• Title/Summary/Keyword: external standard method

Search Result 249, Processing Time 0.033 seconds

Hybrid Stress Analysis around a Circular Hole in a Tensile Plate by Use of Phase Shifting Photoelasticity (광탄성 위상이동법에 의한 인장시편 원형 구멍주위 하이브리드 응력해석)

  • Baek, Tae-Hyun;Lee, Choon-Tae;Yang, Min-Bok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.1
    • /
    • pp.15-22
    • /
    • 2007
  • A hybrid experimental-numerical method is presented for determining the stresses around a circular hole in a finite-width, tensile loaded plate. Measured fringe orders along straight lines provided the input information on the external boundary of the hybrid element. In order to see the effects of varying stress field, different numbers of terms in a power-series representation of the complex type conformal mapping stress function were tested. For qualitative comparison, actual isochromatic fringes were compared with reconstructed theoretical fringes using stress-optic law. For quantitative comparison, relative errors and standard deviations with respective to relative errors were analyzed for all measured points by changing the number of terms of stress function. The hybrid results are highly comparable with those predicted by FEA. The results show that this approach is effective and promising because isochromatic data along the straight lines in photoelasticity can be conveniently measured by use of phase shifting photoelasticity.

Electromagnetic Wave Shielding Effectiveness Measurement Method of EMP Protection Facility (EMP 방호시설의 전자파 차폐효과 측정 방법)

  • Seo, Manjung;Chi, Seongwon;Kim, Youngjin;Park, Woochul;Kang, Hojae;Huh, Changsu
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.5
    • /
    • pp.548-558
    • /
    • 2014
  • EMP(Electromagnetic Pulse) protection facility was evaluated according to standard of shielding effectiveness. To comply with the standard, transmitting antenna was placed on outside of protection facility and receiving antenna was placed on inside of protection facility. However, measurement is impossible that place does not have enough space between protection facility and external concrete structure. In this paper, we performed a various of tests that put transmitting antenna inside the EMP protection facility in order to find out test method for measuring the shielding effectiveness of electromagnetic wave. Transmitting antenna was placed on inside of the EMP protection facility for measuring the shielding effectiveness to compare and analyze the impact of the position regarding to the transmitting and receiving antenna. As a result of test, in case that transmitting antenna was placed on inside of the EMP protection facility, it was found that test frequency range 10 kHz~1 GHz were occurred overall average difference of ${\pm}4$ dB level.

A study on the improved headway calculating method in the metropolitan railway system (광역철도 운행시격 산정방법의 문제점 및 개선방안에 관한 연구)

  • Park, Chul-Ho;Kim, Byoung-Seop;No, Sun-Hwa;Jang, Seong Yong
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.921-932
    • /
    • 2010
  • Metropolitan railway headway is calculated and decided by external conditions such as appropriate level of service and competitiveness rather than passenger demand for the peak time which is based on transport passenger capability of train. On contrast of inter-city urban railways, train time intervals of sub-urban metropolitan railway were fixed more than 20 mins in the peak time which results in low level of convenience. Big gap of headway brings a vicious circle of deteriorating competitiveness and decreasing the number of customers. Also this time gap of train interval results in stagnation of passenger demand, and makes it difficult to reduce headway. This thesis is a basic research to identify headway problems and their solutions of metropolitan railway. This thesis suggests passenger demand and the calculated standard for setting the headway, and reviews the level of passenger crowdedness, the numbers of coach for each train and time-competitiveness. At the last, thesis suggests the need for making headway by means of train services throughout benefit & cost analysis. And it also recommends the improved calculating method of setting up headway considering the different train headway standards by regional situation, flexibility in the number of coaches for a train, government policy to activate railway business and the need for setting up the standard for train service level.

