• Title/Summary/Keyword: field measurements

Search Result 2,755, Processing Time 0.031 seconds

Magnetic Field Distributions of Superconducting MRI Magnet in Insert Dewar (Insert dewar를 이용한 초전도 MRI 마그네트의 자장분포 평가)

  • Jin, H.B.;Oh, B.H.;Kwon, Y.G.;Oh, S.S.;Cho, J.W.;Ha, D.W.;Lee, E.Y.;Ryu, K.W.;Ryu, K.S.;Hahn, I.Y.;Nah, W.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.137-140
    • /
    • 1995
  • This paper describes the test results of magnetic field distributions of superconducting MRI magnet in an insert dewar. To get a very high homogeneous magnetic field, various shim coils are installed besides the main magnet. The operating currents of each shim coils are obtained from the exact measurements of the magnetic field. In this paper, we report the test results of the magnetic field distribution measurements with various shim coils.

  • PDF

Bias Estimation of Magnetic Field Measurement by AHRS Using UKF (UKF를 사용한 AHRS의 자기장 측정 편차 추정)

  • Ko, Nak Yong;Song, Gyeongsub;Jeong, Seokki;Lee, Jong-Moo;Choi, Hyun-Taek;Moon, Yong Seon
    • Journal of Ocean Engineering and Technology
    • /
    • v.31 no.2
    • /
    • pp.177-182
    • /
    • 2017
  • This paper describes an unscented Kalman filter approach to estimate the bias in magnetic field measurements. A microelectromechanical systems attitude heading reference system (MEMS AHRS) was used to measure the magnetic field, together with the acceleration and angular rate. A magnetic field is usually used for yaw detection, while the acceleration serves to detect the roll and pitch. Magnetic field measurements are vulnerable to distortion due to hard-iron effect and soft-iron effect. The bias in the measurement accounts for the hard-iron effect, and this paper focuses on an approach to estimate this bias. The proposed method is compared with other methods through experiments that implement the navigation of an underwater robot using an AHRS and Doppler velocity log. The results verify that the compensation of the bias by the proposed method improves the navigation performance more than or comparable to the compensation by other methods.

Simultaneous Measurements of CH-OH PLIF and Stereoscopic PIV in Turbulent Premixed Flames (CH-OH PLIF와 Stereoscopic PIV동시계측에 의한 난류예혼합화염의 관찰)

  • Choi, Gyung-Min;Tanahashi, Mamoru;Miyauchi, Toshio
    • 한국연소학회:학술대회논문집
    • /
    • 2004.11a
    • /
    • pp.91-96
    • /
    • 2004
  • Simultaneous CH and OH planar laser induced fluorescence(PLIF) and stereoscopic particle image velocimetry (PIV) measurements have been developed to investigate the local flame structure of turbulent premixed flames. The developed simultaneous two radical concentrations and three component velocity measurements on a two-dimensional plane was applied for relatively high Reynolds number turbulent premixed flames in a swirl stabilized combustor. All measurements were conducted for methane-air premixed flames in the corrugated flamelets regime. Strong three-dimensional fluctuation implies that misunderstanding of the flame/turbulent interactions would be caused by the analysis of two-component velocity distribution in a cross section. Furthermore, comparisons of CH-OH PLIF and three-component velocity field show that the burned gases not always have high-speed velocity in relatively high Reynolds number turbulent premixed flame. The Reynolds number dependence of the flame front was clearly captured by the simultaneous CH-OH PLIF and stereoscopic PIV measurements.

  • PDF

A Study on the Determination of Density and Moisture Content of Asphalt Concrete Pavement and Subgrade Using Nuclear Density Meter (방사선측정치를 이용한 아스콘 포장 및 노상의 현장밀도와 함수비 측정에 관한 연구)

