• Title/Summary/Keyword: field conditions

Search Result 6,820, Processing Time 0.04 seconds

Radar Remote Sensing of Soil Moisture and Surface Roughness for Vegetated Surfaces

  • Oh, Yi-Sok
    • Korean Journal of Remote Sensing
    • /
    • v.24 no.5
    • /
    • pp.427-436
    • /
    • 2008
  • This paper presents radar remote sensing of soil moisture and surface roughness for vegetated surfaces. A precise volume scattering model for a vegetated surface is derived based on the first-order radiative transfer technique. At first, the scattering mechanisms of the scattering model are analyzed for various conditions of the vegetation canopies. Then, the scattering model is simplified step by step for developing an appropriate inversion algorithm. For verifying the scattering model and the inversion algorithm, the polarimetric backscattering coefficients at 1.85 GHz, as well as the ground truth data, of a tall-grass field are measured for various soil moisture conditions. The genetic algorithm is employed in the inversion algorithm for retrieving soil moisture and surface roughness from the radar measurements. It is found that the scattering model agrees quite well with the measurements. It is also found that the retrieved soil moisture and surface roughness parameters agree well with the field-measured ground truth data.

A Field Survey to Derive Defect Rate According to the Years of Use of Fire Doors in Apartment House (공동주택 방화문의 사용연수에 따른 불량률 도출을 위한 현장조사)

  • Kim, Yun-Seong;Kwon, Yeong-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.97-98
    • /
    • 2022
  • The purpose of this study is to find out the failure conditions of fire doors in the process of use and prepare maintenance measures against them and find out the failure conditions and failure rates of fire doors according to the period of use of buildings. According to a survey of the failure rate and failure factor of fire doors, the failure rate of fire doors under 5 years was 3.7%, 13.4% of fire doors under 5 years and 10 years, and 14.8% of fire doors under 15 years and 27.6% of fire doors over 20 years. In particular, 15 years later, the failure rate of fire doors exceeded 20%. The main defects were found to be natural aging, holes, opening and closing failures, gaps, and failure and wear of accessories such as gaskets and door closers.

  • PDF

THE KERNELS OF THE LINEAR MAPS OF FINITE GROUP ALGEBRAS

  • Dan Yan
    • Bulletin of the Korean Mathematical Society
    • /
    • v.61 no.1
    • /
    • pp.45-64
    • /
    • 2024
  • Let G be a finite group, K a split field for G, and L a linear map from K[G] to K. In our paper, we first give sufficient and necessary conditions for Ker L and Ker L ∩ Z(K[G]), respectively, to be Mathieu-Zhao spaces for some linear maps L. Then we give equivalent conditions for Ker L to be Mathieu-Zhao spaces of K[G] in term of the degrees of irreducible representations of G over K if G is a finite Abelian group or G has a normal Sylow p-subgroup H and L are class functions of G/H. In particular, we classify all Mathieu-Zhao spaces of the finite Abelian group algebras if K is a split field for G.

Initiate Architecture Design Guideline Study for Infectious Disease Response Facilities in Public Health Centers - Focused on Field Survey for Temporary Facilities (지역보건의료기관 감염병 대응시설 계획을 위한 기초연구 - 임시시설 현장 조사 중심으로)

  • Kang, Jeeeun;Kwon, Soonjung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.30 no.1
    • /
    • pp.27-36
    • /
    • 2024
  • Purpose: The role and facilities of public health centers responsible for local health are becoming increasingly important due to recurring infectious diseases such as COVID-19. With sudden outbreaks of infectious diseases, the infrastructure of public health center facilities like screening clinics are constructed varies depending on local conditions. resulting in discrepancies between intended usage and actual usage. Establishing guidelines for infectious disease response facilities that can be efficiently used within local communities is necessary. Methods: Field surveys are conducted at 6 public health centers to gather insights into the essential rooms, circulation patterns, and key considerations for space planning in screening clinics. Results: Ten design considerations emerge from the data, including spatial requirements, circulation guidelines, and considerations for accommodating diverse user needs and local conditions. Implications: Further research is needed to translate these guidelines into prototypes of temporary facilities.

Back-Calculated P-y curves from Lateral Load Tests for Railway Bridge Foundation (수평재하시험을 이용한 철도교 기초의 P-y 곡선에 관한 연구)

  • Kim, Jong-Chil;SaKong, Myung;Cho, Kook-Hwan
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.821-828
    • /
    • 2011
  • A significantly larger lateral load and moment are applied on a high speed railway bridge foundation than other bridge foundations. Therefore most of bridge foundations on Honam high speed railway project were designed by high strength steel pipe piles to resist lateral load and moment, which caused the increase of construction costs. In order to perform optimum design, it is important to estimate accurate lateral resistance when designing this type of structure. Lateral load tests were carried out based on the field design data with the purpose of examining the lateral behavioral characteristics of a railway bridge foundation. The standard load test method(ASTM D 3966) was used for field tests by applying twice of design load. Total four load tests were performed on high speed railway bridge foundations with strain gages installed by every 1m along piles to measure load-resistance characteristics under applied lateral loads. The back-calculated P-y curves from strain gages were compared with estimated P-y curves using theoretical methods based on geotechnical investment data. Back-calculated P-y curves from field tests for sand and clay ground conditions were presented in this paper, which are different from theoretical P-y curves. By using the research results of this study, more accurate estimations of pile design under lateral loads can be available for similar geotechnical conditions.

