• Title/Summary/Keyword: external chamber

Search Result 154, Processing Time 0.028 seconds

THE EFFECT OF HEMOSTATIC SOLUTIONS ON DENTIN PERMEABILITY (치과용 지혈제가 상아질 투과도에 미치는 영향)

  • Kim, Chong-Hyun;Shim, June-Sung;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.4
    • /
    • pp.472-483
    • /
    • 2000
  • Before impression making in the fixed restorations or other prosthesis, hemostatic solutions are used for hemostasis and moisture control. Hemostatic solutions effectively control bleeding but their major ingredients, acid removes smear layers which are formed in the tooth preparation, exposes the dentinal tubular orifices which are occluded by smear layers, makes dentinal tubular fluid displace more easily to the various external stimulus, and according to the hydrodynamic theory, consequently causes dentin hypersensitivity. To know the effect of hemostatic solutions on dentin permeability, coronal dentin discs, 1mm in thickness, were prepared from extracted third molars free from decay and wear, and a split chamber device was used. Hydraulic conductance values and SEMs, which were measured before and after treatment with $Astringedentr^{(R)},\;Altract^(R)\;and\;Epri-dent^{(R)}$, were compared and ana-lysed. The following conclusions were drawn: 1. Hydraulic conductance values which were measured after the treatment of hemostatic solutions were increased in all groups(p<0.05). 2. %change values of hydraulic conductance were compared but no significant difference was found among the three hemostatic solutions(p<0.05). 3. On SEM observations of all groups, after treatment smear layers were removed and dentinal tubular orifices were partially exposed. On the basis of these conclusions, the reckless use of hemostatic solutions should be restricted, and when in use, various methods should be considered to protect dentin.

  • PDF

Fabrication and Characterization of TFT Gas Sensor with ZnO Nanorods Grown by Hydrothermal Synthesis (수열합성법으로 성장시킨 ZnO 나노 로드기반 TFT 가스 센서 제조 및 특성평가)

  • Jeong, Jun-Kyo;Yun, Ho-Jin;Yang, Seung-Dong;Park, Jeong-Hyun;Kim, Hyo-Jin;Lee, Ga-Won
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.4
    • /
    • pp.229-234
    • /
    • 2017
  • In this study, we fabricated a TFT gas sensor with ZnO nanorods grown by hydrothermal synthesis. The suggested devices were compared with the conventional ZnO film-type TFTs in terms of the gas-response properties and the electrical transfer characteristics. The ZnO seed layer is formed by atomic-layer deposition (ALD), and the precursors for the nanorods are zinc nitrate hexahydrate ($Zn(NO_3)_2{\cdot}6H_2O$) and hexamethylenetetramine ($(CH_2)6N_4$). When 15 ppm of NO gas was supplied in a gas chamber at $150^{\circ}C$ to analyze the sensing capability of the suggested devices, the sensitivity (S) was 4.5, showing that the nanorod-type devices respond sensitively to the external environment. These results can be explained by X-ray photoelectron spectroscopy (XPS) analysis, which showed that the oxygen deficiency of ZnO nanorods is higher than that of ZnO film, and confirms that the ZnO nanorod-type TFTs are advantageous for the fabrication of high-performance gas sensors.

The Susceptibility of Electronic Circuits inside the Cavity by HPEM(High Power Electromagnetics) Environment (금속 함체내부로 입사되는 고출력 전자기 펄스에 대한 전자회로의 민감성 분석)

