• 제목/요약/키워드: fiber implantation

Search Result 15, Processing Time 0.025 seconds

Induced Death of Escherichia coli Encapsulated in a Hollow Fiber Membrane as Observed In Vitro or After Subcutaneous Implantation

  • Granicka, L. H.;Zolnierowicz, J.;Wasilewska, D.;Werynski, A.;Kawiak, J.
    • Journal of Microbiology and Biotechnology
    • /
    • v.20 no.1
    • /
    • pp.224-228
    • /
    • 2010
  • The encapsulation of bacteria may be used to harness them for longer periods of time in order to make them viable, whereas antibiotic treatment would result in controlled release of therapeutic molecules. Encapsulated Escherichia coli GFP (green fluorescent protein) (E. coli GFP) was used here as a model for therapeutic substance - GFP fragments release (model of bioactive substances). Our aim was to evaluate the performance of bacteria encapsulated in hollow fibers (HFs) treated with antibiotic for induction of cell death. The polypropylene-surface-modified HFs were applied for E. coli encapsulation. The encapsulated bacteria were treated with tetracycline in vitro or in vivo during subcutaneous implantation into mice. The HF content was evaluated in a flow cytometer, to assess the bacteria cell membrane permeability changes induced by tetracycline treatment. It was observed that the applied membranes prevented release of bacteria through the HF wall. The E. coli GFP culture encapsulated in HF in vitro proved the tetracycline impact on bacteria viability and allows the recognition of the sequence of events within the process of bacteria death. Treatment of the SCID mice with tetracycline for 8 h proved the tetracycline impact on bacteria viability in vivo, raising the necrotic bacteria-releasing GFP fragments. It was concluded that the bacteria may be safely enclosed within the HF at the site of implantation, and when the animal is treated with antibiotic, bacteria may act as a local source of fragments of proteins expressed in the bacteria, a hypothetical bioactive factor for the host eukaryotic organism.

An experimental investigation on effect of elevated temperatures on bond strength between externally bonded CFRP and concrete

  • Attari, Behzad;Tavakkolizadeh, Mohammadreza
    • Steel and Composite Structures
    • /
    • v.32 no.5
    • /
    • pp.559-569
    • /
    • 2019
  • The bond strength between composite laminates and concrete is a key factor that controls the behavior of concrete members strengthened with fiber reinforced polymer (FRP) sheets, which can be affected by several parameters such as thermal stresses and surface preparation. This article presents the result of an experimental study on the bond strength between FRP sheets and concrete at ambient temperature after specimens had been exposed to elevated temperatures of up to $200^{\circ}C$. For this purpose, 30 specimens of plain concrete with dimensions of $150{\times}150{\times}350mm$ were prepared. Three different conventional surface preparation methods (sandblasting, wire brushing and hole drilling) were considered and compared with a new efficient method (fiber implantation). Deformation field during each experiment was monitored using particle image velocimetry. The results showed that, the specimens which were prepared by conventional surface preparation methods, preserved their bond integrity when exposed to temperature below glass transition temperature of epoxy resin (about $60^{\circ}C$). Beyond this temperature, the bond strength and stiffness decreased significantly (about 50%) in comparison with control specimens. However, the specimens prepared by the proposed method displayed higher bond strengths of up to 32% and 90% at $25^{\circ}C$ and $200^{\circ}C$, respectively.

Histological Study on the Interface of Bone and Implant (골과 임플란트 접촉면의 조직학적 연구)

  • Kim, Ju-Sung
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.37 no.1
    • /
    • pp.35-40
    • /
    • 2005
  • This paper reports the morphological nature of the remodelled interface process between implants and surrounding bone after 1, 4, 6, 8 and 12 weeks of implantation of smooth machined implants into rat tibias. After 4 weeks of implantation, histochemical analysis showed that the new bone was growing in direct contact with the implant. In the forming process, the activatived osteoblast cells migrated toward the interface and colonized the surface at the contact areas. This immature woven bone, rich in osteocyte lacunae, was deposited directly onto the implant surface. Osteoblast activity was found to continue ill 12 weeks of implantation The osteoblasts in lacunar areas developed numerous processes and synthesized bone matrix, after all, surrounded by secreting matrix. At the 12th week, the amount of newly formed bone matrix between bone and implant increased in mineralization. The mineralized mature bone contained well organized collagen fibers with characteristic banding pattern bone tissue formation around the implant.

