• Title/Summary/Keyword: external heat

Search Result 875, Processing Time 0.031 seconds

Evaluation of Thermal Environment of External Space following the Fence Demolition Campaign in Detached Housing Area (담장허물기로 인한 주택지 외부공간의 열환경 평가)

  • Ryu, Ji-Won;Jung, Eung-Ho;Shimizu, Aki;Oh, Sang-Hak;Hoyano, Akira
    • Journal of the Korean housing association
    • /
    • v.23 no.1
    • /
    • pp.19-26
    • /
    • 2012
  • This study examines how fence demolition may change the thermal environments of external spaces of houses and suggests what factors need to be considered when a fence is demolished. The results of the research are summarized as follows. In terms of the surface temperature, there was no significant difference in all time plots after the removal of all materials. However, applying greening methods (changing the surface materials, planting trees, and building a green roof following fence demolition) could lower the surface temperatures, calling for proper plans for various greening methods. The MRT results indicates that walls block solar radiation and provide shade, reducing radiant heat from roads and surrounding structures during the daytime when solar radiation directly effects surface temperatures. Also, the application of greening methods such as planting vegetation and trees could have shading and evapotranspiration effects, leading to a lower temperature distribution. The HIP results were similar to the MRT results. They indicated that walls block solar radiation within the residential sections and provide shade, resulting in a lower temperature distribution during the daytime. However, areas where greening methods such as a green roof or tree planting were applied showed $1{\sim}2^{\circ}C$ difference in temperature distribution.

Evaluation on the Properties of Fire Retardant Surface Preparation Mortars (화재 지연형 바탕조정재의 기초물성 평가에 관한 연구)

  • Ryu, Hwa-Sung;Shin, Sang-Heon;Kim, Deuck-Mo;Song, Sung-Yong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.6
    • /
    • pp.559-567
    • /
    • 2018
  • In the case of fire, surface treatment agents used in external insulation finishing methods are substances that are vulnerable to fire due to thin finishes and the combustion of polymers. In this study, it was expected that the performance of surface preparation mortars could be improved by using expandable graphite with excellent thermal performance. Experimental results showed that the mechanical properties of surface preparation mortar were improved by using the fly ash and silica fume. Surface treatment materials using expanded graphite have a characteristic of expanding when a fire occurs. It has been shown that heat-swellable surface treatment materials can reduce the penetration of heat sources into the surface of synthetic insulation.

Field Attenuation of Foam Earplugs

  • Copelli, Fran;Behar, Alberto;Le, Tina Ngoc;Russo, Frank A.
    • Safety and Health at Work
    • /
    • v.12 no.2
    • /
    • pp.184-191
    • /
    • 2021
  • Background: Hearing protection devices (HPDs) are often used in the workplace to prevent hearing damage caused by noise. However, a factor that can lead to hearing loss in the workplace is improper HPD fitting, and the previous literature has shown that instructing workers on how to properly insert their HPDs can make a significant difference in the degree of attenuation. Methods: Two studies were completed on a total of 33 Hydro One workers. A FitCheck Solo field attenuation estimation system was used to measure the personal attenuation rating (PAR) before and after providing one-on-one fitting instructions. In addition, external ear canal diameters were measured, and a questionnaire with items related to frequency of use, confidence, and discomfort was administered. Results: Training led to an improvement in HPD attenuation, particularly for participants with poorer PARs before training. The questionnaire results indicated that much HPD discomfort is caused by heat, humidity, and communication difficulties. External ear canal asymmetry did not appear to significantly influence the measured PAR. Conclusion: In accordance with the previous literature, our studies suggest that one-on-one instruction is an effective training method for HPD use. Addressing discomfort issues from heat, humidity, and communication issues could help to improve the use of HPDs in the workplace. Further research into the effects of canal asymmetry on the PAR is needed.

