Browse > Article
http://dx.doi.org/10.5515/KJKIEES.2014.25.5.548

Electromagnetic Wave Shielding Effectiveness Measurement Method of EMP Protection Facility  

Seo, Manjung (EMP Assessment Team, Korea Testing & Research Institute)
Chi, Seongwon (EMP Assessment Team, Korea Testing & Research Institute)
Kim, Youngjin (EMP Assessment Team, Korea Testing & Research Institute)
Park, Woochul (EMP Assessment Team, Korea Testing & Research Institute)
Kang, Hojae (Department of Electrical Engineering, Inha University)
Huh, Changsu (Department of Electrical Engineering, Inha University)
Publication Information
Abstract
EMP(Electromagnetic Pulse) protection facility was evaluated according to standard of shielding effectiveness. To comply with the standard, transmitting antenna was placed on outside of protection facility and receiving antenna was placed on inside of protection facility. However, measurement is impossible that place does not have enough space between protection facility and external concrete structure. In this paper, we performed a various of tests that put transmitting antenna inside the EMP protection facility in order to find out test method for measuring the shielding effectiveness of electromagnetic wave. Transmitting antenna was placed on inside of the EMP protection facility for measuring the shielding effectiveness to compare and analyze the impact of the position regarding to the transmitting and receiving antenna. As a result of test, in case that transmitting antenna was placed on inside of the EMP protection facility, it was found that test frequency range 10 kHz~1 GHz were occurred overall average difference of ${\pm}4$ dB level.
Keywords
ElectroMagnetic Pulse; MIL-STD-188-125-1; Shielding Effectiveness; EMP Protection Facility;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 최은하, "고출력 마이크로파의 발진장치 및 전자기 펄스탄 개발동향", 전력전자학회지, 9(1), pp. 20-25, 2004년 2월.   과학기술학회마을
2 MIL-STD-188-125-1, "High-altitude electromagnetic pulse(HEMP) protection for ground-based C41 facilities performing critical, time-urgent missions part 1 fixed facilities", Apr. 2005.
3 IEEE-STD-299, "IEEE standard method for measuring the effectiveness of electromagnetic shielding enclosures", Feb. 2007.
4 IEC-61000-4-23, "Electromagnetic compatibility (EMC) - Part 4-23: Testing and measurement techniques test methods for protective devices for HEMP and other radiated disturbances", Oct. 2000.
5 현세영, 이경원, 김민석, 육종관, "철근 콘크리트에 의한 전자기파 차폐효과 모델링", 한국전자파학회논문지, 23(3), pp. 384-391, 2012년 3월.
6 강희도, 오일영, 김정호, 육종관, "다층 지하 구조물로의 고고도 전자기파(HEMP) 커플링 현상에 대한 전자기적 모델링", 한국전자파학회논문지, 23(3), pp. 392-401, 2012년 3월.   과학기술학회마을   DOI   ScienceOn
7 IEC-61000-1-3, "Electromagnetic compatibility(EMC) - Part 1-3: General - The effects of high-altitude EMP (HEMP) on civil equipment and systems", Jun. 2002.