• 제목/요약/키워드: fan room

검색결과 165건 처리시간 0.02초

대구지역 치과기공사의 직무만족 및 작업환경과 이직의도에 관한 연구 (A Study on Job Satisfaction, Working Environment and Turnover Intention of Dental Technicians in Daegu Area)

  • 박홍련;문선정
    • 보건의료산업학회지
    • /
    • 제6권4호
    • /
    • pp.191-204
    • /
    • 2012
  • The purpose of this study was to provide basic data necessary for improvement by closely examining factors of having influence upon dental technicians' turnover. Questionnaire survey was conducted of 204 dental technicians who work at dental hospitals, clinics and dental laboratory rooms in Daegu area. The following conclusions were obtained. The satisfaction with job was high in job position in more than co-representative, in the whole and other task, and in less than 9 hours as for working hours. In the satisfaction with working environment, dissatisfaction was high in women, in the working career with 7~9 years, in chief level as for the job position in charge, in being responsible for porcelain in case of the duty field, and in more than 10 people as for the number of employees. The higher satisfaction with job satisfaction and working environment led to the lower turnover intention. Turnover intention was low in case of having ventilation fan & dust collector desk and in case of being well ventilated inside the workshop. As the above results, it is considered to be necessary for arranging institutional device of protecting dental technicians' health and reducing turnover through improving working environment such as forming comfortable environment of using the dust-collecting facilities and the ventilation facilities, wearing suitable individual protective gear and arranging the rest space.

경북지역 중국인 유학생의 대학급식 선택속성에 대한 중요도와 만족도 분석 (Analyzing the Importance and Satisfaction on the University Foodservice Selection Attributes of Foreign Chinese Students in Gyeongbuk Province)

  • 범명명;배현주
    • 한국식품영양학회지
    • /
    • 제27권1호
    • /
    • pp.128-135
    • /
    • 2014
  • The purpose of this study is to analyze the gap in perceived importance-satisfaction rates of foreign Chinese students regarding the university foodservice selection attributes. All statistical analyses are conducted by the SPSS package program (ver 20.0). The results of the statistical analyses are as follows: The validity of the 22 food service selection attributes is being evaluated via the exploratory factor analysis and then five factors are extracted. The five factors are: 'Factor 1. Cleanness and service quality', 'Factor 2. Food quality and price', 'Factor 3. Physical environment', 'Factor 4. Convenience', and 'Factor 5. Service environment'. According to the results of one-way ANOVA, physical environment showed that significant differences across the periods of residence in Korea and the eating frequency at on campus foodservices. On the other hand, the food quality and price, convenience, and service environment showed that significant differences across the periods of residence in Korea. In addition, according to the Importance-Satisfaction Analysis results, 'ventilation of dining room' is the key aspect that university food service managers should reinforce. In conclusion, in order to increase the customer satisfaction rates, the food service managers should not only improve the quality of food and service but also the physical environments of the food service facility.

가스렌지와 창문위치에 따른 주방 배기성능 예측 (Prediction of the ventilation performance in a kitchen with various locations of gas range and window)

  • 김경환;이재헌;박명식;이대우
    • 설비공학논문집
    • /
    • 제12권1호
    • /
    • pp.75-82
    • /
    • 2000
  • This paper presents the predicted results by CFD technique of air flow and contaminant distribution in a full-scale kitchen opened to a living room, ventilated by a exhaust hood. To analyze the characteristics of the indoor environment, the concept of contaminant index was defined. In this study, the locations of the gas range and the window were chosen as the parameters to investigate the indoor environment. The values of the contaminant index for several layout of the gas range and the window were calculated and compared. When the gas range is installed along the wall with specified window location, its position in relation to the wall has unnoticed effect on contaminant infer. Once the location of the gas range is fixed, the indoor air quality may deteriorate by the proximity of the window to the gas range. This is due to the shorter distance that external fresh air must travel within the kitchen before it reaches the exhaust fan.

  • PDF

호텔 객실의 에너지 효율화를 위한 대기전력 분석 - 체크아웃 상태를 중심으로 - (Analysis of standby power for enhancing the energy efficiency of a hotel guestroom - Focusing on check-out status -)

  • 이준수;구충완
    • 도시과학
    • /
    • 제11권1호
    • /
    • pp.15-20
    • /
    • 2022
  • The issue of hotel energy use is growing more significant as the hotel industry expands. It is important to take into account the electrical installation and space-specific features in a room unit in order to comprehend the energy consumption of a hotel guestroom. In light of this, this study aimed to analyze standby power for enhancing the energy efficiency of a hotel guestroom during check-out status. This study was conducted in three steps: (i) data collection; (ii) analysis of energy consumption patterns; and (iii) analysis of energy efficiency improvement plan. The main findings of this study can be summarized as follows. First, 32.24% of energy was used in fan coil unit) during check-out status. Second, a hotel guestroom had a 4.30% energy saving potential, based on energy consumption patterns during check-out status. This study can contribute to support hotel management to operate guestrooms differently by helping them identify patterns in energy use and realize potential savings.

