Browse > Article
http://dx.doi.org/10.15269/JKSOEH.2016.26.3.307

A Study on Desorption Efficiency of PAHs according to Desorption Solvents by HPLC with Sonication Extraction  

Hong, Jwa-ryung (Samsung Health Research Institute, Samsung Electronics Co. Ltd.)
Lee, Ji-eun (Samsung Health Research Institute, Samsung Electronics Co. Ltd.)
Jung, Myung-Koo (Samsung Health Research Institute, Samsung Electronics Co. Ltd.)
Choi, Kwang-min (Samsung Health Research Institute, Samsung Electronics Co. Ltd.)
Publication Information
Journal of Korean Society of Occupational and Environmental Hygiene / v.26, no.3, 2016 , pp. 307-316 More about this Journal
Abstract
Objectives: In general, NIOSH method 5506 is most widely used for the occupational exposure measurement of PAHs, but 2-4 ring PAHs have poor desorption efficiency, especially for a filter. The purpose of this study was to determine a method to increase the desorption efficiency of 16-PAHs using an ultrasonic extraction procedure. Methods: Test samples prepared spiked XAD-2 tubes and PTFE filters in the range of $0.01-1.0{\mu}g/mL$ for desorption efficiency study. Four different extraction solvents, acetonitrile, acetone, tetrahydrofuran and dichloromethane, were tested in order to select the most suitable solvent for the extraction of the 16 PAHs. The addition of dimethyl sulfoxide and sonication time were considered in order to determine the method with the highest extraction efficiency. All samples were made in three sets and analysis was replicated seven times by HPLC. Results: Acetonitrile and acetone were the optimized as an extraction solvent and desorption efficiency of 2-ring PAHs such as naphthalene, acenaphthylene were increased 3~19% with dimethyl sulfoxide for XAD-2. Acetone was the best extraction solvent for PTFE filter and the desorption efficiency was increased 3~13% for 2- to 4-ring PAHs. The optimum sonication time was 60 minutes and desorption efficiency increased with extraction time. Conclusions: As a result, the best extraction solvent was acetone with dimethyl sulfoxide for ultrasonic extraction procedure and the desorption efficiency of this method was better than NIOSH 5506's. This study could be applied as a method for occupational exposure measurement of PAHs.
Keywords
desorption efficiency; PAHs; PTFE; ultrasonic extraction; XAD-2;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Liu LB, Liu Y, Lin JM, Tang N, Hayakawa K et al. Development of analytical methods for polycyclic aromatic hydrocarbons(PAHs) in airborne particulates: A review. J Environ Sci 2007;19:1-11   DOI
2 Mehmet EA, Ozcan S, Tor A. Ultrasonic Solvent Extraction of Persistent Organic Pollutants from Airborne Particles. Clean 2007;35(6):660-668
3 Miege C, Dugay J, Hennion MC. Optimization and validation of solvent and supercritical-fluid extractions for the trace determination of polycyclic aromatic hydrocarbons in sewage sludge by liquid chromatography coupled to diode-array and fluorescence detection. J Chromatogr A 1998;823 (1-2):219-230   DOI
4 NIOSH Institute of Occupational Safety and Health (NIOSH). Polycyclic aromatic hydrocarbons by HPLC: Method 5506. Guidelines for air sampling and analytical method development and evaluation, Cincinnati, OH:NIOSH; 1998
5 Norman AP. Non-aqueous reversed-phase liquid chromatography a neglected approach to the analysis of low polarity samples. J Chromatogr A 1978;157:161-170   DOI
