• Title/Summary/Keyword: f0 peak time

Search Result 113, Processing Time 0.032 seconds

Voice quality distinctions of the three-way stop contrast under prosodic strengthening in Korean

  • Jiyoung Jang;Sahyang Kim;Taehong Cho
    • Phonetics and Speech Sciences
    • /
    • v.16 no.1
    • /
    • pp.17-24
    • /
    • 2024
  • The Korean three-way stop contrast (lenis, aspirated, fortis) is currently undergoing a sound change, such that the primary cue distinguishing lenis and aspirated stops is shifting from voice onset time (VOT) to F0. Despite recent discussions of this shift, research on voice quality, traditionally considered an additional cue signaling the contrast, remains sparse. This study investigated the extent to which the associated voice quality [as reflected in the acoustic measurements of H1*-H2*, H1*- A1*, and cepstral peak prominence (CPP)] contributes to the three-way stop contrast, and how the realization is conditioned by prominence- vs. boundary-induced prosodic strengthening amid the ongoing sound change. Results for 12 native Korean speakers indicate that there was a substantial distinction in voice quality among the three stop categories with the breathiness of the vowel being the greatest after the lenis, intermediate after the aspirated, and least after the fortis stops, indicating the role of voice quality in the maintenance of the three-way stop contrast. Furthermore, prosodic strengthening has different effects on the contrast and contributes to the enhancement of the phonological contrast contingent on whether it is induced by prominence or boundary.

Seasonal Prevalence and Altitudinal Distribution of the Flies in Mt. Hallasan, Jejudo Island, Korea (제주도 한라산 일대 파리류의 계절적인 발생소장 및 수직분포)

  • Jo, Tae-Ho
    • Journal of Environmental Science International
    • /
    • v.19 no.4
    • /
    • pp.491-507
    • /
    • 2010
  • This study focuses on the fauna, seasonal prevalence and altitudinal distribution of the flies from March to November, 2008 in Mt. Hallasan, Jejudo Island, Korea. The fauna of flies was 39 species belonging to 5 Families which consist of 12 Calliphoridae, 19 Muscidae, 5 Sarcophagidae, 1 Dryomyzidae 1, Scathophagidae and 1 Anthomyiidae. The total number of flies collected was 21,605 with sex ratio of 57.98% in Mt. Halla. The ratio is higher than that of the residential area and other mountain survey sites. The average number of per trap individuals collected on the trapping day is 267, which is similar with the average of Mts. Jiryong, Juwang, Palgong and Gumo. The five dominant species showed a distinctive seasonal prevalence of 92.6% of the total flies: Chrysomyia pinguis (34.2%), Calliphora lata (25.3%), Hydrotaea dentipes(23.1%), Fannia scalaris (5.1%), and Lucilia caesar (4.9%). The seasonal prevalence of the flies was from the beginning of March to the end of November, and the highest peak time of the whole flies, males and females were different respectively. In the similarity index of the flies collected in different altitude, that of between 1,000 meters and 1,500 meters was the highest among the indices of 500 meters and above 1,000 meters. The index at each altitude was above 80% because of the same area. The diversity index of fly species was between 0.00 and 0.88 through altitudinal traps monthly. The highest index in Trap 1 was 0.88 in October, in Trap 2, 0.82 in July and in Trap 3, 0.63 in July. The diversity above 1,000 meters was most various in July. The five dominant species of C. pinguis, C. lata, H dentipes, F. scalaris, and L. caesar showed distinctive seasonal prevalence, relative abundance and altitudinal distribution respectively.

Pest Control Effect using Unmanned Automatic Pesticide Spraying Device in Vegetable Greenhouse (시설채소 온실에서 무인 자동 약제 살포장치를 이용한 해충 방제효과)

