• Title/Summary/Keyword: facility safety management

Search Result 706, Processing Time 0.026 seconds

A study on inspection methods for waste treatment facilities(II): Derivation of problems and improvement direction in inspection methods (폐기물처리시설의 세부검사방법 마련연구(II): 세부검사방법 문제점도출 및 개선방향 설정)

  • Pul-Eip Lee;Eunhye Kwon;Jun-Ik Son;Jun-Gu Kang;Taewan Jeon;Dong-Jin Lee
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.31 no.1
    • /
    • pp.85-100
    • /
    • 2023
  • In this study, in order to improve the installation periodical inspection method of waste treatment facilities, we conducted on-site surveys of waste treatment facilities classified into six fields, grasped the problems of inspection methods, and made improvements accordingly. And revised the inspection method for waste treatment facilities. As a result, in the field of incineration and incineration heat recovery, inspection methods such as total temperature measurement and one-year TMS data comparison using a thermal imaging camera were established. And for the safety of the inspected person, it was applied so that the waste can be replaced with a document without opening it. In the case of landfill facilities, the details regarding the use of video information processing equipment and the management of facilities covering the upper part of the landfill facility are presented in the law, but the items that do not have a inspection methods were applied to the inspection method. In the case of Food Waste Treatment Facility, inspection methods were put in place to ensure compliance with standards for foul-smelling fish in odor control, a major cause of complaints. As a result, 10 out of 18 improvement proposals were reflected in the incineration and sterilization grinding, cement kiln, and incineration heat recovery facilities, and 11 out of 12 improvement proposals were reflected in the landfill facility. In the case of food distribution waste treatment facilities, 10 out of 12 improvement proposals were reflected, and a total of 31 inspection methods were improved.

Definition and Division in Intelligent Service Facility for Integrating Management (지능화시설의 통합운영관리를 위한 정의 및 구분에 관한 연구)

  • PARK, Jeong-Woo;YIM, Du-Hyun;NAM, Kwang-Woo;KIM, Jin-Young
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.19 no.4
    • /
    • pp.52-62
    • /
    • 2016
  • Smart City is urban development for complex problem solving that provides convenience and safety for citizens, and it is a blueprint for future cities. In 2008, the Korean government defined the construction, management, and government support of U-Cities in the legislation, Act on the Construction, Etc. of Ubiquitous Cities (Ubiquitous City Act), which included definitions of terms used in the act. In addition, the Minister of Land, Infrastructure and Transport has established a "ubiquitous city master plan" considering this legislation. The concept of U-Cities is complex, due to the mix of informatization and urban planning. Because of this complexity, the foundation of relevant regulations is inadequate, which is impeding the establishment and implementation of practical plans. Smart City intelligent service facilities are not easy to define and classify, because technology is rapidly changing and includes various devices for gathering and expressing information. The purpose of this study is to complement the legal definition of the intelligent service facility, which is necessary for integrated management and operation. The related laws and regulations on U-City were analyzed using text-mining techniques to identify insufficient legal definitions of intelligent service facilities. Using data gathered from interviews with officials responsible for constructing U-Cities, this study identified problems generated by implementing intelligent service facilities at the field level. This strategy should contribute to improved efficiency management, the foundation for building integrated utilization between departments. Efficiencies include providing a clear concept for establishing five-year renewable plans for U-Cities.

