• 제목/요약/키워드: fiber reinforced high-strength concrete

검색결과 532건 처리시간 0.029초

강섬유 보강 초고성능 콘크리트의 전단 전달 모델 (Shear Transfer Strength Evaluation for Ultra-High Performance Fiber Reinforced Concrete)

  • 이지형;홍성걸
    • 한국공간구조학회논문집
    • /
    • 제15권2호
    • /
    • pp.69-77
    • /
    • 2015
  • Ultra High Performance Fiber Reinforced Concrete (UHPFRC) has a outstanding tensile hardening behaviour after a crack develops, which gives ductility to structures. Existing shear strength model for fiber reinforced concrete is entirely based on crack opening behavior(mode I) which comes from flexural-shear failure, not considering shear-slip behavior(mode II). To find out the mode I and mode II behavior on a crack in UHPFRC simultaneously, maximum shear strength of cracked UHPFRC is investigated from twenty-four push-off test results. The shear stress on a crack is derived as variable of initial crack width and fiber volume ratio. Test results show that shear slippage is proportional to crack opening, which leads to relationship between shear transfer strength and crack width. Based on the test results a hypothesis is proposed for the physical mechanics of shear transfer in UHPFRC by tensile hardening behavior in stead of aggregate interlocking in reinforced concrete. Shear transfer strength based on tensile hardening behavior in UHPFRC is suggested and this suggestion was verified by comparing direct tensile test results and push-off test results.

최소 전단철근 대용으로의 강섬유 콘크리트의 전단기여도 평가 (Evaluation on Shear Contribution of Steel Fiber Reinforced Concrete in Place of Minimum Shear Reinforcement)

  • 김철구;박홍근;홍건호;강수민
    • 콘크리트학회논문집
    • /
    • 제27권6호
    • /
    • pp.603-613
    • /
    • 2015
  • 현행 콘크리트 구조기준에는 전단파괴의 취성적 특성을 고려하여 휨 부재에 최소전단철근을 배근하도록 규정하고 있고, 강섬유 보강 콘크리트 사용시 강섬유가 최소전단철근을 대신하여 사용가능하도록 허용하고 있다. 본 연구에서는 이러한 최소전단철근과 강섬유가 전단강도에 미치는 영향을 단순지지 보 실험을 통해 분석하였다. 실험결과를 살펴보면, 강섬유 보강이 최소 전단철근보다 전단강도에 미치는 영향이 크게 나타났고 특히, 고강도콘크리트가 사용된 경우 강섬유 효과가 크게 발휘되었다. 강섬유 콘크리트의 특성을 살펴보기 위해 기존 실험 자료를 분석하였고 현행 기준에 사용되고 있는 최소전단철근 대용으로의 강섬유 보강 콘크리트 보의 적절성을 평가하였다.

하이브리드 유기섬유 보강 콘크리트의 제조 및 휨성능 평가 (A Processing and Flexural Performance Evaluation of Hybrid Organic Fiber Reinforced Concrete)

  • Jeon, Chanki;Jeon, Joongkyu;Shim, Jaeyeong
    • 한국재난정보학회 논문집
    • /
    • 제13권2호
    • /
    • pp.213-220
    • /
    • 2017
  • 일반적으로 유기섬유는 섬유 자체의 인장강도 및 탄성계수는 작지만, 내화성 및 내부식성이 우수하고, 콘크리트의 균열 제어 및 내충격 성능 향상에 효과적인 섬유이다. 따라서, 유기섬유는 콘크리트용 보강 섬유로서의 적용성이 매우 높은 재료이다. 본 연구에서는 폴리아미드(PA)섬유와 고강력의 폴리에스터(PET)섬유를 혼입한 하이브리드 유기섬유를 개발하였으며, 하이브리드 유기섬유를 혼입한 섬유보강 콘크리트의 휨성능 시험을 통해 하이브리드 유기섬유 보강 콘크리트의 에너지 흡수능력을 평가하고자 한다.

