• 제목/요약/키워드: eye size

Search Result 338, Processing Time 0.034 seconds

Survey Study about Sasangin's Characteristics of Face, Voice, Skin and Pulse Diagnosis (사상인(四象人)의 안면, 음성, 피부 및 맥진 특성에 관한 설문조사 연구)

  • Lee, Jun-Hee;Kim, Yun-Hee;Hwang, Min-Woo;Kim, Jong-Yeol;Lee, Eui-Ju;Song, Il-Byung;Koh, Byung-Hee
    • Journal of Sasang Constitutional Medicine
    • /
    • v.19 no.3
    • /
    • pp.126-143
    • /
    • 2007
  • 1. Objectives The purpose of this study is to find out the grade of practical use, the important element and the significant characteristics of Sasangin' s face, voice, skin and pulse diagnostic impression, in Sasang constitutional clinical diagnosis. 2. Methods We analysed the survey data about Sasangin' s face, voice, skin and pulse diagnostic impression, drawn up by specialist in Sasang constitutional medicine. 3. Results and Conclusions (1) In the application degree of face feature, the case which it was applied with 20-40% and 40-60% were 16 people(43.2%) respectively. In voice, the case applied with 0-20% was 19 people(51.4%), in skin, 0-20% and 20-40% were 14 people(37.8%) respectively and in pulse diagnosis, 0-20% were 25 people(73.0%). (2) In constitutional diagnosis, the important element of face were 'frontal whole shape', 'whole impression' and 'size and shape of eye, ear, mose and mouth', the important element of voice 'speed of speech', 'purity and impurity' and 'pitch', the important element of skin 'thickness', 'feel of touch' and 'size of skin pores' and the important element of pulse diagnosis 'speed of pulse', 'sinking and floating' and 'weakness and firmness'. (3) The important face characteristics of Taeyangin were 'bright eye', 'broad forehead' and 'strong impression', Soyangin 'protruding forehead', 'thin and small lips', 'narrowing and sharp chin', Taeumin 'thick lips', 'flat face', 'large eye, nose, ear and mouth' and Soeumin 'long and slender face', 'downward slanting eyes' and 'small eye, nose, ear and mouth', The important voice characteristics of Taeyangin were 'loud' and 'clear', Soyangin 'rapid' and 'high-pitched tone', Taeumin 'chick', 'slow' and 'low-pitched tone' and Soeumin 'small and feeble' and 'slow'. The important skin characteristics of Taeyangin were 'thin' and 'white', Soyangin 'thin', 'smooth' and 'elastic', Taeumin 'thick', 'large skin-pore', 'coarse' and Soeumin 'soft', 'thin' and 'subtle skin-pore'. The important pulse characteristics of Taeyangin were 'rapid' and 'large', Soyangin 'rapid' and 'floating', Taeumin 'tense', 'long' and 'solid' and Soeumin 'fine', 'weak' and 'slow'.

  • PDF

The Accuracy Assessment of Species Classification according to Spatial Resolution of Satellite Image Dataset Based on Deep Learning Model (딥러닝 모델 기반 위성영상 데이터세트 공간 해상도에 따른 수종분류 정확도 평가)

  • Park, Jeongmook;Sim, Woodam;Kim, Kyoungmin;Lim, Joongbin;Lee, Jung-Soo
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.6_1
    • /
    • pp.1407-1422
    • /
    • 2022
  • This study was conducted to classify tree species and assess the classification accuracy, using SE-Inception, a classification-based deep learning model. The input images of the dataset used Worldview-3 and GeoEye-1 images, and the size of the input images was divided into 10 × 10 m, 30 × 30 m, and 50 × 50 m to compare and evaluate the accuracy of classification of tree species. The label data was divided into five tree species (Pinus densiflora, Pinus koraiensis, Larix kaempferi, Abies holophylla Maxim. and Quercus) by visually interpreting the divided image, and then labeling was performed manually. The dataset constructed a total of 2,429 images, of which about 85% was used as learning data and about 15% as verification data. As a result of classification using the deep learning model, the overall accuracy of up to 78% was achieved when using the Worldview-3 image, the accuracy of up to 84% when using the GeoEye-1 image, and the classification accuracy was high performance. In particular, Quercus showed high accuracy of more than 85% in F1 regardless of the input image size, but trees with similar spectral characteristics such as Pinus densiflora and Pinus koraiensis had many errors. Therefore, there may be limitations in extracting feature amount only with spectral information of satellite images, and classification accuracy may be improved by using images containing various pattern information such as vegetation index and Gray-Level Co-occurrence Matrix (GLCM).

