An Analysis on the Appropriation of Chemical Accident Evacuation Facility Using GIS - focused on Ulsan metropolitan city - (GIS 기법을 활용한 화학사고 대피시설의 적정성 분석 - 울산광역시를 대상으로 -)

  • SONG, Bong-Geun;LEE, Tae-Wook;KIM, Hyun-Ju;KIM, Tai-Hoon
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.21 no.1
    • /
    • pp.71-82
    • /
    • 2018
  • The purpose of this study is to minimize damage of chemical accidents through the appropriation analysis of evacuation facility position focused on Ulsan metropolitan city. For analysis, informations such as pollutant release and transfer registers(PRTR), population census, and evacuation facilities were used. After then, damage assessment of chemical accidents, accessibility and appropriation of evacuation facilities were analyzed. Damage of chemical accidents is high in around 5km of industrial complex there is dense of chemical facility and population. Evacuation facilities were mainly situated in hazard area of chemical accidents, but accessibility of evacuation facilities was vulnerable in chemical plant neighborhood. Therefore, safety check of deteriorated plants is important for prevention of chemical accidents. Also, effective evacuation plan considering capacity and scale of evacuation facilities will be established.

Detection and Diagnosis of Power Distribution Supply Facilities Using Thermal Images (열화상 이미지를 이용한 배전 설비 검출 및 진단)

  • Kim, Joo-Sik;Choi, Kyu-Nam;Lee, Hyung-Geun;Kang, Sung-Woo
    • Journal of the Korea Safety Management & Science
    • /
    • v.22 no.1
    • /
    • pp.1-8
    • /
    • 2020
  • Maintenance of power distribution facilities is a significant subject in the power supplies. Fault caused by deterioration in power distribution facilities may damage the entire power distribution system. However, current methods of diagnosing power distribution facilities have been manually diagnosed by the human inspector, resulting in continuous pole accidents. In order to improve the existing diagnostic methods, a thermal image analysis model is proposed in this work. Using a thermal image technique in diagnosis field is emerging in the various engineering field due to its non-contact, safe, and highly reliable energy detection technology. Deep learning object detection algorithms are trained with thermal images of a power distribution facility in order to automatically analyze its irregular energy status, hereby efficiently preventing fault of the system. The detected object is diagnosed through a thermal intensity area analysis. The proposed model in this work resulted 82% of accuracy of detecting an actual distribution system by analyzing more than 16,000 images of its thermal images.

A Study on the Effective Method of Fire Extinguisher Maintenance In the Underground Parking Lot of the Apartment (아파트 지하주차장 소화기의 유지관리 효율화 방안에 관한 연구)

  • Lee, Young-Sam
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.3
    • /
    • pp.1-8
    • /
    • 2016
  • The definition of an apartment is a building more than 5 stories high and which is the standard law. Currently, the number of apartments is increasing much faster than detached houses. Owning an apartment is a normal trend these days. However, the increasing number of apartments has been increasing the number of apartment fires which also has been making social problems. Therefore, this study was conducted for the fire extinguisher among other fire facilities because it is important for initial fire suppression. The research subject is on the fire extinguisher that is in the underground parking lot of 40 apartment complexes which are more than 10 stories. Survey and analysis were conducted for 80 fire extinguishers. There are two fire extinguishers for each apartment. The result of this study is that all installed fire extinguishers are ABC dry chemical type, 92% of them is 3.3kg and that meet the legal height(less than 1.5m). However, the condition such as appearance, inspection, manufactured year, appearance of signs, material of signs, size of signs, etc. was insufficiency. So improvement of law and system that are fire facility construction, maintenance implementation and additional designation of type approval about sign will be needed in my opinion.

