• Title/Summary/Keyword: extraction efficiency

Search Result 1,147, Processing Time 0.038 seconds

A Study on Desorption Efficiency of PAHs according to Desorption Solvents by HPLC with Sonication Extraction (탈착용매에 따른 PAHs 흡착매체의 탈착효율 평가 연구)

  • Hong, Jwa-ryung;Lee, Ji-eun;Jung, Myung-Koo;Choi, Kwang-min
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.26 no.3
    • /
    • pp.307-316
    • /
    • 2016
  • Objectives: In general, NIOSH method 5506 is most widely used for the occupational exposure measurement of PAHs, but 2-4 ring PAHs have poor desorption efficiency, especially for a filter. The purpose of this study was to determine a method to increase the desorption efficiency of 16-PAHs using an ultrasonic extraction procedure. Methods: Test samples prepared spiked XAD-2 tubes and PTFE filters in the range of $0.01-1.0{\mu}g/mL$ for desorption efficiency study. Four different extraction solvents, acetonitrile, acetone, tetrahydrofuran and dichloromethane, were tested in order to select the most suitable solvent for the extraction of the 16 PAHs. The addition of dimethyl sulfoxide and sonication time were considered in order to determine the method with the highest extraction efficiency. All samples were made in three sets and analysis was replicated seven times by HPLC. Results: Acetonitrile and acetone were the optimized as an extraction solvent and desorption efficiency of 2-ring PAHs such as naphthalene, acenaphthylene were increased 3~19% with dimethyl sulfoxide for XAD-2. Acetone was the best extraction solvent for PTFE filter and the desorption efficiency was increased 3~13% for 2- to 4-ring PAHs. The optimum sonication time was 60 minutes and desorption efficiency increased with extraction time. Conclusions: As a result, the best extraction solvent was acetone with dimethyl sulfoxide for ultrasonic extraction procedure and the desorption efficiency of this method was better than NIOSH 5506's. This study could be applied as a method for occupational exposure measurement of PAHs.

Ultrasonic Extraction of Phenolic Compounds from Laminaria japonica Aresch Using Ionic Liquid as Extraction Solvent

  • Han, Dandan;Zhu, Tao;Row, Kyung-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.7
    • /
    • pp.2212-2216
    • /
    • 2011
  • An ionic liquid-based ultrasonic-assisted extraction method has been successfully applied to the effective extraction of phenolic compounds from Laminaria japonica Aresch. Three kinds of 1-alkyl-3-methyl-imidazolium with different cations and anions were evaluated for extraction efficiency. The results showed that both the characteristics of anions and cations have remarkable effects on the extraction efficiency. In addition, the ionic liquid-based ultrasonic-assisted extraction procedure was also optimized on some extraction parameters, such as ultrasonic power, extraction time and solid-liquid ratio. Compared with the conventional solvent, the optimum approach gained the highest extraction efficiency within the shortest extraction time. Average recoveries of phenolic compounds were from 75.5% to 88.3% at three concentration levels.

Design of Structure for High-Efficiency LEDs on Patterned Sapphire Substrate (LED용 사파이어 기판의 고효율 패턴 설계)

  • Kang, Ho-Ju;Song, Hui-Young;Jeong, Myung-Yung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.18 no.4
    • /
    • pp.91-95
    • /
    • 2011
  • The light extraction efficiency in GaN based LED was analyzed qualitatively. The extraction efficiency was simulated with patterned shape, depth, size and spacing by using ray-tracing simulation. In simulation result, patterned shape and depth for the optimized extraction efficiency in PSS LED were in indented Hemi-sphere solid. Through the optimal patterning of the various factors, about 40% enhancement in extraction efficiency was obtained.

Effect of an emitting-layer height on a photon extraction efficiency in LED (LED에서 발광층의 높이가 광추출 효율에 미치는 영향)

  • Kwon, Keeyoung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.1
    • /
    • pp.564-569
    • /
    • 2021
  • In this paper, for the typical LED and the tilted LED, when there is no electrode, when 20% absorption (80% reflection) occurs at the electrode, and when 60% absorption (40% reflection) occurs at the electrode, the effect of the absorption at the electrode and the height of the active region on the photon extraction efficiency and the mean photon path length was investigated, and an appropriate height of the active region was proposed. In a typical LED, as the absorption of the electrode increases, the photon extraction efficiency decreases from 18% to 15% and 13%, and the photon extraction efficiency is highest when the height of the active area is located in the center between the two electrodes. In the tilted LED, as the absorption of the electrode increases, the photon extraction efficiency decreases from 38% to 33% and 25%, and the photon extraction efficiency is highest when the height of the active area is located in the center between the two electrodes. The tilted LED can increase the photon extraction efficiency more than twice than that of a typical LED, where photons are trapped inside the chip due to total reflection.