Modeling and validation of a parabolic solar collector with a heat pipe absorber

  • Ismail, Kamal A.R.;Zanardi, Mauricio A.;Lino, Fatima A.M.
    • Advances in Energy Research
    • /
    • v.4 no.4
    • /
    • pp.299-323
    • /
    • 2016
  • Cylindrical parabolic solar concentrators of small concentration ratio are attractive options for working temperatures around $120^{\circ}C$. The heat gained can be utilized in many applications such as air conditioning, space heating, heating water and many others. These collectors can be easily manufactured and do not need to track the sun continuously. Using a heat pipe as a solar absorber makes the system more compact and easy to install. This study is devoted to modeling a system of cylindrical parabolic solar concentrators of small concentration ratio (around 5) fitted with a heat pipe absorber with a porous wick. The heat pipe is surrounded by evacuated glass tube to reduce thermal losses from the heat pipe. The liquid and vapor flow equations, energy equation, the internal and external boundary conditions were taken into consideration. The system of equations was solved and the numerical results were validated against available experimental and numerical results. The validated heat pipe model was inserted in an evacuated transparent glass tube as the absorber of the cylindrical parabolic collector. A calculation procedure was developed for the system, a computer program was developed and tested and numerical simulations were realized for the whole system. An experimental solar collector of small concentration, fitted with evacuated tube heat pipe absorber was constructed and instrumented. Experiments were realized with the concentrator axis along the E-W direction. Results of the instantaneous efficiency and heat gain were compared with numerical simulations realized under the same conditions and reasonably good agreement was found.

A Literature Study about Comparison of Eastern-Western Medicine on the Acne (여드름의 동(東)·서의학적(西醫學的) 문헌(文獻) 고찰(考察))

  • Joo, Hyun-A;Bae, Hyeon-Jin;Hwang, Chung-Yeon
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.25 no.2
    • /
    • pp.1-19
    • /
    • 2012
  • Objective : The purpose of this study is to investigate about comparison of Eastern-Western medicine on the acne. Methods : We searched Eastern and Western medicine books for acne. We analyzed these books and examined category, definition, etiology, classification, internal and external methods of treatment of acne. Results : The results were as follows. 1. In Eastern medicine, Acne belongs to the category of the Bunja(粉刺), Jwachang(痤瘡), Pyepungbunja(肺風粉刺). In Western medicine, the other name of Acne is acne vulgaris. 2. In Eastern medicine, the definition of Acne includes manual extraction of comedones and skin appearance. In Western medicine, Acne is a common skin disease during adolescence and a chronic inflammatory disease of pilosebaceous unit of self localization. It is characterized by noninflammatory, open or closed comedones and by inflammatory papules, pustules, and nodules and it affects the areas of skin with the densest population of sebaceous follicles, these areas include the face, neck, back, and the upper part of the chest. 3. In Eastern medicine, the cause and mechanism of Acne arose from the state of internal dampness-heat and spleen-stomach internal qi deficiency due to dietary irregularities and then invaded external pathogen such as wind-dampness-heat-cold-fire in lung meridian lead to qi and blood heat depression stagnation. So it appears in skin. In Western medicine, the etiology and pathogenesis of Acne is clearly not identified, but there are most significant pathogenic factors of blood heat depression stagnation. So it appears in skin. In Western medicine, the etiology and pathogenesis of Acne is clearly not identified, but there are most significant pathogenic factors of Acne; Androgen-stimulated production of sebum, hyperkeratinization and obstruction of sebaceous follicles, proliferation of Propionibacterium acnes and inflammation, abnormaility of skin barrier function, genetic aspects, environmental factors etc. 4. In Eastern medicine, differentiation of syndromes classifies clinical aspects, and cause and mechanism of disease; the former is papular, pustular, cystic, nodular, atrophic, comprehensive type; the latter is lung blood heat, intestine-stomach dampness-heat, phlegm-stasis depression, thoroughfare-conception disharmony, heat toxin type. In Western medicine, it divides into an etiology and invasion period, and clinical aspects; Acne neonatorum, Acne infantum, Acne in puberty and adulthood, Acne venenata; Acne vulgaris, Acne conglobata, Acne fulminans, Acne keloidalis. 5. In Eastern medicine, Internal methods of treatment of Acne are divided into five treatments; general treatments, the treatments of single-medicine and experiential description, the treatments depending on the cause and mechanism of disease, and clinical differentiation of syndromes, dietary treatments. In Western medicine, it is a basic principles that regulation on production of sebum, correction on hyperkeratinization of sebaceous follicles, decrease of Propionibacterium acnes colony and control of inflammation reaction. Internal methods of treatment of Acne are antibiotics, retinoids, hormone preparations etc. 6. In Eastern medicine, external methods of treatment of Acne are wet compress method, paste preparation method, powder preparation method, pill preparation method, acupuncture and moxibustion therapy, ear acupuncture therapy, prevention and notice, and so on. In Western medicine, external method of treatments of Acne are divided into topical therapy and other surgical therapies. Topical therapy is used such as antibiotics, sebum regulators, topical vitamin A medicines etc and other surgical therapies are used such as surgical treatments, intralesional injection of corticosteroids, skin dermabrasion, phototherapy, photodynamic therapy, and so on. Conclusions : Until now, there is no perfect, effective single treatment. We think that Eastern medicine approach and treatment can be helpful to overcome the limitations of acne cure.