Helium guard system design for HIAF iLinac cryogenic distribution system

  • Xianjin Wang;Shuping Chen;Wen Jun;Dajun Fan;Liming Zhu;Yanan Lib;Xiaofei Niu;Junhui Zhang
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제25권1호
    • /
    • pp.6-10
    • /
    • 2023
  • 2 K superfluid helium cryogenic system is the crucial component of many large accelerators. When the cryogenic system is operating at 2K@3129Pa, many room-temperature parts are connected to superfluid helium via tubes. Air Leakage in these connections may lead to air contamination of the cryogenic system. Air contamination may cause equipment failure in cryogenic systems and, in extreme cases, render the entire accelerator system inoperable. Helium guard is a technique that guards against air contamination of these sub-atmospheric pressure connections in 2 K superfluid helium cryogenic system. This paper introduces a typical 2 K cryogenic distribution design for large accelerators, and make risk analysis of air contamination. Finally, the analysis of specific leakage points and detailed engineering design are presented, which may be used as a reference when designing of a 2 K superfluid helium cryogenic distribution system.

가혹 환경이 복합재/Ni-Cr 합금 접착전단강도에 미치는 영향 연구 (Effect of Adhesive Shear Strength of CFRP/Ni-Cr Alloy Under Severe Environmental Condition)

  • 조현태;박성민;김민준;황반토;김학인;손명숙;안종기;안지민;최진호;남영우;권진회
    • Composites Research
    • /
    • 제33권5호
    • /
    • pp.275-281
    • /
    • 2020
  • 본 논문에서는 항공기 팬 블레이드에 적용되는 복합재와 금속 간의 접합 구조물에 대한 온도, 습도에 따른 접착제의 물성 변화에 관해 연구하였다. 항공기 운용 시 노출되는 환경 조건을 고려하여 상온 건조(Room Temperature Dry, RTD), 고온 흡습(Evaluated Temperature Wet, ETW), 저온 건조(Cold Temperature Dry, CTD) 세가지 환경에서 강도 시험을 수행하였다. 접착전단강도 시험은 ASTM D3528을 기준으로 수행하였고, 파손 영역에 대한 마이크로 구조 특성을 SEM이미지를 통해 분석하였다. 연구 결과에 따르면 RTD 환경에서의 전단강도 대비하여 ETW 환경에서 72.8% 저하되었으며, CTD 환경에서는 56.5% 증가되었다. 이는 고온 및 수분 흡습이 접착제의 기계적 특성에 큰 영향을 미치는 것을 확인했고, 저온 환경에서는 모재와 접착제 모두 취성의 증가로 인해 접착 전단 강도가 향상된 것으로 분석되었다.

공동주택의 하이브리드 환기시스템 성능평가 연구 (A Study on the Performance of the Hybrid Ventilation System for Apartment Houses)

  • 전주영;김길태;김상희
    • 토지주택연구
    • /
    • 제3권1호
    • /
    • pp.89-96
    • /
    • 2012
  • 본 연구는 공동주택에서 하이브리드 환기시스템의 적용성을 검토하고, 하이브리드 환기시스템의 성능을 향상하기 위해 CFD시뮬레이션을 이용하여 설계방안을 제시하고자 하였다. 연구대상으로는 전용 $51m^2$, $84m^2$의 공동주택을 선정하였으며, 하이브리드 환기시스템은 창틀자연급기와 각실을 덕트로 연결하여 배기하는 시스템(Hybrid 1)과 창틀자연급기와 욕실 거실배기가 혼합된 시스템(Hybrid 2)을 적용하였다. 이때 각 시스템별 배기구의 위치를 변수로 하여 CFD를 수행하였다. $51m^2$, $84m^2$ 모두 Hybrid 2가 Hybrid 1보다 환기효율이 우수한 것으로 나타났으며, 평균공기연령 또한 낮은 것으로 나타났다. Hybrid 1의 경우, 덕트 배기구의 위치가 각 실 입구에 설치하는 것보다 실 안쪽 모서리에 설치하여 기류이동을 많이 유발할 수 있는 유형이 효과적인 것으로 나타났다. Hybrid 2의 경우, 욕실 고정압팬에 덕트를 연결하여 거실중심에 배기구를 설치하는 시스템이 환기효율이 가장 우수한 것으로 나타났다. 그러나 $51m^2$의 경우 Hybrid 2가 Hybrid 1보다 20%의 향상된 환기효율을 나타낸 반면, $84m^2$의 경우는 14%의 향상된 환기효율을 나타내 공동주택 규모에 따른 적정한 하이브리드 환기시스템에 대한 검토가 필요하다.

