DOI QR코드

DOI QR Code

Analysis of standby power for enhancing the energy efficiency of a hotel guestroom - Focusing on check-out status -

호텔 객실의 에너지 효율화를 위한 대기전력 분석 - 체크아웃 상태를 중심으로 -

  • 이준수 (인천대학교 도시과학대학 건축학과) ;
  • 구충완 (인천대학교 도시과학대학 도시건축학부)
  • Published : 2022.12.15

Abstract

The issue of hotel energy use is growing more significant as the hotel industry expands. It is important to take into account the electrical installation and space-specific features in a room unit in order to comprehend the energy consumption of a hotel guestroom. In light of this, this study aimed to analyze standby power for enhancing the energy efficiency of a hotel guestroom during check-out status. This study was conducted in three steps: (i) data collection; (ii) analysis of energy consumption patterns; and (iii) analysis of energy efficiency improvement plan. The main findings of this study can be summarized as follows. First, 32.24% of energy was used in fan coil unit) during check-out status. Second, a hotel guestroom had a 4.30% energy saving potential, based on energy consumption patterns during check-out status. This study can contribute to support hotel management to operate guestrooms differently by helping them identify patterns in energy use and realize potential savings.

Keywords

Acknowledgement

본 연구는 과학기술정보통신부의 재원으로 한국연구재단의 지원을 받아 수행한 성과입니다 (No. NRF-2020R1C1C1004147).

References

  1. Chan, E. S. W. (2013), "Managing green marketing: Hong Kong hotel managers' perspective." International Journal of Hospitality Management, Vol. 34, pp.442-461.
  2. Deng, S. and Burnett, J. (2000), "A study of energy performance of hotel buildings in Hong Kong", Energy and Buildings, Vol. 31, No. 1, pp.7.
  3. Deng, S. and Burnett, J. (2002), "Energy use and management in hotels in Hong Kong", International Journal of Hospitality Management, Vol. 21, No. 4, pp.371.
  4. EMSD (Electricity and Mechanical Services Department) (2019),"Hong Kong energy end-use data 2019", EMSD, Hong Kong.
  5. Luan, H. and Leng, J. (2016). "Design of energy monitoring system based on IOT", 2016 Chinese Control and Decision Conference (CCDC), pp.6785-6788.
  6. Michailidis, I. T., Michailidis, P., Alexandridou, K., Brewick, P. T., Masri, S. F., Kosmatopoulos, E. B. and Chassiakoa, A. (2018), "Seismic Active Control under Uncertain Ground Excitation: an Efficient Cognitive Adaptive Optimization Approach.", 2018 5th International Conference on Control, Decision and Information Technologies (CoDIT), pp.847-852.
  7. Molina-Markham, A., Shenoy, P., Fu, K., Cecchet, E. and Irwin, D. (2010), "Private memoirs of a smart meter.", BuildSys '10: Proceedings of the 2nd ACM Workshop on Embedded Sensing Systems for Energy-Efficiency in Building, pp.61-66.
  8. Quinn, M. and Schrier, T. (2011), "Is there a vampire lurking in your hotel? An examination of standby power consumption in Virginia hotel rooms" 16th Graduate Students Research Conference in Hospitality and Tourism (Poster Session).