• Title/Summary/Keyword: fault area

Search Result 802, Processing Time 0.024 seconds

Assessing landslide susceptibility along the Halong - Vandon expressway in Quang Ninh province, Vietnam: A comprehensive approach integrating GIS and various methods

  • Nguyen-Vu Luat;Tuan-Nghia Do;Lan Chau Nguyen;Nguyen Trung Kien
    • Geomechanics and Engineering
    • /
    • v.37 no.2
    • /
    • pp.135-147
    • /
    • 2024
  • A GIS-based landslide susceptibility mapping (LSM) was carried out using frequency ratio (FR), modified frequency ratio (M-FR), analytic hierarchy process (AHP), and modified analytic hierarchy process (M-AHP) methods to identify and delineate the potential failure zones along the Halong - Vandon expressway. The thematic layers of various landslide causative factors were generated for modeling in GIS, including geology, rainfall, distance to fault, distance to road, slope, aspect, landuse, density of landslide, vertical relief, and horizontal relief. In addition, a landslide inventory along the road network was prepared using data provided by the management department during the course of construction and operation from 2017 to 2019, when many landslides were documented. The validation results showed that the M-FR method had the highest AUC value (AUC = 0.971), which was followed by the FR method with AUC = 0.961. The AUC values were 0.939 and 0.892 for the M-AHP and AHP methods, respectively. The generated LSM obtained from M-FR method classified the study area into five susceptibility classes: very low (0), low (0-1), moderate (1-2), high (2-3), and very high (3-4) classes, which could be useful for various stakeholders like planners, engineers, designers, and local public for future construction and maintenance in the study area.

A Study on the Waste Incinerator Location Problem in Seoul (서울시 쓰레기 소각장 입지에 관한 연구)

  • 이금숙;이희연
    • Journal of the Korean Regional Science Association
    • /
    • v.14 no.1
    • /
    • pp.91-107
    • /
    • 1998
  • Waste disposal problem is one of the most important social welfare indicators in urban area, because the volume of waste generated from urban area is remarkable. So far most waste of Seoul has been disposed at landfills. However, this landifill disposal method is confronted with several difficulties in recent. As public concern on environmental problem increases and autonomy system is settled down, local community people of the landfills refuse to receive the waste produced other places any more. It brought reginal confliction problem between waste sending and receiving by refusing to accept waste from certain region. Furthermore, it is difficult to find another place to fill up the waste, while the existing landfiis is reached at the limit in the near future. In terms of environmental aspects landfill method is not the best way to dispose waste. It contaminates the soil and ground/underground water by leaking water containing many serious pollutants as well as offensive oder. In terms of equity, this waste disposal method is not fair. Environmental pollution causes damage to residence near to the landfills, while the waste produced other places. In order to satisfy the equity aspect, the waste generated a region should be disposed within the region. Incineration of Waste has been provided as the alternative. Government plans to construct waste incinerator in every anatomy, so the waste produced by local community is disposed within their local autonomous area. However, the location decision is not easy, since waste incinerator is one of the facilities to the community people. We can not apply the existing location models for this problem, because they show strong NIMBY phenomenon for the location. The location of waste incinerator should be determined very carefully with consideration of various location factors and criteria. This study proposes a methodology for determining the location of the waste incinerators by utilizing GIS, which is a power research tool for location decision where various geographical factors related. We drive the location factors which should be considered in the determination of waste incinerators. They involve environmental, socio-economic, and institutional factors. In first, we eliminate the area which is located within the environmental location criteria such as slope, fault line, distance to river, and then eliminate ares which is conflict with the social and institutional criteria.

  • PDF

Delineation of a fault zone beneath a riverbed by an electrical resistivity survey using a floating streamer cable (스트리머 전기비저항 탐사에 의한 하저 단층 탐지)

