• Title/Summary/Keyword: field cooling

Search Result 642, Processing Time 0.029 seconds

Note on the Development of Ballast Water Shifting System for Solar Tracking of the Floating Photovoltaic Plant (밸러스트 수 이동으로 태양을 추적하는 부유식 태양광 발전시스템 개발)

  • Oh, Jungkeun;Kim, Jun-Ho;Kim, Seung-Sup;Kim, Hyochul;Lew, Jae-Moon
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.53 no.4
    • /
    • pp.290-299
    • /
    • 2016
  • The most powerful energy resource in nature is solar energy which becomes directly converted to electric power in worldwide. Most of the photovoltaic power plants are commonly installed on sunny side of the ground. Thus the installation of photovoltaic power plant could produce an unexpected adverse effect by sacrificing the productivity from green field or forest. To avoid these adverse effect floating photovoltaic plant has been devised and installed on inland reservoir. The photovoltaic plant could utilize ignored water surface without sacrificing the productivity of the ground. Additionally the photovoltaic efficiency has been reenforced by the cooling effect induced by the circulating air flow from water surface. The floating photovoltaic plant could be furnished solar tracking ability by tilting the system operated with the aid of the ballast system. This report is provided to introduce the design of the floating structure with solar panel which furnished solar tracking ability with the aid of ballast system.

Efficiency and Comfort Properties of Silicon Solar Cell Applied Air Circulation Jacket according to the Incident Angle of Sunlight (실리콘 태양전지를 활용한 공기순환 의복의 태양광 입사각에 따른 효율성 및 쾌적성평가)

  • Lee, Ji-Yeon;Cho, A-Ra;Jung, Ye-Lee;Kim, Eun-Ae
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.33 no.11
    • /
    • pp.1806-1816
    • /
    • 2009
  • This study analyzes the efficiency of a solar cell attached to an air circulation jacket. A commercially available silicon solar panel was selected and attached at four spots where the body angle was $40-60^{\circ}$ and voltage ($V_{oc}$, V), current ($I_{sc}$, A), and output power (P, W) were measured to determine the efficiency. The solar panel was applied to the outer jacket that operates with two fans to increase the convection that lowers the body temperature. The heavy work of standing, walking, and sweeping of a street sweeper was simulated in the field test. The microclimate within the jacket (with or without a fan) was measured and the subjective thermal, humidity, and comfort sensations were surveyed. SPSS 12.0 statistical package was used for a t-test and Wilcoxon signed-rank test. The results show that the highest efficiency of the solar cell was at the incident angle of $60^{\circ}$ in terms of voltage, current and output power distribution. The microclimate temperature of the air circulation jacket decreased significantly with the high power of the fan and subjects felt cooler than the jacket with a fan at the incident angle of $60^{\circ}$. Air circulation jackets operated by a silicon solar panel showed a significant cooling effect on the wearers.

Synthesis and characterization of potassium titanate whisker by flux method (융제법을 이용한 티탄산칼륨 휘스커의 합성과 특성)

  • Choi, Yeon-Bin;Son, Jeong-hun;Bae, Dong Sik
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.26 no.4
    • /
    • pp.150-154
    • /
    • 2016
  • Method for synthesizing a $K_2Ti_6O_{13}$ whisker is a solid-state method, hydrothermal synthesis method, calcination method, flux method, slow-cooling method, melting method, kneading-drying-calcination method, sol-gel method etc. $K_2Ti_6O_{13}$ whisker have been synthesized by a flux method. The average size and distribution of the synthesized $K_2Ti_6O_{13}$ whisker can be controlled by a kind of potassium precursors and reaction temperature and time. The average size of the synthesized $K_2Ti_6O_{13}$ whisker was about in the size range of 500 nm to $2{\mu}m$. The effect of synthesis parameters, such as the molar ratio of KOH to $TiO_2$, pH, reaction temperature and time, are discussed. The synthesized $K_2Ti_6O_{13}$ whisker were characterized by x-ray diffraction analysis (XRD), field emission scanning electron microscopy (FE-SEM).

A Study on Winter Season Measurement Results to cope with Dynamic Pricing for the VRF System

  • Kim, Hwan-yong;Kim, Min-seok;Lee, Je-hyeon;Song, Young-hak
    • Architectural research
    • /
    • v.17 no.3
    • /
    • pp.109-115
    • /
    • 2015
  • The dynamic pricing of electricity, where the electricity rate increases in a time zone with a high demand for electricity is typically applied to a building whose power reception capacity is greater than a certain size. This includes the time of use(TOU) electricity pricing in Korea which can induce the effect of reducing the power demand of a building. Meanwhile, a VRF (Variable Refrigerant Flow) system that uses electricity is regarded as one of the typical heating and cooling systems along with central air conditioning (central HVAC) for its easy operation and application to the building. Thus, to reduce power energy and operating costs of a building in which the TOU and VRF systems are applied simultaneously, we suggested a control for changing the indoor temperature setting within the thermal comfort range or limiting the rotational speed of an inverter compressor. In this study, to describe the features of the above-mentioned control and verify its effects, we evaluated the results obtained from the analysis of its operation data. Through the actual measurements in winter operations for 73 days since mid- December 2014, we confirmed a reduction of 10.9% in power energy consumption and 12.2% in operating costs by the new control. Also, a reduction of 13.3% in power energy consumption was identified through a regression analysis.

