• Title/Summary/Keyword: facility standard

Search Result 917, Processing Time 0.03 seconds

Supplementation of Regulation on the Offshore Oil Pipeline for Maintenance (해저 송유배관 유지관리를 위한 기준 보완 제시)

  • Kang, Chan-Seong;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.8 no.2
    • /
    • pp.70-81
    • /
    • 2012
  • The study aims to supplement facility management plan and safety regulations & standard of oil pipeline by searching and reviewing related regulation & standard inside and outside of the country. Korean regulation & standard is reviewed based on harbor and fishery design standard of the ministry of maritime affairs and fisheries, general technology standard of oil pipeline safety regulation, gas excavation construction and safety maintenance indicator of Korea gas corporation. Global regulation & standard is reviewed based on U.S standard inspection for offshore pipeline and Europe/Mexico standard inspection for offshore pipeline. The contents of offshore pipeline installation is inserted into pipeline sector for objected facilities of safety inspection regulation & standard and, the standard of safety inspection for offshore pipeline is newly presented into pipeline maintenance part of the planning facilities management with its inspection period and method.

  • PDF

Electromagnetic Wave Shielding Effectiveness Measurement Method of EMP Protection Facility (EMP 방호시설의 전자파 차폐효과 측정 방법)

  • Seo, Manjung;Chi, Seongwon;Kim, Youngjin;Park, Woochul;Kang, Hojae;Huh, Changsu
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.5
    • /
    • pp.548-558
    • /
    • 2014
  • EMP(Electromagnetic Pulse) protection facility was evaluated according to standard of shielding effectiveness. To comply with the standard, transmitting antenna was placed on outside of protection facility and receiving antenna was placed on inside of protection facility. However, measurement is impossible that place does not have enough space between protection facility and external concrete structure. In this paper, we performed a various of tests that put transmitting antenna inside the EMP protection facility in order to find out test method for measuring the shielding effectiveness of electromagnetic wave. Transmitting antenna was placed on inside of the EMP protection facility for measuring the shielding effectiveness to compare and analyze the impact of the position regarding to the transmitting and receiving antenna. As a result of test, in case that transmitting antenna was placed on inside of the EMP protection facility, it was found that test frequency range 10 kHz~1 GHz were occurred overall average difference of ${\pm}4$ dB level.

The Application and Seismic Design Method of Electrical Facility Installed in the Building (건축물에 시설되는 수변전설비의 내진설계 검토사항 및 설계 방안에 대한 고찰)

  • Kim, Gi-Hyun;Lee, Sang-Ick;Bae, Suk-Myong;Cho, Sung-Gook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.8
    • /
    • pp.74-79
    • /
    • 2009
  • In the case of that not considered seismic design at transformer vault which is equipped with many important electrical facilities, the facility is damaged, electrical fire breaks out and another damage may be caused due to earthquake. But seismic design has not yet applied to transformer vault in the country. Regard to seismic design method of electrical facility installed inside the building, the seismic design procedures for electrical facility is presented in this parer, which has been developed by referring "Building design standard" of domestic code and "Manual of seismic design and construction for building electrical facility" in japan. This paper may help engineers perform detail seismic design, construction and reliability inspection of electrical pipes and facilities.

Construction and Functional Tests of Fuel Assembly Mechanical Characterization Test Facility (핵연료집합체 기계적특성 시험시설 구축과 기능시험)

