• Title/Summary/Keyword: facility safety management

Search Result 706, Processing Time 0.03 seconds

A study on the improvement plan of fire simulation training for the improvement of fire response ability : Focusing on the fire simulation training of business facility (화재대응능력 향상을 위한 화재모의훈련의 개선방안에 관한 연구 : 업무시설의 화재모의훈련 중심으로)

  • Kim, Bongjun;Ryu, Guhwan
    • Journal of Digital Convergence
    • /
    • v.18 no.9
    • /
    • pp.191-198
    • /
    • 2020
  • In this study, in order to propose an improvement plan for fire simulation training to improve fire response capability, fire simulation training is conducted for three business facilities, and changes according to whether training materials are used and whether the response time for each response stage is reflected in the training evaluation. The response posture and response ability of the training participants were observed and analyzed. As a result of the analysis, it was analyzed that most of the training participants improved their participation in training, response posture, and response ability when the use of training textbooks and response time for each response stage were reflected in the training evaluation. In the event of a fire simulation training, a number of training materials that can similarly implement the fire situation are used to improve and maintain the fire response capabilities (fire notification and fire report, initial extinguishing, and evacuation) of the training participants, and the target time for each response step. The result was that it can be used as a useful index for improving fire response capability and improving fire simulation training in the future and feedback only when quantitative training evaluation is conducted based on this setting.

Cost-Benefit Analysis Method for Ageing Equipment of Chemical Plants Using Risk Assessment (위험성평가를 이용한 노후설비에 대한 비용 편익분석 방법)

  • Jung, Soomin;Jung, Changmo;Kang, Seok-Min;Chae, Seungbeen;Kang, Seung-Gyun;Ko, Jae Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.4
    • /
    • pp.84-92
    • /
    • 2020
  • Most facilities in chemical plants operate in environments that are outside the range of temperature and pressure that can be encountered on a daily basis, and are vulnerable to aging due to these stresses and environmental conditions. The facilities exposed to these conditions are not only likely to fail due to cumulative damage, but also lead to accidents if maintenance and replacement are not performed.Recommendation guidelines called risk-based inspection are widely used around the world-wide. However, limits exist for facilities that have already elapsed for a certain. As a result of the survey on the aging of Ulsan industrial complex in Korea, which carries out proper inspection, many of the facilities have been used for 20 years. Also, most of the facilities where the accident occurred have been in operation for more than 20 years. Therefore, this study suggested criteria for classifying devices that have exceeded a certain period of use as obsolete facilities. In addition, quantitative risk assessment was conducted. The safety investment method using the cost-benefit analysis method was proposed in order to calculate the loss cost and reduce the risk by expressing the risks of the corresponding aged facility as an Economic index. By utilizing the method of cost-benefit analysis of old facilities using the quantitative risk assessment presented in this study, it can be expected to improve the performance and life of old facilities, improve production efficiency and reliability of the system of facilities, change the recognition of safety management costs, increase employee stability, and reduce loss costs.

Risk Assessment of Semiconductor PR Process based on Frequency Analysis of Flammable Material Leakage (반도체 PR 공정의 인화성 물질 누출 빈도분석을 통한 위험성 평가)

  • Park, Myeongnam;Chun, Kwang-Su;Yi, Jinseok;Shin, Dongil
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.5
    • /
    • pp.1-10
    • /
    • 2021
  • Semiconductor Photo Resist (PR) automation equipment uses a mixture of several flammable substances, and when it leaks during the process, it can lead to various accidents, therefore, risk assessment is necessary. This study analyzed the frequency of leakage of Acetone and PGMEA used in PR automation equipment and the frequency at which such leakage could lead to a fire accident through the frequency analysis method, and evaluated the need for additional risk reduction measures in the current facility. Based on the process leak data and ignition probability data of IOGP, leak frequency analysis and ignition probability were derived, and the frequency of actual fire accidents was analyzed by combining them. The frequency of material leakage in semiconductor PR process is 7.30E-03/year, and fire accidents can occur by acetone that exists above the flash point when the material is leaked, the frequency was calculated at the level of 1.24E-05/year. According to the UK HSE, for a major accident occurring with a frequency of 1.24E-05/year, it is defined as "Broadly Acceptable", a level that does not require additional measures for risk reduction when it causes 7 or less deaths, and due to the process operated by two people, no additional risk reduction are required.