Fabrication of 40 Gb/s Front-End Optical Receivers Using Spot-Size Converter Integrated Waveguide Photodiodes

  • Kwon, Yong-Hwan;Choe, Joong-Seon;Kim, Je-Ha;Kim, Ki-Soo;Choi, Kwang-Seong;Choi, Byung-Seok;Yun, Ho-Gyeong
    • ETRI Journal
    • /
    • v.27 no.5
    • /
    • pp.484-490
    • /
    • 2005
  • We fabricated 40 Gb/s front-end optical receivers using spot-size converter integrated waveguide photodiodes (SSC-WGPDs). The fabricated SSC-WGPD chips showed a high responsivity of approximately 0.8 A/W and a 3 dB bandwidth of approximately 40 GHz. A selective wet-etching method was first adopted to realize the required width and depth of a tapered waveguide. Two types of electrical pre-amplifier chips were used in our study. One has higher gain and the other has a broader bandwidth. The 3 dB bandwidths of the higher gain and broader bandwidth modules were about 32 and 42 GHz, respectively. Clear 40 Gb/s non-return-to-zero (NRZ) eye diagrams showed good system applicability of these modules.

  • PDF

The Effects of Horizontal Eye Movement on Mental Health Indices and Psychophysiological Activities in Healthy Subjects

  • Choi, Kyung-Mook;Min, Jung-Ah;Park, Gewn-Hi;Lee, Seung-Hwan;Chae, Jeong-Ho
    • Korean Journal of Biological Psychiatry
    • /
    • v.18 no.3
    • /
    • pp.148-158
    • /
    • 2011
  • Objectives The eye movement (EM) has been reported to play a role in enhancing the retrieval of episodic memories and reducing effects of fearful episodes in the past and worries for the futures. However, it is still unclear in the mechanism of EM in normal subjects. We examined the horizontal eye movement (HEM) effect using an aiding apparatus on mental health indices including negative and positive psychological factors, and psychophysiological measures such as heart rate variability and quantitative electroencepaholography (qEEG) in healthy subjects. Methods Twenty eight healthy subjects were recruited and randomly allocated into two groups : active HEM group and control group. The active HEM group conducted the HEM training with usual stress management audio-intervention using the apparatus inducing eye movement once a day for 14 days. The control group also conducted the same training once a day for 14 days, however, the saccadic eye movement was not included in this training. Psychological measurements, neurocognitive function tests, heart rate variability measurement and qEEG were conducted before and after the training in both groups. Results In the active HEM group, sleep status using Sleep Quality Scale (SQS) positive factors significantly increased after the training. By contrast, scores on the negative items of Psychological Well-Being Scale (PWBS), and negative items of the Life Orientation Test-Revised (LOT-R) were significantly decreased after the training. The percentage of delta amplitude (1-3 Hz) in qEEG significantly decreased after the HEM training. The percentage of alpha amplitude (8-12 Hz) significantly increased after HEM training. The change of delta amplitude in the active HEM group was positively correlated with the change of sleep satisfaction of Visual Analogue Scale (VAS), and the change of alpha amplitude was negatively correlated with depression of VAS, anxiety of VAS and Beck Anxiety Inventory (BAI). Conclusions The HEM training improved sleep quality and well-being, and sense of optimism. The HEM training also increased alpha amplitude and decreased delta amplitude in qEEG. The qEEG changes were well correlated with subjective improvement of mental health indices in healthy subjects. These results suggest some evidences that HEM training using the apparatus that induces EM would be helpful in improving subjective mental health in healthy subjects. Further study with larger samples size would be needed.