  • Lee, Kang-Hee;Kang, Heung-Seok;Yoon, Kyung-Ho;Yang, Jae-Ho
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.12 no.1
    • /
    • pp.11-16
    • /
    • 2016
  • Fuel assembly's mechanical characterization test facility (FAMeCT) in KAERI was constructed with upgraded functional features such as increased loading capacity, underwater vibration testing and severe earthquake simulation for extended fuel design guideline. This facility is designed and developed to provide out-pile fuel data for accident analysis model and fuel licensing. Functional tests of FAMeCT were performed to confirm functionality, structural integrity, and validity of newly-built fuel assembly mechanical test facility. Test program includes signal check of data acquisition system, load delivering capacity using real-sized fuel assemblies and a standard loading cylindrical rigid specimen. Fuel assembly's lateral bending test was carried out up to 30 mm of pull-out displacement. Limit case axial compression loading test up to 33 kN was performed to check structural integrity of UCPS (Upper Core Plate Simulator) support frame. Test results show that all test equipment and measurement system have acceptable range of alignment, signal to noise ratio, load carrying capacity limit without loss of integrity. This paper introduces newly constructed fuel assembly's mechanical test facility and summarizes results of functional test for the mechanical test equipment and data acquisition system.

A Study on the Service Facilities Plan for APT Community Culture Activation (공동체 문화 활성화를 위한 APT단지 부대복리시설 계획에 관한 연구)

  • Lee, Gwang-Young;Cho, Jin-Man
    • Journal of the Korean housing association
    • /
    • v.19 no.2
    • /
    • pp.55-62
    • /
    • 2008
  • This study is researched to provide design guidelines of service facilities and programs that apartment residents want along with the increased quality of life. This study is signifiant because it sought effective methods to activate the com-munity culture through service facilities in apartment complexes and the design standard and planning direction for residents. The study results are as follows. In the result of the correlations analysis and multiple regression analysis for the importancy of service facilities in apartment complexes, the following orders were considered as important factor; man-ager office, open space, resident community facility, elderly people meeting and activity facility, walking paths, resident athletic facility, a children's playground, library, and rest areas in the complex. and result of the correlations analysis and multiple regression analysis is the following: service facilities whole importance (y) = 1.413$+0.262^*{\times}1$ (manager office importance)$+0.271^*{\times}2$ (open space importance) $+0.185^*{\times}3$ (resident community facility importance) $+0.136{\times}4$ (elderly people meeting and activity facility importance)$+0.036^*{\times}5$ (walking paths importance) $+0.031^*{\times}6$ (resident athletic facility importance) + $(-0.042)^*{\times}7$ (a children's playground importance) + $(-0.045)^*{\times}8$ (library importance) + $(-0.0097)^*{\times}9$ (rest areas importance).

A Study on the Improvement of the Play Areas of Korean Childcare Facilities - Based on a Comparative Analysis of Korean and Foreign Cases and Institutional Frameworks - (국내 어린이집 놀이공간의 개선 방향에 관한 연구 - 국내·외 제도 및 사례의 비교분석을 통하여 -)

  • Lee, Jung-Won;Kim, Daeun;Baek, Sooyeon;Choi, Soyoung
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.36 no.2
    • /
    • pp.53-62
    • /
    • 2020
  • Play areas of childcare facility capable of stimulating the interests of children is extremely important. However, Childcare facility play areas in Korea are often placed in 'leftover' spaces due to institutional inadequacies. As a result, unlike the diverse play areas found in other countries, play areas in Korea have a standard appearance. Therefore, this study aimed to examine the specific causes of the physical differences in the childcare facility play areas of Korea and other countries. This study compared regulations, handbooks and guidelines and examined case studies of childcare facility play areas outside of Korea. Five institutional-level differences related to play areas between countries were identified as a result of this analysis. Suggestions for improvement at the institutional-level were proposed to each of the identified categories. This study focuses on the play areas of childcare facility and suggests directions for the improvement of play areas that are both institutionally and physically realistic.

