• 제목/요약/키워드: film filter

검색결과 335건 처리시간 0.038초

WiMAX 응용을 위한 결합 공진기 기반의 PCB 내장형 평형신호 듀플렉서의 설계 (Design of PCB Embedded Balanced-to-unbalanced WiMax Duplexer Using Coupled LC Resonators)

  • 박주용;박종철;박재영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1587_1588
    • /
    • 2009
  • In this paper, PCB embedded balanced-to-unbalamced duplexer using coupled LC resonator was introduced for low cost dualband WiMax front-end-module application. In order to obtain the function of bandpass filter and balun transformer, proposed duplexer was configured by using magnetically coupled LC resonator. Out-of-band suppression was enhanced by applying two m-Derived transform circuits to obtain transmission zeros at 2GHz and 4.8GHz. In order to reduce the size of embedded duplexer, BaSrTiO3 (BST) composite high Dk RCC film was applied to improve the capacitance density. This high Dk film provided the capacitance density of 12.2 pF/mm2. The simulation results shows that fabricated duplexer had an insertion loss of 2.9dB and 5.5dB and return loss of 15dB and 16dB for 2.5GHz~2.6GHz and 3.5GHz~3.6GHz, respectively. The maximum magnitude and phase imbalance were 0.01dB and 0.17dB, and 1degree and 2degree in its passband, respectively. The out-of-band suppression was observed approximately 29dB and 40dB below 1.9GHz and over 4.5GHz, respectively. It has a volume of 6 mm $\times$ 7 mm $\times$ 0.7 mm (height).

  • PDF

유사 주기성을 이용한 PFS 펄스 신호의 동잡음 제거 (Removing the Motion Artifacts in the Pulse Signal Detected from the PFS Using the Quasi-periodicity)

  • 이한욱;전중창;정원근
    • 한국정보전자통신기술학회논문지
    • /
    • 제9권6호
    • /
    • pp.591-598
    • /
    • 2016
  • 모바일 헬스케어 환경에서는 정확한 생체 정보를 실시간으로 측정하는 것과 함께, 저전력의 장치를 설계하는 것이 무엇보다 중요한 관건이다. 본 논문에서는 저전력 특성을 갖는 피에조 필름 센서(PFS)를 이용하여 손목의 요골 동맥으로부터 심장의 동기 신호인 맥파를 측정하는 방법을 제안하였다. 생체 신호처리에 있어서 문제점은 동잡음의 존재이다. 본 연구에서는 맥파 신호의 동잡음을 제거하기 위해서 일반적으로 적용되는 참조신호를 이용한 적응 필터링 외에 펄스 신호의 유사 주기성을 이용한 주기 이동 평균 필터 방법을 추가로 적용하였다. 시물레이션 및 실험 결과 PFS 신호에 유사 주기성을 이용함으로써 적응 필터 이후에도 존재하는 동잡음을 완벽히 제거할 수 있음을 확인 하였다.

점 확산 함수 데이터베이스를 이용한 실시간 디지털 자동초점 (Real-Time Digital Auto-Focusing Using A-Priori Estimated Point Spread Functions)

  • 유윤종;이정수;신정호;백준기
    • 대한전자공학회논문지SP
    • /
    • 제43권5호
    • /
    • pp.1-11
    • /
    • 2006
  • 본 논문은 점 확산 함수 데이터베이스를 이용한 실시간 디지털 자동초점 기법을 제안한다. 제안하는 방식은 영상 입력 장치의 광학계가 갖는 점 확산 함수 정보로 구성되어 있는 데이터베이스를 사용해서 입력영상의 원하는 영역에 영상복원을 수행한 뒤, 이에 대한 복원 성능을 평가함으로써, 해당 점확산함수의 신뢰성을 검증한다. 이러한 방식으로 얻어진 점확산함수 집합으로부터 최적의 점 확산 함수를 적용하여, 전체 입력영상에 대한 복원을 수행함으로써 기존의 자동초점 기능을 대신한다. 또한 복원 영상에서 발생하는 잡음 및 링잉 효과의 억제를 위하여 적응적 링잉제거 필터를 포함한다. 이러한 방식을 기본으로 본 논문에서는 소형 카메라 모듈에서 사용할 수 있는 연산 부하가 적은 디지털 자동초점 기술을 제안한다.

휴대형 랩온어칩을 위한 집적화 광원으로의 OLED 적용 (Application of OLED as the Integrated Light source for the Portable Lab-On-a-Chip)

  • 김주환;신경식;김영민;김용국;양은경;김태송;강지윤;김상식;주병권
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 디스플레이 광소자분야
    • /
    • pp.193-197
    • /
    • 2004
  • The organic light emitting diode (OLED) is proposed as the novel source in the microchip because it has ideal merits (various wavelengths, thin-film structure and overall emitting) for the integration. In this paper, we fabricated the finger-type pin photodiodes for fluorescence detection and the advanced microchip with OLED integrated pn the microchannel. The finger-type in the diode design extended the depletion region and reduced the internal resistance about 31.2% than rectangular-type. The photodiodes had a 100pA leakage current and a 8720 sensitivity $(I_{Light}/I_{Dark})$ at -1 V bias. The interference filter with 32 layers ($SiO_2$, $TiO_2$) was directly deposited on the photodiode. The OLED was fabricated on the ITO coated glass and was bonded with LOC. The application of thin-film OLED increased the excitation efficiency and simplified the integration process extremely. The prototype device of this application had a superior sensitivity of 100nM-LOD in the fluorescence detection.