  • Hwang, Sunl-Mook;Kwon, Hae-Ok;Huh, Chang-Su;Choi, Jin-Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.12
    • /
    • pp.1892-1897
    • /
    • 2012
  • Modern electronic circuits are of importance for the function of communication, traffic systems and security systems. An intentional threat to these systems could be of big casualties and economic disasters. This study has examined susceptibility of electronic circuits inside the cavity by HPEM(High Power Electromagnetics). The UWB measurements were done at an anechoic chamber using a RADAN voltage source, which can generate a transient impulse of about 200 kV. The HPEM wave penetrated inside the metal case appeared to the long damped ringwave of pulse length compared with the incident wave. In addition, the resonant frequency generated inside the metal case occurred primarily in the range of 1~3 GHz. The frequency band of 1~3 GHz was influenced on the electronic circuit, which was confirmed by an external antenna and an internal absorber. The electronic circuit was influenced by HPEM infiltrated into the cavity at the 86 kV/m out of the metal cases. Also in case of an absorber the susceptibility of an electronic circuit was smallest among other cases(aperture, antenna). It is considered that absorber has a function absorbing electromagnetic wave infiltrated into the cavity and simultaneously limiting resonance by varying a boundary condition inside the cavity. Based on the results, electronic equipment systems could be applied to protection that has suited system requirements.

A Study on Analyzing Bottlenecks of Logistics in Incheon Port;Focused on Container Freight (인천항 물류애로요인 분석에 관한 연구;컨테이너 화물을 중심으로)

  • An, U-Cheol;An, Seung-Beom
    • Proceedings of the Korea Port Economic Association Conference
    • /
    • 2006.08a
    • /
    • pp.159-179
    • /
    • 2006
  • As the current trend to the main index of the port competitiveness evaluation, the competitiveness index of the port service comes to more important than the part of expense, location and facility. To reform the bottleneck of port has an effect on improving port service competitiveness. Therefore, this study shows the importance of analyzing bottlenecks on logistics to improve port competitiveness. It collected recent questionnaire data which are the subject as the Custom Service, the Chamber of Commerce and Industry, the Trade Association about bottlenecks of port logistics for working out bottlenecks of domestic port logistics and it produced the order of priorities of bottlenecks by multiplying each output priorities and weights of each process in user of Incheon inner-outer port which is focused on container freight by analysis of priority and Analytic Hierarchy Process(AHP). Unlike existing studies, this study has important values. It presents the priority evaluation only focused on the container freight was produced by port users who are categorized into shipping company, terminal operation company and forwarder, car-ferry in Incheon inner-outer port and making a application of logistics process. It means internal and external competitiveness improvement plan can be presented more concretely and detailed than past competitiveness attributes such as location, facility, service and expense. If the analysis of port logistics bottlenecks which was focused on container freight is extended to the part of general cargo and sundries such as haul grain, car, scrap iron, those studies will be able to provide Incheon port users with useful information and a model of analyzing overall bottleneck of logistics in Incheon port.

  • PDF

A Case of Mitochondrial Respiratory Chain Defect with Progressive Bilateral Cararacts (진행성 양측 백내장이 동반된 미토콘드리아 질환 1례)

  • Lee, Soonie;Lee, Young-Mock
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.18 no.3
    • /
    • pp.95-98
    • /
    • 2018
  • A striking feature of mitochondrial disorders is the vast heterogeneity in their clinical symptoms that ranges from a single organ to severe multisystem involvement. Though a variety of ocular symptoms such as ptosis, pigmentary retinal degeneration, external ophthalmoplegia, and optic nerve atrophy can occur in association with mitochondrial cytopathies, progressive bilateral cataracts are rare among their ocular findings. A 5-year-old girl with no previous medical history came to our hospital presenting symptoms of seizure. She started showing progressive developmental regression, increased seizure frequency, hypotonia, general weakness, dysphagia and decreased vision. Lactic acidosis was noted in metabolic screening test and we confirmed mitochondrial respiratory chain complex I defect in spectrophotometric enzyme assay using the muscle tissue. Progressive bilateral cataracts then developed and were fully evident at the age of 7. She underwent cataract extraction with posterior chamber lens implantation. We are reporting a case of mitochondrial respiratory chain defect with multiorgan involvements including bilateral progressive cataract, an uncommon ocular manifestation. Ophthalmologic evaluation is highly recommended not to overlook the possible ocular manifestations in mitochondrial disorders.