  • Lee, Jung Sup;Lee, Jae Han;Bang, Ji Wong;Kim, Jin Hyun;Jang, Hye Sook
    • Journal of Bio-Environment Control
    • /
    • v.31 no.1
    • /
    • pp.52-59
    • /
    • 2022
  • Pest control treatment was carried out using an unmanned automatic pesticide spraying system that can spray pesticides on crops while moving autonomously to control pests in vegetable greenhouse. As a result of examining the control effect on tomato and strawberry on thrips (Frankliniella occidentalis) and greenhouse whitefly (Trialeurodes vaporariorum) pests, 85.6% of yellow flower thrips were found in tomatoes and 87.5% in strawberries, and 81.7% (tomato) and 80.6% (strawberry) of greenhouse whitefly. In addition, the control effect according to the pesticide treatment method showed a control effect of 81.7% of the chemical spraying treatment by manpower and 83.9% of the automatic moving pesticide spraying treatment (F=22.1, p < 0.001). When comparing the control effect between the two treatment sections, there was no significance, but the automatic transfer spraying treatment showed a 2.2% higher effect. On the other hand, as a result of comparing the spraying time of the drug, the automatic unmanned control sprayer had a spraying time of 5 min/10a, which took about 25 min less than the conventional manpower spraying time of 25-30 min/10a. Based on these results, it was judged that the automatic transfer spraying method could be usefully used for efficient pest control in the facility greenhouse during the peak period of development.

Spatial Extension of Runoff Data in the Applications of a Lumped Concept Model (집중형 수문모형을 활용한 홍수유출자료 공간적 확장성 분석)

  • Kim, Nam Won;Jung, Yong;Lee, Jeong Eun
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.9
    • /
    • pp.921-932
    • /
    • 2013
  • Runoff data availability is a substantial factor for precise flood control such as flood frequency or flood forecasting. However, runoff depths and/or peak discharges for small watersheds are rarely measured which are necessary components for hydrological analysis. To compensate for this discrepancy, a lumped concept such as a Storage Function Method (SFM) was applied for the partitioned Choongju Dam Watershed in Korea. This area was divided into 22 small watersheds for measuring the capability of spatial extension of runoff data. The chosen total number of flood events for searching parameters of SFM was 21 from 1991 to 2009. The parameters for 22 small watersheds consist of physical property based (storage coefficient: k, storage exponent: p, lag time: $T_l$) and flood event based parameters (primary runoff ratio: $f_1$, saturated rainfall: $R_{sa}$). Saturated rainfall and base flow from event based parameters were explored with respect to inflow at Choongju Dam while other parameters for each small watershed were fixed. When inflow of Choongju Dam was optimized, Youngchoon and Panwoon stations obtained average of Nash-Sutcliffe Efficiency (NSE) were 0.67 and 0.52, respectively, which are in the satisfaction condition (NSE > 0.5) for model evaluation. This result is showing the possibility of spatial data extension using a lumped concept model.

Effect of Pressure Rise Time on Tidal Volume and Gas Exchange During Pressure Control Ventilation (압력조절환기법에서 압력상승시간(Pressure Rise Time)이 흡기 일환기량 및 가스교환에 미치는 영향)

  • Jeoung, Byung-O;Koh, Youn-Suck;Shim, Tae-Sun;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong;Lim, Chae-Man
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.5
    • /
    • pp.766-772
    • /
    • 2000
  • Background : Pressure rise time (PRT) is the time in which the ventilator aclieves the set airway pressure in pressure-targeted modes, such as pressure control ventilation (PCV). With varying PRT, in principle, the peak inspiratory flow rate of the ventilator also varies. And if PRT is set to a shorter duration, the effective duration of target pressure level would be prolonged, which in turn would increase inspiratory tidal volume(Vti) and mean airway pressure (Pmean). We also postulated that the increase in Vti with shortening of PRT may relate inversely to the patients' basal airway resistance. Methods : In 13 paralyzed patients on PCV (pressure control 18$\pm$9.5 cm $H_2O$ $FIO_2\;0.6\pm0.3$, PEEP 5$\pm$3 cm $H_2O$, f 20/min, I : E1 : 2) with Servo 300 (Siemens-Elema, Solna, Sweden) from various causes of respiratory failure, PRT of 10 %, 5 % and 0 % were randomly applied. At 30 min of each PRT trial, peak inspiratory flow (PIF, L/sec), Vti (ml), Pmean (cm $H_2O$) and ABGA were determined. Results : At PRT 10%, 5%, and 0%, PIF were 0.69$\pm$0.13, 0.77$\pm$0.19, 0.83$\pm$0.22, respectively (p<0.001). Vti were 425$\pm$94, 439$\pm$101, 456$\pm$106, respectively (p<0.001), and Pmean were 11.2$\pm$3.7, 12.0$\pm$3.7, 12.5$\pm$3.8, respectively (p<0.001). pH were 7.40$\pm$0.08, 7.40$\pm$0.92, 7.41$\pm$0.96, respectively (p=0.00) ; $PaCO_2$ (mm Hg) were 47.4$\pm$15.8, 47.2 $\pm$15.7, 44.6$\pm$16.2, respectively (p=0.004) ; $PAO_2-PaO_2$ (mm Hg) were 220$\pm$98, 224$\pm$95, 227$\pm$94, respectively (p=0.004) ; and $V_n/V_T$ as determined by ($PaCO_2-P_E-CO_2$)/$PaCO_2$ were 0.67$\pm$0.07, 0.67$\pm$0.08, 0.66$\pm$0.08, respectively (p=0.007). The correlation between airway resistance and change of Vti from PRT 10% to 0% were r= -0.243 (p=0.498). Conclusion : Shortening of pressure rise timee during PCV was associated with increased tidal volume, increased mean airway pressure and lower $PaCO_2$.