SHIELDING ANALYSIS OF DUAL PURPOSE CASKS FOR SPENT NUCLEAR FUEL UNDER NORMAL STORAGE CONDITIONS

  • Ko, Jae-Hun;Park, Jea-Ho;Jung, In-Soo;Lee, Gang-Uk;Baeg, Chang-Yeal;Kim, Tae-Man
    • Nuclear Engineering and Technology
    • /
    • v.46 no.4
    • /
    • pp.547-556
    • /
    • 2014
  • Korea expects a shortage in storage capacity for spent fuels at reactor sites. Therefore, a need for more metal and/or concrete casks for storage systems is anticipated for either the reactor site or away from the reactor for interim storage. For the purpose of interim storage and transportation, a dual purpose metal cask that can load 21 spent fuel assemblies is being developed by Korea Radioactive Waste Management Corporation (KRMC) in Korea. At first the gamma and neutron flux for the design basis fuel were determined assuming in-core environment (the temperature, pressure, etc. of the moderator, boron, cladding, $UO_2$ pellets) in which the design basis fuel is loaded, as input data. The evaluation simulated burnup up to 45,000 MWD/MTU and decay during ten years of cooling using the SAS2H/OGIGEN-S module of the SCALE5.1 system. The results from the source term evaluation were used as input data for the final shielding evaluation utilizing the MCNP Code, which yielded the effective dose rate. The design of the cask is based on the safety requirements for normal storage conditions under 10 CFR Part 72. A radiation shielding analysis of the metal storage cask optimized for loading 21 design basis fuels was performed for two cases; one for a single cask and the other for a $2{\times}10$ cask array. For the single cask, dose rates at the external surface of the metal cask, 1m and 2m away from the cask surface, were evaluated. For the $2{\times}10$ cask array, dose rates at the center point of the array and at the center of the casks' height were evaluated. The results of the shielding analysis for the single cask show that dose rates were considerably higher at the lower side (from the bottom of the cask to the bottom of the neutron shielding) of the cask, at over 2mSv/hr at the external surface of the cask. However, this is not considered to be a significant issue since additional shielding will be installed at the storage facility. The shielding analysis results for the $2{\times}10$ cask array showed exponential decrease with distance off the sources. The controlled area boundary was calculated to be approximately 280m from the array, with a dose rate of 25mrem/yr. Actual dose rates within the controlled area boundary will be lower than 25mrem/yr, due to the decay of radioactivity of spent fuel in storage.

Survey on Educational Needs for Workers in Social Welfare Facilities in Jeju Special Self-Governing Province (제주특별자치도 사회복지시설종사자의 교육요구 조사)

  • Hwang, Seong-Joon
    • The Journal of the Korea Contents Association
    • /
    • v.20 no.1
    • /
    • pp.271-284
    • /
    • 2020
  • The purpose of this study is to identify the educational needs among social workers in social welfare facilities in Jeju province concerning lack of knowledge, skill and attitude, and establish the systematic education for prosecuting diverse training and suggest fundamental data for designing future curriculum. The results of analyzing top 10 educational needs for the workers are as follows: firstly technics for managing crises, understanding and practice for clients (characteristics, human right, safety and health), case management (basic), counseling technique (basic), case management (advanced), counseling technique (advanced), planning and operating social welfare program, managing client response and emotional labor, improving competence for communication (between staffs and clients, etc.), and finally assessing project outcome (project plan, execution, management and assessment, etc.). Social workers in social welfare facilities in the area have highly recognized the necessity of profession centred education. However, they had low satisfaction with the diversity of profession education in the Jeju island and the systematic training courses. This survey suggests the various results concerning qualitative growth of profession education, expansion of job-centred curriculum and security of professional instructors to fulfil systematic education training for social workers.

Review of In-situ Installation of Buffer and Backfill and Their Water Saturation Management for a Deep Geological Disposal System of Spent Nuclear Fuel (국외 사례를 통한 사용후핵연료 심층처분시스템 완충재 및 뒤채움재의 현장시공 및 포화도 관리 기술 분석)

  • Ju-Won Yun;Won-Jin Cho;Hyung-Mok Kim
    • Tunnel and Underground Space
    • /
    • v.34 no.2
    • /
    • pp.104-126
    • /
    • 2024
  • Buffer and backfill play an essential role in isolating high-level radioactive waste and retard the migration of leaked radionuclides in deep geological disposal system. A bentonite mixture, which exhibits a swelling property, is considered for buffer and backfill materials, and excessive groundwater inflow from surrounding rock mass may affect stability and efficiency of their role as an engineered barrier. Therefore, stringent quality control as well as in-situ installation management and inflow water constrol for buffer and backfill are required to ensure the safety of deep disposal facilities. In this study, we analyzed the design requirements of buffer and backfill by examining various laboratory tests and a field study of the Steel Tunnel Test at the Äspö Hard Rock Laboratory in Sweden. We introduced how to control the quality of buffer and backfill construction in-field, and also presented how to handle excessive groundwater inflow into disposal caverns, validating the groundwater retention capacity of bentonite pellets and the effectiveness of geotexile use.