  • Kwon Hyoung-Seok;Kim Jung-Ho;Ahn Hee-Yoon;Yoon Jin-Sung;Kim Ki-Seog;Jung Chi-Kwang;Lee Seung-Bok;Uchida Toshihiro
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.1
    • /
    • pp.50-58
    • /
    • 2005
  • Recently, the imaging of geological structures beneath water-covered areas has been in great demand because of numerous tunnel and bridge construction projects on river or lake sites. An electrical resistivity survey can be effective in such a situation because it provides a subsurface image of faults or weak zones beneath the water layer. Even though conventional resistivity surveys in water-covered areas, in which electrodes are installed on the water bottom, do give high-resolution subsurface images, much time and effort is required to install electrodes. Therefore, an easier and more convenient method is sought to find the strike direction of the main zones of weakness, especially for reconnaissance surveys. In this paper, we investigate the applicability of the streamer resistivity survey method, which uses electrodes in a streamer cable towed by ship or boat, for delineating a fault zone. We do this through numerical experiments with models of water-covered areas. We demonstrate that the fault zone can be imaged, not only by installing electrodes on the water bottom, but also by using floating electrodes, when the depth of water is less than twice the electrode spacing. In addition, we compare the signal-to-noise ratio and resolving power of four kinds of electrode arrays that can be adapted to the streamer resistivity method. Following this numerical study, we carried out both conventional and streamer resistivity surveys for the planned tunnel construction site located at the Han River in Seoul, Korea. To obtain high-resolution resistivity images we used the conventional method, and installed electrodes on the water bottom along the planned route of the tunnel beneath the river. Applying a two-dimensional inversion scheme to the measured data, we found three distinctive low-resistivity anomalies, which we interpreted as associated with fault zones. To determine the strike direction of these three fault zones, we used the quick and convenient streamer resistivity.

Case Study on the Failure Causes of Gneiss Slope Occurred Tension Crack (편마암비탈면에서 인장균열 파괴원인 사례 연구)

  • Chun, Byungsik;Noh, Insoo;Kong, Jinyoung;Kim, Juhyong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.11
    • /
    • pp.27-35
    • /
    • 2012
  • The discontinuity of rock is one of important elements that have impact on the dynamic movement of rock. A slope made of gneiss has complicated geological structure because of the gneiss forming process through metamorphism covering wide range and the anisotropic structure with foliation. In this study, before cutting slope, the rock of slope had been found as a good quality by the boring test. But during construction tension cracks had occurred in the section with 170m length during large-scale excavation work with depth more than 20m. Ground surface geological investigation, boring exploration, resistivity logging and borehole image processing had been done to find the causes of the tension crack. It was possible to estimate the scale of fault existing in large area through resistivity logging and geological investigation. Large scale slickenside and fault clay had been found as the result of comprehensive analysis.

Diagnosing Multiple Faults using Multiple Context Spaces (다중 상황공간을 이용한 다중 오류의 고장 진단)

  • Lee, Gye-Sung;Gwon, Gyeong-Hui
    • The Transactions of the Korea Information Processing Society
    • /
    • v.4 no.1
    • /
    • pp.137-148
    • /
    • 1997
  • Diagnostic problem solving is a major application area of knowledge-based systems research. However, most of the current approaches, both heuristic and model-based, are designed to identify single faults, and do not generalize easily to multiple fault diagnosis without exhibiting exponential behavior in the amount of computation required. In this paper, we employ a decomposition approach based on system configuration to generate an efficient algorithm for multiple fault diagnosis. The basic idea of the algorithm is to reduce the inherent combinatorial explosion that occurs in generating multiple faults by partitioning the circuit into groups that correspond to output measurement points. Rules are multiple faults by partitioning the circuit into groups that correspond to output measurement points. rules are developed for combining candidates from individual groups, and forming consistent sets of minimal candidates.

  • PDF

A Study of Parallel Operation of Module Power using CAN Communication (CAN통신을 이용한 모듈전원의 병렬운전에 관한 연구)

  • Park, Seong-Mi;Lee, Sang-Hyeok;Park, Sung-Jun;Lee, Bae-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.8
    • /
    • pp.3603-3609
    • /
    • 2011
  • In this paper, we proposes new load-sharing algorism for equal current division using CAN communication. Proposed algorithm is different from conventional analog method, it performed strong Load-sharing using bi-direction high speed communication. Each modules constitution on independence controller (voltage controller, electric current controller). In parallel system prototype, each module have controller and performed load-sharing according to master module integral value. Also additional controller use for getting each module situations that fault situation of module and fault locate of module. we implemented high efficient load-sharing and redundancy. In this paper, we verify the validity of proposed algorithm using PSIM program and prototype.