  • PDF

PCB 기판을 이용한 RF용 SAW 필터 개발 (Development of the RF SAW filters based on PCB substrate)

  • 이영진;임종인
    • 대한전자공학회논문지SD
    • /
    • 제43권11호
    • /
    • pp.8-13
    • /
    • 2006
  • 최근 RF용 탄성표면파 필터는 HTCC 패키지를 이용한 칩스케일 패키지 공법으로 제작되고 있다. 본 연구에서는 HTCC 패키지를 이용하는 대신에 BT 레진 계열의 PCB 기판을 이용하여 $1.4{\times}1.1$$2.0{\times}1.4mm$ 규격을 가지는 새로운 SAW RF 필터를 개발하였다. 본 기술을 적용하여 기존대비 약 40% 이상의 재료비 절감효과를 얻을 수 있다. 다층 PCB 기판과 $LiTaO_3$ 탄성표면파 기간간의 플립 본딩 조건을 최적화하였고, 적절한 PCB 재료선정을 통하여 PCB 기판 및 에폭시 라미네이팅 필름간의 열팽창계수 차이로 인해 발생하는 응력을 최소화시켰다. 이렇게 개발된 탄성표면파 필터는 기존의 제품에 비해 신뢰성 및 전기적 특성면에서 향상된 특성을 보였다.

복부 선자세 단순촬영시 화질과 피폭선량에 관한 연구 (A Study on the Image Quality and Patient Dose in Erect Simple Abdomen Radiography)

  • 김정민;임태랑;석전유치;앵정달야
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제21권1호
    • /
    • pp.29-34
    • /
    • 1998
  • The purpose of simple abdomen erect projection is to see the fluid level which indicates gastrointestinal ileus or free air due to perforation. we do not have to insist on low kVp technique in simple abdomen erect position as long as we can detect the fluid level and free air shadow. Therefore, the author tried to decrease patient dose by high kVp technique and to improve the image quality due to motion artifact by reduction of exposure time. [Methods] Experiment 1. * screen/film SRO1000/HRH * exposure factor : $140\;kvp{\pm}5\;kv$ with added filters, 200 mA, 0.01 sec * phantom : Acryles : 15.0 cm(equivalent to 17 cm body thickness) 17.5 cm(equivalent to 21 cm body thickness) 20.0 cm (equivalent to 25 cm body thickness) With the exposure factor for same film density($D=0.8{\pm}0.1$) and with the materials above, we tried to find out entrance skin dose and gonad dose for both male and female. Experiment 2. Burger's phantom radiography were checked to see whether there was any change of image quality according to the kVp and the added filters. Experiment 3. Using rotating meter(self made), we examined the motion artifact and the exposure time limitation. [Results and conculution] 1. Using high voltage technique of 140 kVp with added filter, Skin dose, testicle dose and ovary dose decrease to 89.3%, 47% and 71.4% respectively compare to 70 kVp technique, 2. No great changes of Burger's phantom image has detected as from 70 kVp to 140 kVp and the air hole size of Burger's phantom over 0.028 cc(Diameter 3 mm, hight 4 mm) can be distinghished. 3. 0.01 sec(1 pulse) exposure time is possible in the single phase full wave rectification that why we can quitely reduce the unsharness caused by patient's movement.

  • PDF

Study on Optical Characteristics of Nano Hollow Silica with TiO2 Shell Formation

  • Roh, Gi-Yeon;Sung, Hyeong-Seok;Lee, Yeong-Cheol;Lee, Seong-Eui
    • 한국세라믹학회지
    • /
    • 제56권1호
    • /
    • pp.98-103
    • /
    • 2019
  • Optical filters to control light wavelength of displays or cameras are fabricated by multi-layer stacking process of low and high index thin films. The process of multi-layer stacking of thin films has received much attention as an optimal process for effective manufacturing in the optical filter industry. However, multi-layer processing has disadvantages of complicated thin film process, and difficulty of precise control of film morphology and material selection, all of which are critical for transmittance and coloring effect on filters. In this study, the composite $TiO_2$, which can be used to control of UV absorption, coated on nano hollow silica sol, was synthesized as a coating material for optical filters. Furthermore, systematic analysis of the process parameters during the chemical reaction, and of the structural properties of the coating solutions was performed using SEM, TEM, XRD and photo spectrometry. From the structural analysis, we found that the 85 nm nano hollow silica with 2.5 nm $TiO_2$ shell formation was successfully synthesized at proper pH control and titanium butoxide content. Photo luminescence characteristics, excited by UV irradiation, show that stable absorption of 350 nm-light, correlated with a 3.54 eV band gap, existed for the $TiO_2$ shell-nano hollow silica reacted with 8.8 mole titanium butoxide solution. Transmittance observed on substrate of the $TiO_2$ shell-nano hollow silica showed effective absorption of 200-300 nm UV light without deterioration of visible light transparency.

