• 제목/요약/키워드: feed-back control

검색결과 229건 처리시간 0.058초

Buck-Flyback (fly-buck) Stand-Alone Photovoltaic System for Charge Balancing with Differential Power Processor Circuit

  • Lee, Chun-Gu;Park, Jung-Hyun;Park, Joung-Hu
    • Journal of Power Electronics
    • /
    • 제19권4호
    • /
    • pp.1011-1019
    • /
    • 2019
  • In this paper, a buck-flyback (fly-buck) stand-alone photovoltaic (PV) system for charge balancing with a differential power processor (DPP) circuit is proposed. Conventional feed-back DPP converters draw differential feed-back power from the output of a string converter. Therefore, the power is always through the switches and diodes of the string converter. Because of the returning conduction path, there are always power losses due to the resistance of the switch and the forward voltage of the diode. Meanwhile, the proposed feed-back DPP converter draws power from the magnetically-coupled inductor in a string converter. This shortens the power path of the DPP converter, which reduces the power losses. In addition, the extra winding in the magnetically-coupled inductor works as a charge balancer for battery-stacked stand-alone PV systems. The proposed system, which uses a single magnetically-coupled inductor, can control each of the PV modules independently to track the maximum power point. Thus, it can overcome the power loss due to the power path. It can also achieve charge balancing for each of the battery modules. The proposed topology is analyzed and verified using 120W hardware experiments.

Premarin검사를 이용한 무월경환자에서의 시상하부-뇌하수체의 기능평가 (Evaluation of the Hypothalamic-pituitary Function by Premarin Test for the Patients of Amenorrhea)

  • 이진우;나종구
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제11권2호
    • /
    • pp.17-25
    • /
    • 1984
  • Hypothalamic-pituitary function in patients of 6 selected groups of amenorrhea was evaluated by performing premarin test. Selected amenorrheic patients were divided into 6 groups of Turner's syndrome(5), adrenogenital syndrome(3), Sheehan's syndrome(4), moderate hyperprolactinemia(3), severe hyperprolactinemia(9) and functional oligoamenorrhea(9) the diagnoses of which were performed according to modified our own protocol for management of amenorrheic patients. As control 20 normally cycling women in mid follicular phase determined by their symptothermal charts during last 6 months designed by WHO were compared. The premarin test which is one of the tests evaluating the hypothalamic-pituitary function by the principle of negative and positive feed back effect's of estrogen was performed by injecting 20 mg of premarin in volus intravenously. The levels of serum LH before, 24, 48, 72, 96 and 120 hours after injection of premarin were measured by double antibody technique radioimmunoassay the reagents of which were supplied by WHO. The results were as follows: 1. Both negative and positive feed back effects by exogenous estrogen were well preserved even in the patients of gonadal dysgenesis although the baseline levels were much higher than normal. 2. In the patients of Sheehan's syndrome one could observe the minimal response of feed back effect in the case with minimal pituitary function. 3, Androgens in adrenogenital syndrome and prolactin in hyperprolactinemia may suppress mainly the positive feed back effect rather than the negative one. The suppressive effect can be abolished by proper treatments which can eliminate those suppressive hormones. 4. This premarin test may be beneficial for predicting the result of clomiphene in ovulation induction.

  • PDF

A Fully Digital Controlled Fly-back Single Stage Power Supply Unit for the Wireless Dimming System of LED Lightings

  • Oh, Yongseung;In, Chigak;Cho, Kyumin
    • 한국정보기술학회 영문논문지
    • /
    • 제9권2호
    • /
    • pp.75-87
    • /
    • 2019
  • This paper presents a fully digital controlled power supply unit for the wireless controlled dimmable LED lighting system. The proposed power supply designed using a fly-back converter, which is directly controlled by a microprocessor. Although the proposed circuit does not sense the AC input current and has not AC input voltage feed-forward, it can achieve a high power factor. The proposed power supply directly regulates the output power for LED loads using the PWM and PFM control of the fly-back converter without additional regulator. For a wireless remote control function, the Zigbee modem is equipped in the proposed power supply. A prototype set-up has been built and tested. Through the experiment with a prototype set-up, the usefulness of the proposed power supply is verified.

싸이리스터에 의한 전동기 속도의 자동제어에 관한 연구 (Speed Control of the Motor in Automatic Control Using the Thyristor)

  • 박민호
    • 전기의세계
    • /
    • 제19권2호
    • /
    • pp.6-11
    • /
    • 1970
  • For the variable speed in automatic control, this paper describes, at first, performance equations of an induction motor which has the free rotating stator. This motor with rotating stator has a speed control factor itself by equivalent variable frequency in stator side. Secondly, an additional invertor source on the rotor slip ring serves the purpose of improving the speed control factor. The advantages decribed above permit to control the speed continuosly from zero to maximum allowable speed with low energy of thyristor a feed-back device may be used for speed stabilization under variable load.

  • PDF

System dynamics of scanning tunneling microscope unit

  • Yamada, Hikaru;Endo, Toshiro;Tsunetaka-Sumomogi;Fujita, Toshizo;Morita, Seizo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1988년도 한국자동제어학술회의논문집(국제학술편); 한국전력공사연수원, 서울; 21-22 Oct. 1988
    • /
    • pp.794-797
    • /
    • 1988
  • G. Binnig and H. Rohrer introduced the Scanning Tunneling Microscope (STM) in 1982 and developed it into a powerful and not to be missed physical tool. Scanning tunneling Microscopy is a real space surface imaging method with the atomic or subatomic resolution in all three dimensions. The tip is scanned over the surface by two piezo translators mounted parallel (X-piezo and Y-piezo) to the surface and perpendicular to each other. The voltage applied to the third piezo (Z-piezo) translator mounted perpendicular to the surface to maintain the tunneling current through the gap at a constant level reflects then the topography of the surface. The feed back control loop for the constant gap current is designed using the automatic control technique. In the designing process of the feed back loop, the identification of the gap dynamics is very complex and has difficulty. In this research, using some suitable test signals, the system dynamics of the gap including the Z-piezo are investigated. Especially, in this paper, a system model is proposed for the gap and Z-piezo series system. Indicial response is used to find out the model. The driving voltage of the Z-piezo and the tunneling current are considered as input and output signals respectively.