간이 큐어링 설비를 이용한 큐어링 처리가 장기간 저장 중 고구마의 품질 개선에 미치는 영향 (Application of Simplified Curing Unit for the Extension of Storage Life and Improvement of Physicochemical Quality of Sweet Potatoes during Long-term Storage)

  • 송정화;김성겸;전창후
    • 생물환경조절학회지
    • /
    • 제20권4호
    • /
    • pp.304-310
    • /
    • 2011
  • 본 연구는 기존의 농가 보급형 고구마 저장고에 가열기(본체), 환기팬, 배풍구 팬, 습도 조절을 위한 관으로 구성된 간이 큐어링 설비를 부가시킨 후, 그 효과를 검증하기 위하여 수행되었다. 6일간의 큐어링 처리 기간 동안 저장고 내 기온 및 상대습도는 $32^{\circ}C$, 90%로 설정되었다. 고구마의 저장 기간(6 개월) 동안 1개월에 1회씩 표본을 수집하여 물리화학적 품질을 측정한 결과, 부패율과 부패 정도를 함께 보여주는 McKinney Index는 큐어링 처리구의 경우 0.83%였으며, 큐어링 처리를 하지 않은 대조구의 경우 5.08%였다. 큐어링 처리구의 경도 및 당도, 건물율은 모두 대조구보다 높았으며, 대조구의 표피색이 큐어링 처리구보다 빠르게 변하여 큐어링 처리가 저장기간 동안 고구마의 변색을 지연시켰음을 알 수 있었다. 본 연구를 통하여 간이 큐어링 설비를 이용한 큐어링 처리는 초기 비용이 많이 소모되는 일반 큐어링 설비를 대체하여 고구마의 물리화학적 품질을 증진시킬 수 있으며, 저장 기간을 늘릴 수 있음을 알 수 있었다.

Simulation of Neutron irradiation Corrosion of Zr-4 Alloy Inside Water Pressure reactors by Ion Bombardment

  • Bai, X.D.;Wang, S.G.;Xu, J.;Chen, H.M.;Fan, Y.D.
    • 한국진공학회지
    • /
    • 제6권S1호
    • /
    • pp.96-109
    • /
    • 1997
  • In order to simulate the corrosion behavior of Zr-4 alloy in pressurized water reactors it was implanted (or bombarded) with 190ke V $Zr^+\; and \;Ar^+$ ions at liquid nitrogen temperature and room temperature respectively up to a dose of $5times10^{15} \sim 8\times10^{16} \textrm{ions/cm}^2$ The oxidation behavior and electrochemical vehavior were studied on implanted and unimplanted samples. The oxidation kinetics of the experimental samples were measured in pure oxygen at 923K and 133.3Pa. The corrosion parameters were measured by anodic polarization methods using a princeton Applied Research Model 350 corrosion measurement system. Auger Electron Spectroscopy (AES) and X-ray Photoelectric Spectroscopy (XPS) were employed to investigate the distribution and the ion valence of oxygen and zirconium ions inside the oxide films before and after implantation. it was found tat: 1) the $Zr^+$ ion implantation (or bombardment) enhanced the oxidation of Zircaloy-4 and resulted in that the oxidation weight gain of the samples at a dose of $8times10^{16}\textrm{ions/cm}^2$ was 4 times greater than that of the unimplantation ones;2) the valence of zirconium ion in the oxide films was classified as $Zr^0,Zr^+,Zr^{2+},Zr^{3+}\; and \;Zr^{4+}$ and the higher vlence of zirconium ion increased after the bombardment ; 3) the anodic passivation current density is about 2 ~ 3 times that of the unimplanted samples; 4) the implantation damage function of the effect of ion implantation on corrosion resistance of Zr-4 alloy was established.

  • PDF

소규모 음압터널환기방식 무창자돈사의 최적 환기 요건에 관한 연구 (Necessary Conditions for Optimal Ventilation of Small Windowless Piglet House with Negative Tunnel Ventilating System)

  • 이승주;장동일;;박정식;전상훈;조형제;오권영;장홍희
    • Journal of Biosystems Engineering
    • /
    • 제34권1호
    • /
    • pp.63-68
    • /
    • 2009
  • This study was carried out to determine necessary conditions for optimal ventilation of small windowless piglet house (5.2 (W) ${\times}$ 12.3 (L) ${\times}$ 2.3 (H) m) with negative tunnel ventilating system using CFD (Computational Fluid Dynamics) simulation. The weaning piglet house for this experiment was consisted of 4 rooms (520 (W) ${\times}$ 300 (L) cm), 3 fences (70 (H) cm), 1 air inlet (350 (W) ${\times}$ 2 (H) cm) and 1 exhaust fan (50 (D) cm), and simulated using CFD code, FLUENT. The simulation results for the original weaning piglet house showed ununiform ventilation for each room. Therefore, to uniformly ventilate all rooms, the heights of the air inlet and first fence were modified to 3 cm and 100 cm, respectively. The simulation result f3r the modified weaning piglet house showed uniform ventilation for all rooms and the optimum air inlet velocity of 1.4 m/s.