6 Occupational health Guidelines for chemical hazards, NIOSH/OSHA, Jan. 1981, DHHS(NIOSH) publication No. 81-123.
7 Ohura T, Amagai K, Fusaya M, Matsushita H. Polycyclic aromatic hydrocarbons in indoor and outdoor environments and factors affecting their concentration. Environ Sci Technol 2004;38:77-83   DOI
8 Oluseyi T, Olayinka K, Alo B, Roger MS. Comparison of extraction and clean-up techniques for the determination of polycyclic aromatic hydrocarbons in contaminated soil samples. Afr. J Environ Sci Technol 2011;5(7):482-493
9 Ryno M, Rantanen L, Papaioannou E, Konstandopoulos G, Koskentalo T et al. Comparison of pressurized fluid extraction, soxhlet extraction and sonication for the determination of polycyclic aromatic hydrocarbons in urban air and diesel exhaust particulate matter. J Environ Monit 2006;8:488-493   DOI
10 Seo YK, Park DK, Baek SO. Evaluation of a method for the measurement of PAHs in the ambient atmosphere-Focusing on high volume sampling and GC/MS analysis. J Env Hlth Sci 2009;35(4):332-333
11 Sun F, Littlejohn D, Gibson MD. Ultrasonication extraction and solid phase extraction clean-up for determination of US EPA 16 priority pollutant polycyclic aromatic hydrocarbons in soils by reversed-phase liquid chromatography with ultraviolet absorption detection. Analytica chimica Acta 1998;364:1-11   DOI
12 Toriba A, Kuranmae Y, Chetiyanukomkul T, Kizu R, Makino T et al., Quantification of polycyclic aromatic hydrocarbons (PAHs) in human hair by HPLC with fluorescence detection: a biological monitoring method to evaluate the exposure to PAHs. Biomed Chrom 2003;17(2-3):126-132   DOI
13 U.S. National academy of Sciences. PAH-Evaluation of sources and effects 1983;477
14 Van V, Van C, Janssens J. The gas particle distribution of organic aerosol constituents: measurement of the volatilization artifact in hi-vol cascade impactor sampling. Atmos Environ 1984:417-430
15 WHO. Air Quality Guidelines for Europe, World Health Organization Regional Office for Europe, Copenhagen 1987:105-117
16 Yang Y, Hawthorne SB, Miller DJ. Class-selective extraction of polar, moderately polar, and nonpolar organics from hydrocarbon wastes using subcritical water. Environ Sci Technol 1997;31(2): 430-437   DOI
17 Choi HC, Kim KY, Jung KC. Analysis of polynuclear aromatic hydrocarbons(PAHs) and their derivatives in metal working fluids using solid phase extraction and GC/MSD. J Korean Soc Occup Environ Hyg. 2003;13(1):23-34
18 Baek SO. Evaluation of sampling and analytical methods for the determination of polycyclic aromatic hydrocarbons in the ambient atmosphere. J KAPRA 1991;7(1):1-16
19 Baek SO, Kim KN, Choi JS. Determination of polycyclic aromatic hydrocarbons associated with airborne particulate matter using HPLC and fluorescence detection. J Korean Soc Environ Eng 1995;17(1): 85-99
20 Barco BN, Martinez JL, Garrido A, Romero G. Comparison of ultrasonic and pressurized liquid extraction for the analysis of polycyclic aromatic compounds in soil samples by gas chromatography coupled to tandem mass spectrometry. Talanta 2009;78(1):156-164   DOI
21 Clements JB, Lewis RG, Keith LH. Principles of environmental sampling, American chemical society, Washington D.C. 1988
22 International Agency for Research on Cancer (IARC), IARC monograph on the evaluation of the carcinogenic risk of chemicals to human. Polynuclear aromatic compounds. Part I. chemical, environmental and experimental data, vol 32, IARC, Lyon. France, 1983
23 Daniel L, Stephens Jr., McFadden T, Health OD, Mauldin RF. The effect of sonication on the recovery of polycyclic aromatic hydrocarbons from coal stack ash surfaces. Chemosphere 1994;28(1):1741-1747   DOI
24 Department of the Environment and Heritage (DEH). 1999. Technical Report No. 2: Polycyclic Aromatic Hydrocarbons (PAHs) in Australia. Department of the Environment and Heritage, Australian Government, Canberra, Australia. ISBN 642547807 October 1999.
25 Guerin TF. The extraction of aged polycyclic aromatic hydrocarbon (PAH) residues from a clay soil using sonication and a soxhlet procedure: a comparative study. J Environ Monit 1999;1:63-67   DOI
26 Gyula K, Zita VP, Jozsef H. Determination of polycyclic aromatic hydrocarbons in precipitation using solidphase extraction and column liquid chromatography. J Chromatogra A 1996;725:261-272   DOI
27 Hong JR & Choi KM. Analytical characteristics of GC/MS and HPLC according to the concentration distribution of PAHs. J Korean Soc Occup Environ Hyg. 2015; 25(3):312-321   DOI
28 Kaufmann A, Jegle U, Dreyer A, Ingelheim B, Ronald E. Using DMSO as an injection solvent to increase sample load in preparative LC. Agilent technologies, 2005
29 Kayali MN, Rubio S, Diaz CA, Polo LM. Rapid determination of PAHs in soil samples by HPLC with fluorimetric detection following sonication extraction. Fresenius J Anal Chem 2000;368: 697-701   DOI
30 Kilian EC, Grant LN, Kevin CJ. Influence of the extraction methodology on the analysis of polycyclic aromatic hydrocarbons in pasture vegetation. J Chromatogr A 2006;1116(1-2):20-30   DOI
31 Lau EV, Gan S, Ng HK. Extraction techniques for polycyclic aromatic hydrocarbons in soils. International journal of analytical chemistry 2010