• Title/Summary/Keyword: fault inspection

검색결과 115건 처리시간 0.022초

A semi-supervised interpretable machine learning framework for sensor fault detection

  • Martakis, Panagiotis;Movsessian, Artur;Reuland, Yves;Pai, Sai G.S.;Quqa, Said;Cava, David Garcia;Tcherniak, Dmitri;Chatzi, Eleni
    • Smart Structures and Systems
    • /
    • 제29권1호
    • /
    • pp.251-266
    • /
    • 2022
  • Structural Health Monitoring (SHM) of critical infrastructure comprises a major pillar of maintenance management, shielding public safety and economic sustainability. Although SHM is usually associated with data-driven metrics and thresholds, expert judgement is essential, especially in cases where erroneous predictions can bear casualties or substantial economic loss. Considering that visual inspections are time consuming and potentially subjective, artificial-intelligence tools may be leveraged in order to minimize the inspection effort and provide objective outcomes. In this context, timely detection of sensor malfunctioning is crucial in preventing inaccurate assessment and false alarms. The present work introduces a sensor-fault detection and interpretation framework, based on the well-established support-vector machine scheme for anomaly detection, combined with a coalitional game-theory approach. The proposed framework is implemented in two datasets, provided along the 1st International Project Competition for Structural Health Monitoring (IPC-SHM 2020), comprising acceleration and cable-load measurements from two real cable-stayed bridges. The results demonstrate good predictive performance and highlight the potential for seamless adaption of the algorithm to intrinsically different data domains. For the first time, the term "decision trajectories", originating from the field of cognitive sciences, is introduced and applied in the context of SHM. This provides an intuitive and comprehensive illustration of the impact of individual features, along with an elaboration on feature dependencies that drive individual model predictions. Overall, the proposed framework provides an easy-to-train, application-agnostic and interpretable anomaly detector, which can be integrated into the preprocessing part of various SHM and condition-monitoring applications, offering a first screening of the sensor health prior to further analysis.

비파괴 검사 시스템의 융합 적용 사례 (The Convergence Application Example of Non-destructive Inspection System)

  • 이정익
    • 한국융합학회논문지
    • /
    • 제8권3호
    • /
    • pp.191-197
    • /
    • 2017
  • 본 개발은 중간 크기 미만의 외형 결함을 검출함에 있어 X-Ray 광원을 사용하는 비파괴 장비이다. 본 연구개발물의 차별성은 X-Ray광원을 이용 중소형 생산제품들의 외부결함 유무를 실시간 검사할 수 있으며 표면 방사선 누설선량에 있으면서 검사 속도제어가 가능하다. 이를 소프트웨어로 해결하였다. 또한 작업 중 작업자 안전을 위해 도어 차단이 가능하고 동시에 장비 내부 구동 영상의 획인이 가능하다는 점이다. 이런 원리로 현재는 중소형 부품에서부터 크게는 컨테이너와 같은 검사시스템의 기반 기술로 활용이 가능하다. 본 연구는 자동차 산업 외에 다른 다양한 비파괴 시장 산업에 큰 영향을 미칠 것이다. 마지막으로 개발된 비파괴 장비는 $0.2Sv{\mu}$ 하에서 제어된다는 사실은 아주 중요한 사실이다.

스마트 센서를 이용한 선박용 승강기 실시간 모니터링 시스템의 구현 (Implementation of Real-time Monitoring System for Marine Elevator using Smart Sensors)

  • 이우진;임재홍
    • 한국멀티미디어학회논문지
    • /
    • 제19권2호
    • /
    • pp.405-410
    • /
    • 2016
  • Elevator industry is a field that is mechanical, electrical and electronic technology and constantly requires inspection and maintenance considering various applications and various types. Recently, various elevator control and monitoring technologies with IT are developing for elevators on land. But technologies with IT have been hardly done in marine elevator that is consistently assured safety and reliability of life cycle for its parts in poor environment. In this paper, we implemented embedded main controller, floor controller and car controller that meet the requirements and use NMEA network protocol by analyzing home and abroad integrated elevator operation and management systems. Especially, we secured reliability of maintenance by real-time fault diagnosis and control that was implemented with limit switch, gyro sensor, temperature/humidity/barometric pressure sensor and fire detection sensor thinking over the environmental conditions of terrestrial and marine elevator.

IEC 60364 적용 및 TN-S 시스템에서 보호 도체 산정 및 적정성에 관한 연구 (Assessment Method and Calculations for Protective Conductor of TN-S System and IEC 60364 Application)

  • 김기현;이주철;최영규;김한수;이영철
    • 조명전기설비학회논문지
    • /
    • 제26권2호
    • /
    • pp.86-91
    • /
    • 2012
  • A conductor has been produced according to IEC standard and low voltage electrical facility has been installed according to IEC 60364. So we must comply with international standard for design, construction and inspection. But because of many related and varied standards, it is difficult to apply to design and inspect for electrical equipment. We researched the necessity of design guide which is detailed and systematization from survey. For detailed design guide, we suggest calculation method of protective conductor cross-sectional area at TN-S system according to BS 7671 regulation and KS C IEC 60364 standard.