  • PDF

Selection of Optimum Clearance Considering the Dynamic Behavior of a High-pressure Injector (고압 인젝터의 동적 거동을 고려한 최적 틈새 조합에 관한 연구)

  • Ryu, Daewon;Kim, Dongjun;Park, Sang-Shin;Ryu, Bongwoo
    • Tribology and Lubricants
    • /
    • v.37 no.5
    • /
    • pp.172-178
    • /
    • 2021
  • An injector is a mechanical device present inside the engine. Its main function is to supply an appropriate volume of fuel into the combustion chamber, which is directly related to the overall engine efficiency of a car. During the operation of an injector, a magnetic force lifts the parts of the injector from closed position to open position which generates a horizontal force on the needle. The horizontal force acts on a different position from that of the center of mass of the needle. Therefore, this causes eccentricity in the needle and the generation of a tilting motion during the lifting operation which can result in wear. However, appropriate selection of clearances for these parts can prevent wear. In this study, lubrication analysis is conducted to determine the optimum clearance of parts with sliding motion inside the injector. The height functions are derived considering the dynamic behavior and relative velocity of the parts. Using the derived height function, the pressure profiles are calculated for the lubricated surfaces from the Reynolds' equation. Subsequently, the fluid reaction forces are calculated. The equations of motions are applied to the fluid reaction forces and external forces are solved to calculate the minimum film thickness between each part with variation in the clearances. Finally, the optimum clearances are determined. The effect of the clearances on the behavior of the moving parts is presented and discussed.

Adsorption Properties of Paint Mixed with Powdered Activated Carbon According to the Number of Coatings (분말활성탄을 혼합한 도료의 도장횟수에 따른 흡착 특성)

  • Choi, Byung-Cheol;Kyoung, In-Soo;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.25-26
    • /
    • 2021
  • Due to COVID-19, the spread of non-face-to-face culture is increasing the time spent indoors. Accordingly, it is necessary to reduce indoor air pollutants. Also, among building materials, there are paints. As the number of coatings increases, the coating film becomes thick, and there is a risk of cracking and falling off. Therefore, this study is to examine the adsorption properties of indoor air pollutants according to the number of coatings of a paint mixed with powdered activated carbon. In the experimental plan, the addition ratio of powdered activated carbon was selected as 30%, and the number of coatings was selected as primcoating, second coat, and finishing coat, and the concentration of formaldehyde and volatile organic compounds were measured. As a result, as the number of coatings increased, the concentration of formaldehyde and volatile organic compounds tended to decrease. This is considered to be due to the fact that not only the physical adsorption acted by the internal pores of the powdered activated carbon, but also because a lot of powdered activated carbon was present on the painted surface as the coating film was formed. However, since it is judged that there is an error in the concentration due to the inflow of external air as the chamber cover is opened to put the test object in the adsorption test process, it is considered that the experimental method needs to be supplemented.

  • PDF

Morphology and Histology of the Olfactory Organ in the Korean Endemic Species, Pseudobagrus koreanus (Cypriniformes, Cyprinidae) (한국 고유종 눈동자개 Pseudobagrus koreanus 후각기관의 형태 및 조직학적 특성 연구)

  • Kim, Hyun-Tae;Chae, Dong-Hyun
    • Korean Journal of Ichthyology
    • /
    • v.34 no.3
    • /
    • pp.153-159
    • /
    • 2022
  • The olfactory organ of a Korean endemic species, Pseudobagrus koreanus, was investigated to describe its morphology and histology and analyze correlation between habitat environment and its ecological habits and characters, using a stereo microscope, a light microscope, and a scanning electron microscope. Its external morphology showed tubular anterior nostril at the tip of the snout and slit posterior nostril at the base of the nasal barbel. The olfactory chamber showed the rosette structure consisting of numerous lamellae radial and parallel to the medium raphe. The olfactory lamella has the sensory epithelium with olfactory receptor nuerons, supporting cells, basal cells, lymphatic cells, plasma cells and the non-sensory epithelium with stratified epithelial cells, mucous cells, lymphatic cells. In particular, 1) 41~43 (n=20) lamellae, 2) lymphatic cells and plasma cells, 3) mucous cells including neutral polysaccharid may be olfactory characteristics relevant to a stagnant or a standing habitat environment, nocturnal habit dependent on olfaction, and taxonomic characters compared at least to other catfish species.

