• Title/Summary/Keyword: filter replacement

Search Result 68, Processing Time 0.029 seconds

Performance assessment of HEPA filter to reduce internal dose against radioactive aerosol in nuclear decommissioning

  • Hee Kwon Ku;Min-Ho Lee;Hyunjin Boo;Geun-Dong Song;Deokhee Lee;Kaphyun Yoo;Byung Gi Park
    • Nuclear Engineering and Technology
    • /
    • v.55 no.5
    • /
    • pp.1830-1837
    • /
    • 2023
  • The thermal cutting of contaminated or activated metals during decommissioning nuclear power plants inevitably results in the release of radioactive aerosol. Since radioactive aerosols are pernicious particles that contribute to the internal dose of workers, air conditioning units with a HEPA filter are used to remove radioactive aerosols. However, a HEPA filter cannot be used permanently. This study evaluates the efficiency and lifetime of filters in actual metal cutting condition using a plasma arc cutter and a high-resolution aerosol detector. The number concentration and size distribution of aerosols from 6 nm to 10 ㎛ were measured on both the upstream and downstream sides of the filter. The total aerosol removal efficiency of HEPA filter satisfies the standard of removing at least 99.97% of 0.3 ㎛ airborne particles, even if the pressure drop increases due to dust feeding load. The pressure drop and particle size removal efficiency at 0.3 ㎛ of the HEPA filter were found to increase with repeated cutting experiments. By contrast, the efficiency of used HEPA filter reduced in removing nano-sized aerosols by up to 79.26%. Altogether, these results can be used to determine the performance guidance and replacement frequency of HEPA filters used in nuclear power plants.

Clinical Outcomes of a Preoperative Inferior Vena Cava Filter in Acute Venous Thromboembolism Patients Undergoing Abdominal-Pelvic Cancer or Orthopedic Surgery

  • Kim, Hakyoung;Han, Youngjin;Ko, Gi-Young;Jeong, Min-Jae;Choi, Kyunghak;Cho, Yong-Pil;Kwon, Tae-Won
    • Vascular Specialist International
    • /
    • v.34 no.4
    • /
    • pp.103-108
    • /
    • 2018
  • Purpose: Surgery is the most common risk factor for pulmonary embolism (PE) in patients with a recent venous thromboembolism (VTE). This study reviewed clinical outcomes of preoperative inferior vena cava filter (IVCF) use in patients with acute VTE during abdominal-pelvic cancer or lower extremity orthopedic surgeries. Materials and Methods: We retrospectively analyzed 122 patients with a recent VTE who underwent IVCF replacement prior to abdominal-pelvic cancer or lower extremity orthopedic surgery conducted between January 2010 and December 2016. Demographics, clinical characteristics, postoperative IVCF status, risk factors for a captured thrombus, and clinical outcomes were collected for these subjects. Results: Among the 122 study patients who were diagnosed with acute VTE in the prior 3 months and underwent preoperative IVCF replacement, 70 patients (57.4%) received abdominal-pelvic cancer surgery and 52 (42.6%) underwent lower extremity orthopedic surgery. There were no perioperative complications associated with IVCF in the study population and no cases of symptomatic PE postoperatively. A captured thrombus in the filter was identified postoperatively in 16 patients (13.1%). Logistic regression analysis indicated that postoperative anticoagulation within 48 hours significantly reduced the risk of a captured thrombus (odds ratio [OR], 0.28; 95% confidence interval [CI], 0.08-0.94; P=0.032). Conclusion: A captured thrombus in preoperative IVCF was identified postoperatively in 16 patients (13.1%). Postoperative anticoagulation within 48 hours reduces the risk of captured thrombus in these cases.

Assessment of Radiation Dose from Radioactive Wedge Filters during High-Energy X-Ray Therapy

  • Back, Geum-mun;Park, Sung Ho;Kim, Tae-Hyung
    • Progress in Medical Physics
    • /
    • v.28 no.2
    • /
    • pp.45-48
    • /
    • 2017
  • This paper evaluated the amount of radiation generated by wedge filters during radiation therapy using a high-energy linear accelerator, and the dose to the worker during wedge replacement. After 10-MV photon beam was irradiated with wedge filter, the wedge was removed from the linear accelerator, and the dose rate and energy spectrum were measured. The initial measurement was approximately 1 uSv/h, and the radiation level was reduced to 0.3 uSv/h after 6 min. The effective half-life derived from the dose rate measurement was approximately 3.5 min, and the influence of AI-28 was about 53%. From the energy spectrum measurements, a peak of 1,799 keV was measured for AI-28, while the peak for Co-58 was not measured in the control room. The peaks for Au-106 and Cd-105 were found only measurement was done without wedge removement from the linear accelerator. The additional doses received by the radiation worker during wedge replacement were estimated to be 0.08-0.4 mSv per year.