  • PDF

Simultaneous determinations of anthracycline antibiotics by high performance liquid chromatography coupled with radial-flow electrochemical cell (고성능 액체 크로마토그래피/방사흐름 전기화학전지를 이용한 안트라사이클린계 항생제의 동시 정량)

  • Cho, Yonghee;Hahn, Younghee
    • Analytical Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.308-314
    • /
    • 2007
  • The analytical method of HPLC with the radial-flow electrochemical cell (RFEC) has been developed to determine doxorubicin, epirubicin, nogalamycin, daunorubicin and idarubicin simultaneously by employing a reversed-phase chromatography. Anthracyclines were detected at -0.74 V vs. a Ag/AgCl (0.01 M NaCl) reference electrode, a potential of diffusion current plateau in the mobile phase. At a $V_f$ of 1.0 mL/min doxorubicin, epirubicin, daunorubicin and idarubicin appeared at a retention time ($t_r$) of 6.4 min, 7.4 min, 12.7 min and 18.4 min, respectively, while at a $V_f$ of 0.6 mL/min, doxorubicin, epirubicin, nogalamycin, daunorubicin and idarubicin appeared at a $t_r$ of 9.9 min, 11.5 min, 13.5 min, 19.6 min and 28.7 min, respectively. The linearity between each anthracycline injected ($2.40{\times}10^{-7}M{\sim}1.42{\times}10^{-5}M$) and peak area (charge) was excellent with the square of the correlation coefficient ($R^2$) higher than 0.999. The detection limits were $1.0{\times}10^{-8}M{\sim}1.5{\times}10^{-7}M$ for the five anthracyclines. Within-day precision for the five anthracyclines were in reasonable relative standard deviations less than 3 % ($1.00{\times}10^{-6}M{\sim}1.42{\times}10^{-5}M$) except the lower concentrations less than $0.7{\mu}M$. Solid phase extractions of $1.00{\times}10^{-5}M$ epirubicin, $0.48{\times}10^{-5}M$ nogalamycin and $1.52{\times}10^{-5}M$ daunorubicin from human serum with a $C_{18}$ cartridge resulted in 97 %, 100 % and 90 % of recoveries, respectively.

Electrochemical Performances of Acid-Treated and Pyrolyzed Cokes According to Acid Treatment Time (산처리 시간별 산화 코크스와 열분해 코크스의 전기화학적 거동)

  • Kim, Ick-Jun;Yang, Sunhye;Jeon, Min-Je;Moon, Seong-In;Kim, Hyun-Soo
    • Applied Chemistry for Engineering
    • /
    • v.19 no.4
    • /
    • pp.407-412
    • /
    • 2008
  • As an activation procedure, in this study, the oxidation treatment of needle cokes with a dilute nitric acid and sodium chlorate $(NaClO_3)$, combined with heat treatment, was attempted. The structures of acid-treated and pyrolyzed coke were examined with XRD, FESEM, elemental analyzer, BET, and Raman spectroscopy. The behavior of double layer capacitance was investigated with the analysis of charge and discharge. The structure of needle coke treated with acid was revealed to a single phase of (001) diffraction peak after 24 h. On the other hand, thecoke oxidized by heat treatment was reduced to a graphite structure of (002) at $300^{\circ}C$. The distorted graphene layer structure, derived from the process of oxidation and reduction of the inter-layer, makes the pores by the electric field activation at the first charge, and generates the double layer capacitance from the second charge. The cell using pyrolyzed coke with 24 h acid treatment and $300^{\circ}C$ heat treatment exhibited the maximum capacitance per weight and volume of 33 F/g and 30 F/mL at the two-electrode system in the potential range of 0~2.5 V.