  • PDF

A study on the standard for determining airborne sound insulation performance of sound barrier panels (방음판의 음향투과손실 측정규격에 관한 연구)

  • Oh, Yang Ki
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.3
    • /
    • pp.302-311
    • /
    • 2022
  • Sound barrier walls are one of the most effective alternatives for reducing environmental noise on roads and railways in the city center. The insertion loss of the sound barrier against road traffic noise is the sum of the sound transmission loss, sound absorption loss, and sound energy reduction due to the diffraction attenuation of the sound barrier. The sound transmission loss of the sound barrier is one of the important factors that determine the insertion loss of the sound barrier and is a basic indicator that determines the performance of the sound barrier. Nevertheless, there is not a separate standard in Korea for measuring the acoustic transmission loss of sound barrier panels. There are only a few conditions in KS F 4770 series that stipulates on the general material of sound barrier panels. This thesis examines the necessity of the acoustic transmission loss measurement and evaluation standards of sound barrier walls, and seeks a measurement method in a free sound field (anechoic chamber) sound receiving room considering the characteristics of sound barrier walls installed in external spaces, unlike indoor building materials. In addition, a single number evaluation method using a reference spectrum was proposed so that the sound insulation effect according to various installation places such as roadside or railroad side can be easily displayed.

Optimization Analysis for Embodied Energy and CO2 Emission in Reinforced Concrete Column Using Sustainable Design Method (지속가능 설계법을 이용한 철근 콘크리트 기둥의 내재에너지 및 이산화탄소 배출 최적화 해석)

  • Kim, Kyeong-Hwan;Yeo, DongHun;Lee, Sang-Ho;Yoon, Young-Cheol
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.30 no.3
    • /
    • pp.265-274
    • /
    • 2017
  • This study presents a sustainable design method to optimize the embodied energy and $CO_2$ emission complying with the design code for reinforced concrete column. The sustainable design method effectively achieves the minimization of the environmental load and energy consumption whereas the conventional design method has been mostly focused on the cost saving. Failure of reinforced concrete column exhibits compressive or tensile failure mode against an external force such as flexure and compression; thus, optimization analyses are conducted for both failure modes. For the given sections and reinforcement ratios, the optimized sections are determined by optimizing cost, embodied energy, and $CO_2$ emission and various aspects of the sections are thoroughly investigated. The optimization analysis results show that 25% embodied energy and 55% $CO_2$ emission can be approximately reduced by 10% increase in cost. In particular, the embodied energy and $CO_2$ emission were more effectively reduced in the tensile failure mode rather than in the compressive failure mode. Consequently, it was proved that the sustainable design method effectively implements the concept of sustainable development in the design of reinforced concrete structure by optimizing embodied energy consumption and $CO_2$ emission.

The DEVS-based Detailed Implementation Method of the Command and Fire Control System for the Underwater Vehicle DEVS-HLA Simulation in the Engagement Level (교전급 수중운동체 DEVS-HLA 시뮬레이션을 위한 전술통제체계의 DEVS 기반 상세 구현 방법)

  • Son, Myeong-Jo;Cha, Ju-Hwan;Kim, Tae-Wan;Lee, Kyu-Yeul;Nah, Young-In
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.47 no.4
    • /
    • pp.628-645
    • /
    • 2010
  • To perform the engagement level simulation between the underwater vehicle model and the surface model those are constituted with various systems/ sub-systems, we implemented four different federates as a federation according to the IEEE 1516 HLA (High Level Architecture) protocol that is the international standard in the distributed simulation. Those are CFCS (Command and Fire Control System) federate, motion federate, external entities (torpedos, countermeasure and surfaceship) federate, and visualization federate that interacts with OSG (Open Scene Graph)-based visualization rendering module. In this paper, we present the detailed method about the model constitution for discrete event simulation in the distributed environment. For the sake of this purpose, we introduce the DEVS (Discrete Event System Specification)-HLA-based modeling method of the CFCS federate that reflects not only the interations between models, but also commands from user and tactics manager that is separated from the model. The CFCS federate makes decisions in various missions such as the normal diving, the barrier misision, the target motion analysis, the torpedo launch, and the torpedo evasion. In the perspective of DEVS modeling, the CFCS federate is the coupled model that has the tactical data process model, command model and fire control model as an atomic model. The message passing and time synchronization with other three federates are settled by the $m\ddot{a}k$ RTI (Runtime Infrastructure) that supports IEEE 1516. In this paper, we provides the detailed modeling method of the complicated model that has hierarchical relationship such as the CFCS system in the submarine and that satisfies both of DEVS modeling method for the discrete event simulation and HLA modeling method for the distributed simulation.