Expert opinions on improvement of current food code related to hygiene management standards for cooked foods in restaurants (현행 식품접객업소 조리식품 위생관리 기준 보완에 관한 전문가 의견)

  • Ju, Seyoung;Kawk, Hyoseon;Hong, Wansoo;Kwak, Tongkyung;Chang, Hyeja
    • Journal of Nutrition and Health
    • /
    • v.49 no.3
    • /
    • pp.201-212
    • /
    • 2016
  • Purpose: Needs for reevaluation of food code standards and regulations for cooked foods produced in restaurants and institutional foodservice to minimize risk factors leading to foodborne outbreaks are on the rise. The purpose of the study was to propose updated standards for cooked foods of restaurants by testing whether or not experts agree to include them as a standard. Methods: Qualitative and quantitative research methods were applied via a survey by email and workshop hold for experts panel discussions. Results: Seven newly proposed standards were selected as follows: (1) sanitizing vegetables and fruits with no heating process after washing, (2) rapid cooling of cooked foods after heating process, (3) monitoring cooking temperatures, (4) minimum 2 hours holding after cooking for temperature control of safety (TCS) foods without temperature control, (5) banning practices for workers such as bare hands handling of ready-to-eat foods, (6) maintaining cleanliness of food contact surfaces for disposable products, and (7) cold holding standards for sushi. Conclusion: The proposed proposal can be utilized as control measures for preventing foodborne illness in restaurants. However, a feasibility study should be conducted to test whether they are applicable to the field of restaurant operation.

A Study on the Properties of Substituted Ferrite (Fe-Al-Ga-Si) (치환형 Ferrite (Fe-Al-Ga-Si)의 특성 연구)

  • Choi, Seung-Han
    • Korean Journal of Materials Research
    • /
    • v.21 no.8
    • /
    • pp.439-443
    • /
    • 2011
  • The crystal structure and magnetic properties of a new solid solution type ferrite $(Fe_2O_3)_5-(Al_2O_3)_{3.4}-(Ga_2O_3)_{0.6}-SiO$ were investigated using X-ray diffraction and M$\"{o}$ssbauer spectroscopy. The results of the X-ray diffraction pattern indicated that the crystal structure of the sample appears to be a cubic spinel type structure. The lattice constant (a = 8.317 ${\AA}$) decreases slightly with the substitution of $Ga_2O_3$ even though the ionic radii of the Ga ions are larger than that of the Al ions. The results can be attributed to a higher degree of covalency in the Ga-O bonds than in the Al-O and Fe-O bonds, which can also be explained using the observed M$\"{o}$ssbauer parameters, which are the magnetic hyperfine field, isomer shift, and quadrupole splitting. The drastic change in the magnetic structure according to the Ga ion substitution in the $ (Fe_2O_3)_5(Al_2O_3)_{4-x}(Ga_2O_3)_xSiO$ system and the low temperature variation have been studied through a M$\"{o}$ssbauer spectroscopy. The M$\"{o}$ssbauer spectrum at room temperature shows the superpositions of two Zeeman patterns and a strong doublet. It shows significant departures from the prototypical ferrite and is comparable with the diluted ferrite. The doublet of spectrum at room temperature appears to originate from superparamagnetic clusters and also the asymmetry of the doublet appears to be caused by the preferred orientation of the crystallites. The M$\"{o}$ssbauer spectra below room temperature show various complicated patterns, which can be explained by the freezing of the superparamagnetic clusters. On cooling, the magnetic states of the sample were various and multi critical.

Measurement of Environmental Tobacco Smoke in the Air of Offices in Urban Areas - Focusing on the Impact of Smoking on the Concentrations of Suspended Particles - (도시지역 사무실내 공기 중 환경담배연기의 측정 - 흡연이 부유먼지 농도에 미치는 영향을 중심으로 -)

  • Baek Sung-Ok;Park Sang-Kon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.6
    • /
    • pp.715-727
    • /
    • 2004
  • This study was carried out to evaluate non-smoker's exposure levels to environmental tobacco smoke (ETS) in the air of offices in urban areas. A total of 65 offices were selected from two large cities, i.e. Daegu and Daejeon. The field sampling was conducted repeatedly in summer (1999) and winter (1999~2000). The measured ETS markers included respirable suspended particles (RSP as PM$_{40}$ ), vapor and particulate phase ETS markers, including nicotine, 3-ethnyl pyridine (3-EP), ultraviolet absorbing particulate matter (UVPM), fluorescing particulate matter (FPM), and solanseol in ETS particles (SolPM). RSP was measured gravimetrically by a microbalance. The particle samples were then used for the determination of particulate ETS markers by HPLC, while vapor phase markers determined by GC/NPD. The analytical methods were validated for repeatability, linearity, detection limits, and duplication precision. The concentrations of RSP and other ETS markers were significantly higher in smoking offices than non-smoking offices. Despite the similar smoking strength in each office for different seasons, the concentration levels of ETS components appeared to be higher in winter than summer. The contributions of ETS to RSP concentrations based on SolPM, FPM, and UVPM methods were estimated to be in the range of 15.2 ~ 25.3% in smoking offices, whereas 2.4 ~ 15.9% in non-smoking offices. The cooling and heating types did not affect significantly the concentrations of RSP and other ETS markers. Finally, further research issues were suggested to obtain more scientific information on the non-smoker's exposure to ETS with respect to the frame of risk assessment..

