• 제목/요약/키워드: exposure test

검색결과 1,933건 처리시간 0.026초

Differences by Selection Method for Exposure Factor Input Distribution for Use in Probabilistic Consumer Exposure Assessment

  • Kang, Sohyun;Kim, Jinho;Lim, Miyoung;Lee, Kiyoung
    • 한국환경보건학회지
    • /
    • 제48권5호
    • /
    • pp.266-271
    • /
    • 2022
  • Background: The selection of distributions of input parameters is an important component in probabilistic exposure assessment. Goodness-of-fit (GOF) methods are used to determine the distribution of exposure factors. However, there are no clear guidelines for choosing an appropriate GOF method. Objectives: The outcomes of probabilistic consumer exposure assessment were compared by using five different GOF methods for the selection of input distributions: chi-squared test, Kolmogorov-Smirnov test (K-S), Anderson-Darling test (A-D), Akaike information criterion (AIC) and Bayesian information criterion (BIC). Methods: Individual exposures were estimated based on product usage factor combinations from 10,000 respondents. The distribution of individual exposure was considered as the true value of population exposures. Results: Among the five GOF methods, probabilistic exposure distributions using the A-D and K-S methods were similar to individual exposure estimations. Comparing the 95th percentiles of the probabilistic distributions and the individual estimations for 10 CPs, there were 0.73 to 1.92 times differences for the A-D method, and 0.73 to 1.60 times differences (excluding tire-shine spray) for the K-S method. Conclusions: There were significant differences in exposure assessment results among the selection of the GOF methods. Therefore, the GOF methods for probabilistic consumer exposure assessment should be carefully selected.

태백지역 석탄광산의 작업부서별 호흡성 분진 폭로농도 (Respirable Cool Dust Exposure Concentration at Work Sites of Underground Coal Mines in Taebaek Area)

  • 윤영노;정호근
    • 한국산업보건학회지
    • /
    • 제1권1호
    • /
    • pp.47-55
    • /
    • 1991
  • Exposure level of respirable coal dust of underground coal mines in Taebaek area was evaluated. Personal air samplers with 10-mm nylone cyclones were attached to the coal workers including drillers, coal cutters, their assistants, haulers, and separators. Log-normality of respirable dust exposure concentration were tested by Kolmogorov-Smirnov one-sample test. Differences of means of respirable dust exposure concentration between work sites were tested by one-way ANOVA test and multiple comparison(Scheffe) test. And differences of respirable dust exposure concentration of principal and assistant workers in drilling sites and in coal faces were tested by paired t-test. Relation of respirable dust exposure concentration for the principal workers and their assistants in drilling sites and in coal faces were tested by regression analysis. The results were as follows : 1. All of the respirable dust concentration were log-normally distributed. 2. There were not only significantly different means of exposure concentration between drillers and coal cutters but between coal cutters and haulers. 3. Means of exposure concentration of drillers and drilling assistants were not significantly different. And means of exposure concentration of coal cutters and coal cutting assistants were not different.

  • PDF

모의 실험주택 모니터링 결과를 활용한 실내공기 및 바닥먼지 중 Di(2-ethyl-hexyl) phthalate (DEHP)의 이론적 총량 비율 산출 (Calculation of the Theoretical Total Amount Ratio of Di(2-ethyl-hexyl) Phthalate in Indoor Air and Floor Dust in a Test House)

  • 천사호;이가원;김승중;정승표;강다영;김기태
    • 한국환경보건학회지
    • /
    • 제49권6호
    • /
    • pp.324-333
    • /
    • 2023
  • Background: Human exposure to phthalates in indoor environments occurs via dermal absorption, oral ingestion of indoor dust, and inhalation of indoor air. However, systematic studies to investigate the exposure rate to phthalates among the three exposure routes in indoor environments are currently limited. Objectives: A theoretical exposure ratio between inhalation and oral exposure was calculated based on the total amount of di(2-ethyl-hexyl) phthalate (DEHP) emitted into indoor air and deposited into floor dust in a test house. Methods: Flooring and wallpaper containing DEHP were installed in a test house and the concentration of DEHP in both indoor air and floor dust were monitored for five months. Based on the measured DEHP concentrations, the theoretical total amount ratio of DEHP that could be exposed through inhalation and oral ingestion was calculated. Results: Considering the period of operation in the test house, the theoretical total amount of DEHP through inhalation and oral ingestion exposures in the entire test house space was calculated to be 0.014 mg and 5.5 mg, respectively. The exposure ratio of the two routes between inhalation and oral exposure corresponding to the total DEHP amount in flooring and wallpaper was 6.0×10-7% and 2.3×10-4%, indicating that theoretical oral exposure to DEHP is approximately 380 times higher than inhalation. Conclusions: Monitoring results from a test house has shown that oral exposure is the main exposure route for DEHP in indoor environments. The experimental design employed in this study and theoretical exposure ratio obtained can be applied to investigate actual exposure to DEHP and to determine the exposure characteristics of various types of semi-volatile organic compounds.