  • PDF

Implantation of portable hydrogen alarm system based on palladium coated single mode optical fiber sensor (팔라듐이 코팅된 단일모드 광섬유 센서를 이용한 수소 경보 시스템 구현)

  • Mun, Nam-Il;Yang, Byung-Cheol;Kim, Kwang-Taek;Kim, Tae-Un
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.269-273
    • /
    • 2009
  • In this paper, a study on a portable hydrogen alarm system based on the palladium coated single mode fiber sensor has been reported. The fabricated hydrogen sensor exhibited 0.14 dB, 0.41 dB and 0.54 dB optical intensity variation when it was exposed by the nitrogen and hydrogen mixed gas containing 0.5 %, 1 % and 4 % of the hydrogen concentration, respectively. The fabricated sensor exhibited 20 second of response time and 120 second of recovery time for 4 % hydrogen containing gas. The fiber optics layout and software algorithm for detection of hydrogen leakage have been presented. The implanted portable hydrogen alarm system successfully generated an alarm signal when a 4 % hydrogen containing gas was leaked out.

A Study of Current Perception Threshold of Trigeminal Nerve after Tooth Implantation (치아임플란트 시술 후 삼차신경에서의 전류인지역치에 대한 연구)

  • Lim, Hyun-Dae;Lee, Jung-Hyun;Lee, You-Mee
    • Journal of Oral Medicine and Pain
    • /
    • v.32 no.2
    • /
    • pp.187-200
    • /
    • 2007
  • This study attempted to contribute to the clinical application of implant operation by making a quantitative nerve examination using a neurometer for the evaluation of sensory disturbances that could be incurred after the implantation in the dental clinics, and it intended to establish an objective guideline in the evaluation of sensory nerve after the operation of implant. An inspection was performed with the frequencies of 2000Hz, 250 Hz and 5 Hz before and after the operations of tooth implant using $Neurometer^{(R)}$ CPT/C (Neurotron, Inc. Baltimore, Maryland, USA) for 44 patients who had performed an implant operation among the patients coming to Daejeon Sun Dental Hospital in 2006 and 30 people for control group. The measuring sites were maxillary nerve ending and mandibular nerve ending of trigeminal nerve according to the implant operating regions. The current perception threshold (CPT) by each nerve fiber was specifically responded under the electric stimulation of 2000 Hz in case of $A{\beta}$ fiber and of 250 Hz in case of $A{\delta}$ fiber and of 5Hz in case of C fiber. The CPT test could be performed to assess the damages of peripheral nerve in the trigeminal nerve area and it stimulated selective nerve fibers by generating the electricity of specific frequency in the peripheral nerve area. The nerve fibers with varied thickness were responsive selectively to the electric stimulation with different frequencies; accordingly, they applied the electric stimulation with different frequencies and the reaction threshold of $A{\beta},\;A{\delta}$ and C fibers selectively responsive to each electric current could be individually evaluated. In the assessment through the CPT, the increase and decrease of the CPT could be measured so that sensory disturbances such as hyperaesthesia or hypoaesthesia could be diagnosed. This study could obtain the following results after the assessment of the CPT before and after the implant operation. 1. In the assessment before and after the implant operation, the CPT in the frequencies of 2000 Hz, 250 Hz, 5 Hz for maxillary branch increased on the whole after the operation and the CPT for mandibular branch in the $A{\beta}$-fiber(2000 Hz) and C-fiber(5 Hz )after the operation increased statistically significantly. 2. For the groups of patients with medically compromised or its subsequent medicinal prescription, there were no significant differences before and after the implant operation and for the control groups, significantly high CPT was shown after the implant operation in the left $A{\beta}$-fiber(2000 Hz) and C-fiber(5 Hz). 3. In the comparison of the measured value of the CPT before the operation between the control group and the implant operation group, the latter group had a significantly high measured value of the CPT in the right $A{\beta}$-fiber(2000 Hz) and C-fiber(5 Hz) and there were significant differences in $A{\beta}$-fiber(2000 Hz) in the CPT assessment after the implant operation for the control group. 4. Male participants had higher CPT than female counterparts; however, there were no statistic significances. In the CPT evaluation before and after implant operation, there were no statistical differences in the male group while the right C-fiber(5 Hz) and left $A{\beta}$-fiber(2000Hz) were significantly high in the female group. 5. In the comparison between the group who complain sensory disturbance and the other group, the CPT increased on the whole in the former group, but there were no statistical significances. In the groups, whom there was an increase in VAS, the CPT after the implant operation in the right C-fiber(5 Hz) increased significantly; meanwhile, in case that the VAS mark was '0' before and after the operation, the CPT after the operation in the left $A{\beta}$-fiber(2000 Hz) increased significantly. This study suggested that the CPT measurements using $Neurometer^{(R)}$ CPT/C, provide useful information of objective and quantitative sensory disturbances for tooth implantation.