ANTIMICROBIAL EFFECT OF ANTIBIOTICS AND ROOT CANAL CEMENTS ON THE PREDOMINANT PATHOGENIC ANAEROBIC MICROFLORA IN ROOT CANALS (근관내 주요 혐기성 병인균에 대한 수종 항생제와 근관충전용 세멘트의 항균효과에 관한 연구)

  • Bae, Kwang-Shik
    • Restorative Dentistry and Endodontics
    • /
    • v.18 no.2
    • /
    • pp.515-525
    • /
    • 1993
  • The purpose of this study was to evaluate the susceptibility of anaerobic microorganisms to certain antibiotics and root canal cements. Prevotella intermedia(Bacteroides intermedius) ATCC 25611(serotype A), Fusobacterium nucleatum ATCC 25586, Actinomyces viscosus ATCC 15987 which are the predominant pathogenic anaerobes in dental root canals were cultured in BHI for 48 hours(Fig.1). After each $200{\mu}l$ of those broths with microorganisms was streaked on each surface of blood agar plate, 2 to 5 antibiotic discs which are impregnated with Tetrncycline, Erythromycin, Ampicillin, Clindamycin, or Vancomycin were applied on each surface of blood agar plate and cultured for 5 days anaerobically in the anaerobic chamber (Fig.2). 15 antibiotic discs for each kind of antibiotics and each species of microorganisms were tested. Also each kind of root canal cement tubes which include Zinc oxide eugenol cement, Zinc phosphate cement, Calcium hydroxide powder+DD.W., Calcium hydroxide paste(Pulpdent Tempcanal), or Vitapex(Table 1) were applied on the inoculated BAPs after $200{\mu}l$ of each experimental species of microorganisms was streaked on the surface of blood agar plates, and they were cultured for 5 days anaerobically in the anaerobic chamber(Fig.3). The sensitivity(antimicrobial effect) was determined by the diameter of the inhibition zone. The results are as follows: 1. The results of antibiotic susceptibility test(Table 2) 1) All of the tested antibiotics had antimicrobial activity with various degrees. 2) In Prevotella intermedia (old Bacteroides intermedius), the diameter of inhibition zone to Erythromycin($37.87mm{\pm}2.20$) was largest, those to Tetracycline($26.20mm{\pm}2.96$), Vancomycin($21.53mm{\pm}1.96$), Clindamycin($18.73mm{\pm}0.96$) was smaller than former orderly, and That to Ampicillin ($7.87mm{\pm}0.83$) was smallest. 3) In Actinomyces viscosus, the diameter of inhibition zone to Erythromycin($28.73mm{\pm}1.22$) was largest, those to Ampicillin($21.73mm{\pm}1.03$), Clindamycin($21.33mm{\pm}1.59$) was similarly next order, that to Vancomycin($19.00mm{\pm}1.96$) was smaller than Clindamycin, and that to Tetracycline($11.93mm{\pm}0.70$) was smallest. 4) In Fusobacterium nucleatum, the diameter of inhibition zone to Ampicillin($31.07mm{\pm}1.91$) was largest, that to Erythromycin($28.87mm{\pm}0.92$), Clindamycin($20.47mm{\pm}1.51$), Vancomycin ($16.73mm{\pm}0.96$), Tetracycline ($12.13mm{\pm}1.06$) are smaller than former orderly. 2. The results of root canal cements and pastes(Table 3) 1) The external diameter of tube is 4mm, so 4mm of the inhibition zone diameter means non-susceptable. Prevotella intermedia (old Bacteroides intermedius) was non-susceptable to Calcium hydroxide powder+D.D.W., Calcium hydroxide paste(pulpdent Tempcanal), and Actinomyces viscosus was non-susceptable to Zinc phosphate cement, Calcium hydroxide powder + D.D.W., Calcium hydroxide paste(pulpdent Tempcanal). 2) In Prevotella intermedia (old Bacteroides intermedius), the diameter of inhibition zone to Zinc oxide eugenol cement($13.67mm{\pm}3.30$) was largest, that to Vitapex($9.20mm{\pm}2.96$), Zinc phosphate cement($6.13mm{\pm}2.07$) was smaller than former. 3) In Actinomyces viscosus, the diameter of inhibition zone to Zinc oxide eugenol cement($17.40mm{\pm}5.20$) was largest and that to Vitapex($8.80mm{\pm}1.70$) was next order. 4) In Fusobacterium nucleatum, the diameter of inhibition zone to Vitapex($42.33mm{\pm}17.2$) was largest and those to Calcium hydroxide paste(Pulpdent Tempcanal)($14.47mm{\pm}3.72$) and Zinc oxide eugenol cement($8.93mm{\pm}2.71$), Zinc phosphate cement($8.20mm{\pm}2.27$), Calcium hydroxide powder+D.D.W.($5.53mm{\pm}2.10$)was next orderly. And then In Zinc oxide eugenol cement and Zinc phosphate cement group, two of fifteen samples showed no inhibition zone, in Calcium hydroxide powder + D.D.W. group, 8 of 15 samples showed no inhibition zone.

