• Title/Summary/Keyword: fence

Search Result 434, Processing Time 0.033 seconds

Reducing the Falling Accident due to the Removal of Safety Fence from Gondola (곤돌라 안전난간 제거 등으로 인한 추락재해 감소방안)

  • Byun, Hyung Shik;Rhim, Jong kuk;Yang, Won Beak
    • Journal of the Korea Safety Management & Science
    • /
    • v.21 no.2
    • /
    • pp.9-14
    • /
    • 2019
  • Gondola is widely used as a construction facility to perform external finishing work without using scaffolding at a construction site. However, since 2000, there have been 17 deaths from now so these risks associated with work can not be ignored. Therefore, it is expected that it will contribute greatly to prevent related disasters if introducing necessary measures to prevent repeated related disasters and installing additional safety devices. In order to eliminate the risk factor according to the operation of the gondola, it is necessary for the operator to use it to use it while the examination of each product is completed, and to use the over load Dangerous arbitrary measures such as arbitrary operation of the prevention device, removal of the safety fence for convenience of work, installation of the wire rope installed in the air, falling out of the wire rope and falling to the ground Do not perform such sealing measures so that any operation of the overload prevention device can not be done so as not to take such arbitrary measures, or wire the power supply wire to the safety fence so as not to delete the safety fence. Then, when the safety fence is removed, so that it does not become a gondola operation, or when replacing the wire rope in the air, to prevent the wire rope from coming off, Additional measures such as installing falling down prevention device may be necessary.

Evaluation of Structural Performance for High Strength Rockfall Protection Fence according Reinforcement of H-Beam using Numerical Analysis (수치해석을 통한 지주 보강에 따른 고강도 낙석 방지울타리 구조성능 평가)

  • Hyunwoo Jin;Sanghoon Seo;Duho Lee;Youngcheol Hwang
    • Journal of the Korean GEO-environmental Society
    • /
    • v.24 no.1
    • /
    • pp.25-36
    • /
    • 2023
  • In Korea, the rockfall prevention fence is designed with 50kJ of rockfall kinetic energy in order to prevent damages such as falling rocks and landslides. In the case of rockfall kinetic energy, it is highly dependent on the shape of the slope on which it occurs. As a previous study, a fence performance evaluation was conducted for 100kJ rockfall impact energy using ETAG 27. However, previous studies have focused on newly installed rockfall prevention fences. In this study, a reinforcing materials was installed on the existing rockfall prevention fence through numerical analysis, and the structural performance of the high-strength rockfall prevention fence capable of defending against 120kJ of rockfall kinetic energy was evaluated.

Characteristics and Energy Absorbing Capacity for Rockfall Protection Fence from In-Situ Rockfall Tests (현장 낙석실험을 통한 낙석방지울타리의 특성 및 성능 평가)

  • 구호본;박혁진;백영식
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.6
    • /
    • pp.111-121
    • /
    • 2001
  • Rockfall protection fences are used for diminishing rockfall damage in roads side slopes. In order to install the fences in effective way, the conditions of rock slopes and total predicted impact energy of fa11ing rock should be considered. However, the fences have been constructed without any consideration for lithology, height and slope angle of rock slope in Korea. In addition, the information about the performance of the protection fences, which should be evaluated by in-situ test or laboratory test in order to check out the practical use in the field, is not available. Therefore, in design manual for the rockfall protection fence, the specific details for the installation of this type of fence are not provided yet. The full sized rockfall in situ test was carried out for the calculation of falling energy of rock and the evaluation of the maximum energy absorbing capacity of fence. For this test, the rock slopes whose heights are about 20 m and dip angle of 65 degree, have been chosen. This is because those geometries are mean height and slope angle of most road cut slopes along Korean national highway. Based on the preliminary simulation procedure, four different sizes of concrete ball (0.7, 1.3, 2.3 and 4.3 ton) were prepared and flour different types of protection fence were constructed. The results of this test provide information about the maximum energy absorbing capacity of the fence, kinetic energy of rockfall and restitution coefficient, and these results can be utilized in the establishment of rockfall fence design and construction manual.