A Comparative Study on the Analytical Methods of Polycyclic Aromatic Hydrocarbons in the Atmosphere (대기 중 다환방향조탄화수소류의 분석 방법간 비교연구)

  • 박찬구;김민영;정동균;모세영
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.6
    • /
    • pp.595-606
    • /
    • 2000
  • In order to compare analytical conditions for measuring PAHs(polycyclic aromatic hydrocarbons) in ambient air, a series of experiment were conducted using three different types of extraction methods that include:(1) accelerated solvent extraction (ASE), (2) soxhlet, and (3) sonification methods. Efficiency and relevant analytixal parameters for each of these methods were examined on five different types of solvents that include:(1) 10% diethyl ether in n-hexane(v/v), (2) dichloromethane, (3)cyclohexane.(4) toluene, and (5) Benzene: ethanol (4:1). Comparison of extraction efficiency for various combinations between methods and solvents was made through an application of both internal and external standard calibration techniques. The extraction efficiency tests, when checked using both internal and external standards, allowed us to derive meaningful comparison among different techniques and among solvents.

  • PDF

A Numerical Study for the Operation of Partial Smoke Extraction System in Tunnel Fire (터널화재시 부분배연설비의 운영방안을 위한 수치해석적 연구)

  • Yoo, Yong-Ho;Lee, Eui-Ju;Shin, Hyun-Jun;Shin, Han-Chol
    • Fire Science and Engineering
    • /
    • v.20 no.2 s.62
    • /
    • pp.72-79
    • /
    • 2006
  • The objective of this study is to analyze the smoke extraction efficiency using by the partial extraction system with CFD simulation for case of tunnel fire. The Comparison of CFD results with the preceding scaled model test results, it is equal to the smoke extraction efficiency and smoke stratification in tunnel by the partial smoke extraction system (distributed damper). It shows that the smoke extraction efficiency is increased about 7% by the distributed damper which is opened near fire, compare with the distributed damper which is all opened. The case of the fire occurs on a traffic jam in a tunnel, it is proposed that the operating method of partial smoke extraction system for the escaping passengers.

Effects of Ethanol Addition on the Efficiency of Subcritical Water Extraction of Proteins and Amino Acids from Porcine Placenta

  • Park, Sung Hee;Kim, Jae-Hyeong;Min, Sang-Gi;Jo, Yeon-Ji;Chun, Ji-Yeon
    • Food Science of Animal Resources
    • /
    • v.35 no.2
    • /
    • pp.265-271
    • /
    • 2015
  • In a previous study, hydrolysates of porcine placenta were obtained and the extraction efficiency for proteins and amino acids was compared between sub- and super-critical water extraction systems; optimum efficiency was found to be achieved using subcritical water ($170^{\circ}C$, 10 bar). In this study, the effects of adding ethanol to the subcritical water system were investigated. The lowest-molecular-weight extraction product detected weighed 434 Da, and the efficiency of extraction for low-molecular-weight products was increased when either the concentration of ethanol was decreased, or the extraction time was lengthened from 10 min to 30 min. The highest concentration of free amino acids (approximately 8 mM) was observed following 30 min extraction using pure distilled water. The concentration of free amino acids was significantly lower when ethanol was added or a shorter extraction time was used (p<0.05). Color change of the solution following extraction was measured. There were no significant differences in color between lysates produced with different extraction times when using distilled water (p>0.05); however, using different extraction times produced significant differences in color when using 20% or 50% ethanol solution for subcritical extraction (p<0.05). The range of pH for the hydrolysate solutions was 6.4-7.5. In conclusion, the investigated extraction system was successful in the extraction of $\leq$ 500 Da hydrolysates from porcine placenta, but addition of ethanol did not yield higher production of low-molecular-weight hydrolysates than that achieved by DW alone.