  • PDF

Dosimetric effects of couch attenuation and air gaps on prone breast radiation therapy (Prone Breast Phantom을 이용한 couch 산란영향 평가)

  • Kim, Min Seok;Jeon, Soo Dong;Bae, Sun Myeong;Baek, Geum Mun;Song, Heung Gwon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.43-51
    • /
    • 2017
  • Purpose: The purpose of this study is to evaluate the dosimetric effects of couch attenuation and air gaps using 3D phantom for prone breast radiation therapy. Materials and method: A 3D printer(Builder Extreme 1000) and computed tomography (CT) images of a breast cancer patient were used to manufacture the customized breast phantom. Eclipse External Beam Planning 13.6 (Varian Medical Systems Palo Alto, CA, USA) was used to create the treatment plan with a dose of 200 cGy per fraction with 6 MV energy. The Optically Stimulated Luminescence Detector(OSLD) was used to measure the skin dose at four points (Med 1, Med 2, Lat 1, Lat 2) on the 3D phantom and ion-chamber (FC65-G) were used to perform the in-vivo dosimetry at the two points (Anterior, Posterior). The Skin dose and in-vivo dosimetry were measured with reference air gap (3 cm) and increased air gaps (1, 2, 3, 4, 5, 6 cm) from reference distance between the couch and 3D phantom. Results: As a result, measurement for the skin dose at lateral point showed a similar value within ${\pm}4%$ compared to the plan. While the air gap increased, skin dose at medial 1 was reduced. And it was also reduced over 7 % when the air gap was more than 3 cm compared to radiation therapy plan. At medial 2 it was reduced over 4 % as well. The changes of dose from variety of the air gap showed similar value within ${\pm}1%$ at posterior. As the air gap was increased, the dose at anterior was also increased and it was increased by 1 % from the air gap distance more than 3 cm. Conclusion: Dosimetrical measurement using 3D phantom is very useful to evaluate the dosimetric effects of couch attenuation and air gaps for prone breast radiation therapy. And it is possible to reduce the skin dose and increase the accuracy of the radiation dose delivery by appling the optimized air gap.

  • PDF