• Title/Summary/Keyword: exposure test

Search Result 1,935, Processing Time 0.033 seconds

Evaluation of Self-cleaning Property by Measuring Brightness of Tio2 Coating Ceramic Tile under Outdoor Exposure Test (옥외폭로시험 Tio2 코팅 세라믹 타일의 명도측정에 의한 방오특성 평가)

  • Shin, Dae-Yong;Kim, Kyung-Nam
    • Journal of the Korean Ceramic Society
    • /
    • v.45 no.6
    • /
    • pp.345-349
    • /
    • 2008
  • $TiO_2$ coating ceramic tile for self-cleaning purpose was prepared by the precipitant dropping method using $TiCl_4$ as a precursor. $TiO_2$ film was formed on the ceramic tile by spray-coating technique and heat-treated at $500^{\circ}C$ for 1 h. The size and crystalline structure of $TiO_2$ particles were 15.3 nm and anatase phase. The outdoor exposure tests were conducted and the effects of outdoor exposure test conditions, such as exhaust concentration of contamination materials (test places), the UV light intensity (irradiation direction) and coating amounts of $TiO_2$ on the self-cleaning properties were investigated by the brightness measurements. As a results, self-cleaning property of $TiO_2$ coating tile was affected by the coating amount of $TiO_2$ however, not affected by the UV light intensity included in sun's ray (irradiation direction). $TiO_2$ coating ceramic tile can be utilized for exterior finishing materials because of self-cleaning property of $TiO_2$ coating tile.

Urinary Metabolites and Neurobehavioral Test on Styrene Exposure Workers (일부 스티렌 폭로 근로자의 뇨중 대사산물과 신경행동학적 검사)

  • Lee, Chang-Hee;Moon, Deog-Hwan;Lee, Hun;Park, Jun-Han;Kim, Dae-Hwan;Lee, Jong-Tae;Chun, Jin-Ho;Kim, Hwi-Dong;Lee, Chae-Un
    • Journal of Preventive Medicine and Public Health
    • /
    • v.29 no.4 s.55
    • /
    • pp.863-875
    • /
    • 1996
  • In order to prepare the fundamental data for the health promotion by assessing the exposure level of styrene, the author determined the concentration of mandelic acid and phenylglyoxylic acid in urine of 42 workers who were exposed to styrene by high performance liquid chromatography and surveyed 16 symptoms, by questionnaire and also tested neurobehavioral test(digit symbol, benton visual retention) in 2 FRP plants of Kyung Nam area from July to September, 1995. Control was sampled by age sex matching method. The concentration of styrene in air was determined by gas chromatography. The results were as follows; 1. Geometric mean concentration of styrene in air was 17.4ppm, geometric mean concentration of mandelic acid(MA) in urine were 404.3mg/g creatinine for exposure group, 46.4mg/g creatinine for control group, geometric mean concentration of phenylglyoxylic acid(PGA) in urine were 57.5mg/g creatinine for exposure group, 9.5mg/g creatinine for control group. Mean concentration of MA and PGA showed statistically significant difference between exposure group and control group(p<0.01). 2. Number of symptom were 2.9 for exposure group, 3.3 for control group, number of digit symbol were 24.1 for exposure group, 32.5 for control group, number of Benton visual retention test were 6.1 for exposure group, 6.0 for control group, respectively. As result of adjusting the education year, number of Benton visual retention test showed statistically significant difference between exposure group and control group(p<0.05). 3. Excellent correlation were observed between environmental styrene exposure and urinary MA(r=0.80), PGA(r=0.73), and MA+PGA(r=0.81).

  • PDF

A Study on the Performance Evaluation of Repair Material and Method for Reinforced Concrete Structure by tong Term Exposure Experiment (장기폭로실험에 의한 철근콘크리트 구조물 보수재료 · 공법의 성능평가에 관한 연구)

  • Kim Moo-Han;Kim Yong-Ro;Kim Jae-Hwan;Ho Jang-Jong;Cho Bong-Suk
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.5 s.83
    • /
    • pp.659-666
    • /
    • 2004
  • In this study, for the establishment of the performance evaluation methods and the quality control standard of durability recovery method, the quantitative exposure data by long term exposure test under the coast and air environment is accumulated and analyzed. Investigating and evaluating the result of exposure test during 18 months of exposure age under the coastal and normal atmosphere environment, micro crack, swelling and spatting of surface coating material crack of repair standards of repair material and method through continuous exposure test in the future.