수영 시험 모델에서 산소 농도에 따른 운동성 변화와 독성 평가 (Oxygen Toxicity: Behavioral Assessment by Swim Test in Mouse Exposed to Hypoxia and Hyperoxia)

  • 김동희;강문철;김재일;이근호;김광열;김형건
    • Toxicological Research
    • /
    • 제19권2호
    • /
    • pp.99-104
    • /
    • 2003
  • This study was aimed to evaluate the effect of oxygen on motor activity and toxicity in male mice. The modified Porsolt forced swim test (FST) was used and the distance and time of movement by mice were analyzed in 15。C water bath for 20 minutes using the automatic Ethovision videotracking system. Analyses were carried out before and after 20 minutes of exposure to 10%-70% concentration of normobaric oxygen. The effects of inspired oxygen tension on the distance and time of movement showed the similar trends, but changes in distance were more prominent. Both the distance and time of movement increased after exposure to 30% and 40% oxygen concentration. The distance and time of movement also increased upon exposure to 50% and 60% oxygen. In contrast, increases En movement and time under exposure to 21% oxygen concentration were suppressed when exposed to over 50% oxygen concentration. With exposure to 10% oxygen, there was a significant decrease in the distance of movement and a slight suppression of movement time. During the swim test, 12.5%, 37.5%, and 87.5% of the mice drowned after exposure to 10%, 60%, and 70% oxygen concentration, respectively. These results suggest that motor activity can be enhanced by inspired oxygen up to 40% concentration. When hypoxic and hyperoxic oxygen exposure over 50%, motor activity is reduced and toxicity may be induced.

VISUALIZATION OF THE INTERNAL WATER DISTRIBUTION AT PEMFC USING NEUTRON IMAGING TECHNOLOGY: FEASIBILITY TEST AT HANARO

  • Kim Tae-Joo;Jung Yong-Mi;Kim Moo-Hwan;Sim Cheul-Muu;Lee Seung-Wook;Jeon Jin-Soo
    • Nuclear Engineering and Technology
    • /
    • 제38권5호
    • /
    • pp.449-454
    • /
    • 2006
  • Neutron imaging technique was used to investigate the water distribution and movement in Polymer Electrolyte Membrane Fuel Cell (PEMFC) at HANARO, KAERI. The Feasibility tests were performed in the first and second exposure rooms at the neutron radiography facility (NRF) at HANARO in order to check the ability of each exposure room, respectively. The feasibility test apparatus was composed of water and pressurized air before making up the actual test apparatus. Due to the low neutron intensity in the second exposure room, the exposure time was too long to investigate the transient phenomena of PEMFC. Although the exposure time was improved to 0.1 sec in the first exposure room, it was difficult to discriminate detail water movement at the channel due to the high noise level. Therefore, the experimental setup must be optimized according to the test conditions. Water discharge characteristics were investigated under different flow field geometries by using feasibility test apparatus and the neutron imaging technique. The water discharge characteristics of a 3-parallel serpentine are superior to those of a 1-parallel serpentine, but water at Membrane Electrode Assembly (MEA) was not removed, regardless of the flow field type.

혈중수은 노출에 따른 일부 초등학생의 건강영향에 관한 연구 (Health Effects of Mercury Exposure on Some School Children in Korea)

  • 김대선;김근배;강택신;이종화;남상훈
    • 한국환경보건학회지
    • /
    • 제33권5호
    • /
    • pp.345-352
    • /
    • 2007
  • As mercury absorbed into body can cross the blood-brain barrier and react with DNA and RNA. Central nervous system has been known to be affected especially in children. But it was very difficult to know the influences of chronic low-does Hg exposure on the health. Although many studies investigated the affect, most of results were still disparate. In order to investigate the health effects of mercury exposure, several test were conducted for some Korean school children. The general health effects were investigated using blood test, Posturography and computer-based neurobehavioral test was done to examine the affect of Hg into neural responses. About 400 children were chosen for blood test whose blood Hg level were upper and lower 10% of population participated in the nationwide Hg exposure survey. The concentration of calcium and creatine, the number of white and red blood cell showed statistical significance with Hg exposure in blood test. Another 36 children were selected from the same participants for the posturography and neurobehavioral test. The intensity and center frequency of hand tremor which were related to unconsciousness also showed distinct significances. Any general relations with Hg exposure were not found in all test including computer-based neurobehavioral test.