고강도 강섬유 보강 콘크리트의 장기거동 특성에 관한 실험적 연구 (A experimental study on the long-term response of high-strength Steel-Fiber Reinforced Concrete)

  • 서종명;김재기;이주하;윤영수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.337-340
    • /
    • 2004
  • In recent days, the beneficial effects of using fiber reinforced concrete, especially Steel Fiber Reinforced Concrete, have been on the rise. However, few studies on long-term behavior of SFRC are executed in spite of great demand of SFRC. The fact that SFRC is far better than NRC in various properties such as tensile strength, ductility, flexural toughness has been certified by many researchers. And, those advantages can be also applied to decrease the structures deterioration induced by creep and shrinkage. Furthermore, even though it is fact that SFRC is generally used in joint members to distribute concentrated stresses by fibers, SFRC is treated as NRC in designing especially for long-term behavior of structures. So this paper is about a study on the long-term response of SFRC applied to HPC about 40MPa. Therefore, in this paper, the test results of eighteen high-strength concrete specimens and steel fiber-reinforced concrete specimens, with steel fiber content of $1\%$ by volume were presented. The test result shows that SFRC is advantageous rather than NRC in long-term response.

  • PDF

First Diagonal Cracking and Ultimate Shear of I-Shaped Reinforced Girders of Ultra High Performance Fiber Reinforced Concrete without Stirrup

  • Wu, Xiangguo;Han, Sang-Mook
    • International Journal of Concrete Structures and Materials
    • /
    • 제3권1호
    • /
    • pp.47-56
    • /
    • 2009
  • The first diagonal cracking and ultimate shear load of reinforced girder made of ultra high performance fiber reinforced concrete (UHPFRC) were investigated in this paper. Eleven girders were tested in which eight girders failed in shear. A simplified formulation for the first diagonal cracking load was proposed. An analytical model to predict the ultimate shear load was formulated based on the two bounds theory. A fiber reinforcing parameter was constituted based on the random assumption of steel fiber uniform distribution. The predicted values were compared with the conventional predictions and the test results. The proposed equation can be used for the first cracking status analysis, while the proposed equations for computing the ultimate shear strength can be used for the ultimate failure status analysis, which can also be utilized for numerical limit analysis of reinforced UHPFRC girder. The established fiber reinforcing theoretical model can also be a reference for micro-mechanics analysis of UHPFRC.

초고강도 강섬유 보강 콘크리트의 휨특성에 관한 연구 (A Study on the flexural Behavior of Ultra-Strength Steel Fiber Reinforced Concrete)

  • 류금성;박정준;강수태;고경택;김성욱
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(II)
    • /
    • pp.333-336
    • /
    • 2005
  • This paper presents a comparative evaluation of eight different types of steel fibers used as reinforcing material in concrete beams. The fibers which used ultra-strength steel fiber reinforced concrete were fiber length of 30 to 60mm, aspect ratio of 43 to 86, W/B ratio 0.16 to 0.30, fiber types of both ends hooked and straight shape and fiber volume fraction of 1 to 5$\%$. As for the test results, it estimated the influence of fiber volume, length and aspect ratio on the mechanical properties of high toughness concrete, the mechanical properties improved according to increase fiber volume, to increase aspect ratio and to long fiber length. And the resonable fiber volume in high toughness concrete was analyzed 2$\%$ based on the results of mechanical properties.