Performance Evaluation of Repair Material and Method for Reinforced Concrete Structure by Long Term Exposure Experiment (장기폭로실험에 의한 철근콘크리트 구조물의 보수재료.공법 성능평가)

  • Kim, Moo-Han;Kim, Gyu-Yong;Cho, Bong-Suk;Kim, Young-Duck;Kim, Young-Sun
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.1
    • /
    • pp.39-46
    • /
    • 2007
  • In this study, for the establishment of the performance evaluation methods and the quality control standards of durability recovery method, the quantitative exposure data by long term exposure test under the coast and normal atmosphere is accumulated and analyzed. Investigating and evaluating the result of exposure test during 30 months of exposure age under the coastal and normal atmosphere environment, carbonation depth and chloride-ion penetration depth very little penetrated than cover depth. It seems reasonable to conclude that main cause of Corrosion of reinforcing bar are chloride-ion and macro cell from the result of corrosion area and corrosion velocity. Therefore, it is considered to be applied as the fundamental data on the performance evaluation and quality control standards of repair material and method through continuous exposure test in the future.

An ability test for the use of indirect radiographic unit (간접촬영용 X-선 발생장치 성능 평가)

  • Im, In-Cheol
    • Journal of radiological science and technology
    • /
    • v.27 no.4
    • /
    • pp.37-41
    • /
    • 2004
  • Purpose : Raise ability cultivation in presence at a sicked business by performance management estimation of device through measurement. Also Learn a technology that measure exact tube voltage, exposure time, output dose. And it is to grasp photofluorography X-ray generator existing circumstances using at hospital. Material & Method : Investigated Photofluorography X-ray generator(inside, outside each 10) of 10 university hospitals using tube voltage, exposure time, output dose measuring instrument. Result : Photofluorography device that tube voltage correctness is incongruent by examination PAE decision came out 3, and at exposure time correctness examination 2 incongruent, Also 3 that calculate coefficient of variation about exposure in repeatability examination of exposure were incongruent. Inappropriate photofluorography device is 5 outside hospital(mobile unit) and the thing in hospital was 3 in 3 kind of efficiency test. It appeared high that photofluorography device outside hospital is more incongruent than thing in hospital. Conclusion : May ready situation that can offer patient medical service of good quality by radiation exposure reduction, image quality administration, retake decrease etc. by keeping performance of Photofluorography device. Therefore, is considered that need on-time efficiency test.

  • PDF

Investigation of Standard Evaluation for the Quality Control of General X-ray Systems

  • Kang, Byung-Sam;Son, Jin-Hyun;Kim, Byoung-Jun;Park, Deok-Woo;Jung, Byoung-Hoon;Lee, Hyo-Jin;Hong, Ji-Young;Kim, Seung-Chul
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.2
    • /
    • pp.71-79
    • /
    • 2010
  • Thanks to the great development of technology in radiation, we are now able to reduce radiation exposure to the patients, and the radiographer and expenses in medical sector. We are also trying to produce ideal images which maintain useful information. These kinds of effort are increasing over the world. For that reason, we should get images which include necessary data of patients. Then it also can help to reduce radiation exposure to the patients. Therefore, we need to know the problems that cause a falling off in image's quality and check on generator in case of their electronic and mechanical errors. And moreover, we should anticipate the possibility of devices errors and prevent them with regular quality control. This investigation was conducted in medical institutions, institute of educations and hospitals. They are all in Seongnam-City. We used PMX-III, kVp meter to implement kVp test, mR / mAs output test, light fiel / beam alignment test, Reproducibility of exposure dose, half value layer test, reproducibility of exposure time test. in the case of hospitals, they perceive the importance of regular quality control and organize the regular quality control team so they can be satisfied with the error standard in most experiments. On the other hand, when it comes to medical institutions and institute of educations, they perceive the importance of regular quality control less than hospitals do. Radiographer need to understand the importance of regular quality control and practice it so they can get the fine ideal image with the lower dose to the patient.