Development of Maintenance Scenario Method for Small and Medium-sized Bridges Using Risk Matrix (리스크매트릭스를 활용한 중소규모 교량의 유지관리 시나리오 기법 개발)

  • Park, Hyun-Chan;Shin, Byoung-Gil;Cho, Choong-Yuen;Kim, Young-Min;Chang, Buhm-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.6
    • /
    • pp.161-168
    • /
    • 2021
  • This paper is a maintenance system for bridge represented by Class 3 and other than by law bridges. Domestic bridge are divided into Class 1 & 2 bridges and Class 3 & other than by law bridges. The number of type 3 and other than by law bridges is very large. But, it is considered to be of relatively low importance compared to Class 1 & 2 Bridge Bridge. So, in this paper is propose a maintenance system and procedure for small & medium-sized bridges. However, because the number of small & medium-sized bridges is large, it is not possible to evaluate the performance of all bridges like Class 1 & 2 bridge. The reason is the lack of manpower and budget. Based on the Risk Matrix method, a maintenance procedure was created to select the bridge for which performance evaluation should be performed first. For this purpose, basic information of the bridge is used. And, the developed maintenance procedures were applied to the bridges in actual use.

A Study on the Establishment and Application of Evaluation Criteria for Old Railway Station Considering the Level of Railway Service (철도 서비스수준을 고려한 노후철도역사 평가기준 마련 및 적용방안)

  • Kim, Kyung Ho;Kim, Si Gon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.44 no.1
    • /
    • pp.101-108
    • /
    • 2024
  • The total number of railroad stations managed in Korea is 322 (including general and wide-area railways), and a considerable number of stations are aging. In terms of the size of the existing railway station and the number of entrances, it has not been possible to secure adequate service capacity, and the demand for station improvement is increasing due to changes in surrounding conditions such as urban development. In the past, railroad stations were focused on the simple function of a connection passage in terms of maintenance or management, but in recent years, railroad stations are also changing to an atmosphere that they should be reborn as a user-centered comfortable, convenient, and safe service provision space. In this study, a case study related to the improvement of the old railway station was conducted to derive an improvement plan that meets the improvement standard of the old station, and the service level evaluation standard was developed. By introducing the concept of service level (LOS) in the development model, station congestion, station movement convenience, and station safety were selected as evaluation indicators. In addition, this development model applied an analytical stratification technique to divide various evaluation elements of each indicator into major and detailed elements and derive the relative importance of the elements by class. Priority for improvement was derived using the ratio of the number of E and F on the LOS for each facility. Based on this study, it is expected to be helpful in using it as an evaluation criterion for improving objective and equitable railway station.