A Study on the Improvement of Image Fusion Accuracy Using Smoothing Filter-based Replacement Method (SFR기법을 이용한 영상 융합의 정확도 향상에 관한 연구)

  • Yun Kong-Hyun
    • Spatial Information Research
    • /
    • v.14 no.1 s.36
    • /
    • pp.85-94
    • /
    • 2006
  • Image fusion techniques are widely used to integrate a lower spatial resolution multispectral image with a higher spatial resolution panchromatic image. However, the existing techniques either cannot avoid distorting the image spectral properties or involve complicated and time-consuming decomposition and reconstruction processing in the case of wavelet transform-based fusion. In this study a simple spectral preserve fusion technique: the Smoothing Filter-based Replacement(SFR) is proposed based on a simplified solar radiation and land surface reflection model. By using a ratio between a higher resolution image and its low pass filtered (with a smoothing filter) image, spatial details can be injected to a co-registered lower resolution multispectral image minimizing its spectral properties and contrast. The technique can be applied to improve spatial resolution for either colour composites or individual bands. The fidelity to spectral property and the spatial quality of SFM are convincingly demonstrated by an image fusion experiment using IKONOS panchromatic and multispectral images. The visual evaluation and statistical analysis compared with other image fusion techniques confirmed that SFR is a better fusion technique for preserving spectral information.

  • PDF

An Experimental Study on the Characteristics of Electromagnetic Filter (전자기 필터의 특성에 관한 실험적 연구)

  • Lee, Geum-Yong;Lim, Seung-Cheol;Lee, Kun-Jai
    • Nuclear Engineering and Technology
    • /
    • v.25 no.1
    • /
    • pp.178-191
    • /
    • 1993
  • The electromagnetic filter has been recognized as a technological replacement for the conventional filtration systems of the nuclear power plant coolant. But, as of now there are neither clear understandings of the phenomena occurring in the electromagnetic filter nor the general theoretical analyses. These facts make the application or the electromagnetic filter to the real systems a little risky, and therefore it has not been commercialized although it shows excellent performances in such situations as the plant abnormality, where the conventional filters usually fail. This experimental study of the low power electromagnetic filter aims at the clarification of the general characteristics under varying operational parameters. Since the detailed characteristics may differ from one electromagnetic filter to another, they are considered secondary. The impurities applied are the highly magnetic magnetite (Fe$_3$O$_4$) and the diamagnetic cuprous oxide (Cu$_2$O). The empirical equations are derived from the experimental data by the regressional analyses. They are classified of three types : Efficiencies vs. Time, Efficiencies vs. Load, and Load vs. Time. The characteristics of the electromagnetic filter observed in this experiment agreed well with other related works in many aspects. Especially in this study, some assumptions and discussions including the physical deposition are combined for the explanations of the filter characteristics found in our and other experimental works.

  • PDF

Pre-study for the improvement of air filtration performance in the air handling unit of subway station (도시철도 지하역사 공기조화기의 미세먼지 저감성능 개선을 위한 사전연구)

  • Kang, Joong-Goo;Shin, Chang-Heon;Bae, Sung-Joon;Kwon, Soon-Bark;Kim, Se-Young;Han, Seok-Yoon
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.541-545
    • /
    • 2008
  • Particulate matter (PM) is one of the major indoor air pollutants especially in the subway station in Korea. In order to remove PM in the subway station, several kinds of PM removal system such as roll-filter, auto-washable air filter, demister, and electrostatic precipitator re used in the air handling unit (AHU) of subway station. However, those systems are faced to operation and maintenance problems since the filter-regeneration unit consisting of electrical or water jet parts is malfunctioned due to the high load of particulates and the filter material needs periodic replacement. In this study, we surveyed the particle removal systems in order to develop the new system of particle removing can be adopted in the current AHU of subway station.