  • PDF

Practical coherency model suitable for near- and far-field earthquakes based on the effect of source-to-site distance on spatial variations in ground motions

  • Yu, Rui-Fang;Abduwaris, Abduwahit;Yu, Yan-Xiang
    • Structural Engineering and Mechanics
    • /
    • v.73 no.6
    • /
    • pp.651-666
    • /
    • 2020
  • In this study, the spatial variation mechanisms of large far-field earthquakes at engineering scales are first investigated with data from the 2008 Ms 8.0 Wenchuan earthquake. And a novel 'coherency cut-off frequency' is proposed to distinguish the spatial variations in ground motions in the low-frequency and high-frequency ranges. Then, a practical piecewise coherency model is developed to estimate and characterize the spatial variation in earthquake ground motions, including the effects of source-to-site distances, site conditions and neighboring topography on these variations. Four particular earthquake records from dense seismograph arrays are used to investigate values of the coherency cut-off frequency for different source-to-site distances. On the basis of this analysis, the model is established to simulate the spatial variations, whose parameters are suitable for both near- and far-field earthquake conditions. Simulations are conducted to validate the proposed model and method. The results show that compared to the existing models, the proposed model provides an effective method for simulating the spatial correlations of ground motions at local sites with known source-to-site distances.

Power and Economic Simulation of Island for the Field Demonstration Test of Smart Microgrid System Based on Stand-alone Wind power (독립형 풍력기반 Smart Microgrid 시스템의 현장 실증 시험을 위한 도서지역 전력 및 경제성 시뮬레이션)

  • Kang, SangKyun;Lee, EunKyu;Lee, JangHo
    • New & Renewable Energy
    • /
    • v.10 no.3
    • /
    • pp.22-30
    • /
    • 2014
  • The isolated self-generating electricity with diesel engine generator has been used in islands far away from main land. It costs high because of increasing oil price, and unsafe to have supplying oil and its related components by ship due to unexpectable marine conditions. Therefore there is the need for the hybrid system of renewable energy like wind or solar energy systems with oil engine generator, which can reduce oil use and extend oil supplying period. In this study, the feasibility of such hybrid system with smart micro grid on the eight islands of Jeon-nam province is surveyed to find good place for the demonstration test of the hybrid system. In each island, 3 wind turbine systems of 10 kW and photovoltaic of 20 kW are tested with already installed diesel engine. The performance and costs of the hybrid system in each island are compared in the given conditions of solar and wind energy potential. As a result of the study, Jung-ma island is recommended for the optimum place to make real field demonstration test of isolated hybrid generating and smart grid systems.

Flow Weighted Mean Concentration and Runoff -Mass Load Relationship of Pollutants Derived from Intensively Sampled Water Quality Data of a Paddy Field (논에서의 일주기 수질 조사로부터 유도된 오염물질의 강우 -유출 사상별 유량가중평균농도와 유출량- 유하부하량 관계)

  • 윤광식;최진용;한국헌;조재영
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.44 no.5
    • /
    • pp.127-135
    • /
    • 2002
  • Water quality samples were taken for every two hours whenever runoff occurred by rainfall to investigate concentration variations of T-N, T-P and SS during runoff process from a paddy field. The difference between the highest concentration in a runoff event and flow weighted mean concentration for T-N, T-P, SS placed between 3.07∼40.16%, 11.44∼60.80%, and 15.11∼64.5%, respectively. The difference between the lowest concentration in event and event mean concentration for T-N, T-P, SS ranged between -7.24∼-31.84%, -11.59∼-47.86%, and -5.21∼-36.20%, respectively. The relationship between runoff and mass load was derived for each storm event using observed data. The relationship between runoff and mass load showed linear relationship regardless of water quality constituents and rainfall amount. The results suggested that relationship between T-N and T-P loads and runoff should be prepared separately in considering of fertilization effect and seasonal conditions. The relationship between SS and runoff should be made to reflect seasonal conditions and tillage effect.

A Study on Shallow Water Propagation Model with 2-layered Sediment (2개의 해저층으로 구성된 천해 음파전달에 관한 모델 연구)

  • 김영선;김성부
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.4
    • /
    • pp.71-80
    • /
    • 2001
  • In order to consider the sediment layer's effect to total acoustic field, we composed a 3 layered fluid model of 2 sediment layers by adding an additional layer to the Pekeris model and found solutions by using Green's function, boundary conditions and Sommerfeld radiation condition. The modes were divided into discrete modes and virtual modes, and confirmed that the characteristic equation to find discrete modes was same as that of Tolstoy and Clay for normal modes. Also, we confirmed that under similar conditions the 3 layered model showed same results as that of Pekeris model. We believe this 3 layered model can be used to study the sediment's effect on the virtual mode of near field.

  • PDF

A Study on Performance Analysis of 3kW Grid-Connected PV Systems (3kW급 계통연계형 태양광발전시스템의 성능특성 비교분석에 관한 연구)

  • So, Jung-Hun;Choi, Ju-Yeop;Yu, Gwon-Jong;Jung, Young-Seok;Choi, Jae-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.2
    • /
    • pp.9-15
    • /
    • 2004
  • 3kW grid connected PV(photovoltaic) systems have been constructed for evaluating and analyzing performance of PV system at FDTC(field demonstration test center) in Korea, PV systems installed in FDTC have been operating and monitored since November 2002. As climatic and irradiation conditions have been varied through long-term field test, data acquisition system has been constructed for measuring performance of PV system to observe the overall effect of environmental conditions on their operation characteristics. The performance of PV systems has been evaluated and analyzed for component perspective(PV array and power conditioning system) and global perspective(system efficiency, capacity factor, and electrical power energy) by field test. By the results, it is very important to develop optimal design technology of grid connected PV system.