  • PDF

A Study on Bounce Height and Impact Energy Considering Slope Height, Rockfall Weight Using Rockfall Program Considering Slope Height, Rockfall Weight (낙석해석프로그램을 이용한 비탈면 높이, 낙석중량별 도약높이 및 충격에너지 검토)

  • You, Byung-Ok;Han, Won-Jun;Lee, Sang-Duk;Shim, Jea-Won
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.3
    • /
    • pp.47-54
    • /
    • 2011
  • The rockfall protection fence installed to secure safety against rockfall occurring in cut slope has been designed under the condition with 50kJ of impact energy arising when the 400kg of rock block is falling from 12.5m height. However, in falling case of bigger rock block or from higher place, it is hard to be secure of safety with existing rockfall protection fence. Using the rockfall program, safety analysis for rockfall is conducted in this paper by changing slope height, separating distance from fence, and slope angle, according to rock block sizes. In the result of analysis, when a 400kg of rock block which is designed load is fallen, the existing rockfall protection fence with 2.5m height can secure most of rock fall except some cases for the slope having 20m or less hight, whereas for more than 20m height, the fallen rock is frequently splattered over the rockfall protection fence, as well as the impact energy of rockfall may exceed designed impact energy. Therefore, in the design of rock fence, it is considered appropriate to design that after conducting safety review for rockfall according to the ground conditions, evaluating the bounce height and impact energy of rock fall, and then installing appropriate rockfall protection fence would be applicable rather than just following standards based design drawing.

Oil Fence Durability Enhancement for Marine Environmental Protection : Improvement of Inspection Process (해양환경 보호를 위한 오일펜스의 내구성 향상 : 검정제도 개선 방향)

  • Jang, Pankil;Seo, Jeong Mog;Lee, Heejin
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.6
    • /
    • pp.731-736
    • /
    • 2021
  • Oil fences effectively prevent the spread of oil spilled in the sea, thereby reducing the damage to the marine environment. However, the fence is damaged by oil and structures at the accident site and is discarded. When incinerated disposal method for discarded fences, fine dust, and harmful materials are generated. Moreover, as a part of the damaged fence is dumped into the sea, it may cause secondary environmental pollution, such as microplastics. Therefore, in this study, durability was measured using the most common solid foam type oil fences. As a result, the reduction rate of after five days of contact was 13 % in seawater and 3 % in oil, affected by temperature changes. Thus, the durability of the fence should be improved because it is exposed to seawater and oil and affected by wind, light, and waves depending on the weather conditions. Therefore, we suggest a method to improve the oil fence inspection to strengthen the durability of the fence's fabric part.

Drag Reduction by Fence of a Square Prism near Plane Wall (벽면근처에 놓인 정방형주의 펜스에 의한 항력저감)

  • Ro, Ki-Deok;Kim, Kwang-Seok
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2567-2572
    • /
    • 2007
  • The suppression of fluid force acting on a square prism near plane wall was studied by attaching fences on the corners of the prism. The height of the fence was 10% of the square width and the range of Reynolds number considered was Re=$2.0{\times}10^4$. The experimental parameters were the attaching position and numbers of fences, the space ratios G/B(G/B=0.1${\sim}$1.2) between prism and plane wall. The average drag coefficients were increased and the average lift coefficients were decreased and increased with the space ratios toward plane wall. The drag of the prism was reduced average 7.6% with the space ratios by attaching the normal fence at the rear and upper corner and the horizontal normal fence at the rear and lower corner on the prism. In this case, the separated flow at the front and upper corner was reattached on the upper side of the prism and the vortex streets between the prism and plane wall were appeared more slowly than that of prism without fences.