  • PDF

Factors associated with Behaviors that Reduce Exposure to Environmental Hormones among Nursing Students (환경호르몬 저감행동 영향요인)

  • Lee, Jungsuk;Bea, Hanju;Kim, HyeJin
    • Korean Journal of Occupational Health Nursing
    • /
    • v.28 no.4
    • /
    • pp.285-292
    • /
    • 2019
  • Purpose: This study aimed to examine the factors associated with behavior that reduces exposure to environmental hormones among nursing students. Methods: Data were collected from 160 nursing students in D and B cities, using self-report questionnaires. Data were analyzed using SPSS 22.0, and the analyses included descriptive statistics, t-test, ANOVA, Pearson's correlation coefficient test, and stepwise multiple regression. Results: Behavior that reduces exposure to environmental hormones differed significantly in terms of the participants' knowledge about environmental hormones. Behavior that reduces exposure to environmental hormones was negatively correlated with knowledge of environmental hormones, attitude towards pro-environmental behavior, and environmental self-efficacy; these factors were significant predictors of behavior that reduces exposure to environmental hormones, and accounted for 27.0% of the variance. Conclusion: Environmental self-efficacy was identified as the most significant factor affecting behavior that reduces exposure to environmental hormones in nursing students. Therefore, it is necessary to develop programs to improve pro-environmental behavior and environmental self-efficacy in nursing students.

The Status of Blood and Body Fluid Exposure and Affecting Factors among Nursing Students including Knowledge, Performance regarding Standard Precautions (간호대학생의 임상실습중 혈액 및 체액 노출현황과 영향 요인 - 감염관리 지식 및 수행도 중심으로-)

  • Kim, Hee-Jung;Kim, Nam-Cho
    • The Journal of Korean Society for School & Community Health Education
    • /
    • v.15 no.3
    • /
    • pp.17-30
    • /
    • 2014
  • Objectives: The purpose of this study was to investigate the status of exposure to blood and body fluid and factors affecting on blood and body fluid exposure of nursing students including knowledge, performance regarding standard precautions. Methods: 280 nursing students in D-city and S-city participated in this study. Data collection was conducted from January to March 2012. Students' knowledge and performance on standard precautions of infection control in hospitals were measured using the measurement developed by Hong(2010). Data analysis was performed using descriptive statistics, t-test, one way-ANOVA, ${\chi}^2-test$, Pearson correlation coeficient, logistic regression by the SPSS WIN 18.0 program. Results: 58.6 percent of subjects experienced a exposure to blood and body fluid. The level of nursing students' knowledge level regarding standard precautions was $22.44{\pm}2.11$ and performance level was $4.31{\pm}0.50$. The factors affecting on blood and body fluid exposure of nursing students were knowledge level and education type about infection control. Conclusions: Based on the findings of this study, to decrease the exposure to blood and body fluid of nursing students, a proper education need to be stressed to improve nursing students' infection control knowledge and awareness.

  • PDF

Study on the Maintenance of Gloss and Durability test of Glossing Exposure Concrete (광택노출콘크리트의 광택유지성 및 내구성 평가)

  • Ha, Jae-Dam;Kim, Ki-Soo;Choi, Long;Chung, Tai-Wung;Lee, Hyun-Hee;Shin, Sung-Woo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.147-150
    • /
    • 1999
  • Glossing Exposure Concrete is a high quality architectural concrete, i.e., appearance of natural stone and a marbling effect concrete to achieve high quality glassy reflective surface for outer wall of the building. In this study to obtain the conservation and durability of gloss of the "glossing exposure concrete" we developed a from practice and the best mix proportion and derived the optimistic removal time of form to bring out the durable glassy reflective surface and durable concrete. Hereby with the "glossing exposure concrete" obtained, we investigate the accelerate carbonation and accelerate durability test to evaluate the durability factor of this type of concrete.is type of concrete.

  • PDF

Formaldehyde 가스 흡입에 의한 마우스의 급성독성 및 소핵 유발성에 관한 연구

  • Kim, Choong-Yong;Kim, Kyun;Shim, Jeom-Soon;Kim, Yong-Hwa;Roh, Jung-Koo
    • Toxicological Research
    • /
    • v.7 no.1
    • /
    • pp.61-71
    • /
    • 1991
  • The acute and genetic effect of formaldehyde on mice through inhalation route was studied. The Riley's chamber with one stack of cage was used for the exposure and the micronucleus test was performed under unprecedently maximum exposure concentration. LC50's of formaldehyde in mice by whole body exposure for 4 hours were 105.5 ppm with 95% confidence interval of 72.6 ppm and 143.2 ppm for male, and 159.2 ppm with 95% confidence interval of 116.5 ppm and 272.7 ppm for female. Cinicial symptoms by acute exposure were salivation, lacrimation, and abnormal respiration.

  • PDF