• Title/Summary/Keyword: external circuit

Search Result 489, Processing Time 0.036 seconds

Specification-based Current Test for Mixed-signal Circuits and Optimal Test Point Selection (혼합신호 회로를 위한 Specification 기반의 전류 테스트와 최적의 테스트 포인트 선택)

  • Jang, Sang-Hoon;Lee, Jae-Min
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.901-904
    • /
    • 2005
  • Testing of mixed-signal circuit has become a difficult task for test engineers and efficient test solution to these problems are needed. In this paper a new specification-based mixed-signal test method called TSS(Time Slot Specification) using high performance current sensors and a novel test point selection technique without heavy computational overhead are proposed. External output and power nodes are used for test points and accessed by the current sensors in the ATE.

  • PDF

Hysteresis Modeling of the Sealed Flooded Lead Acid Battery for SOC Estimation (SOC 추정을 위한 밀폐형 Flooded 연축전지의 히스테리시스 모델링)

  • Khan, Abdul Basit;Choi, Woojin
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.309-310
    • /
    • 2016
  • Sealed flooded lead acid batteries are becoming popular in the industry because of their low cost as compared to their counterparts. State of Charge (SOC) estimation has always been an important factor in battery management systems. For the accurate SOC estimation, open circuit voltage (OCV) hysteresis should be modelled accurately. The hysteresis phenomenon of the sealed flooded lead acid battery is discussed in detail and its ultimate modeling is proposed based on the conventional parallelogram method. The SOC estimation is performed by using Unscented Kalman Filter (UKF) while the parameters of the battery are estimated using Auto Regressive with external input (ARX) method. The validity of the proposed method is verified by the experimental results. The SOC estimation error by the proposed method is less than 3 % all wing the 125hr test.

  • PDF

Testbed Design of PWM Controlled High Voltage Relay (PWM 제어용 고전압 릴레이의 테스트베드 설계)

  • Kim, Jin-Kwang
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.20 no.5
    • /
    • pp.419-424
    • /
    • 2017
  • The purpose of this study is to develop a virtual testbed capable of predicting the functional performance of a linear electromagnetic actuator for a high voltage relay in order to reduce its development costs and time. The virtual testbed is defined by a multiphysics coupling approach in order to consider the complex interactions of multi-domains such as the solenoid model of electromagnets, the mass-spring-damper model of mechanical systems, the electric circuit model for an external control unit, and the thermal model for predicting temperature variations. The performances of the existing high voltage relay were estimated by the virtual testbed, and then the effectiveness and validation of the proposed testbed were discussed in comparison with the experimental test results. This study showed that the virtual testbed can be applied in design, optimization, and investigation of high voltage relays.

Self-Sensing Electrostatic Suspension System (자가 검출 방식을 이용한 정전 부상 시스템)

  • 정학근;최창환;박기환
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.6 no.6
    • /
    • pp.454-461
    • /
    • 2000
  • Electrostatic suspension offers an advantage of directly suspending various materials such as conductive materials, semiconductors and dielectric materials without any mechanical contacts. This is a specific feature compared with electromagnetic suspension which can suspend only ferro-magnetic material. In general, the electrostatic suspension systems require position sensors for stabilizing the suspended object. Therefore, a lot of displacement sensors and a switching circuit are required for moving the object through a long distance. In order to circumvent this problem, this paper proposes a self-sensing method which can provide the gap displacement between electrodes and suspended object without external sensors. Moreover a simple on-off controller is presented for stabilization. Experimental validation of the proposed scheme has been performed through the successful levitation of a 4-inch silicon wafer.

  • PDF

A Study on the Unique point about the Tracking at Electrical fire spot (화재현장에서 분석 절차에 따른 전기화재 조사기법 개발)

  • Kim, Dong-Ook;Lee, Ki-Yeon;Gil, Hyung-Jun;Kim, Hyang-Kon;Chung, Young-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2130-2131
    • /
    • 2011
  • Electric fire breaks out by various causes such as electric short, overload(over current), leakage current, poor contact, static electricity, insulation deterioration, partial disconnection and etc. In this paper, we studied analysis technique for scientific and systematic judgment for distinction of electricity fire existence and nonexistence, and described about electricity fire cause analysis process for collecting physical evidences. We handled external form analysis, Substance extension analysis, X-ray transmission analysis, cross-section analysis, thermal analysis, chemical structure analysis, surface structure analysis, component analysis, electrical properties analysis, and circuit analysis by analysis technique for electricity fire cause judgment. We expect that analysis technic elevation and correct cause of fire analysis of scene of a fire investigators and analysts through this paper which see help.