  • PDF

Effects of the Inlet Boundary Layer Thickness and the Boundary Layer Fence on the Heat Transfer Chracteristics in a Turbine Cascade (입구경계층 두께와 경계층 펜스가 터빈 캐스케이드내 열전달 특서에 미치는 영향)

  • Jeong, J.S.;Chung, J.T.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.765-770
    • /
    • 2001
  • The objective of the present study is to investigate the effects of the various inlet boundary layer thickness on convective heat transfer distribution in a turbine cascade endwall and blade suction surface. In addition, the proper height of the boundary layer fences for various inlet boundary layer thickness were applied to turbine cascade endwall in order to reduce the secondary flow, and to verify its influence on the heat transfer process within the turbine cascade. Convective heat transfer distributions on the experimental regions were measured by the image processing system. The results show that heat transfer coefficients on the blade suction surface were increased with an augmentation of inlet boundary layer thickness. However, in a turbine cascade endwall, magnitude of heat transfer coefficients did not change with variation of inlet boundary layer thickness. The results also present that the boundary layer fence is effective in reducing heat transfer on the suction surface. On the other hand, in the endwall region, boundary layer fence brought about the subsidiary heat transfer increment.

  • PDF

A Study on the Improvement of the luminous Efficiency in ac-PDP with New Fence Structure (새로운 Fence 전극 구조에 의한 ac-PDP 효율 개선에 관한 연구)

  • Kwon, Bee-Su;Ok, Jung-Woo;Kim, Hyun-Jong;Lee, Don-Kyu;Kim, Dong-Hyun;Lee, Ho-Jun;Park, Chung-Hoo
    • Proceedings of the KIEE Conference
    • /
    • 2005.11a
    • /
    • pp.201-203
    • /
    • 2005
  • To improvement the performance of PDPs, we developed an ac-PDP with new fence structure. By measuring minimum sustaining voltage(Vs), discharge current(Ion), discharge(Ioff), and brightness of the light from a 4-inch at-PDP, performances of the conventional structure and proposed structure are compared. The experimental results show that the test panel with the proposed new fence structure shows high luminance by 10%, and high luminous efficiency by 30% compared with the conventional structure at the Ne-Xe(8%) gas mixture of 400 torr.

  • PDF

A Study on the Possibility of Electrical Fires due to the Short Circuit and Ground Fault of Power Cable Supported by an Iron Fence (철제펜스로 지지된 동력배선의 단락.지락에 의한 전기화재 발생 개연성 연구)

  • Kim, Jeong-Hun;Park, Byoung-Ki;Song, Jong-Hyeok;Jung, Ki-Chang
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.6
    • /
    • pp.41-45
    • /
    • 2007
  • Short circuit and ground fault account for the primary causes of electrical fires. In this research, real-scale experiments were conducted to assess the possibility of electrical fires due to these causes. The experiment conditions were identical with an actual fire accident, in which the power cable was supported by an iron fence. The purposes of this research are to investigate the short circuit caused by wire cutting, the conductivity of the iron fence depending on its coating conditions, and the ground fault of one wire or two wires in an effort to reconstruct the fire accident. The test results show that, owing to the instant operation of circuit breaker in the moment of short circuit or ground fault, the generated ignition energy is far less than necessary to start an ignition. Therefore it is concluded that electrical fire is highly unlikely if the electric system is protected by a circuit breaker with normal functions.

The new fence structure in the AC PDP for a high luminance and luminous efficiency (AC PDP의 휘도 및 효율 향상을 위한 새로운 Fence 전극구조)

  • Yoon, Cho-Rom;Cho, Sung-Yong;Seok, Chang-Woo;Han, Moon-Ki;Ha, Chang-Seung;Park, Cha-Soo;Lee, Hae-Jun;Park, Chung-Hoo
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1420-1421
    • /
    • 2007
  • 기존의 fence전극구조는 ITO구조에 비해 방전전류가 감소함에도 불구하고 휘도가 대폭 감소하여 효율이 떨어지는 것으로 알려져 있다. 따라서 효율 상승을 위하여 다음과 같은 fence구조를 제안하였다. 실험은 reference(Conventional T-전극구조)와 제안된 구조들로 구성되어 있는 4-inch AC-PDP test Panel을 직접 제작하여 discharge current, luminance, luminous efficiency를 측정하여 비교하였다. 제안된 구조들은 방전전류 최대 10%감소, 휘도는 최대 20%증가하였고 효율면에서도 최대 20%의 상승을 보였다.

  • PDF