A Study on Improvement of the Light Emitting Efficiency on Flip Chip LED with Patterned Sapphire Substrate by the Optical Simulation (광학 시뮬레이션을 이용한 Patterned Sapphire Substrate에 따른 Flip Chip LED의 광 추출 효율 변화에 대한 연구)

  • Park, Hyun Jung;Lee, Dong Kyu;Kwak, Joon Seop
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.10
    • /
    • pp.676-681
    • /
    • 2015
  • Recently many studies being carried out to increase the light efficiency of LED. The external quantum efficiency of LED, generally the light efficiency, is determined by the internal quantum efficiency and the light extraction efficiency. The internal quantum efficiency of LED was already reached to more than 90%, but the light extraction efficiency is still insufficient compared with the internal quantum efficiency because the total internal reflection is generated in the interface between the LED chip and air. Thus, we studied about flip chip LED with PSS and performed the optical simulation which find more optimized PSS for flip chip LED to increase the light extraction efficiency. Decreasing of the total internal reflection and effect of diffused reflection according to PSS improved the light extraction efficiency. To get more higher the efficiency, we simulated flip chip with PSS that the parameters are arrangement, edge spacing, radius, height and shape of PSS.

Heavy Metals Extraction from Contaminated Soils using Aqua Regia Extraction (왕수를 이용한 중금속 오염토양에서의 추출방안 연구)

  • Lee, Dukyoung;Jung, Sunkook;Son, Younggyu
    • Journal of Soil and Groundwater Environment
    • /
    • v.23 no.2
    • /
    • pp.15-22
    • /
    • 2018
  • Aqua regia extraction for the quantification of heavy metals and As in contaminated soils was investigated as one of preliminary steps for on-site monitoring using sensor technology. Soil samples were taken from closed railway depot, closed mines, and closed refinery and various extraction conditions including $30^{\circ}C/15min$, $30^{\circ}C/30min$, $30^{\circ}C/60min$, $30^{\circ}C/120min$, $80^{\circ}C/15min$, $80^{\circ}C/30min$, $80^{\circ}C/60min$, $80^{\circ}C/120min$ were tested. The optimal extraction condition was determined as $80^{\circ}C/60min$ because the extraction efficiencies of Zn were relatively low and did not reach the targeted level (80-100% of original concentrations) for $30^{\circ}C$ conditions. It was found that the fractionation of heavy metals and As using the sequential extraction method was useful to understand the degree of metal extraction. In order to enhance the extraction efficiency within short extraction time, ultrasound technology using a 20 kHz horn-type sonicator was additionally used for $30^{\circ}C/15min$. It was revealed that ultrasound could significantly enhance the extraction efficiency and pulsed irradiation showed higher efficiency than continuous irradiation due to the less formation of bubble clouds. However high temperature condition ($80^{\circ}C$) was required to achieve high extraction efficiency for Zn in spite of the use of ultrasound.

Determination of capsaicinoids in red pepper powder using ultra high performance liquid chromatography (초고속 액체크로마토그래피를 이용한 고춧가루의 capsaicinoids 분석)

  • Namgung, Bae;Lee, Yunyeol;Ha, Jaeho
    • Analytical Science and Technology
    • /
    • v.26 no.4
    • /
    • pp.256-261
    • /
    • 2013
  • The efficiency of the two extractions (refluxing extraction and heating-block extraction) was compared to develop the simple analytical method for the determination of capsaicinoids, including capsaicin and dihydrocapsaicin in red pepper powder. For the method development, the parameters, including particle size, extraction time and sample size, were evaluated using ultra high performance liquid chromatography (u-HPLC). It was found that the most effective extraction time of the refluxing extraction was 3 hr. The higher extraction efficiency was obtained with the fine particle of a mild red pepper powder, while the particle size did not affect the extraction efficiency in case of the hot red pepper powder. The higher extraction efficiency was obtained with the small size of sample taken because of the ratio of the large extracting solvent to sample amount. The extraction efficiency of the refluxing method was 3-9% higher than that of the heating-block method, however, the heating-block method could be applied to the determination of capsaicinoids in the red pepper powder for the purpose of quality control of the product.