Forward Vehicle Detection Algorithm Using Column Detection and Bird's-Eye View Mapping Based on Stereo Vision (스테레오 비전기반의 컬럼 검출과 조감도 맵핑을 이용한 전방 차량 검출 알고리즘)

  • Lee, Chung-Hee;Lim, Young-Chul;Kwon, Soon;Kim, Jong-Hwan
    • The KIPS Transactions:PartB
    • /
    • v.18B no.5
    • /
    • pp.255-264
    • /
    • 2011
  • In this paper, we propose a forward vehicle detection algorithm using column detection and bird's-eye view mapping based on stereo vision. The algorithm can detect forward vehicles robustly in real complex traffic situations. The algorithm consists of the three steps, namely road feature-based column detection, bird's-eye view mapping-based obstacle segmentation, obstacle area remerging and vehicle verification. First, we extract a road feature using maximum frequent values in v-disparity map. And we perform a column detection using the road feature as a new criterion. The road feature is more appropriate criterion than the median value because it is not affected by a road traffic situation, for example the changing of obstacle size or the number of obstacles. But there are still multiple obstacles in the obstacle areas. Thus, we perform a bird's-eye view mapping-based obstacle segmentation to divide obstacle accurately. We can segment obstacle easily because a bird's-eye view mapping can represent the position of obstacle on planar plane using depth map and camera information. Additionally, we perform obstacle area remerging processing because a segmented obstacle area may be same obstacle. Finally, we verify the obstacles whether those are vehicles or not using a depth map and gray image. We conduct experiments to prove the vehicle detection performance by applying our algorithm to real complex traffic situations.

Welfare Interface using Multiple Facial Features Tracking (다중 얼굴 특징 추적을 이용한 복지형 인터페이스)

  • Ju, Jin-Sun;Shin, Yun-Hee;Kim, Eun-Yi
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.45 no.1
    • /
    • pp.75-83
    • /
    • 2008
  • We propose a welfare interface using multiple fecial features tracking, which can efficiently implement various mouse operations. The proposed system consist of five modules: face detection, eye detection, mouth detection, facial feature tracking, and mouse control. The facial region is first obtained using skin-color model and connected-component analysis(CCs). Thereafter the eye regions are localized using neutral network(NN)-based texture classifier that discriminates the facial region into eye class and non-eye class, and then mouth region is localized using edge detector. Once eye and mouth regions are localized they are continuously and correctly tracking by mean-shift algorithm and template matching, respectively. Based on the tracking results, mouse operations such as movement or click are implemented. To assess the validity of the proposed system, it was applied to the interface system for web browser and was tested on a group of 25 users. The results show that our system have the accuracy of 99% and process more than 21 frame/sec on PC for the $320{\times}240$ size input image, as such it can supply a user-friendly and convenient access to a computer in real-time operation.

A determination of occlusal plane comparing different levels of the tragus to form ala-tragal line or Camper's line: A photographic study

  • Kumar, Sandeep;Garg, Sandeep;Gupta, Seema
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.1
    • /
    • pp.9-15
    • /
    • 2013
  • PURPOSE. The purpose of this study was to determine accurately the part of the tragus to be used to form the Ala-Tragal line or Camper's line in orthognathic profile patients. MATERIALS AND METHODS. 150 dentate subjects with age of 18-40 years with orthognathic profile were sampled. Life-size lateral digital photographs of the face with fox plane were taken in natural head position. Different angles between Eye-Ear plane and occlusal plane ($OT_1$-OP), Eye-Ear plane and ala-superior border of tragus ($OT_1-AT_1$), Eye-Ear plane and ala-middle border of tragus ($OT_1-AT_2$) and Eye-Ear plane and ala-inferior border of tragus ($OT_1-AT_3$) were calculated using computer software package, AutoCAD 2004. From the three angles formed by the Eye-ear plane ($OT_1$ or FH plane) and the ala-tragal lines, the one closest to the angle formed between Eye-Ear plane ($OT_1$) and occlusal plane (OP) was used to determine the occlusal plane of orientation. The obtained results were subjected to ANOVA F test, Tukey's Honestly significant difference test, followed by Karl Pearson coefficient of correlation test. P values of less than 0.05 were taken as statistically significant. RESULTS. The mean of base line angle i.e. $OT_1$-OP angle ($11.96{\pm}4.36$) was found to be close to $OT_1-AT_2$ angle ($13.67{\pm}1.93$) and $OT_1-AT_3$ angle ($10.31{\pm}2.03$), but $OT_1$-OP angle was found to be more closer to $OT_1-AT_3$ angle. Comparison of mean angles showed that $OT_1$-OP angle in both males (11.68) and females (12.51) is close to $OT_1-AT_3$ angle (males- 11.01, females- 11.95). CONCLUSION. The line joining from ala to the lower border of the tragus was parallel to the occlusal plane in 53.3% of the subjects. There was no influence of the sex on the level of occlusal plane.