A Study on Level of Economical Contribution due to Ship Type in Incheon Port (인천항 입.출항 선박형태에 따른 기여도 분석에 관한 연구)

  • Nam, Heung-Woo;Nam, Young-Woo;Jho, Yong-Chul;Lee, Chang-Ho
    • Journal of the Korea Safety Management & Science
    • /
    • v.13 no.2
    • /
    • pp.203-210
    • /
    • 2011
  • Incheon Port has been served as not only the center of the Yellow Sea and port for trade with China but also domestic gateway port for the metropolitan area, playing a professional role as the greatest domestic Port which processes a variety of items such as imported raw materials, bulk cargo, oil and gas and so on. This study was conducted based on step by step business process between port entry and departure of ship, and incurred cost according to port industry classification and performance on the port facility. Bulk cargo and general cargo such as grain, food, steel, scrap metal, wood, coal, LNG, LPG and oil etc., which have a vast majority of import goods, have been treated by 57,062 thousand tons and 7,409 thousand tons of container cargo were processed at Incheon Port in 2009. Bulk vessels and carriers moving items such as LPG, LNG and oil recorded 38,836 thousand won and full-container vessels recorded 11,001 thousand won as the amount of notified port facility usage fees in 2008.

A Study on Requirements for Facilities' Changes with the changes in Legislations and Education Curriculum of Infants (영유아 관련 법령 및 교육과정 변천 비교에 따른 시설 변화 요구사항 연구)

  • Jung, Eu-Gene;Oh, Byeong-Uk;Jung, Jin-Ju
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.21 no.1
    • /
    • pp.3-11
    • /
    • 2014
  • The policies is always changes according to the changing times, and changes take place in educational facilities welfare policy. Early childhood facilities, is no exception. Recent, increase in the number of kindergarten and kindergarten children according to policy changes of government's active welfare. This change in pattern, policy changes and increased support to know the impact on the community, and this is not just a simply agenda that they need to be recognized social change. In addition, it can be seen changes in relevant laws and educational process according to childhood policy change flow and depending on social change. In this study, comparative study infants and installation of the facility based on criteria, ensuring standards of early childhood facility site, facilities of evolution of infants care act, act infants, infants of activities safety management. And Standards and facilities that are required to change the direction of the revision is for the purpose of research through changes in kindergarten curriculum to respond the policies flow. Research methods are literature on the various laws and research analysts, leading comparison of different child care and child care policy changes in laws and regulations to review materials are analyzed.

A Study on the Improvement Method of the Fire Department Connection for Fire Fighting at the Shopping Center Building (상가건물 소방용 연결송수관설비 송수구의 개선방안에 관한 연구)

  • Lee, Young-Sam
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.4
    • /
    • pp.11-17
    • /
    • 2016
  • Currently, the number of a shopping center building is increasing because most people want to go a shopping center building easily for buying many things and eating some foods. That are a normal trend these days. However, the increasing number of shopping center buildings has been increasing the number of shopping center building fires which also have been making social problems. Therefore, this study was conducted for the fire department connection among other fire facilities because it is important for fire suppression. The research subject is on the fire department connections that are on 70 shopping center buildings of more than 5 years old constructed. Survey and analysis were conducted for 70 fire department connections. The result of this study is that all installed fire department connections have a type that includes one or two holes each at 65mm wide, and the average distance between fire department connections and access roads is 4.85m. The total average percentage of insufficiency conditions such as drive ways for fire trucks, visibility, accessibility, pressure range sign, installed height, cover of the hole, etc. is 45.3%. So improvement of law and systems, that are fire facility construction and maintenance implementations, will be needed in my opinion.

Current Issues and their Solutions in the Leisure Sports Tourism Industry

  • Dong-Ho SEONG
    • The Journal of Industrial Distribution & Business
    • /
    • v.15 no.6
    • /
    • pp.9-15
    • /
    • 2024
  • Purpose: The primary aim of this study is to investigate the current issues in the leisure sports tourism and propose viable solutions based on a comprehensive review of existing literature. The specific objectives are to: (1) Identify the key challenges facing the leisure sports tourism industry. (2) Analyze the impact of these challenges on the industry's growth and sustainability. (3) Review and synthesize existing research to propose evidence-based solutions. Research design, data and methodology: The preliminary search yielded an extensive list of articles. These articles underwent a rigorous screening process based on their titles and abstracts. The inclusion criteria were: (1) studies focused specifically on the leisure sports tourism industry, (2) empirical research providing data on the identified issues, and (3) peer-reviewed journal articles. Results: The leisure sports tourism industry faces several pressing issues requiring effective solutions to ensure sustainability and growth. This section provides four critical solutions addressing the identified challenges: environmental sustainability, infrastructure and facility management, seasonality and economic impact, and health and safety concerns. Conclusions: The findings highlight several actionable solutions to the current issues faced by the leisure sports tourism industry. This industry can achieve a more stable and sustainable growth trajectory by addressing environmental sustainability, infrastructure and facility management, seasonality, and health and safety concerns.