Preliminary Research of CZT Based PET System Development in KAERI

  • Jo, Woo Jin;Jeong, Manhee;Kim, Han Soo;Kim, Sang Yeol;Ha, Jang Ho
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.2
    • /
    • pp.81-86
    • /
    • 2016
  • Background: For positron emission tomography (PET) application, cadmium zinc telluride (CZT) has been investigated by several institutes to replace detectors from a conventional system using photomultipliers or Silicon-photomultipliers (SiPMs). The spatial and energy resolution in using CZT can be superior to current scintillator-based state-of-the-art PET detectors. CZT has been under development for several years at the Korea Atomic Energy Research Institute (KAERI) to provide a high performance gamma ray detection, which needs a single crystallinity, a good uniformity, a high stopping power, and a wide band gap. Materials and Methods: Before applying our own grown CZT detectors in the prototype PET system, we investigated preliminary research with a developed discrete type data acquisition (DAQ) system for coincident events at 128 anode pixels and two common cathodes of two CZT detectors from Redlen. Each detector has a $19.4{\times}19.4{\times}6mm^3$ volume size with a 2.2 mm anode pixel pitch. Discrete amplifiers consist of a preamplifier with a gain of $8mV{\cdot}fC^{-1}$ and noise of 55 equivalent noise charge (ENC), a $CR-RC^4$ shaping amplifier with a $5{\mu}s$ peak time, and an analog-to-digital converter (ADC) driver. The DAQ system has 65 mega-sample per second flash ADC, a self and external trigger, and a USB 3.0 interface. Results and Discussion: Characteristics such as the current-to-voltage curve, energy resolution, and electron mobility life-time products for CZT detectors are investigated. In addition, preliminary results of gamma ray imaging using 511 keV of a $^{22}Na$ gamma ray source were obtained. Conclusion: In this study, the DAQ system with a CZT radiation sensor was successfully developed and a PET image was acquired by two sets of the developed DAQ system.

Effects of Supplementation of Synbiotic Co-cultures Manufactured with Anaerobic Microbes on In Vitro Fermentation Characteristics and In Situ Degradability of Fermented TMR (혐기성 미생물로 제조한 synbiotics 혼합배양물의 첨가가 발효 TMR의 발효특성과 소실률에 미치는 영향)

  • Lee, Shin-Ja;Shin, Nyeon-Hak;Hyun, Jong-Hwan;Kang, Tae-Won;An, Jung-Jun;Jung, Ho-Sik;Moon, Yea-Hwang;Lee, Sung-Sill
    • Journal of Life Science
    • /
    • v.19 no.11
    • /
    • pp.1538-1546
    • /
    • 2009
  • This study was conducted to estimate the in vitro fermentation characteristics and in situ degradabilities of total mixed rations fermented by the synbiotic co-cultures composed of various anaerobic microorganisms in the rumen of cow. Seventy two TMR bags (4 treatments $\times$ 6 fermentation days $\times$ 3 replications) were manufactured for in vitro and in situ experiments. The experiment was composed of four treatments including the control, the mould and bacteria synbiotics (T1), the mould and yeast synbiotics (T2) and the bacteria and yeast synbiotics (T3). Each treatment had six fermentation days (1, 3, 5, 7, 14, 21 day) with three replications. Two rumen cannulated Holstein cows (550 ㎏ of mean body wt) were used for in situ trial, and a total of 96 nylon bags were retrieved from the rumen according to eight fermentation times (1, 3, 6, 9, 18, 24, 48 and 72 hr). The mean fermentation temperatures of TMRs by supplementation of anaerobic micoorganism co-cultures ranged from $22.97^{\circ}C$ to $26.07^{\circ}C$, and tended to increase steadily during the entire period. pH values of the F-TMRs ranged from 4.39 to 4.98 and tended to decrease with the extension of the fermentation period, and decreased by supplementation of synbiotics (p<0.05). The ammonia concentrations of F-TMRs were not affected by addition of synbiotic co-cultures during the early fermentation period (within 7 days), but was lowest (p<0.05) in T3 during the late fermentation periods (after 14 days). Lactic acid concentration of F-TMR was lowest in T3 at 1 day of fermentation, but was not different from treatments in the other fermentation days. Microbial growth rates of F-TMR reached a peak at 7 days of fermentation, and afterward tended to decrease. In in situ experiment, the DM disappearance rates were higher in T1 than the control during early fermentation times (within 3 hours), but was vice versa at 48 hours of fermentation (p<0.05). There was no significant difference in effective DM degradability among treatments. NDF and ADF disappearance rates in situ were similar to those of DM. From the above results, the supplementation of synbiotics, particularly the mould and bacteria synbiotics, resulted in improving the pH and concentration of lactic acid of F-TMR as parameters of fermentation compare to the control, and also had higher in situ disappearance rates of DM, NDF and ADF than the control at early fermentation time. However, effective DM degradability was not affected by supplementation of synbiotics.

