• Title/Summary/Keyword: fast response

Search Result 1,786, Processing Time 0.035 seconds

Development of a Fast-Response $CO_2$ Analyzer using NDIR Technique and Its Application to SI Engine (비분산 적외선 흡수법을 이용한 고속응답 $CO_2$ 분석기의 제작 및 엔진 적용에 관한 연구)

  • Lee, Jae-Young;Min, Kyoung-Doug
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.6
    • /
    • pp.102-107
    • /
    • 2007
  • A fast response $CO_2$ ($fCO_2$) analyzer for real-time measurement of carbon dioxide concentration during transient states of internal combustion engines has been developed. This analyzer uses non-dispersive infrared absorption (NDIR) technique for measuring $CO_2$ concentration and Kalman filter for removing noise components from output signals. The analyzer has good linearity, repeatability and drift with a response time of 11 ms; it is sufficiently fast to detect $CO_2$ concentration during transient states of internal combustion engines. The $fCO_2$ analyzer was used to measure transient $CO_2$ concentration of exhaust gas of the SI engine with a standard gas analyzer, and the signal of the $fCO_2$ analyzer was compared to that of the standard gas analyzer. The two concentrations were well matched during the steady state, and the $fCO_2$ analyzer could measure the variations of $CO_2$ concentration during the transient state.

Development of Fast-Response Portable NDIR Analyzer Using Semiconductor Devices

  • Kim, Woo-Seok;Lee, Jong-Hwa;Park, Young-Moo;Yoo, Jai-Suk;Park, Kyoung-Seok
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.12
    • /
    • pp.2099-2106
    • /
    • 2003
  • In this paper, a novel fast response NDIR analyzer (FRNDIR), which uses an electrically pulsed semiconductor emitter and dual type PbSe detector for the PPM-level detection of carbon dioxide (CO$_2$) at a wavelength of 4.28 $\mu\textrm{m}$, is described. Modulation of conventional NDIR energy typically occurs at 1 to 20 Hz. To achieve real time high-speed measurement, the new analyzer employs a semiconductor light emitter that can be modulated by electrical chopping. Updated measurements are obtained every one millisecond. The detector has two independent lead selenide (PbSe) with IR band pass filters. Both the emitter accuracy and the detector sensitivity are increased by thermoelectric cooling of up to -20 degrees C in all semiconductor devices. Here we report the use of semiconductor devices to achieve improved performance such that these devices have potential application to CO$_2$ gas measurement and, in particular, the measurement of fast response CO$_2$ concentration at millisecond level.

Evaluation of Demerit-CUSUM Control Chart Performance Using Fast Initial Response (FIR을 이용한 Demerit-CUSUM 관리도의 수행도 평가)

  • Kang, Hae-Woon;Kang, Chang-Wook;Baik, Jae-Won;Nam, Sung-Ho
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.32 no.1
    • /
    • pp.94-101
    • /
    • 2009
  • Complex Products may present more than one type of defects and these defects are not always of equal severity. These defects are classified according to their seriousness and effect on product quality and performance. Demerit systems are very effective systems to monitoring the different types of defects. So, classical demerit control chart used to monitor counts of several different types of defects simultaneously in complex products. S.M. Na et al.(2003) proposed the Demerit-CUSUM for the improvement of the demerit control chart performance and Nembhard, D. A. et al.(2001) and G.Y Cho et al.(2004) developed a Demerit control chart using the EWMA technique and evaluated the performance of the control chart. In this paper, we present an effective method for process control using the Demerit-CUSUM with fast initial response. Moreover, we evaluate exact performance of the Demerit-CUSUM control chart with fast initial response, Demerit-CUSUM and Demerit-EWMA according to changing sample size or parameters.

Design Optimization of Linear Actuator for Fast Response of Electromagnetic Engine Valve (과도시간 감소를 위한 전자기 엔진밸브 액츄에이터 형상 최적 설계)

  • Kim, Jin-Ho;Park, Sang-Shin
    • Journal of the Korean Magnetics Society
    • /
    • v.20 no.1
    • /
    • pp.24-27
    • /
    • 2010
  • This paper presents the design optimization of a linear actuator for fast response of electromagnetic engine valve. The optimization is performed using generic algorithm which is one of global search techniques and not highly dependent on either initial conditions or constraints in the solution domain to maximize the mechanical frequency of the armature mass and valve spring stiffness for fast response of the engine valve. In the results, the mechanical frequency is improved by 30 %.

Multi-Phase Buck Converter with Fast Transient Response (빠른 응답을 갖는 멀티페이스 벅 변환기)

  • Lee, Yoon-Jae;Roh, Jeongjin
    • Journal of IKEEE
    • /
    • v.20 no.3
    • /
    • pp.314-317
    • /
    • 2016
  • Recently, efforts to maximize battery life in progress with an increase in the demand for portable devices. In this paper, we propose multi-phase buck converter with fast transient response. Multi-phase buck converter may be used for the output capacitor of small size because the ripple cancellation effect, it is possible to use an inductor having an inductance less. The portable device for quick change from standby mode to active 4-phase design structure was given a fast transient response. The proposed multi-phase buck converter was fabricated using a 0.18 um CMOS process and the supply voltage ranges from 2.7V to 3.3V, the maximum load current is 500mA and settling time is 10us.