전뇌(Whole Brain)치료 시 Field-in-Field Technique 적용에 관한 고찰 (A comparative study of dose distribution for whole brain with field-in-field technique)

  • 김보겸;이제희;정치훈;박흥득
    • 대한방사선치료학회지
    • /
    • 제17권1호
    • /
    • pp.9-17
    • /
    • 2005
  • 목적 : 방사선치료에 있어 치료부위내의 균등한 선량분포는 환자의 치료성적 및 장해를 좌우하는 매우 중요한 인자이다. 이러한 치료부위내의 균등한 선량분포를 얻기 위해 사용하는 여러 가지 방법 중 간단한 Field-in-Field Technique의 유용성을 평가하고 다양한 크기의 전뇌(whole brain)치료 환자에게 적용가능성을 알아보고자 한다. 대상 및 방법 : 전뇌(whole brain)의 일반적인 치료기법인 대향2문조사와 Field-in-Field Technique을 적용했을 때의 선량분포도를 비교하기 위하여 phantom(acryl 16 cm spheral phantom)을 대상으로 치료계획을 수립하였으며, 선량분포평가를 위하여 저감도필름(X-Omat V-film)과 열형광선량계(TLD)를 사용하여 측정하였다. 또한 다양한 두께의 환자20명(대, 중, 소 및 소아-각각 5명)을 대상으로 Field-in-Field Technique의 적용가능성을 평가 하였다 결과 : 전뇌(whole brain)치료에 대향2문조사와 Field-in-Field Technique을 적용한 경우 각각의 치료부위내의 선량분포 및 DVH를 비교한 결과, Field-in-Field Technique을 사용한 경우 고선량(high dose)영역을 $3{\sim}4\%$이하로 줄일 수 있었고, 저감도필름(X-Omat V-film)과 열형광선량계(TLD)에 의한 측정결과 또한 유사한 수치를 얻을 수 있었다. 이러한 Field-in-Field Technique을 다양한 두께의 환자에게 동일하게 적용해도 선량분포의 변화는 $1{\sim}2\%$로 나타났다. 결론 : 전뇌(whole brain)치료에 Field-in-Field Technique를 이용하여 치료계획을 수립하여 적용하면 치료부위내의 균등한 선량분포를 얻을 수 있으므로 추가적인 치료가 필요한 경우 선량합성이 용이하여 쉽게 치료계획을 수립할 수 있었다. 그리고 균등한 선량분포를 얻기 위해 사용하는 wedge filter 및 3D compensator 의 역할을 대체 할 수 있으며, 방사선 치료 시 고선량 영역으로 인해 발생되는 장해를 최소화할 수 있을 것으로 사료된다.

  • PDF

전해 커패시터를 제거하고 디밍이 가능한 고수명 단일단 PFC DCM 플라이백 컨버터 (Single-stage Dimmable PFC DCM Flyback Converter without Electrolytic Capacitor)

  • 진달래;김춘택;채민철;나재두;김영석
    • 전기학회논문지
    • /
    • 제62권11호
    • /
    • pp.1550-1559
    • /
    • 2013
  • Light emitting diode(LED) lighting has been applied various industry fields because of its high efficiency, low power consumption, long life time, and environment friendly characteristics. Generally, LED lighting needs a driver to maintain constant current. Most popular driver is the switching converter. In the converter, there are several electrolytic capacitors. However the lifespan of the electrolytic capacitor is much shorter than LED. Therefore the lifespan of LED lighting with electrolytic capacitor is decreased. Also, LED lighting needs dimming control because of various needs and energy saving. This paper presents the dimmable single-stage PFC DCM flyback converter without electrolytic capacitor and parallel LC resonant filter for reducing 120[Hz] ripple on the output. The type 2 controller is used to maintain constant current and the analog dimming control is used. The proposed converter is verified through simulation and experimental works.

Catalytic NiO Filter Supported on Carbon Fiber for Oxidation of Volatile Organic Compounds

  • Sim, Jong Ki;Seo, Hyun Ook;Jeong, Myung-Geun;Kim, Kwang-Dae;Kim, Young Dok;Lim, Dong Chan
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권7호
    • /
    • pp.2105-2110
    • /
    • 2013
  • Carbon-fiber-supported NiO catalytic filters for oxidation of volatile organic compounds were prepared by electroless Ni-P plating and subsequent annealing processes. Surface structure and crystallinity of NiO film on carbon fiber could be modified by post-annealing at different temperatures (500 and $650^{\circ}C$). Catalytic thermal decompositions of toluene over these catalytic filters were investigated. $500^{\circ}C$-annealed sample showed a higher catalytic reactivity toward toluene decomposition than $650^{\circ}C$-annealed one under same conditions, despite of its lower surface area and toluene adsorption capacity. X-ray diffraction and X-ray photoelectron spectroscopy studies suggest that amorphous structures of NiO on $500^{\circ}C$-annealed catalyst caused the higher reactivity for oxidation of toluene than that of $650^{\circ}C$-annealed sample with a higher crystallinity.