A Study on the Validity of Bamboo-Bundle System and its Improvement - Analysis of the Component Factors of Bamboo-Bundle System - (현행(現行) 죽재결속법(竹材結束法)의 적정분석(適正分析)과 그의 개선(改善) - 결속구성인자(結束構成因子)의 분석(分析)을 중심(中心)으로 -)

  • Lee, Kwang-Nam
    • Journal of Korean Society of Forest Science
    • /
    • v.25 no.1
    • /
    • pp.49-71
    • /
    • 1975
  • The importance of bamboo as raw material for bamboo wares and several kinds of industrial products is highly appreciated at home and abroad. But different kinds of bamboo-bundle systems have been traditionally used in the local areas. There being no reasonable bamboo-bundle system, we have a lot of difficulty in trading bamboo products and executing adrinistmative works. Therefore, a reasonable bamboo-bundle system based on scientific proofs needs to be tested and established for fair trade and administration. This study is carried out to solve the above difficulty with statistical investigation and analysis. The results obtained are as follows. 1. The larger the circles at eye-height become, the more the possibility of the largest internode covering the span between eye-height and 1/4 height increases. 2. The longest internodes are distributed according to a rule without relation to circles at eye-height. 3. The tapering grade of bamboo culms is very high and its form is almost the same without relation to its size. (Form exponent; 0.71-1.05, eye-height form factor; 0.60-0.66, 1/4 becomes, seeing that the circle grade and the percentage of actual volume height form factor; 0.61-0.69). 4. The larger the circles at eye-height are, the lower the percentage of actual volume have negative curve relation to each other. 5. It is considered that the numbers of bamboos bundled in a "Sok" is not decided according to the usefulness of bamboos, judging from the fact that the outputs of bamboo wares per "Sok" in every circle grade are not the same. 6. As the results of the regression analysis, the empirical formulae of several amounts to circles at eye-height and culm length are as follows; Volume, $${\hat{y}}_i=\bar{3}.821874+2.013181log\;C_i+0.839128log\;H_i$$ $$V=0.0066355\;C^{2.013181}\;H^{0.839128}$$ Actual volume, $${\hat{y}}_{ai}=3.915338+0.776549log\;C_i+1.857000log\;H_i$$ $$V_a=0.0082288\;C^{0.776549}\;H^{1.857000}$$ Weight, $$w_i=3.869148+1.936410log\;C_i+0.566904log\;H_i$$ $$W=0.0073986\;G^{1.936410}\;H^{0.565904}$$ 7. Korean Phyllostachys bambusoides Sieb. et Zucc. is almost the same as that of Japan in several amounts, just the same especially in the weight. 8. It is found that the bamboo-bundle systems of Korea and Japan have much closer relation to the weight than other amounts. So It is, therefore, considered that the weight is important factor in deciding bamboo-bundle system. 9. According to the item 8, I should like to propose the appropriate numbers per "Sok" adjusted on the basis of the weight in the Table 18.

