• Title/Summary/Keyword: fault area

Search Result 802, Processing Time 0.026 seconds

A Study on the method to determine an Area of Severity for Voltage Sag Assessment (순간전압강하 평가를 위한 Area of Severity 구현에 관한 연구)

  • Lee, Kyebyung;Park, Chang-Hyun;Bae, Jong-Il;Lee, Hansang;Cho, Soohwan;Jang, Gilsoo
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.323-324
    • /
    • 2015
  • Voltage sag phenomenon is known as one of the important problems that brought huge economic losses in the modern industry. The voltage sag assessment is to predict an annual expected sag frequency (ESF) at concerned consumers caused by fault in the system. An area of severity (AOS) assessment is defined as a set of the fault positions that can result in the voltage sag bigger than certain level for multi-concerned buses simultaneously. This paper introduces how to determine a method for evaluating the voltage sag performance based on the AOS assessment.

  • PDF

A study on the Placement of Energy Storage System by using Area of Severity Assessment (Area of Severity 평가를 이용한 에너지 저장장치의 위치 결정에 관한 연구)

  • Lee, Kyebyung;Park, Chang-Hyun;Bae, Jong-Il;Lee, Hansang;Cho, Soohwan;Jang, Gilsoo
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.321-322
    • /
    • 2015
  • An area of severity (AOS) assessment is defined as a set of the fault positions that can result in the voltage sag bigger than certain level for sensitive buses simultaneously. Using the AOS assessment, the location of devices for compensating voltage sag can be determined as the site expected to less voltage sag at the sensitive bus. The energy storage system based on the control strategy emulating the traditional synchronous generator can contribute the fault current with fast response. Therefor are of venerability (AOV) can be reduced. The energy storage system installed by the AOS assessment has function which can experience relatively less voltage sag in addition to the conventional role of energy storage.

  • PDF

A Geological and Geomorphological Study on Jeomal Cave (점말동굴 지역의 지형과 지질)

  • Kim, Joo-Whan
    • Journal of the Speleological Society of Korea
    • /
    • no.67
    • /
    • pp.21-34
    • /
    • 2005
  • Jeomal Cave consists of limestone. Soil distribution is very different from mountain area to piedmont area. The Cave developed in a part of the fault valley. The joints controls the low level stream orders in the cave. in this area the geological structure is close relate to the underground water flow. It is certain that the distribution of the clay came from the surface.

Fault Tolerant Channel Allocation Scheme considering Multimedia Service in IMT-2000 (차세대 이동망에서 멀티미디어 서비스를 고려한 FTC 방식)

  • 박상준;이효준;조인숙;김관중;김병기
    • Journal of the Korea Society for Simulation
    • /
    • v.10 no.4
    • /
    • pp.11-20
    • /
    • 2001
  • In the IMT-2000 networks, the model of micro/pico cell is suggested for transmission of multimedia service. Hence, the efficient method is required for processing of mobile calls in micro/pico cell. In the central urban area, mobile calls may be dynamically increased because of many mobile users. And microcel]/picocell size has small size, handover calls will be more increased. Therefore, many of mobile calls is occurred at a cell in the central urban area, so channel requests for these calls will be increased in the call. In this paper, we propose a scheme, FTC(Fault Tolerant Channel allocation) which is the channel management method for hard handover and new call in a mobile cell of central urban area. When available channels in the cell are consumed, the FTC investigates channel states of neighbor cells in the RNC(Radio Network Controller) or BSC (Base Station Center), and provide available channel for mobile call. The ]no scheme is analyzed and compared with existing channel management method by simulation.

  • PDF

A study on the ice and snow loading condition in Taebaek and Sabuk area in Gangwon province for the construction of KEPCO 765kV transmission lines (한전 765 kV 송전선로 건설을 위한 강원도 태백.사북지역 착빙설 하중조건 검토)

  • Park, K.H.;Kim, Y.W.;Won, B.J.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1923-1924
    • /
    • 1996
  • Some part of the route in KEPCO 765kV transmission line being constructed passes through a high mountain area which is 800m above the sea level (Taebaek, Sabuk area in Gangwon province). This area is the top part of Taebaek mountains corresponding to the backbone of korean peninsula and has lots of snow during the winter season because the winter seasonal wind gone up along the mountainside of Taebaek Mts. meets open air of the East sea. KEPCO has experienced 63 faults of T/L between 1968 and 1993 in this area, which is a very serious problem. Especially 154kV Hwang-Ji T/L fault in 1990, 2 was a unprecedented case which needs to be analyzed carefully to take proper measures. After reviewing ice and snow loading conditions and analyzing the fault of Hwang-Ji T/L, we're going to determine the revisement of ice and snow loading condition in this area to increase reliability of 765kV transmission line.