  • PDF

강섬유의 혼입이 고강도 강섬유 보강 시멘트 복합체의 압축강도에 미치는 영향 (The Effect of Steel Fiber on the Compressive Strength of the High Strength Steel Fiber Reinforced Cementitious Composites)

  • 강수태;김성욱;박정준;고경택
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제12권3호
    • /
    • pp.101-109
    • /
    • 2008
  • 본 연구에서는 마이크로 입자들로 구성된 매트릭스의 강섬유 보강 시멘트 복합체에서 강섬유가 압축강도에 미치는 영향을 규명하고자 하였으며, 강섬유의 섬유혼입률과 섬유형상비에 따른 영향을 파악하고 혼입률과 형상비를 동시에 고려한 변수인 섬유보강지수(RI)에 따른 압축강도의 변화를 살펴보았다. 실험결과에 따르면 마이크로 입자로 구성된 매트릭스의 강섬유보강 복합체에서는 섬유보강지수가 증가에 따라 압축강도가 선형적으로 증가하였다. 이와 같은 결과로부터 섬유보강지수와 압축강도와의 관계를 나타내는 모델식을 제안하였다.

Fiber reinforced concrete corbels: Modeling shear strength via symbolic regression

  • Kurtoglu, Ahmet E;Gulsan, Mehmet E;Abdi, Hussein A;Kamil, Mohammed A;Cevik, Abdulkadir
    • Computers and Concrete
    • /
    • 제20권1호
    • /
    • pp.65-75
    • /
    • 2017
  • In this study, a novel application of symbolic regression (SR) is employed for the prediction of ultimate shear strength of steel fiber reinforced (SFRC) and glass fiber reinforced (GFRC) corbels without stirrups, for the first time in the literature. A database is created using the test results (42 tests) conducted by the authors of current paper as well as the previous studies available in the literature. A symbolic regression based empirical formulation is proposed using this database. The formulation is unique in a way that it has the capability to predict the shear strength of both SFRC and GFRC corbels. The performance of proposed model is tested against randomly selected testing set. Additionally, a parametric study with a wide range of variables is carried out to test the effect of each parameter on the shear strength. The results confirm the high prediction capacity of proposed model.

150MPa급 초고강도 콘크리트의 섬유 복합 혼입에 따른 휨강도 검토 (Review of 150MPa grade Ultra-High Strength Concrete which is Hybrid Fiber mixture)

  • 김성용;하정수;김학영;김한식;임남기;정상진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 추계 학술논문 발표대회
    • /
    • pp.36-37
    • /
    • 2013
  • It is the study on the mechanical properties of the material when mixing hybrid fiber as steel and synthetic fiber to improve fire resistance and toughness of concrete. Finally, The purpose is to identify of mechanical properties of Hybrid Fiber-Reinforced Ultra High Strength Concrete such as flexural strength.

  • PDF

전단철근이 없는 I형 휨보강 UHPCC 보의 거동해석 (Analysis of the Reinforced I section UHPCC (Ulrea High Performance Cementitous Composites) beam without stirrup)

  • 김성욱;한상묵;강수태;공정식;강준형;전상은
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.409-412
    • /
    • 2004
  • Over last decade extensive researches have been undertaken on the strength behaviour of Fiber Reinforced Concrete(FRC) structures. But the use of Ultra-High Strength Steel Fiber Cementitious Concrete Composites is in its infancy and there is a few experiments, analysis method and design criteria on the structural elements constructed with this new generation material which compressive strength is over 150 MPa and characteristic behaviour on the failure status is ductile. The objective of this paper is to investigate and analyze the behaviour of reinforced rectangular structural members constructed with ultra high performance cementitious composites (UHPCC). This material is known as reactive powder concrete (RPC) mixed with domestic materials and its compressive strength is over 150MP. The variables of test specimens were shear span ratio, reinforcement ratio and fiber quantity. Even if there were no shear stirrups in test specimens, most influential variable to determine the failure mode between shear and flexural action was proved to be shear span ratio. The characteristics of ultra high-strength concrete is basically brittle, but due to the steel fiber reinforcement behaviour of this structure member became ductile after the peak load. As a result of the test, the stress block of compressive zone could be defined. The proposed analytical calculation of internal force capacity based by plastic analysis gave a good prediction for the shear and flexural strength of specimens. The numerical verification of the finite element model which constitutive law developed for Mode I fracture of fiber reinforced concrete correctly captured the overall behaviour of the specimens tested.

  • PDF