A Study on the Nature-friendly Management Regarding the User Pattern of Yangjae Stream (양재천의 이용특성을 고려한 환경친화적 관리방안에 관한 연구)

  • Kim Sun-Hee;Hong Suk-Hwan;Bae Jung-Nam
    • Korean Journal of Environment and Ecology
    • /
    • v.18 no.3
    • /
    • pp.306-315
    • /
    • 2004
  • Yangjae stream, stretching through Seocho-gu and Gangnam-gu, is a representative city stream with its environmentally friendly stream makeover project model, launched in 1995. The district of Gangnam-gu, the subject of this study, is under high pressure from the residents for its use as a huge residential areas close to the stream. The study has two main purposes. The first is to identify the condition and characteristic of utilization of Yangjae stream which is currently being increased in use by the stream restoration. Secondly, the study aims to suggest the environment-friendly management to accomplish arrangement of the naturally friendly stream based on the identification survey, The result from the user survey with 303 valid answer sheets show that the people from neighboring residential areas use this stream a lot doing exercising(51.8%) and taking a walk(24.4%) in their free time. Also regular use rate is high, and people are likely to use it alone(30.4%) or as a family(28.4%). With regard to the need of facility increase, even though the respondents required resting places in the shade(80.8%) most, overall, additional introduction of facilities was analyzed as unnecessary(78.8%). safety issue(22.0%) and a lack of convenience facilities(17.6%) and resting places in the shade(16.6%) are pointed as main problems while the users are generally satisfied(59.5%) with the stream. Improving walk-way and planting trees for shade on the slope were designed as a solution for these problems. For securing safety through improvement of walk-way, the scattering of pressure of current walk with building new walk using berms was presented. In order to increase safety on the walk-way(see above figure), the study proposes to build a new walk-way with berms to disperse excessive pressure. It also suggests the tree planting to provide shade in the stream and to make a provision for the planting of forest trees in the current law.

Situations of GAP certified ginseng and 4P's strategies (GAP 인증인삼 현황과 4P 전략)

  • Hong, Seung-Jee;Kim, Kwan-Hoo
    • Korean Journal of Agricultural Science
    • /
    • v.38 no.2
    • /
    • pp.369-381
    • /
    • 2011
  • Ginseng in Korea has not only the big production value but also till a good reputation from overseas in the name of 'Korea Ginseng'. Having spread rapidly nationwide from 2000 year, its production keeps on increasing but its consumption becomes lazy and its price is also falling down because of comsumer's concern about mainly overusing pesticide for ginseng. In order to cope with this problem, the government introduced the GAP certification system to ginseng in 2006 to reflect consumer's needs for food safety. This system will be a good opportunity to promote ginseng consumption dramatically. In this aspect it is very important to know how well this system is established and how ginseng farmers build marketing strategies to draw new wind in the market. This study was carried out to look over the GAP certified ginseng system and show its marketing strategies using 4P's(product, place, promotion and price). The main results are as follows. GAP ginseng system currently has some weaknesses such as lack of systematic certification management and after-service, nonrealistic certification fee and poor linkage from production to consumption. In the marketing mix strategies, product strategy suggests that the most desirable appearance be transplanted ginseng filled with branch roots and 4 to 5 year-ginseng, and it is necessary to choose multi-brand strategy divided for present into for self-sufficiency and family brand strategy by use if its brand enlarges to processed products in the future. In the place strategy, 3 stages like 'producer group' - 'GAP certified facility' - 'sales shop' are based as the physical marketing channel according to traceability, and connected with giant retail market and environment friendly stand, and if its sales volume enlarges, it should be considered the GAP ginseng specialized marketplace which is a type of chain store. In the promotion strategy, the promotion of government level is necessary at first and producer alliances require the promotion targeting at the group of women under 40 with differentiation from price, quality, and safety. In the price strategy, the early stage-high price strategy which sets 20~25% higher for self-sufficiency and 30~35% for present is desirable.