  • PDF

Expected Segmentation of the Chugaryung Fault System Estimated by the Gravity Field Interpretation (추가령단층대의 중력장 데이터 해석)

  • Choi, Sungchan;Choi, Eun-Kyeong;Kim, Sung-Wook;Lee, Young-Cheol
    • Economic and Environmental Geology
    • /
    • v.54 no.6
    • /
    • pp.743-752
    • /
    • 2021
  • The three-dimensional distribution of the fault was evaluated using gravity field interpretation such as curvature analysis and Euler deconvolution in the Seoul-Gyeonggi region where the Chugaryeong fault zone was developed. In addition, earthquakes that occurred after 2000 and the location of faults were compared. In Bouguer anomaly of Chugaryeong faults, the Pocheon Fault is an approximately 100 km fault that is extended from the northern part of Gyeonggi Province to the west coast through the central part of Seoul. Considering the frequency of epicenters is high, there is a possibility of an active fault. The Wangsukcheon Fault is divided into the northeast and southwest parts of Seoul, but it shows that the fault is connected underground in the bouguer anomaly. The magnitude 3.0 earthquake that occurred in Siheung city in 2010 occurred in an anticipated fault (aF) that developed in the north-south direction. In the western region of the Dongducheon Fault (≒5,500 m), the density boundary of the rock mass is deeper than that in the eastern region (≒4,000 m), suggesting that the tectonic movements of the western and eastern regions of the Dongducheon Fault is different. The maximum depth of the fracture zone developed in the Dongducheon Fault is about 6,500 m, and it is the deepest in the research area. It is estimated that the fracture zone extends to a depth of about 6,000 m for the Pocheon Fault, about 5,000 m for the Wangsukcheon Fault, and about 6,000 m for the Gyeonggang Fault.

Fault Detection System Using Spatial Index Structure (공간자료구조를 활용한 단층인식 시스템)

  • Bang, Kap-San
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.1205-1208
    • /
    • 2005
  • By adding user interface to the usual router, an improved functional router is implemented in this paper. Due to the massive amount of spatial data processing, spatial information processing area has been rapidly grown up in recent years based on powerful computer hardware and software development. Spatial index structures are the core engine of geographic information system(GIS). Analyzing and processing of spatial information using GIS has a lot of applications and the number application will be increased in the future. However, study on the under ground is in its infancy due to invisible characteristic of this information. This paper proposes the sub-surface fault detection system using the sub-surface layer information gathered from elastic wave. Detection of sub-surface fault provides very important information to the safety of above and sub-surface man made structures. Development of sub-surface fault detection system will serve as a pre-processing system assisting the interpretation of the geologist.

  • PDF

Development of Induction machine Diagnosis System using LabVIEW and PDA (LabVIEW 기반의 PDA를 이용한 기계 진단 시스템의 개발)

  • Son, Jong-Duk;Yang, Bo-Suk;Han, Tian;Ha, Jong-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.945-948
    • /
    • 2005
  • Mobile computing devices are becoming increasingly prevalent in a huge range of physical area, offering a considerable market opportunity. The focus of this paper is on the development of a platform of fault diagnosis system integrating with personal digital assistant (PDA). An improvement of induction machine rotor fault diagnosis based on AI algorithms approach is presented. This network system consists of two parts; condition monitoring and fault diagnosis by using Artificial Intelligence algorithm. LabVIEW allows easy interaction between acquisition instrumentation and operators. Also it can easily integrate AI algorithm. This paper presents a development environment fur intelligent application for PDA. The introduced configuration is a LabVIEW application in PDA module toolkit which is LabVIEW software.

  • PDF

A Study on Calculation of Line- To-Ground Fault Current Split Factor to Earth in Overhead Transmission Lines (가공송전선 지락시 고장전류의 접지분류계수 산정에 관한 연구)

  • Choi, Jong-Kee;Lee, Won-Kyo;Choi, In-Hyuk;Lee, Sang-Yun;Hwang, Kab-Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.11
    • /
    • pp.1929-1932
    • /
    • 2008
  • In case of a line-to-ground fault at transmission lines, a portion of fault current will flow into the earth through the footings of the faulted tower causing electrical potential rise nearby the faulted tower footings. In this situation, any buried pipelines or structures nearby the faulted tower can be exposed to the electrical stress by earth potential rise. Although many research works has been conducted on this phenomena, there has been no clear answer of the required separation distance between tower footings and neary buried pipeline because of its dependancy on the soil electrical charactersics of the concerned area and the faulted system.

A Case Study of Analysis and Design for the Tunnel Stablization in Fault Zone by FRP Reinforced Grouting Method (FRP보강 그라우팅에 의한 단층대의 터널 안정성 분석 및 설계 사례 연구)

  • 박종호;최용기;박영목;권오엽;이재봉
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.03a
    • /
    • pp.121-128
    • /
    • 2001
  • This is a case study of stability analysis and reinforcement design for the tunnel where the collapse of the entrance slops occured along the fault zone developed in the bed rock. According to the site investigation, the main factor of sliding is the influence of fault gouge and heavy rainfall. Considering the in-situ condition, the versatile reinforcement methods is needed, and so the close investigation on the site area was accompanied with the stability analysis of tunnel and slops. The FRP(Fiberglass reinforced plastic) grouting method improved the defect of Steel Umbrella Arch Method, such as oxidation, low work efficiency, the material's heavy weight, is adapted as the reinforcement methods.

  • PDF