  • PDF

Power Supply System with Real-time Posture Sensing Capability for Mobile Robot (이동로봇의 실시간 자세 감지 기능을 갖는 전력공급 시스템)

  • Jin Sang-Yun;Yi Soo-Yeong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.12 no.3
    • /
    • pp.289-293
    • /
    • 2006
  • In this paper, we developed a ground power supply system for a mobile robot moving in the constrained region. By using an external scan circuit through the electrodes, it is also possible to detect the absolute position and heading angle of the robot without any additional position sensors. Since the heavy weighted-battery for electric power and the expensive absolute position sensors are not necessary to the robot by using for proposed system, the mobile robot system becomes cost-effective and dynamically fast.

Three-phase Motor Drive IC for Automotive Applications (자동차용 3상 모터 드라이브 IC)

  • Jung, Jin-Soo;Park, Shi-Hong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.7
    • /
    • pp.563-566
    • /
    • 2009
  • This paper presents a motor drive IC for automotive applications. The drive IC is dedicated to control and drive external MOSFETs which directly drive 3-phase motor with a high current. In case of driving high-side power switches, the bootstrap topology is widely used. however, it requires three bootstrap diode and three capacitor respectively. And it needs a minimum charging time to maintain high-side voltage. The motor drive IC uses a charge-pump circuit for all three high-side voltage with various protection schemes for automotive applications.

A Study on Converter Circuit Analysis Using GTO Device Modeling (GTO DEVICE의 MODELING에 의한 변환 회로 해석)

  • Seo, Young-Soo;Sung, Dae-Yong;Cho, Moon-Taek;Lee, Sang-Bong
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.1016-1018
    • /
    • 1992
  • A numerical model of a three junction device is presented. It allows the simulation of the external characteristics of the PNPN family devices and in this work the simulation of gate turn-off thyristor(GTO) is particularly considered. The proposed PNPN device simulation model solves all the drawbacks presented by the previous work, simulates the GTO well, and fulfills.

  • PDF

A Case Study of between Pipe Deformation-Compaction Ratio using Flexible Sewer Pipe (하수도용 연성관의 다짐정도에 따른 관거의 거동에 대한 사례연구)

  • Kim, Young-Jin;Lee, Soo-Heon;Ahn, Chang-Keun;Oh, Jin-Ki
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.1012-1017
    • /
    • 2010
  • Sewer Pipes are not being managed for twenty years after laying. So, The life span of sewer pipes is on the decrease. For solve the life span decrease of sewer pipes, correct checking of questions and measure preparation are necessary through investigation in sewer pipes. This research investigated on the state of sewer pipes in the housing and industrial sites through CCTV(closed-circuit television) and device of digitalized strain investigation. And, a result is as follows. A results of PE, PVC, GRP, CSP investigations were found of pipe-transformation state by earth pressure and external load.

  • PDF

A Driving Method for Large-Size AMOLED Displays Using a-Si:H TFTs

  • Min, Ung-Gyu;In, Hai-Jung;Kwon, Oh-Kyong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.517-520
    • /
    • 2008
  • A voltage-programming pixel circuit, which compensates the threshold voltage shift of TFTs and the degradation of OLED, is proposed for large sized a-Si:H active matrix organic light emitting diode (AMOLED) applications. Considering threshold voltage variation (or shift), OLED degradation and reverse bias annealing, HSPICE simulation results indicate that luminance error of every gray level is less than 0.4 LSB under the condition of +1V threshold voltage shift and from -0.2 LSB to 2.6 LSB within 30% degradation of OLED in the case of 40-inch full HDTV condition.

  • PDF