  • PDF

Usefulness assessment of secondary shield for the lens exposure dose reduction during radiation treatment of peripheral orbit (안와 주변 방사선 치료 시 수정체 피폭선량 감소를 위한 2차 차폐의 유용성 평가)

  • Kwak, Yong Kuk;Hong, Sun Gi;Ha, Min Yong;Park, Jang Pil;Yoo, Sook Hyun;Cho, Woong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.87-95
    • /
    • 2015
  • Purpose : This study presents the usefulness assessment of secondary shield for the lens exposure dose reduction during radiation treatment of peripheral orbit. Materials and Methods : We accomplished IMRT treatment plan similar with a real one through the computed treatment planning system after CT simulation using human phantom. For the secondary shield, we used Pb plate (thickness 3mm, diameter 25mm) and 3 mm tungsten eye-shield block. And we compared lens dose using OSLD between on TPS and on simulation. Also, we irradiated 200 MU(6 MV, SPD(Source to Phantom Distance)=100 cm, $F{\cdot}S\;5{\times}5cm$) on a 5cm acrylic phantom using the secondary shielding material of same condition, 3mm Pb and tungsten eye-shield block. And we carried out the same experiment using 8cm Pb block to limit effect of leakage & transmitted radiation out of irradiation field. We attached OSLD with a 1cm away from the field at the side of phantom and applied a 3mm bolus equivalent to the thickness of eyelid. Results : Using human phantom, the Lens dose on IMRT treatment plan is 315.9cGy and the real measurement value is 216.7cGy. And after secondary shield using 3mm Pb plate and tungsten eye-shield block, each lens dose is 234.3, 224.1 cGy. The result of a experiment using acrylic phantom, each value is 5.24, 5.42 and 5.39 cGy in case of no block, 3mm Pb plate and tungsten eye-shield block. Applying O.S.B out of the field, each value is 1.79, 2.00 and 2.02 cGy in case of no block, 3mm Pb plate and tungsten eye-shield block. Conclusion : When secondary shielding material is used to protect critical organ while irradiating photon, high atomic number material (like metal) that is near by critical organ can be cause of dose increase according to treatment region and beam direction because head leakage and collimator & MLC transmitted radiation are exist even if it's out of the field. The attempt of secondary shield for the decrease of exposure dose was meaningful, but untested attempt can have a reverse effect. So, a preliminary inspection through Q.A must be necessary.

  • PDF

Changes in KVA Resulting from Correction Condition of Refractive Error (굴절이상 교정상태에 따른 동적시력 변화)

  • Shim, Hyun-Suk;Kim, Sang-Hyun;Kang, Hye-Sook
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.165-171
    • /
    • 2013
  • Purpose: This study are to analyze and to compare between pupillary size, reaction time, refractive error, corrected vision, dominant eye, static visual angle (SVA) and kinetic visual acuity (KVA) of male and female college students, to measure KVA of them in full correction and to identify changes of KVA by +0.50 D and -0.50 D spherical power addition respectively in full correction condition. Methods: KVA, SVA, pupillary size, reaction time, refractive error, corrected vision and dominant eye of 40 male and 40 female optical science students were measured by utilizing KOWA AS-4A, reaction time measurement program, subjective refractometer, and objective refractometer, and KVAs were measured when +0.50 D/-0.50 D were added in both eyes respectively. Results: Binocular KVA of whole subjects was $0.45{\pm}0.22$, and in monocular KVAs were $0.36{\pm}0.19$ for right eye and $0.34{\pm}0.19$ for left eye, and binocular KVA was significantly higher than monocular KVA. It appeared that the better SVA was, the better KVA was in significant way, and in terms of refractive error the less myopia amount was, the better KVA was, but it was not significant statistically. The lower astigmatism was, the slightly and significantly higher KVA was when dividing between equal or less than -1.00 D astigmatism group and over -1.00 D astigmatism group. In resulting from correction condition of refractive error KVAs were $0.45{\pm}0.22$ for full correction, $0.26{\pm}0.15$ for +0.50 D addition, $0.48{\pm}0.22$ for -0.50 D addition which indicates that KVA in over myopia correction was significantly the highest and followed by full correction and under correction. Similar findings were revealed in both male and female, and KVA of male was better than female in comparing between male and female. There was no significantly different KVA between dominant eye and non-dominant eye. Conclusions: Accordingly, it is concluded that KVA is related with far distance SVA, astigmatism amount, and refractive error amount except a dominant eye. Through this research, it was found that prescription for enhancing KVA is to make full correction or to overcorrect slightly myopia.