Analysis and Improvement of HACCP Program for Small-and Medium-sized Dairy Plants of Korea (국내 중소규모 목장형 유가공장의 HACCP 적용 시 문제점 분석 및 개선방안 제안)

  • Kang, Il-Byeong;Song, Kwang-Young;Kim, Dong-Hyeon;Kim, Hong-Seok;Yim, Jin-Hyeok;Kim, Young-Ji;Lee, Joo-Yeon;Chon, Jung-Whan;Kim, Hyunsook;Om, Aeson;Koo, Rakhyun;Kim, Sae-Hun;Seo, Kun-Ho
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.1
    • /
    • pp.14-19
    • /
    • 2017
  • The purpose of the study was to simplify standard HACCP manual for improving the on-site applicability and increasing the implementation rate of HACCP program for small- and medium-sized dairy farms (SMDF). A survey was carried out in 32 SMDFs using a structured questionnaire. The results indicated that the number of workers had a positive correlation with HACCP certifications (p < 0.05). Most of HACCP non-certified farms (66.7%) were run by two workers with 40-60 cows and milking yields of 1,000-1,500 L per day. Major drawbacks for dairy farmers to implement current HACCP system were the difficulties in daily recording and facility management (40%). On the basis of the survey results, it was suggested that the development of on-site standard HACCP manual and user-friendly record chart with O/X checklist were the most urgent factors to increase HACCP implementation rate. In addition, the alternative third party service for microbial and chemical tests could also be accompanied for small-sized dairy farms.

A pilot study on SOC information system for SOC report card writing support (국내 SOC 리포트카드 작성 지원을 위한 SOC 정보시스템 시범 구축 연구)

  • Jang, Youn-Mi;Hong, Chang-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.2
    • /
    • pp.142-148
    • /
    • 2017
  • Along with economic growth in the 1970s, the nation's economy, railroads, and airports have soared, but the facilities have been aging for 30 years. The aging SOC lowers the national competitiveness and threatens the safety of the people. SOC is a key asset of the national life and economic activity, and is a key factor for evaluating the national competitiveness. Therefore, it is necessary to systematically manage and operate the SOC related to people's lives. In the USA, the SOC report card is issued regularly. Those reports are used as a basis for securing budgets. In Korea, facilities management institutions are different. Therefore, there is no integrated SOC monitoring system. Hence, this study developed a 'SOC information system' that can collect reports scattered throughout the country and support report cards. The demonstration system was implemented through the web and the feasibility of implementing the evaluation support system was confirmed. The collection distributed SOC data should be supported by national policy. Although it takes a long time, it is necessary to improve national competitiveness and public safety.

Characteristics of Water Quality In the Shihwa Lake and Outer Sea (시화호 및 주변해역의 수질 특성)

  • Jang, Jeong-Ik;Han, Ihn-Sub;Kim, Kyung-Tae;Ra, Kong-Tae
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.17 no.2
    • /
    • pp.105-121
    • /
    • 2011
  • The operation of tidal power facility may induce severe changes of water quality in Shihwa Lake. Current water quality data are quite important to water quality management policy of Shihwa Lake. Thus, the water quality data of Shihwa Lake and its adjacent sea in 2010 were presented to characterize the temporal and spatial changes of water parameters such as pH, SS, DO, COD, dissolved nutrients, chlorophyll-a, TN and TP. Highest levels of water quality parameters were observed near the Shihwa and Banweol industrial complexes and the levels of water quality parameters were on a decreasing trend to those near the water gate. It suggests that the horizontal distributions of water quality levels are mainly controlled by the supply of fresh water from streams and the inflow of outer seawater by operation of water gate. Although the higher concentrations of TN and TP were observed in the location being affected by Sorae port, the levels of water quality parameters in outer sea of Shihwa Lake were lower than those in Lake. In summer season, hypoxic condition was well developed in bottom water by strong stratification and active decomposition of organic matter. Thus, the vertical distributions of dissolved nutrient, TN and TP concentrations showed the concentrations to be higher in bottom seawater than those in surface seawater whereas the vertical distributions of chlorophyll-a, COD and POC concentrations showed the concentrations to be higher in surface seawater than those in bottom water. Results of Pearson's correlation matrix for surface seawater demonstrated that salinity showed negatively good correlation with not only dissolved nutrients except for ammonium but chlorophyll-a, COD and POC This result indicates that the supply of dissolved nutrients through several streams might significantly affect phytoplankton bloom and increase of COD concentration in surface seawater.