Reliability-Optimal Design Method of High-Speed Railway Bridges Based upon Expected Life-Cycle Cost (기대생애주기비용에 기초한 고속철도교량의 신뢰성-최적설계 방안)

  • Lee, Woo-Sang;Bang, Myung-Seok;Han, Sung-Ho;Lee, Chin-Ok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.4
    • /
    • pp.102-110
    • /
    • 2010
  • The reliability evaluation may be a efficient method for estimating of the quantitative structural safety considering the effect of uncertainties included in high-speed railway bridges. The expected life-cycle cost(LCC) based upon the reliability evaluation will reasonably offer the safety level and design criteria of high-speed railway bridges. Therefore, this study determined the expected life-cycle cost and optimal design method of high-speed railway bridges on the basis of the result of the numerical analysis and reliability evaluation. For this, after creating various design method based upon the standard design of high-speed railway bridges, the numerical analysis is conducted on each of the alternative design methods. The reliability evaluation by the design strength limit state function is conducted considering the effect of external uncertainties on the basis of the numerical analysis result. The expected life-cycle cost of high-speed railway bridges is calculated on the basis of the reliability evaluation result by each of the alternative design methods. Also, the optimal design method is determined using the calculated expected life-cycle cost. In addition, The result of reliability evaluation and expected life-cycle cost of optimal design method are examined considering the effect of internal uncertainties. It is expected that the result of this study can be used as a basic information for the systematic safety evaluation and optimal structure design of high-speed railway bridges.

Six Sigma Analysis of Vitamin D Measurement Using External Quality Assessment Program (외부정도관리 프로그램을 이용한 비타민 D 검사의 6 시그마 분석)

  • Ji, Myungsuk
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.52 no.2
    • /
    • pp.91-97
    • /
    • 2020
  • Standardization of vitamin analysis continues around the world, and much effort has been made to improve the accuracy of the results. This study analyzed the sigma metrics of the vitamin D test using the external quality assessment (EQA) program. Sigma metrics is used for quantitative tests performed in the laboratory, and the test results can be objectively visualized in terms of quality. This analysis was performed based on the accuracy of the College of American Pathologists (CAP) using the results of the 2019 accuracy-based vitamin D (ABVD) survey, and about 300 laboratories participated in the survey. Reference values were obtained by the Center for Disease Control and Prevention (CDC) reference laboratory. At six different concentrations, the sigma metrics were analyzed to be 1.00, 1.85, 2.42, 1.01, 1.54 and 0.78, respectively. An average of 1.43 sigma metrics was determined. In particular, only positive biases for ABVD-16 and 17 were shown in the liquid chromatography tandem-mass spectrometry (LC-MS/MS), which is the standard method for vitamin D determination when compared to the reference values. The causes of the difference can be explained by cross reactivity to various vitamin D metabolites. Laboratories need to improve their overall performance.