Defect Detection of Carbon Steel Pipe Weld Area using Infrared Thermography Camera (적외선 열화상 카메라를 이용한 탄소강관 용접부 결함검출)

  • Kwon, DaeJu;Jung, NaRa;Kim, JaeYeol
    • Tribology and Lubricants
    • /
    • v.30 no.2
    • /
    • pp.124-129
    • /
    • 2014
  • The piping system accounts for a large portion of the machinery structure of a plant, and is considered as a very important mechanical structure for plant safety. Accordingly, it is used in most energy plants in the nuclear, gas, and heavy chemical industries. In particular, the piping system for a nuclear plant is generally complicated and uses the reactor and its cooling system. The piping equipment is exposed to diverse loads such as weight, temperature, pressure, and seismic load from pipes and fluids, and is used to transfer steam, oil, and gas. In ultrasound infrared thermography, which is an active thermography technology, a 15-100 kHz ultrasound wave is applied to the subject, and the resulting heat from the defective parts is measured using a thermography camera. Because this technique can inspect a large area simultaneously and detect defects such as cracks and delamination in real time, it is used to detect defects in the new and renewable energy, car, and aerospace industries, and recently, in piping defect detection. In this study, ultrasound infrared thermography is used to detect information for the diagnosis of nuclear equipment and structures. Test specimens are prepared with piping materials for nuclear plants, and the optimally designed ultrasound horn and ultrasound vibration system is used to determine damages on nuclear plant piping and detect defects. Additionally, the detected images are used to improve the reliability of the surface and internal defect detection for nuclear piping materials, and their field applicability and reliability is verified.

Numerical Simulation considering Latent Heat Effect for Laser Cladding Process (잠열을 고려한 레이저 클래딩 공정의 수치해석)

  • Zhao, Guiping;Si, Ho-Mun;Jo, Jong-Du;Kim, Jae-Do
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.10
    • /
    • pp.134-147
    • /
    • 2001
  • Laser cladding process accompanies phase transformations from melting (on heating) through solidifying (on cooling) at the same time within a small material volume and to final solid phase. The phase transformations are not reversible, but an irreversible thermodynamic process; they accompany either absorption or release of thermal energy (referred to latent heat) during transformation. Yet, most analyses on materials processed by laser as a heat source have been performed on models of neglecting the latent heat in the process and those did not Justify the simplification. With literatures on the laser material process, we have not place an answer to how little the assumption affects on analyses. This led us to our current study: the effects of latent heat on thermo-mechanical analysis. To this end, we developed a fairly accurate program accommodating an algorithm for enforcing the latent heat whenever necessary and ran it combining with ABAQUS$^{TM}$. The simulation techniques we used in this study were verified by directly comparing our prediction with experimental publications elsewhere; our numerical results agreed accurately with the experiments. On the effects of the latent heat, we performed two alternatives about considering the latent heat in analysis, and compared each other. As a result, we found that more accurate conclusions might come out when considering the latent heat in process analyses.s.

  • PDF

Design of a IMVA Single-Phase HTS Power Transformer

  • Kim, Sung-Hoon;Kim, Woo-Seok;Park, Chan-Bae;Hahn, Song-yop;Park, Kyeong-Dal;Joo, Hyeong-Gil;Hong, Gye-Won
    • Progress in Superconductivity
    • /
    • v.4 no.1
    • /
    • pp.86-89
    • /
    • 2002
  • In this paper, the design of a IMVA single-phase high temperature superconducting(HTS) power transformer with BSCCO-2223 HTS tapes is presented. The rated voltages of each sides of the transformer are 22.9 ㎸ and 6.6 ㎸, respectively The winding of 1MVA HTS transformer is consisted of double pancake type HTS windings, which have advantages of insulation and distribution of high voltage, and are cooled by subcooled liquid nitrogen of 65K. Four HTS tapes were wound in parallel for the windings of low voltage side and the four parallel conductors are transposed. The design of 1MVA HTS transformer, a shell type core made of laminated silicon steel plate is chosen, and the core is separated with the windings by a cryostat with a room temperature bore. The cryostat made of non-magnetic and non-conducting material and a liquid nitrogen sub-cooling system is designed in order to maintain the coolant's temperature of 65K. For electromagnetic analysis of 1MVA HTS transformer, a finite element method of an axis of symmetry is used. The maximum perpendicular component of magnetic flux density of pancake windings is about 0.15T. And through analyzing the magnetic field distribution, an optimal winding arrangement of 1MVA HTS transformer is obtained.

  • PDF