  • 진성기;도덕현
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.36 no.4
    • /
    • pp.103-116
    • /
    • 1994
  • The objective of this study was to determine the criteria for density and moisture content measurements made with a nuclear density meter on common materials in the construction field. The study also sought to test a full-type nuclear density meter in controlling the density of overlay layers( 2.5~5.0cm). In order to determine the accuracy and reliablility of nuclear guage measurements made on construction materials, laboratory and field tests were conducted. Wooden blocks( 65 x 45 ${\times}$ 50 cm) and a special steel compactor( 4.7kg) were constructed in order to carry out tests which were conducted on three different materials; coarse gramed soil, fine grained soil, and AC material. Throughout all laboratory and field tests, the nuclear density and moisture content were determined using Humboldt 5OOLP nuclear gauge. The tests on subgrade material entailed obtaining density measurements by means of both the sand replacement method and the nuclear density meter. The results of the sand replacement method were then compared to the readings recorded bu the meter. As in the subgrade material tests, density measurements made during AC pavement tests were also determined using the unclear meter in addition to a second means; through the core method. The meter readings and core densties were compared as was done in the tests on subgrade materials. The correlation between the results of the sand replacement test( also, the core method) and meter readings on subgrade material was then determined. Sirnilarly, the observed results were then analyzed through linear regression. The tests to determine thin-lift density by means of a full-type nuclear density meter also conducted on the overlay layers( about 4. 8cm thickness) above AC pavements at road construction sities in Korea.

  • PDF

EMC Measurements above 1 GHz Using an Offset Parabola Antenna System (옵셋 파라볼라 안테나를 이용한 1 GHz 이상에서의 전자파 적합성 평가)

  • Chung, Yeon-Choon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.10
    • /
    • pp.1184-1193
    • /
    • 2010
  • The upper frequency of international EMC regulations is being expanded above 1 GHz. Radiated emissions above 1 GHz are different from those below 1 GHz that is existing upper regulation frequency, and which have lower field strength and sharper and tilted beam-width, relatively. In this paper, an effective evaluation method to be used above 1 GHz is studied using an offset parabola antenna system having a double-ridged horn antenna as a feed. First, simple model is proposed for calculating antenna factor and field uniformity of the parabola antenna system, and then real radiated emission and radiated susceptibility measurements are performed using a constant noise emitter and the suggested antenna system. The results show that the proposed antenna system has higher gain and power efficiency, and wider field uniformity relative to a conventional double-ridged horn antenna. Therefore, it is confirmed that the proposed system can be effectively used for EMC measurements above 1 GHz.

A Study on Prediction of Ground Vibration by Near Field Blasting (발파에 의한 근거리 지중진동의 예측방법에 관한 연구)

  • Lee, Hyo;Kang, Chu-Won;Ko, Jin-Seok
    • Explosives and Blasting
    • /
    • v.29 no.2
    • /
    • pp.32-42
    • /
    • 2011
  • For blasting vibration analysis, there are mostly two methods, firstly, far field vibration analysis to estimate limit of building damage, secondly, near field subterranean vibration analysis to estimate rock damage and subterranean structure facilities. The former has been mainly used in our country and aboard, the latter is mostly analysed by using Homberg's model. In this model, basic input data are acquired in far field surface vibration. But in the consideration of the results of being conducted in this area over the past few decade, it is required that Homberg's model is modified. For the purpose of this, measurements of near field vibration were first conducted in our country. But it was only proposed the measurement method and the method of analysis or prediction was not suggested. Accordingly, in this paper, measurements of near field subterranean vibration were conducted and the method of analysis or prediction of near field subterranean vibration would be suggested.

Validation of Assessment for Mean Flow Field Using Spatial Averaging of Instantaneous ADCP Velocity Measurements (ADCP 자료의 공간평균을 이용한 평균유속장 산정에 대한 검증)

  • Kim, Dong-Su;Kang, Boo-Sik
    • Journal of Environmental Science International
    • /
    • v.20 no.1
    • /
    • pp.107-118
    • /
    • 2011
  • While the assessment of mean flow field is very important to characterize the hydrodynamic aspect of the flow regime in river, the conventional methodologies have required very time-consuming efforts and cost to obtain the mean flow field. The paper provides an efficient technique to quickly assess mean flow field by developing and applying spatial averaging method utilizing repeatedly surveyed acoustic Doppler current profiler(ADCP)'s cross-sectional measurements. ADCP has been widely used in measuring the detailed velocity and discharge in the last two decades. In order to validate the proposed spatial averaging method, the averaged velocity filed using the spatial averaging was compared with the bench-mark data computed by the time-averaging of the consistent fix-point ADCP measurement, which has been known as a valid but a bit inefficient way to obtain mean velocity field. The comparison showed a good agreement between two methods, which indicates that the spatial averaging method is able to be used as a surrogate way to assess the mean flow field. Bed shear stress distribution, which is a derived hydrodynamic quantity from the mean velocity field, was additionally computed by using both spatial and time-averaging methods, and they were compared each other so as to validate the spatial averaging method. This comparison also gave a good agreement. Therefore, such comparisons proved the validity of the spatial averaging to quickly assess mean flow field. The mean velocity field and its derived riverine quantities can be actively used for characterizing the flow dynamics as well as potentially applicable for validating numerical simulations.