A Study on Stability and Economic feasibility according to Height on the MSE Wall with Pacing Panel (고속도로 도로부에 시공된 패널식 보강토 옹벽의 높이별 안전율과 경제성 검토)

  • Park, Min-Cheol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.5
    • /
    • pp.54-63
    • /
    • 2018
  • In this study, the stability and economic feasibility of a MSE (Mechanically stability earth) wall with a pre-cast concrete pacing panel was investigated for a standard section of highway. Based on the design criteria, the MSE walls of the panel type were designed considering the load conditions of the highway, such as the dead load of the concrete pavement, traffic load, and impact load of the barrier. The length of the ribbed metal strip was arranged at 0.9H according to the height of the MSE walls. Because the length of the reinforcement was set to 0.9H according to the height of the MSE wall, the external stability governed by the shape of the reinforced soil was not affected by the height increase. The factor of safety (FOS) for the bearing capacity was decreased drastically due to the increase in self-weight according to the height of the MSE wall. As a result of examining the internal stability according to the cohesive gravity method, the FOS of pullout was increased and the FOS of fracture was decreased. As the height of the MSEW wall increases, the horizontal earth pressure acting as an active force and the vertical earth pressure acting as a resistance force are increased together, so that the FOS of the pullout is increased. Because the long-term allowable tensile force of the ribbed metal strip is constant, the FOS of the fracture is decreased by only an increase in the horizontal earth pressure according to the height. The panel type MSE wall was more economical than the block type at all heights. Compared to the concrete retaining wall, it has excellent economic efficiency at a height of 5.0 m or more.

The Effect of Barrel Vibration Intensity to the Plating Thickness Distribution

  • Lee, Jun-Ho;Roselle D. Llido
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 1999.10a
    • /
    • pp.15-15
    • /
    • 1999
  • In chip plating, several parameters must be taken into consideration. Current density, solution concentration, pH, solution temperature, components volume, chip and media ratio, barrel geometrical shape were most likely found to have an effect to the process yields. The 3 types of barrels utilized in chip plating industry are the conventional rotating barrel. vibrational barrel (vibarrel), and the centrifugal type. Conventional rotating barrel is a close type and is commonly used. The components inside the barrel are circulated by the barrel's rotation at a horizontal axis. Process yield has known to have higher thickness deviation. The vibrational barrel is an open type which offers a wide exposure to electrolyte resulting to a stable thickness deviation. It rotates in a vertical axis coupled with multi-vibration action to facilitate mixed up and easy transportation of components, The centrifugal barrel has its plated work centrifugally compacted against the cathode ring for superior electrical contact with simultaneous rotary motion. This experiment has determined the effect of barrel vibration intensity to the plating thickness distribution. The procedures carried out in the experiment involved the overall plating process., cleaning, rinse, Nickel plating, Tin-Lead plating. Plating time was adjusted to meet the required specification. All other parameters were maintained constant. Two trials were performed to confirm the consistency of the result. The thickness data of the experiment conducted showed that the average mean value obtained from higher vibrational intensity is nearer to the standard mean. The distribution curve shown has a narrower specification limits and it has a reduced variation around the target value, Generally, intensity control in vi-barrel facilitates mixed up and easy transportation of components, However, it is desirable to maintain an optimum vibration intensity to prevent solution intrusion into the chips' internal electrode. A cathodic reaction can occur in the interface of the external and internal electrode. $2HD{\;}+{\;}e{\;}{\rightarrow}20H{\;}+{\;}H_2$ Hydrogen can penetrate into the body and create pressure which can cause cracks. At high intensity, the chip's motion becomes stronger, its contact between each other is delayed and so plating action is being controlled. However, the strong impact created by its collision can damage the external electrode's structure thereby resulting to bad plating condition. 1 lot of chip was divided into two equal partion. Each portion was loaded to the same barrel one after the other. Nickel plating and tin-lead plating was performed in the same station. Portion A maintained the normal barrel vibration intensity and portion B vibration intensity was increased two steps higher. All other parameters, current, solution condition were maintained constant. Generally, plating method find procedures were carried out in a best way to maintained the best plating condition. After plating, samples were taken out from each portion. molded and polished. Plating thickness was investigated for both. To check consistency of results. 2nd trial was done now using different lot of another characteristics.

  • PDF