

  • Lee, Joo-Won;Lim, Bo-Hyuk;Cho, Sung-Kwon;Lee, Hae-Yeol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.147-148
    • /
    • 2023
  • Steel doors, which are common in general buildings, do not seal the gap between the door and the floor, so drafts, noise, dust, and lights flow from the outside, and shielding devices are installed in various materials and methods, such as adding magnetic gate paper to the side of the door or installing a gasket under the door, but performance is limited. Accordingly, in order to fundamentally solve these problems, we researched and developed a double gap blocking device that can improve fire resistance and airtightness performance in steel doors. Unlike general products, the double gap blocking device has the advantage of maximizing airtight performance by forming an air layer in the center when the door is closed, as well as greatly improving the fire resistance performance, which is the basic performance of the fire door.

  • PDF