Study for Reducing Safety Distance by Installing Ammunition Storage Facility in Underground (탄약저장시설 지하화에 따른 안전거리 축소방안 연구)

  • Park, Sangwoo;Jun, Jonghoon;Choi, Hangseok;Park, Young-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.20 no.3
    • /
    • pp.253-260
    • /
    • 2020
  • With increasing interest in an underground-type ammunition storage facility, several design results have been provided recently. However, since not only experts in the tunnel but also military persons in charge of ammunition have not fully understood the safety distance standard, reliable design results are not being produced. In this study, the effective design method of an underground-type ammunition storage facility was provided by analyzing the current safety distance standard. First, the critical safety distances that dominate the size of construction site for underground-type ammunition storage facilities were evaluated, which are the layout of chambers and the configuration of the entrances. Then, the decreasing effect of inter-chamber distance was studied according to the rock type and the storage density of ammunition. In addition, the method of designing tunnels with parallel lines and two-floors was considered for arranging more chambers while complying with the safety distance standards. In particular, numerical simulations were carried out to determine the satisfaction of the safety distance standards when an underground-type ammunition storage facility is composed of two-floor and the decreasing effect of inter-chamber distance according to the inner explosive pressure reduction. Finally, the method to adjust the size of entrances and the path of pressure were studied for decreasing the safety distance at the entrance.

A Study on the Fire Protection System in the Stage (공연장의 소방시설 설치기준의 개선방안에 관한 연구)

  • 장상태;이영재
    • Fire Science and Engineering
    • /
    • v.13 no.4
    • /
    • pp.13-19
    • /
    • 1999
  • Currently, conventional fire prevention facility installation standard is based on the use and size of the domestic theaters. In the study, theaters with 1,900 seats were examined to suggest a suitable method to adapt a better fire preventing system. The proposed systems are as follow. - 100% of backup pressed-water outlet device, considering waterproof pressure for fire prevention facility at the top floor. - The supplement of the side wall type header and a large caliber outlet header for stage open sprinkler. - Subdividing a installation rule for special detector and implementing the latestdetector. - Installation of fire curtain for dividing stage area and auditorium area, and also the method of installation of fire curtain.

  • PDF

Study on the Improvement Plans of Condensation Defect Examples in Apartment Building (공동주택 결로 하자 사례를 통한 개선방안 도출)

  • Oh, Se Min;Park, Sun Hyo;Joung, Kwang Sub
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.2
    • /
    • pp.82-88
    • /
    • 2017
  • There are main issues of defect type that condensation, concrete crack and noise in apartment buildings. Especially, according to the Apartment Defect Dispute Mediation Committee in Korea (ADDMC) at Ministry of Land Infrastructure and Transport in Korea (MLIT), condensation defects are great importance (14 percent) on whole number of reported cases of faults from 2015 in Korea. Most condensation defects have many different causes that take a toll on the resident's life and space. So it is very important to early detection and repair. For preventing the condensation in apartment buildings, there are building codes in Korea such as 'Standard of Method and Judgment for Apartment defect of investigation, Repair cost Estimate'. This research aims to study on the improvement of preventing the condensation aforementioned korea standard. Types and characteristics (opaque wall, windows, doors) of cause of occurrence and existing state condensation defect is analyzed from evaluation of real application 100 case in 2015 ADDMC data.

A Methodology for Standard Establishment of Spatial Impact Zone according to Place Names of Road Sign in Urban Regions - Using the Road Sign Management System Database - (도시부 도로표지 안내지명에 따른 공간적 영향권 기준 설정방법에 관한 연구 - 도로표지관리시스템 데이터베이스를 활용하여 -)

  • Jung, In-Taek;Chong, Kyu-Soo
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.15 no.6
    • /
    • pp.1-9
    • /
    • 2016
  • Place names of road sign mean various place names being used on road signs for path guidance of drivers such as administrative district, facility, road, etc. It is very important that not only the choice method of place names for connectivity of road signs but standard establishment of spatial impact zone according to place names. However this standard are not established currently, so it is difficult to fix the spatial range for changing place names around the main facility according to the new construction or relocation of main facility in urban region. Considering the use of big data, one of the Government 3.0, we need to utilize actively the road sign management system database. This paper suggested a methodology for standard establishment of spatial impact zone according to place names of road sign in urban regions based on the road sign management system database. To perform a case study, we selected a major facility ("City Hall") which is the most frequently used the place name of road signs and presented standard of spatial impact zone by urban size in 84 cities.