THE EARLY EFFECT OF DIFFERENT ROOT TREATMENT MODALITIES ON CONNECTIVE TISSUE ATTACHMENT IN RATS (치근면 처치시 결합조직 부착에 관한 초기효과의 조직병리학적 연구)

  • Moon, Sang-Joon;Lee, Chong-Heon;Lee, Jae-Hyun
    • Journal of Periodontal and Implant Science
    • /
    • v.24 no.1
    • /
    • pp.109-119
    • /
    • 1994
  • An essential fact in the regeneration of new periodontal tissue after periodontal therapy is the reattachment of collagen fibers to the tooth. Two phenomena play a fundamental role in preventing new connective tissue attachment to the exposed root surface ; 1) The apical migration of the junctional epithelium 2) The contamination of cementum by toxic substances, especially endotoxins. Authors have used rat submucosal implantation of root sections to study the connective tissue healing to periodontally diseaed root, previously planed and demineralized with citric acid and tetracycline- HCl. The results were obtained as follows. 1. The connective tissue attachment was increased in tetracycline, citric acid, non disease, scaling and root planing order and inflammatory reaction was seen in the rat teeth, no treatment group. 2. Collagen fiber attachment at the dentin surface was more increased than cementum surface 3. In 2 week of citric acid and tetracycline-HCl specimens, osteoid was seen near the fibrotic band. 4. In the MT view, collagen fiber formation was increased with time and the numerous collagen fiber and connective tissue was more densly attached to the tooth surfaces in the tetracycline-HCl group than the citric acid group.

  • PDF

Foreign Body Reaction after Implantation of a Device for Intervertebral Assisted Motion

  • Seo, Jun-Yeong;Ha, Kee-Yong;Kim, Young-Hoon;Ahn, Joo-Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.6
    • /
    • pp.647-649
    • /
    • 2016
  • The device for intervertebral assisted motion (DIAM) is a dynamic implant that consists of a silicone bumper enveloped by a polyethylene terephthalate (PET) fiber sack. Silicone and PET were used because of their biological inertness, but repetitive motion of the spine can cause wear on the implant nonetheless. The purpose of this study is to report a case of foreign body reaction (FBR) against a DIAM. A 72-year-old female patient presented with lower back pain and both legs radiating pain. She had undergone DIAM implantation at L4-5 for spinal stenosis 5 years previously. The intervertebral disc space of L4-5, where the DIAM was inserted, had collapsed and degenerative scoliosis had developed due to left-side collapse. MRI showed L3-4 thecal sac compression and left L4-5 foraminal stenosis. The patient underwent removal of the DIAM and instrumented fusion from L3 to L5. During surgery, fluid and granulation tissue were evident around the DIAM. Histopathology showed scattered wear debris from the DIAM causing chronic inflammation due to the resulting FBR. A FBR due to wear debris of a DIAM can induce a hypersensitivity reaction and bone resorption around the implant, causing it to loosen.