Sound Monitoring System of Machining using the Statistical Features of Frequency Domain and Artificial Neural Network (주파수 영역의 통계적 특징과 인공신경망을 이용한 기계가공의 사운드 모니터링 시스템)

  • Lee, Kyeong-Min;Vununu, Caleb;Lee, Suk-Hwan;Kwon, Ki-Ryong
    • Journal of Korea Multimedia Society
    • /
    • v.21 no.8
    • /
    • pp.837-848
    • /
    • 2018
  • Monitoring technology of machining has a long history since unmanned machining was introduced. Despite the long history, many researchers have presented new approaches continuously in this area. Sound based machine fault diagnosis is the process consisting of detecting automatically the damages that affect the machines by analyzing the sounds they produce during their operating time. The collected sound is corrupted by the surrounding work environment. Therefore, the most important part of the diagnosis is to find hidden elements inside the data that can represent the error pattern. This paper presents a feature extraction methodology that combines various digital signal processing and pattern recognition methods for the analysis of the sounds produced by tools. The magnitude spectrum of the sound is extracted using the Fourier analysis and the band-pass filter is applied to further characterize the data. Statistical functions are also used as input to the nonlinear classifier for the final response. The results prove that the proposed feature extraction method accurately captures the hidden patterns of the sound generated by the tool, unlike the conventional features. Therefore, it is shown that the proposed method can be applied to a sound based automatic diagnosis system.

Diagnosis of Induction Motor Faults Using Inverter Input Current Analysis (인버터 입력전류 분석을 이용한 유도전동기 고장진단)

  • Han, Jungho;Song, Joong-Ho;Choi, Kyu-Hyoung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.492-498
    • /
    • 2016
  • It is well known that since abrupt faults in induction motors tend to lead to subsequent faults and deterioration of the drive apparatus, motor faults may lead to several operating restrictions, such as security problems and economic loss. A lot of research has been done in the area of diagnosis to detect machine faults and to prevent catastrophic hazards in the motor drive system. This paper presents a new method of motor current signature analysis in which the DC-link current of the inverter-driven induction motor system, where a single current sensor is employed instead of three AC current sensors, is measured, and fast Fourier transform analysis is performed. This proposed method makes it possible to easily discern and clearly separate the motor fault current signature from the normal operation current flowing through the stator and rotor windings.

The Accident Hazards and Properties of the Surface Leakage Current on the Polymer Insulation caused by Salt-water and Dust (염수 및 분진에 의한 고분자 절연물의 표면누설전류 특성과 사고 위험성)

  • Kim, Young-Seok;Shong, Kil-Mok;Jung, Jin-Su;Jung, Jong-Wook;Kim, Sun-Gu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.8
    • /
    • pp.129-135
    • /
    • 2007
  • It is necessary to study on the prevention and the management of electrical facilities because the electrical fault took place at the dust occurrence area due to environmental pollution. In particular, the dust accumulates easily on insulation material which is exposed an external long time. Therefore, we measured surface leakage current and surface variation of insulation material due to the dust and salt-water. From the results, the surface of bakelite is bad effect for salt-water than other material. The surface leakage current increases by repeated salt-water pollution and the surface of material is carbonized with arc occurrence. Also, it is need to variation of surface coating and shape of material to repress a leakage current on electrical material.

The Switch Installation Criteria For Satisfying Future Reliability Goal (향후 신뢰도 목표를 만족하는 개폐기 설치 기준 제시)

  • Jo, Nam-Hun;O, Jeong-Hwan;Ha, Bok-Nam;Lee, Heung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.9
    • /
    • pp.433-440
    • /
    • 2002
  • The addition of switches to a distribution feeder does, in general, increase reliability by decreasing the duration of the outage of many to the customers on the feeder. To cover its service area so that feeder-level delivery reaches sufficiently close to all customers, feeders typically split their routes many times, in what is often called a lateral feeder. It is interesting to note, however, that the effectiveness of a switch is very much dependent on the types of lateral feeder. The types of lateral are classified into two types. The first is loop lateral feeder that can connect its load to an adjacent feeder through a tie line in case that a fault occurs in its feeder and it is laid out so that every feeder has complete fault backup through re-switching of its loads to other sources like a main feeder The second is the radial lateral feeder cannot connect its load to an adjacent line, no provision is made for contingency backup of feeders. There are no other circuits in the radial lateral feeder form which to restore power. In this study, we evaluate the effectiveness of a switch installation between on the radial and loop lateral feeders to increase reliability by decreasing the duration of the outage. These results can help power utility to design the switch layouts on the radial and loop lateral feeder system.