Performance Evaluation of Siemens CTI ECAT EXACT 47 Scanner Using NEMA NU2-2001 (NEMA NU2-2001을 이용한 Siemens CTI ECAT EXACT 47 스캐너의 표준 성능 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.259-267
    • /
    • 2004
  • Purpose: NEMA NU2-2001 was proposed as a new standard for performance evaluation of whole body PET scanners. in this study, system performance of Siemens CTI ECAT EXACT 47 PET scanner including spatial resolution, sensitivity, scatter fraction, and count rate performance in 2D and 3D mode was evaluated using this new standard method. Methods: ECAT EXACT 47 is a BGO crystal based PET scanner and covers an axial field of view (FOV) of 16.2 cm. Retractable septa allow 2D and 3D data acquisition. All the PET data were acquired according to the NEMA NU2-2001 protocols (coincidence window: 12 ns, energy window: $250{\sim}650$ keV). For the spatial resolution measurement, F-18 point source was placed at the center of the axial FOV((a) x=0, and y=1, (b)x=0, and y=10, (c)x=70, and y=0cm) and a position one fourth of the axial FOV from the center ((a) x=0, and y=1, (b)x=0, and y=10, (c)x=10, and y=0cm). In this case, x and y are transaxial horizontal and vertical, and z is the scanner's axial direction. Images were reconstructed using FBP with ramp filter without any post processing. To measure the system sensitivity, NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves were scanned at the center of transaxial FOV and 10 cm offset from the center. Attenuation free values of sensitivity wire estimated by extrapolating data to the zero wall thickness. NEMA scatter phantom with length of 70 cm was filled with F-18 or C-11solution (2D: 2,900 MBq, 3D: 407 MBq), and coincidence count rates wire measured for 7 half-lives to obtain noise equivalent count rate (MECR) and scatter fraction. We confirmed that dead time loss of the last flame were below 1%. Scatter fraction was estimated by averaging the true to background (staffer+random) ratios of last 3 frames in which the fractions of random rate art negligibly small. Results: Axial and transverse resolutions at 1cm offset from the center were 0.62 and 0.66 cm (FBP in 2D and 3D), and 0.67 and 0.69 cm (FBP in 2D and 3D). Axial, transverse radial, and transverse tangential resolutions at 10cm offset from the center were 0.72 and 0.68 cm (FBP in 2D and 3D), 0.63 and 0.66 cm (FBP in 2D and 3D), and 0.72 and 0.66 cm (FBP in 2D and 3D). Sensitivity values were 708.6 (2D), 2931.3 (3D) counts/sec/MBq at the center and 728.7 (2D, 3398.2 (3D) counts/sec/MBq at 10 cm offset from the center. Scatter fractions were 0.19 (2D) and 0.49 (3D). Peak true count rate and NECR were 64.0 kcps at 40.1 kBq/mL and 49.6 kcps at 40.1 kBq/mL in 2D and 53.7 kcps at 4.76 kBq/mL and 26.4 kcps at 4.47 kBq/mL in 3D. Conclusion: Information about the performance of CTI ECAT EXACT 47 PET scanner reported in this study will be useful for the quantitative analysis of data and determination of optimal image acquisition protocols using this widely used scanner for clinical and research purposes.