Preparation and Biocompatibility of Medical Fiber from Novel Regenerated Cellulose from Styela clava tunic (미더덕껍질의 재생셀룰로오스를 이용한 의료용 섬유의 제조 및 생체적합성)

  • Song, Sung Hwa;Kim, Ji Eun;Choi, Jun Young;Park, Jin Ju;Lee, Mi Rim;Song, Bo Ram;Lee, Yechan;Kim, Hong Sung;Lee, Jae Ho;Lim, Yong;Hwang, Dae Youn;Jung, Young Jin
    • Textile Coloration and Finishing
    • /
    • v.30 no.2
    • /
    • pp.117-129
    • /
    • 2018
  • Cellulose has been widely applied into various medical fields including scaffolding, tissue engineering and tissue formation. In this study, we manufactured cellulose medical fiber from Styela clava tunics(SCT-CS) and analyzed the tensile strength, elongation at break, fluid uptake and surface morphology. And then, the biocompatibility and toxicity of SCT-CS were measured in Sprague-Dawley(SD) rats after the implantation for 30, 60 and 90 days. The level of tensile strength and fluid uptake were lower in SCT-CS than chromic catgut(CCG), while elongation at break level were maintained the higher in SCT-CS. Also, the roughness with pronounced surface patterns as a result of in vivo degradation was significantly greater in CCG than this of SCT-CS although these levels gradually appeared with time in both groups. After implantation for 90 days, SCT-CS and CCG was successfully implanted around muscle of thigh without any significant immune response. Furthermore, no significant alterations were measured in serum parameters and the specific pathological features induced by most toxic compounds for liver and kidney toxicity. Therefore, these results suggest that SCT-CS showing good biocompatibility and non-toxicity can be successfully prepared from cellulose powder of SCT as well as has the potential for use as a powerful biomaterial for medical sutures.

Morphological Comparison of Spermatozoa in the Korean Greater Horseshoe Bat (Rhinolophus ferrumequinum korai) and Long-Fingered Bat (Miniopterus schreibersi fuliginosus) (한국산 관박쥐 (Rhinozophus ferrumequinum korai)와 긴가락박쥐 (Miniopterus schreibersi fuliginosus) 정자의 형태 비교)

  • Kim, Sang-Sick;Lee, Jung-Hun;Son, Sung-Won;Choi, Byung-Jin
    • Applied Microscopy
    • /
    • v.29 no.1
    • /
    • pp.1-10
    • /
    • 1999
  • The aim of the present study was to investigate with transmission electron misroscope the comparative morphology of epididymal spermatozoa in two species of the Korean insectivorous bats belonging to 'prolonged sperm storage' type (Rhinolophus ferrumequinum korai) and 'delayed implantation' type (Miniopterus schreibersi fuliginosus). Sperm head of the R. ferrumequinum korai was bullet shaped and that of M. schreibersi fuliginosus was spatula shaped. The nuclei of the sperm head of the R. ferrumequinum korai and M. schreibersi fuliginosus occupied two-third and a half of it, respectively. The segmented columns of R. ferrumequinum korai were about 12 to 14 in number, and those of the M. schreibersi fuligincsus were about 10 to 12. Particularly, a pile of the satellite fibers in middle piece of R. ferrumequinum korai remained the inner aspect of the outer dense fibers, but those of the M. schreibersi fuliginosus were not.

  • PDF

In vitro and in vivo Application of PLGA Nanofiber for Artificial Blood Vessel

  • Kim, Mi-Jin;Kim, Ji-Heung;Yi, Gi-Jong;Lim, Sang-Hyun;Hong, You-Sun;Chung, Dong-June
    • Macromolecular Research
    • /
    • v.16 no.4
    • /
    • pp.345-352
    • /
    • 2008
  • Poly(lactic-co-glycolic acid) (PLGA) tubes (5 mm in diameter) were fabricated using an electro spinning method and used as a scaffold for artificial blood vessels through the hybridization of smooth muscle cells (SMCs) and endothelial cells (ECs) differentiated from canine bone marrow under previously reported conditions. The potential clinical applications of these artificial blood vessels were investigated using a canine model. From the results, the tubular-type PLGA scaffolds for artificial blood vessels showed good mechanical strength, and the dual-layered blood vessels showed acceptable hybridization behavior with ECs and SMCs. The artificial blood vessels were implanted and substituted for an artery in an adult dog over a 3-week period. The hybridized blood vessels showed neointimal formation with good patency. However, the control vessel (unhybridized vessel) was occluded during the early stages of implantation. These results suggest a shortcut for the development of small diameter, tubular-type, nanofiber blood vessels using a biodegradable material (PLGA).