  • PDF

직업성 만성요통 환자와 정상성인에서 동요 유발 시 근 수축 개시시간 비교 (Comparison of Muscle Onset Times During Perturbation Between Subjects With and Without Work-Related Chronic Low Back Pain)

  • 노경선;권오윤;이충휘;전혜선
    • 한국전문물리치료학회지
    • /
    • 제14권2호
    • /
    • pp.21-28
    • /
    • 2007
  • The purpose of this study was to compare the onset times of muscle activities and the order of muscle firing in erector spinae, multifidus, rectus abdominis and biceps brachii during perturbation between subjects with and without work-related chronic low back pain (LBP). Twenty-nine subjects, 14 with and 15 without LBP, participated in this study. The muscle responses were measured by surface EMG (electromyography) during perturbation in eye opened and eye closed conditions. The EMG onset times of the erector spinae, multifidus, rectus abdominis and biceps brachii were similar between groups in eye closed condition. But the onset times of the erector spinae, multifidus, rectus abdominis were significantly delayed in subjects with LBP in eye opened condition. The results provide an evidence for impaired feed-forward control of the trunk muscles in subjects with LBP. Further studies are needed to identify whether the impaired feed-forward control of the trunk muscles is the contributing factor to LBP.

  • PDF

SEPIC을 이용한 고역율 정류회로의 과도응답특성 개선 (Improvement of transient characteristics of SEPIC rectifier)

  • 정석언;이교범;현동석;송중호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.525-529
    • /
    • 2001
  • A pulse frequency control(PFM) method for single-phase SEPIC-type rectifier is described in this paper. In the SEPIC rectifier, a relationship between the output power and the respective switching frequency is investigated to establish the control scheme of PFM. The propsed control method is provided with a feed-forward control loop of the output load as well as a feed-back control loop of the output voltage. The simulation results show good dynamic responses and unity power-factor operation.

  • PDF

BALL-HOOP시스템의 위치 제어에 관한 연구 (A study of the position control of the BALL-HOOP system)

  • 주해호;이훈구
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1989년도 한국자동제어학술회의논문집; Seoul, Korea; 27-28 Oct. 1989
    • /
    • pp.282-285
    • /
    • 1989
  • This paper presents a new algorithm for position control of the BALL-HOOP system driven by th D.C. servo motor-through the micro computer simulation. The Stale Feed back + PID control algorithm is proposed. This algorithm performs that the settling time is faster and overshoot is decreased more remarkably than the PID and the State Feedback algorithm alone. In this simulation the difference equations are used to calculate the output of the control system.

  • PDF

適應制御裝置에 關한 硏究 (A Study of the Adaptive Control System)

  • 하주식;최경삼;김승호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제3권1호
    • /
    • pp.19-31
    • /
    • 1979
  • Recently the adaptive control system, which keeps the control system always optimal by adjusting the control parameters automatically according to the variations of the plant parameters, have become very important in the field of control engineering. The adaptive control systems are usally composed of the plant identification, the decision of the optimal control parameters, and the adjustment of the control parameters. This paper deals with a method of the adaptive control system when PI or PID controller is used in the feed back control system. Its controlled object (the plant) is assumed to be described by the transfer function of $\frac{ke^{-LS}}{1+TS}$ where k, T and L are steady state gain, time constant and pure dead time respectively, and their values are variable in accordance with the change of environmental circumstance. It has been known that a pseudo-random binary signal is quite effective for the measurement of an impulse response of a plant. In adaptive control systems, however, the impulse response itself is not appropriate to determine the control parameters. In this paper, the authors propose a method to estimate directly the parameters of the plant k, T and L by means of the correlation technique using 3 level M-sequence signal as a test signal. The authors also propose a method to determine the optimal parameters of the PI or PID controller in the sense of minimizing the square integral of the control error in the feed back control system, and the values of the optimal parameters are computed numerically for various values of T and L, and the results are examined and compared with those of the conventional methods. Finally the above-mentioned two methods are combined and an algorithm to struct an adaptive control system is suggested. The experiments for the indicial responses by means of both the model of the temperature control system using SCR actuater and the analog simulations have shown good results as expected, and the effectiveness of the proposed method is verified. The M-sequence generator and the time delay circuit, which are manufactured for the experiments, are operated in quite a good condition.

  • PDF

Nonlinear Adaptive Control of Fermentation Process in Stirred Tank Bioreactor

  • Kim, Sang-Bong;Kim, Hak-Kyeong;Soo, Jeong-Nam;Nguyen, Tan-Tien
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.74.3-74
    • /
    • 2001
  • This paper proposes a nonlinear adaptive controller based on back-stepping method for tracking reference substrate concentration by manipulating dilution rate in a continuous baker´s yeast cultivating process in stirred tank bioreactor. Control law is obtained from Lyapunov control function to ensure asymptotical stability of the system. The Haldane model for the specific growth rate depending on only substrate concentration is used in this paper. Due to the uncertainty of specific growth rate, it has been modified as a function including the unknown parameter with known bounded values. The substrate concentration in the bioreactor and feed line are measured. The deviation from the reference is observed when the external disturbance such as the change of the feed is introduced to the system ...

  • PDF