자동 초음파 신호평가를 위한 비쥬얼도구에 관한 연구 (The Study of Visual Tool for Automated Ultrasonic Examination of the Piping Welds in NPP)

  • 유현주;최성남;김형남;이희종
    • 한국압력기기공학회 논문집
    • /
    • 제6권1호
    • /
    • pp.9-15
    • /
    • 2010
  • This paper describes the Visual Tool for automatic ultrasonic examination that is under developing as a part of the project for development of automatic ultrasonic wave acquisition and analysis program. This tool that is supported by various image processing techniques will be adopted to detect the flaws in the component and piping welds in NPP. Visual Tool will enhance the integrity of nuclear power plant. The object of this paper is to address the Visual Tool which is developing for automatic ultrasonic inspection of welds in NPP.

  • PDF

누설전류측정을 이용한 일반용전기설비의 점검 (Inspection of General Use Electric Installation Using Leakage Current Measuring)

  • 임용배;정종욱;정진수;배석명;조성원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.63-65
    • /
    • 2006
  • A electrical fault is defined as any abnormal condition caused by a reduction in the insulation strength. To define the potential risk of the electric installation, measurement of leakage current has been getting considered, but because the measured leakage current value also contained leakage current by capacitance, the measured value could not be adapted to absolute reference to the installation. Therefore, in this paper, the correlation between the condition of electric installation and leakage current were analyzed. The result focuses on to detect them in a cost efficient way.

  • PDF

퍼지 패턴 분류와 뉴럴 네트워크를 이용한 지능형 유중가스 판정 시스템 (Intelligent Diagnosis System for DGA Using Fuzzy Pattern Classification and Neural Network)

  • 조성민;권동진;남창현;김재철
    • 전기학회논문지
    • /
    • 제56권12호
    • /
    • pp.2084-2090
    • /
    • 2007
  • The DGA (Dissolved Gases Analysis) technique has been widely using for fault diagnosis of the power transformers. Some electric power utility company establishes the criteria of DGA to improve reliability, because of difference of operation environment and design of power transformer. In this paper, we introduce intelligent diagnosis system for DGA result of KEPCO (Korea Electric Power Cooperation). This system can classify patterns type of gases ratio that frequently occurs in recent result of gases analysis using Fuzzy Inference. The classification of Patterns let us know that major causes of gases generation based on type of patterns. Finally, Neural Network based on patterns diagnose transformer. NN was trained using result data of DGA of actually faulted transformers recently. Result of intelligent diagnosis system is right well in comparison with actual inner inspection of transformers.

변압기의 권선변형 검증을 위한 LVI 시험기 개발 (The Development of LVI Tester for WInding Deformation Measurement in Power Transformers)

  • 조국희;김광화;곽희로
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2000년도 학술대회논문집
    • /
    • pp.251-256
    • /
    • 2000
  • The assessment of the condition of a transformer winding which is suspected of having suffered short circuit damage can be difficult. Conventional test such as winding resistance, magnetisation current or insulation resistance will only detect damage if a permanent electrical fault exists. Visual inspection of windings necessitates the removal of oil and in many cases only a very small proportion of the winding can be seen. We describe the characteristics. As the front rise time of recurrent-surge generator pulse less than 1000ns and the peak value of pulse is about 500V, we have the good results of detecting winding deformation in the LVI test of transformers.

  • PDF

초음파 이미지를 이용한 CFRP 복합적층판의 적층결함 평가 (On Evaluation of Stacking Fault in CERP Composite Plates of Using Ultrasonic Images)

  • 임광희;나승우;심재기;양인영
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2003년도 춘계학술발표대회 논문집
    • /
    • pp.121-124
    • /
    • 2003
  • This paper shows shear wave behavior of CFRP(carton fiber reinforced plastics) composite laminates as a polar grid form to evaluate vibration pattern of ultrasonic transducers, which gives measured modelling fundamental contents of nondestructive evaluation. This modelling decomposes the transmission of a linearly polarized wave into orthogonal components through each ply of a laminate. It is found that a high probability shows between the model and measurement system in characterizing lay up of CFRP composite laminates. Also evaluating quantitatively the defects in CFRP laminates who found to be possible of normalized frequency obtained from 2D-FFT technique based on C-scan method. Thus, the technique is proven to be one of the useful means to evaluate any internal defect in CFRP composite laminates.

  • PDF

서울2호선 TCMS 무선지상장치 개발 및 시험결과에 대한 고찰 (The Study about TCMS Wireless Depot Analytical Equipment Development and Test Results at SeoulMetro Line2)

  • 김도훈;서상준;한정수;김철호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.353-362
    • /
    • 2008
  • Operation data and fault data are recorded at the TCMS(Train Control and Monitoring System) of train are very important record for repairs and inspection of train. there are two ways to transfer the data today. one is using memory card and the other is using wireless communications. This paper is proposed about TCMS wireless depot analytical equipment that transfers data recorded in train to depot equipment via wireless method. The TCMS wireless depot equipment configuration is an AP(Access Point) and a central server PC at depot equipment. This method has the advantage of decrease of personnel expenses, collection time and convenience of staffs. This paper is verified about the utility of use, efficient establishment position of an AP at depot, the safety of data receiving, the exactitude of data and the shortening of transmission time. and this equipment is now operating at shin-jeong depot of SeoulMetro.

  • PDF