Heavy concrete shielding properties for carbon therapy

  • Jin-Long Wang;Jiade J Lu;Da-Jun Ding;Wen-Hua Jiang;Ya-Dong Li;Rui Qiu;Hui Zhang;Xiao-Zhong Wang;Huo-Sheng Ruan;Yan-Bing Teng;Xiao-Guang Wu;Yun Zheng;Zi-Hao Zhao;Kai-Zhong Liao;Huan-Cheng Mai;Xiao-Dong Wang;Ke Peng;Wei Wang;Zhan Tang;Zhao-Yan Yu;Zhen Wu;Hong-Hu Song;Shuo-Yang Wei;Sen-Lin Mao;Jun Xu;Jing Tao;Min-Qiang Zhang;Xi-Qiang Xue;Ming Wang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.6
    • /
    • pp.2335-2347
    • /
    • 2023
  • As medical facilities are usually built at urban areas, special concrete aggregates and evaluation methods are needed to optimize the design of concrete walls by balancing density, thickness, material composition, cost, and other factors. Carbon treatment rooms require a high radiation shielding requirement, as the neutron yield from carbon therapy is much higher than the neutron yield of protons. In this case study, the maximum carbon energy is 430 MeV/u and the maximum current is 0.27 nA from a hybrid particle therapy system. Hospital or facility construction should consider this requirement to design a special heavy concrete. In this work, magnetite is adopted as the major aggregate. Density is determined mainly by the major aggregate content of magnetite, and a heavy concrete test block was constructed for structural tests. The compressive strength is 35.7 MPa. The density ranges from 3.65 g/cm3 to 4.14 g/cm3, and the iron mass content ranges from 53.78% to 60.38% from the 12 cored sample measurements. It was found that there is a linear relationship between density and iron content, and mixing impurities should be the major reason leading to the nonuniform element and density distribution. The effect of this nonuniformity on radiation shielding properties for a carbon treatment room is investigated by three groups of Monte Carlo simulations. Higher density dominates to reduce shielding thickness. However, a higher content of high-Z elements will weaken the shielding strength, especially at a lower dose rate threshold and vice versa. The weakened side effect of a high iron content on the shielding property is obvious at 2.5 µSv=h. Therefore, we should not blindly pursue high Z content in engineering. If the thickness is constrained to 2 m, then the density can be reduced to 3.3 g/cm3, which will save cost by reducing the magnetite composition with 50.44% iron content. If a higher density of 3.9 g/cm3 with 57.65% iron content is selected for construction, then the thickness of the wall can be reduced to 174.2 cm, which will save space for equipment installation.

A Study on the Improvement of Construction Cost Standards for Pipe Laying and Joining Work (관 부설 및 접합공사 공사비산정기준 개선에 관한 연구)

  • Oh, Jae-Hoon;Ahn, Bang-Ryul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.7
    • /
    • pp.675-684
    • /
    • 2020
  • To prevent safety accidents caused by aging pipe infrastructure and to maintain water quality, construction projects for water and sewage pipes are actively conducted across Korea. This study analyzed the criteria situations, site survey details, and regulation revisions related to the calculation of construction cost standards for pipe laying and joining work. The analysis showed that the major causes for revision are the unclear construction scope, limitations in implementing some pipe materials due to installation facility types, workforce focused on ordinary labor, limitations of manual laying work, and the lack of tool hire cost and machine expense-calculation criteria. Field studies were conducted to categorize the pipes according to their features, in addition to identifying the use of lifting heavy equipment and light equipment. In addition, excavation and testing work conducted in connection to pipe laying, as well as the use of skilled labor, were investigated. The current study clarified the work scope through new common items, provides an organization based on the pipe material, adjusted the workforce ratio to focus more on skilled labor, and developed grounds for calculating machine expenses. These revisions were estimated to save approximately 1.28% of the construction costs in each project according to an analysis of the construction cost impact study. truction costs in each project, according to an analysis of construction cost impact study.

Sampling and Cryogenic Pulverization and Storage of Environmental Samples and Improvement of Operating Procedures in National Environmental Specimen Bank (국가환경시료은행 시료 채취, 분쇄, 저장과 개선방안 고찰)

  • Lee, Jangho;Lee, Jongchun;Kim, Myungjin;Han, Areum;Lee, Eugene;Bade, Rabindra;Kim, Minsung
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.6
    • /
    • pp.823-839
    • /
    • 2012
  • Environmental Specimen Banks (ESBs) are playing pivotal role in monitoring the effect of environmental pollution on the ecosystem based on the retrospective analysis of the representative samples collected regularly and stored in cryogenic condition. In Korea, National Environmental Specimen Bank (NESB) was established in 2009 and the standard operating procedures (SOPs) for sampling, and cryogenic milling and storage had been prepared during 2007-2010. Since then, the tentative SOPs for the seven kinds of specimens (shoots of Red Pine (Pinus densiflora) and Korean Pine (Pinus koraiensis), leaves of Mongolian Oak (Quercus mongolica) and Zelkova Tree (Zelkova serrata), eggs of Feral Pigeon (Columba livia var. domestica), muscles and organs of Common Carp (Cyprinus carpio), and Freshwater Bivalve (Unio (Nodularia) douglasiae)) have been put to test in the field and laboratory as well against the practicality and feasibility. The SOPs were improved by reflecting the findings from the research and the following discussion regarding the selection of specimen (Feral Pigeon suffering from a control management), sample size (a problem of decreasing number of sampling trees related to increasing sampling time) and period (a problem related to a bud growth), and sampling methods etc.. In addition, barcoding system for the management of the specimen information, and monitoring system of the cryogenic storage to regulate the optimum temperature and the liquid nitrogen level were also developed for the efficient and effective control of the samples. Lastly, the safety guide and emergency protocol were augmented to guarantee a safe work environment with the cryogenic facility. These improvements of the SOPs are expected to contribute to more stable operation of the NESB.

