• Title/Summary/Keyword: fill dam

Search Result 150, Processing Time 0.034 seconds

Evaluation of Empirical Design Factors of Coarse Grained Material through Large Scale Shear Test (대형전단시험을 통한 댐제체용 조립재료의 경험적 설계정수에 대한 평가)

  • Oh, Gi-Dae;Kim, Kyoung-Yul;Lee, Dae-Soo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.777-783
    • /
    • 2006
  • The coarse grained materials are used in various construction field such as express way back fill, Dam etc. Especially, for dam construction, a huge mount of rock fill materials are needed, so around domestic stony mountains are generally developed to produce materials. Not an accurate theory, but design criteria is based on empirical factors that were constructed in advance for design of dam especially Concrete Face Rockfill Dam(CFRD). Considering the post facts, the modified design criteria are essential in the future with more theoretical and experimental ways. In this study, large scale direct shear tests are performed with various relative density conditions on coarse grained material of Yecheon area to compare test results and general CFRD design factors.

  • PDF

Behavior Analysis of Fill Dam Incorporating Aging Effects (Aging효과를 고려한 필댐의 거동분석)

  • Shin, Dong-Hoon;Park, Han-Gyu;Cho, Sung-Eun;Im, Eun-Sang
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.854-859
    • /
    • 2008
  • This study describes the aging behavior of soils and its mechanism, which have been reported in the literatures mainly by Mitchell(1986) and Schmertmann(1991). It could be known that aging of soils has both positive and negative effects on mechanical properties of soils. In order to show aging effects on dam behavior, a parametric study was carried out based considering the presence of a weak area within clay core zone of the fill dam. From the comparison of results obtained from numerical analysis and filed investigation, age-softening phenomena occurred within core zone during about 30 years after its completion.

  • PDF

A Study on Long-Term Seepage Behaviour of Fill Dam by the Monitoring Data Analysis (계측자료 분석에 의한 필댐의 장기 침투거동 연구)

  • Chung, Kyujung;Lee, Song
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.9
    • /
    • pp.15-25
    • /
    • 2010
  • The main objective of this study was to offer informations about long-term seepage behavioral characteristics and to find a leakage safety management method for Juam Dam and Imha Dam, a central cored rockfill dams in Korea by the evaluating the automatically monitored leakage data. In the water leakage monitoring of fill dam, the generation of abnormal water leakage is difficult to directly detect due to the effect of outside factors such as the component of rainfall inherent in the observation value. Therefore, conventionally estimation methods of water leakage quantity were applied by multiple regression analysis considering reservoir water level, rainfall, etc.. However, the estimated error of rainfall component is relatively big in these method. This paper identifies the seepage characteristic of each dams which is not directly affected by rainfall through the hydrograph separation analysis and 3 dimensional analytical method, and thinks a leakage management method. It was noticed that two dams had site specific seepage behaviour features and were in stable state with the decreasing leakage quantity. It was also found that hydrograph separation method might be applicable to leakage safety management method.

Study on Seepage Behavior of Concrete Faced Gravel-Fill Dam with Cracked Face Slab (차수벽에 균열이 발생한 표면차수벽형사력댐의 침투거동 연구)

  • Cho, Sung-Eun;Park, Han-Gyu;Im, Eun-Sang;Kim, Ki-Young
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.866-873
    • /
    • 2009
  • CFRD (Concrete Faced Rockfill Dam) has been world-widely constructed due to a lot of advantages compared with rockfill dam and recently, sand/gravel materials, instead of crushed rock materials, are also utilized as a main rockfill material to overcome geological and environmental problems. In this paper, the process of water infiltration into the originally unsaturated sand/gravel-fill dam is studied using two-dimensional saturated-unsaturated seepage theory. According to the results of seepage analysis, if the effective drainage zone is installed in the dam, the reservoir water infiltrate into the dam along a downward flow path towards the lower drainage area. The main body constructed with sand/gravel materials, therefore, remains unsaturated.

  • PDF

Evaluation of the Seismic Stability of Fill Dam by Shaking Table Tests (진동대 시험을 통한 Fill Dam의 내진 안정성 평가)

  • Yoon, Won-Sub;Chae, Young-Su;Park, Myeon-Gu
    • Journal of the Korean Geosynthetics Society
    • /
    • v.10 no.4
    • /
    • pp.81-92
    • /
    • 2011
  • In order to understand evaluation of the seismic stability of a fill dam, we made chambers of 1:100, 1:70, and 1:50 (the ratio of the miniature), considering the law of similarity based on drawings of three representative cross sections. And we measured an increase in acceleration, excess pore water pressure, and vertical/horizontal displacement after applying Hachinohe wave (long period), Ofunato wave (short period), and artificial wave, complying with the domestic standards, in order to evaluate the stability and interaction between the ground, the structure, and fluids based on the measurements. As a result, we could observe that displacement of the target cross section was relatively small compared to the allowed level of 30 cm, ensuring proper stability for an earthquake. Regarding the acceleration measurements, the increase rate was 20% for Hachinohe wave and Ofunato wave but 30% for the artificial wave. With respect to the excess pore water pressure, it was lower than 1 (which is the permissible ratio for liquefaction) ensuring proper stability as well.