  • PDF

Reuse Information based Thrashing Resistant Cache Management Scheme

  • Sim, Gyu Yeon;Kim, Cheol Hong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.3
    • /
    • pp.9-16
    • /
    • 2017
  • In recent computing systems, LRU replacement policy has been widely used because it can be simply implemented and applicable to most programs. However, if the working set size of the program is bigger than the actual cache size, LRU replacement policy may occur thrashing problem. Thrashing problem means that cache blocks are consistently replaced without re-referencing in the cache. This paper proposes a new cache management scheme to solve the thrashing problem in the second-level cache. The proposed scheme measures per set reuse frequency using EAF structure to find thrashing sets. When the cache miss occurs, it tests whether the address of the missed block is stored or not. If the address of the missed block is stored, it means that the recently evicted block is re-requested, so the reuse frequency is predicted high. In this case, the corresponding counter of the set is increased. When the counter value is bigger than the threshold value, we assume that the corresponding set shows high reuse frequency. The proposed scheme assigns the set with high reuse frequency to the additional small size cache to keep the blocks in the cache for a long time. Our experimental results show that the proposed scheme improves the IPC by 3.81% on average.

Sales Forecasting of Competing Durable Products : The Impact of Market Response and Replacement Demand (경쟁 환경하에서의 내구재의 판매예측에 관한 연구 : 소비자의 반응 및 제품대체에 의한 영향)

  • Park, Seong-Ki;Jun, Duk-Bin
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.16 no.1
    • /
    • pp.45-58
    • /
    • 1991
  • The importance of marketing mix variables, replacement demand, and competition in a new product growth model has been cited by many researchers. In this paper, these factors are integrated with an aim to model company sales of competing durables. Based on the most popular new product growth model, numerous extensions and incorporations of contributions from related research fields are tried. Model parameters are estimated by the Kalman filter. And, the proposed model is applied to the sales of four consumer durable goods. Empirical applications show the benefits, as well as the limitations of the proposed model.

  • PDF

Development of an Oil Mist Collector Equipped with Centrifugal De-oiling System (원심력 필터 재생기능을 갖춘 오일 미스트 여과 집진장치 개발)

  • Kim, Tae-Hyeung;Seo, Jeoung-Yoon;Ha, Hyun-Chul;Kim, Jong-Cheul;Cho, Jin-Ho
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.3
    • /
    • pp.166-175
    • /
    • 2005
  • Health effects associated with metal working fluid (MWF) exposures include dermatitis, respiratory disease, hypersensitive pneumonitis, and asthma. Frequently, occupational exposures to MWFs are controlled by ventilating an enclosure with an air cleaning unit that includes a fan preceded by various kinds of filtration. There are several kinds of air cleaning units used in machining centers. But the associated troubles have hindered from efficiently using these devices. The main problem is the relatively short period of filter replacement. The reason is that the air cleaning units usually do not have the de-oiling systems, thus leading the earlier clogging of filters and reducing the flow rate of hood. Thus, the first stage of study was conducted to overcome this problem by developing the new oil mist collector equipped with the easy de-oiling system. The principle of de-oiling is that the centrifugal force generated by spinning the drum covered by filter fabric separates oils from the filter fabric. It would be very similar to the spin-dry laundry. By adopting this de-oiling technique, the problems associated with the conventional oil mist collectors could be solved. Several tests/analyses were performed to make the lab-scale oil mist collector. The collection efficiencies and the de-oiling efficiencies of commercially available filter fabrics were tested. Subsequently, the endurance test were conducted by observing SEM photos of filter fabrics and measuring tensile strength/expansion coefficient after spinning the filter drum for 20 minutes at the different rotation speeds. By doing these experiments, the most appropriate filter fabric and rotation speed/duration were selected. Finally, the new oil mist collector was designed. In the near future, this device must be tested in the real machining center.

A Study on Operation of Sand Filters Coated with Manganese (망간사화된 모래여과지 운영에 관한 연구)

  • Jeong, Se-Chae;Ko, Su-Hyun;Kim, Jin-Keun;Yoo, Jeong-Hee
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.5
    • /
    • pp.558-562
    • /
    • 2006
  • Filtration experiments were conducted to determine the characteristics of manganese removal in filtration using 4 different filter media including sand and manganese sand(MS). Filtration velocity was 123 m/d and the flow rate was $3.9m^3/d$ per column. Duration of these experiments was about one year, and manganese dioxide accumulation, turbidity removal, manganese removal, and organic material removal were examined depending on filter media. When filter influent(residual chlorine 1.0 mg/L) with an average manganese concentration of 0.208 mg/L was fed through a filter column, the sand+MS and MS columns removed 98.9% and 99.2% of manganese respectively on an annual basis. When there is need to replace the sand filters with a MS filter to remove manganese, it was shown that the replacement of a partial sand filter with MS had adequate manganese removal.