A Study on the Safety Management Standards and Safety Indicators Private Lodging in Farming and Fishing Villages in Rural Area (농어촌민박의 안전관리 기준 및 안전지표에 관한 연구)

  • Suh, hey-sung;Lee, Yong-soo;Kim, Youna-ah
    • Journal of the Korea Institute of Construction Safety
    • /
    • v.3 no.1
    • /
    • pp.1-8
    • /
    • 2020
  • Various support is provided for the increase in the number of private lodging users in farming and fishing villages and related government policies. However, the bed-and-breakfast accommodation in rural areas lack safety standards or safety indicators for the service pension Gangneung, carbon monoxide leak accident in December 2018, 2020 East Sea in January, Pension. Large gas explosion, accident and is threatening the security of their citizens. Unlike lodging facilities, private lodging in farming and fishing villages is allowed to operate with certain requirements such as fire extinguishers and fire alarms. The purpose of this study is to present safety standards and safety indicators for lodging facilities in farming and fishing villages, which are necessary for the operation management and inspection of local governments and the government related to lodging in farming and fishing villages. Through the study, safety management areas of private lodging in farming and fishing villages were divided into facility safety, fire safety, food safety and living safety, and detailed inspection indicators were presented. There is an academic implication that research on safety management of lodging facilities has been expanded through safety research in areas related to private lodging in farming and fishing villages. It has practical implications in that it provides management standards and indicators that can be used for safety management of private lodging in farming and fishing villages. The limitations of this study are that more studies on private lodging in farming and fishing villages are expected to be conducted through the results of this study, and the lack of research on accommodation safety has prevented more detailed indicators from being derived.

A Study on Evaluation Plan of Fire Safety Performance for Public Building (공동주택의 화재안전성능 평가방안에 관한 연구)

  • Ku, Jae-Hyun
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.4
    • /
    • pp.25-32
    • /
    • 2019
  • From the viewpoint of fire-fighting activities, public building have structural and management problems in fire, so evacuation disturbance and risk of expanding combustion are high. As a result of analyzing various fire fragile factors of public building, The evaluation areas were derived from safety systems, fire-fighting facility, structure safety, general safety and the evaluation factors were presented. Also, the characteristics of domestic and foreign certification systems were analyzed by comparing and analyzing the status of fire safety performance certification system for 6 domestic and overseas apartment houses. In conclusion, the 5 convergence directions of certification system and 22 evaluation items by 4 evaluation fields were derived, and based on this, we have established 3 convergence introduction plans of fire safety performance certification system of public building.

Hazardous Material Process Risk Evaluation Using HAZOP and Bow-tie (HAZOP 및 BOW-TIE를 이용한 위험물질 취급공정의 위험성평가)

  • Min-Seo Nam;Byung-Tae Yoo
    • Journal of the Korean Institute of Gas
    • /
    • v.28 no.1
    • /
    • pp.35-43
    • /
    • 2024
  • With continuous advancements in industry, science, and technology, there is a steady increase in the number and utilization of new chemicals. The growing societal emphasis on chemical safety management is paralleled by an increasing public demand for robust safety measures. While various ministries at the government level oversee the safety management of chemical substances, the occurrence of accidents related to chemical substances remains frequent each year due to problems such as aging facilities and careless handling. Upon analyzing domestic chemical accident cases, incidents occurred predominantly in the sequence of leakage, explosion, fire, and others. The main causes of these accidents were examined, revealing facility defects and non-compliance with safety management as the primary contributing factors. In this study, Hazard and Operability Analysis (HAZOP) was employed to identify hazardous risk factors associated with the handling of hydrofluoric acid in workplaces, and a risk assessment was performed using Bow-Tie method. Based on the results of this study, it is expected to enhance safety management plans aimed at preventing chemical accidents in workplaces dealing with similar facilities. Ultimately, these insights contribute to the development of an advanced chemical safety management system, capable of proactively preventing potential chemical accidents.