Study for a Novel Fast Response time Liquid Crystal Operating Mode using Control of Tilt Angle for Nematic Liquid Crystal (네마틱 액정의 틸트 제어를 이용한 새로운 고속응답 액정 모드에 관한 연구)

  • Kim, Sang-Hoon;Kang, Hyung-Ku;Hwang, Jeoung-Yeon;Bae, Yu-Han;Kim, Young-Hwan;Seo, Dae-Shik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.181-184
    • /
    • 2005
  • In this paper, we have improved a novel fast response time liquid crystal operating mode using tilt angle in the unique condition by hot-plate equipment. The new control of tilt angle for nematic liquid crystal (NLC) with negative and positive dielectric anisotropy on the rubbed homeotropic polyimide (PI) using baking method by Hot-plate equipment was investigated. LC tilt angle decreased with increasing baking temperature and time. Especially, the low LC tilt angle of positive type NLC (${\Delta}n$>0) on the rubbed homeotropic PI surface by increasing temperature and time was measured. The EO characteristics of the high tilted OCB(HTOCB) mode using control of tilt angle on the homeotropic surface than that of conventional OCB cell can be improved. We suggest that the developed the HTOCB cell using control of tilt angle on the homeotropic surface is a promising technique for the achievement of a fast response time and a high contrast ratio.

  • PDF

SPECTRUM WEIGHTED RESPONSES OF SEVERAL DETECTORS IN MIXED FIELDS OF FAST AND THERMAL NEUTRONS

  • Kim, Sang In;Chang, Insu;Kim, Bong Hwan;Kim, Jang Lyul;Lee, Jung Il
    • Nuclear Engineering and Technology
    • /
    • v.46 no.2
    • /
    • pp.273-280
    • /
    • 2014
  • The spectrum weighted responses of various detectors were calculated to provide guidance on the proper selection and use of survey instruments on the basis of their energy response characteristics on the neutron fields. To yield the spectrum weighted response, the detector response functions of 17 neutron-measuring devices were numerically folded with each of the produced calibration neutron spectra through the in-house developed software 'K-SWR'. The detectors' response functions were taken from the IAEA Technical Reports Series No. 403 (TRS-403). The reference neutron fields of 21 kinds with 2 spectra groups with different proportions of thermal and fast neutrons have been produced using neutrons from the $^{241}Am$-Be sources held in a graphite pile, a bare $^{241}Am$-Be source, and a DT neutron generator. Fluence-average energy ($E_{ave}$) varied from 3.8 MeV to 16.9 MeV, and the ambient-dose-equivalent rate [$H^*(10)/h$] varied from 0.99 to 16.5 mSv/h.

Development of a MEMS-based H2S Sensor with a High Detection Performance and Fast Response Time

  • Dong Geon Jung;Junyeop Lee;Dong Hyuk Jung;Won Oh Lee;Byeong Seo Park;Daewoong Jung
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.4
    • /
    • pp.207-212
    • /
    • 2023
  • H2S is a toxic and harmful gas, even at concentrations as low as hundreds of parts per million; thus, developing an H2S sensor with excellent performance in terms of high response, good selectivity, and fast response time is important. In this study, an H2S sensor with a high response and fast response time, consisting of a sensing material (SnO2), an electrode, a temperature sensor, and a micro-heater, was developed using micro-electro-mechanical system technology. The developed H2S sensor with a micro-heater (circular type) has excellent H2S detection performance at low H2S concentrations (0-10 ppm), with quick response time (<16 s) and recovery time (<65 s). Therefore, we expect that the developed H2S sensor will be considered a promising candidate for protecting workers and the general population and for responding to tightened regulations.

NUMERICAL ANALYSIS OF A SAMPLING MODULE FOR A FAST RESPONSE EXHAUST GAS ANALYZER

  • Kim, W.S.;Lee, J.H.;Yoo, J.S.;Rhee, B.O.;Park, J.I.
    • International Journal of Automotive Technology
    • /
    • v.8 no.2
    • /
    • pp.149-154
    • /
    • 2007
  • The engine behavior in a transient condition is important to not only emission regulations but also fuel economy. A fast response gas analyzer can be a useful tool to investigate exhaust gas in a transient operation. It should be designed to analyze gas concentration with a short time constant by a fast sampling module and an appropriate measuring method for each emission element. In this study, a new fast sampling module is introduced and flow analysis is performed by numerical simulation. The analysis has shown the proper operating condition and the sensitivity of the module for practical application. Calculated flow to the sampling module has $0.5{\sim}4%$ error, while backflow toward the expansion tube is expected when pressure in CP (Constant Pressure) chamber is over 0.6 bar. For a stable supply of flow to the optical cell, sample gas pressure should be in the range, $0.35{\sim}1.90$ bar, when the pressure in the CP camber and the optical cell are 0.2 bar and 0.158 bar, respectively.

Enhancements to the fast recovery Algorithm of TCP NewReno using rapid loss detection (빠른 손실 감지를 통한 TCP NewReno의 Fast Recovery 개선 알고리듬)

  • 김동민;김범준;김석규;이재용
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.7B
    • /
    • pp.650-659
    • /
    • 2004
  • Domestic wireless network environment is changing rapidly while adapting to meet service requirements of users and growth of market. As a result, reliable data transmission using TCP is also expected to increase. Since TCP assumes that it is used in wired networt TCP suffers significant performance degradation over wireless network where packet losses are not always result of network congestion. Especially RTO imposes a great performance degradation of TCP. In this paper, we propose DAC$^{+}$ and EFR in order to prevent performance degradation by quickly detecting and recovering loss without RTO during fast recovery. Compared with TCP NewReno, proposed scheme shows improvements in steady-state in terms of higher fast recovery Probability and reduced response time.