Effect of Scatter ray in Outside Telecobalt-60 Field Size (코발트-60 조사야 밖의 장기에 미치는 2차선의 영향)

  • Kim, You-Hyun;Kim, Young-Whan
    • Journal of radiological science and technology
    • /
    • v.11 no.2
    • /
    • pp.65-71
    • /
    • 1988
  • Radiation dose outside the radiotherapy treatment field can be significant and therefore is of clinical interest estimating organ dose. We have made measurements of dose at distances up to 70 cm from the central axis of $5{\times}5$, $10{\times}10$, $15{\times}15$, and $25{\times}25$ cm radiation fields of Co-60 ${\gamma}-ray$, at 5 cm depth in water. Contributions to the total secondary radiation dose from water scatter, machine (collimator) scatter and leakage radiation have been seperated. We have found that the component of dose from water scatter can be described by simple exponential function of distance from the central axis of the radiation field for all field sizes. Machine scatter contributes 20 to 60% of the total secondary dose depending on field size and distance from the field. Leakage radiation contributes very little dose, but becomes the dominant componant at distance beyond 40 cm from the central axis. Then, wedges can cause a factor 2 to 3 increase in dose at any point outside the field compared with the dose when no wedge is used. Adding blocks to a treatment field can cause an increase in dose at points outside the field, but the effect is much smaller than the effect of a wedge. From the results of these measurements, doses to selected organs outside the field for specified treatment geometries were estimated, and the potential for reducing these organ doses by additional shielding was assessed.

  • PDF

Analysis of CHAMP Magnetic Anomalies for Polar Geodynamic Variations

  • Kim Hyung Rae;von Frese Ralph R.B.;Park Chan-Hong;Kim Jeong Woo
    • Korean Journal of Remote Sensing
    • /
    • v.21 no.1
    • /
    • pp.91-98
    • /
    • 2005
  • On board satellite magnetometer measures all possible magnetic components, such as the core and crustal components from the inner Earth, and magnetospheric, ionospheric and' its coupled components from the outer Earth. Due to its dipole and non-dipole features, separation of the respective component from the measurements is most difficult unless the comprehensive knowledge of each field characteristics and the consequent modeling methods are solidly constructed. Especially, regional long wavelength magnetic signals of the crust are strongly masked by the main field and dynamic external field and hence difficult to isolate in the satellite measurements. In particular, the un-modeled effects of the strong auroral external fields and the complicated behavior of the core field near the geomagnetic poles conspire to greatly reduce the crustal magnetic signal-to-noise ratio in the polar region relative to the rest of the Earth. We can, however, use spectral correlation theory to filter the static lithospheric and core field components from the dynamic external field effects that are closely related to the geomagnetic storms affecting ionospheric current disturbances. To help isolate regional lithospheric anomalies from core field components, the correlations between CHAMP magnetic anomalies and the pseudo-magnetic effects inferred from satellite gravity-derived crustal thickness variations can also be exploited, Isolation of long wavelengths resulted from the respective source is the key to understand and improve the models of the external magnetic components as well as of the lower crustal structures. We expect to model the external field variations that might also be affected by a sudden upheaval like tsunami by using our algorithm after isolating any internal field components.

Irrigation water temperature and cold water damage of paddy (관개수온과 벼의 냉수피해)

  • 정상옥;오창준
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.14-21
    • /
    • 1998
  • In 1996, a cold-water damage occured in the paddy field at downstream of the Unmoon dam. To study the cause and the preventive measures of the cold-water damage a field study was performed during the growing season of 1997. Field measurements such as water temperatures at reservoir, irrigation canal and in the paddy field were made. As a result, there was no cold-water damage due to the right irrigation water management practice in 1997. The cold-water damage is passible to happen, however, and the preventive measures were provided.

  • PDF