Evaluation of Zoning Effect on Seepage Flow in CFGD using Centrifuge Modeling (원심모형시험을 이용한 단면 구획이 CFGD의 침투 거동에 미치는 영향 평가)

  • Kim, Kyeong-Hwan;Choo, Yun-Wook;Kim, Dong-Soo;Park, Han-Kyu;Shin, Dong-Hoon;Cho, Sung-Eun;Lim, Eun-Sang
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.278-287
    • /
    • 2009
  • This thesis studied effect of zoning on seepage flow in concrete faced gravel-fill dam (CFGD) designed to have selected main rockfill or gravel-fill zone, Zone 3Bs with higher permeability to enhance the safety against accidental water infiltration into the dam. For this purpose, centrifuge model tests with two cases, with and without Zone 3Bs, were performed in order to investigate the necessity and the function of Zone 3Bs. Model dams were made by soil samples with modified coefficients of permeability and concrete faced slab was simulated with aluminum alloy. Water infiltration was simulated by rising water table over cracks on the facing. Behaviors of model dams were measured by LVDTs, strain gages, pore water pressures and cameras. Form the results of centrifuge tests, it was found out that the Zone 3Bs acts as a protection of main gravel-fill zone by inducing flow paths for infiltrated water into it as well as by draining off the infiltrated water out of the dam in a short time.

  • PDF

Dynamic Analysis of 3 Different Cross-Sectional Shapes of a Fill Dam using 3D FEM Analysis (3차원 유한요소해석에 의한 필 댐의 3가지 단면 형상을 고려한 지진해석)

  • Choi, Byoungil
    • Journal of the Korean GEO-environmental Society
    • /
    • v.16 no.8
    • /
    • pp.37-43
    • /
    • 2015
  • Dam movements are identified in real-time with measuring instruments for dam maintenance. However, for dams that have aged, the measuring instruments that were installed during the dam construction are frequently malfunctioning or completely failing altogether. Precision safety diagnosis is being executed for dams that are national facilities Type 1. During the diagnosis, a safety assessment is conducted for the dam body. Normally, during the analysis of dam safety, the widest cross-section is selected and a two-dimensional numerical analysis is taken place for the cross-section. However, numerous researchers have recently looked into applying the 3-dimensional numerical analysis program developments to precisely analyze the structure of the dam, as well as the surrounding strata, and the lower dam strata. In this study, PLAXIS 3D, a geotechnical generic FEM analysis program, was used to conduct dam safety assessments for earthquakes. The following were compared and analyzed: considering the seismic properties of the dam body with all zoned structures reflected as one rock-fill zone together with the dam body, considering the dam body as the rock-fill zone and the core zone, and the numerical analysis results. Thus, the study was aimed to analyze the impact properties of seismic waves according to the different zones.

Investigation on the Field Compaction for Embankment of Fill Dam (휠댐성토의 현장다짐에 관한 연구)

  • 최진규;김문기
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.25 no.4
    • /
    • pp.69-79
    • /
    • 1983
  • The objective of this study is to analyze the present situation of compaction equipment used in the earth fill dam construction, and the compaction effects of varions types of equipment on core and pervious zones of the fill dam. The results obtained are summarized as follows; 1. Banking materials mostly used for the core zone were soils classified as CL, SC and ML, while those classified as SM, ML and SC were predominant for the pervious zone. 2. Equipments used practically in the real fields were considerably different from those specified in the designs. 3. It was found that the relationship between optimum water content and maximum dry density for both core and pervious materials showed to be linear, ranging from 10% to 25% water content. That is, ${\gamma}$dmax (core) = 2.2555-0.0284 Wopt ${\gamma}$dmax(pervious) =2.239-0.028 Wopt 4. The generalized compaction guides for all kinds of equipment and soil types consi- dered in this study may be recommended as N=8-10 T=2Ocm, N=10-12 T=3Ocm for core zone(98%) and N=6-8 T=2Ocm, N=8-10 T=3Ocm for pervious zone (95%). 5. The coefficient of permeability in the field tests showed abont 10 times as high as the laboratory test value. This large deviation, however, was due to the horizontal permeation and considered not to be significant in the light of the satisfactory compaction ratio in the field compac- tion.

  • PDF