Hall Effect on Couette Flow with Heat Transfer of a Dusty Conducting Fluid Between Parallel Porous Plates Under Exponential Decaying Pressure Gradient

  • Attia Hazem A.
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.569-579
    • /
    • 2006
  • In the present study, the unsteady Couette flow with heat transfer of a dusty viscous incompressible electrically conducting fluid under the influence of an exponential decaying pressure gradient is studied without neglecting the Hall effect. The parallel plates are assumed to be porous and subjected to a uniform suction from above and injection from below while the fluid is acted upon by an external uniform magnetic field is applied perpendicular to the plates. The governing equations are solved numerically using finite differences to yield the velocity and temperature distributions for both the fluid and dust particles.

Analysis and design of LNG open rack vaporizer (LNG 개방래크 기화기의 해석 및 설계)

  • Park, J.S.;Chang, H.M.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.2
    • /
    • pp.189-197
    • /
    • 1997
  • The vaporizing characteristics of LNG(liquefied natural gas) via heat exchanger with sea water are analytically studied for an open rack vaporizer(ORV). This study is intended to supply the design data for the domestic fabrication of the corrosion-resistant vaporizer tube. A computational program is developed to predict the exit temperature of LNG for various conditions. In the program, thesimple and justifiable heat transfer models are selected for fully-developed internal flow of LNG, the star-shaped finned-tube, and the external falling films of sea water, as well as the possible ice formation and the fouling on the tube walls. It is found that the enongh corrugation inside of the tube wall is the most significant in the vaporizer performance for the current operating conditions. the effects of other design parameters on the heat exchanger between LNG and sea water are quantitatively presented.

  • PDF

Effect of elevated air temperature on shell-and-tube Nafion membrane humidifier in PEMFC system (PEMFC시스템의 공기 공급 온도 변화에 따른 중공사형 나피온 막가습기의 성능특성)

  • Yoon, Jae-Eun;Jang, Hyo-sun;Hwang, Jun-Young;Kang, Kyung-Tae
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.345-348
    • /
    • 2009
  • Maintaining proper membrane humidity is crucial to ensure optimal operation of a PEMFC system. A gas-to-gas membrane humidifier is popular technology for external humidification of PEMFC reactant gases. Characteristics of heat and water transfer in shell-and-tube Nafion membrane humidifiers has been experimentally investigated for various dry side inlet temperature of membrane humidifier. The results show that heat flux decreases linearly with dry side inlet temperature of membrane humidifier. The water flux through the membrane varies nonlinearly with the temperature elevation.

  • PDF

Syunthesis of Silica Aerogel at Ambient Pressure and Characterization (I) (실리카에어로겔의 상압합성 및 특성연구(I))

  • 강신규;최세영
    • Journal of the Korean Ceramic Society
    • /
    • v.33 no.12
    • /
    • pp.1394-1402
    • /
    • 1996
  • The Silica gel with the density of 0.2g/cm3 and porosity of 90% was synthesized. The silica wet gel was dried and heat-treated under the ambient pressure after modification of the wet gel surface by TMCS. Specific surface area total pore volume and mean pore radius of dried gel were all increased with increasing heat treatment temperature and confirmed about 1400m2/g, 4.5cc/g and 8 nm respectively after heat treatment above 25$0^{\circ}C$. But the pore size distribution of dried gel was in the range of 1-100nm and was almost indepen-dent of temperature. As the result of external shape pore characteristics and microstructure of gel using SEM similar properties were observed between the silica gel synthesized in this study and the silica aerogel through the super critical drying.

  • PDF

Hall Effect on Unsteady Couette Flow. with Heat Transfer Under Exponential Decaying Pressure Gradient

  • Attia HazemAIi
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.11
    • /
    • pp.2053-2060
    • /
    • 2005
  • The unsteady Couette flow of an electrically conducting, V1SCOUS, incompressible fluid bounded by two parallel non-conducting porous plates is studied with heat transfer taking the Hall effect into consideration. An external uniform magnetic field and a uniform suction and injection are applied perpendicular to the plates while the fluid motion is subjected to an exponential decaying pressure gradient. The two plates are kept at different but constant temperatures while the Joule and viscous dissipations are included in the energy equation. The effect of the ion slip and the uniform suction and injection on both the velocity and temperature distributions is examined.