Status of Nuclear Power Plant Decommissioning Cost Analysis in USA (미국의 원전해체 비용평가 기초자료 및 동향 분석)

  • Shin, Sanghwa;Kim, Soonyoung
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.2
    • /
    • pp.139-148
    • /
    • 2018
  • Assessment of NPP(Nuclear Power Plant) decommissioning cost is very important for safe decommissioning of nuclear power plants. In the United States, which has the most NPP decommissioning experience, the cost evaluation study has been conducted since the 1970s in order to decommissioning nuclear facilities. The US NRC has conducted studies on decommissioning technology, safety and cost for a variety of reactor type and nuclear installations. In the total decommissioning costs, the end of operation licenses accounted for the largest portion, followed by spent fuel management and site restoration. In case of immediate decommissioning, spent fuel management cost increased compared to delayed decommissioning, and delayed deocmmissioning increased the cost of terminating the operation license. However, in general, delayed decommissioning does not show any significant benefit as compared with immediate decommissioning. It is necessary to consider the evaluation according to the site conditions when evaluating the cost of decommissioning domestic nuclear power plants. Also, in Korea, IAEA recommendations were applied to reorganize the radioactive waste classification system. Therefore, it is necessary to develop a method to appropriately use the decommissioning data of the preceding US Nuclear Power Plant in the new classification system when estimating the amount of radioactive waste generated during decommissioning. In particular, the establishment of the evaluation methodology for the waste to be disposed of will be an important factor in securing the accuracy of the decommissioning cost. In addition, it is necessary to construct information data that can be applied to facility characteristics and work characteristics in order to evaluate the cost of demolition of domestic nuclear power plants.

A Study on Microbial Management Level of Manufacturing Environment, Raw Meat and Products in HACCP Implemented Meat Market (HACCP 인증 축산물 판매장의 제조 환경 및 식육의 미생물 관리수준에 관한 연구)

  • Cho, Seok-Hyun;Baek, Seung-Hee;Ahn, Jong-Ho;Nam, In-Sik
    • Korean Journal of Organic Agriculture
    • /
    • v.27 no.2
    • /
    • pp.193-204
    • /
    • 2019
  • The aim of this study was to investigate the effect of hazard analysis and critical control point (HACCP) system application on microbial hazard management levels of pork and manufacturing environments. In this study, we compared and analyzed microbial levels in raw meat, finished products, and manufacturing environments (knifes, gloves, and cutting boards) of HACCP and non-HACCP meat markets. In addition, we surveyed the hygiene statuses of HACCP and non-HACCP meat markets. The general bacterial counts in raw meat, finished products, and manufacturing environments were lower in HACCP meat markets than in non-HACCP meat markets. Particularly, non-HACCP meat markets exceeded the Ministry of Food and Drug Safety microbiological recommendation criteria for raw meats (8.7%) and finished products (8.7%). Escherichia coli and coliform counts in raw meat, finished products, and manufacturing environments were also lower in HACCP meat markets than in non-HACCP meat markets. The biological hazard levels of finished products from non-HACCP meat markets were affected by raw meat and manufacturing environment. Moreover, according to questionnaire survey results, personal hygiene, manufacturing environment, and facility standards were lower in non-HACCP meat markets than in HACCP meat markets. Implementation of HACCP at meat markets is expected to minimize food poisoning by reducing the biological hazard levels to provide safe livestock products to consumers.