염해 및 복합열화에 의한 부식촉진시험과 장기폭로 시험의 상관성에 관한 연구 (Study on the correlation between long-term exposure tests and accelerated corrosion tests by the combined damage of salts)

  • 박상순;이민우
    • Corrosion Science and Technology
    • /
    • 제13권6호
    • /
    • pp.214-223
    • /
    • 2014
  • Interest in the durability assessment and structural performance has increased according to an increase of concrete structures in salt damage environment recent years. Reliable way ensuring the most accelerated corrosion test is a method of performing the rebar corrosion monitoring as exposed directly to the marine test site exposure. However, long-term exposure test has a disadvantage because of a long period of time. Therefore, many studies on reinforced concrete in salt damage environments have been developed as alternatives to replace this. However, accelerated corrosion test is appropriate to evaluate the critical chlorine concentration in the short term, but only accelerated test method, is not easy to get correct answer. Accuracy of correlation acceleration test depends on the period of the degree of exposure environments. Therefore, in this study, depending on the concrete mix material, by the test was performed on the basis of the composite degradation of the salt damage, and investigate the difference of corrosion initiation time of the rebar, and indoor corrosion time of the structure, of the marine environment of the actual environments were inuestigated. The correlation coefficient was derived in the experiment. Long-term exposure test was actually conducted in consideration of the exposure conditions submerged zone, splash zone and tidal zone. The accelerated corrosion tests were carried out by immersion conditions, and by the combined deterioration due to the carbonation and accelerated corrosion due to wet and dry condition.

Derivation of External Exposure Characteristics of Industrial Radiography Based on Empirical Evidence

  • Cho, Junik;Kim, Euidam;Kwon, Tae-Eun;Chung, Yoonsun
    • Journal of Radiation Protection and Research
    • /
    • 제47권2호
    • /
    • pp.93-98
    • /
    • 2022
  • Background: This study aims to derive the characteristics of each work type for industrial radiography based on empirical evidence through expert advice and a survey of radiation workers of various types of industrial radiography. Materials and Methods: According to a Korean report, work types of industrial radiography are classified into indoor tests, underground pipe tests, tests in a shielded room (radiographic testing [RT] room test), outdoor field tests, and outdoor large structure tests. For each work type, exposure geometry and radiation sources were mainly identified through the expert advice and workers' survey as reliable empirical evidence. Results and Discussion: The expert advice and survey results were consistent as the proportion of the work types were high in the order of RT room test, outdoor large structure test, underground pipe test, outdoor field test, and indoor test. The outdoor large structure test is the highest exposure risk work type in the industrial radiography. In most types of industrial radiography, radiation workers generally used 192Ir as the main source. In the results of the survey, the portion of sources was high in the order of 192Ir, X-ray generator, 60Co, and 75Se. As the exposure geometry, the antero-posterior geometry is dominant, and the rotational and isotropic geometry should be also considered with the work type. Conclusion: In this study, through expert advice and a survey, the external exposure characteristics for each work type of industrial radiography workers were derived. This information will be used in the reconstruction of organ dose for health effects assessment of Korean radiation workers.

Oxytetracycline의 단기 노출이 제브라피쉬의 행동 및 내분비 반응에 미치는 영향 (Effects of the Acute Exposure Oxytetracycline on the Behavior and Endocrine Response in Adult Zebrafish)

  • 고은성;이승헌
    • 생명과학회지
    • /
    • 제25권2호
    • /
    • pp.151-157
    • /
    • 2015
  • Zebrafish는 약리학 연구에 널리 사용되는 실험 동물 중 하나이다. Oxytetracycline은 넓은 항균 범위를 가지는 항생제로써 단백질 합성을 억제하여 정균 작용을 가진 항생제이다. 본 연구의 목적은 OTC에 노출이 되었을 때 zebrafish에게서 나타나는 행동변화와 내분비계의 변화를 관찰하였다. OTC (50, 100 or 200 mg/l)에 노출된 zebrafish의 행동변화를 확인하기 위해 novel tank test와 open field test를 진행하였다. 또한 내분비계의 변화를 확인하기 위하여 whole-body cortisol의 수치를 cortisol kit를 이용하여 측정하였다. Novel tank test 결과 상층부에서 머문 시간과 부동 시간에서 OTC를 약욕하였을 때 통계적으로 유의성이 있는 증가현상이 확인되었다. 반면에, 총 이동거리, 과행동 시간, 유영 속도 그리고 상하 변위에서 OTC를 약욕하였을 때 통계적으로 유의성 있는 감소 현상이 확인되었다. Open field test 결과 부동시간에서 OTC를 약욕 하였을 때 통계적으로 유의성 있는 증가 현상이 확인 되었다. 그러나 OTC를 약욕 하였을 때 총 이동거리, 움직인 시간, 유영 속도에서 통계적으로 유의성이 있는 감소 현상이 확인 되었다. Whole-body cortisol에서는 zebrafish에게 약욕을 하였을 때 증가하는 경향이 관찰되었다. 이러한 결과를 통하여 OTC가 zebrafish에게 화학적 스트레스로 작용한 것으로 사료된다.

폴리머시멘트계 단면복구재의 내구성 및 철근부식특성에 관한 실험적 연구 (An Experimental Study on the Durability and Reinforcement Corrosion of Polymer Cement Based Repair Material)

  • 김영선;김영덕;나철성;조봉석;김규용;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.487-490
    • /
    • 2005
  • In this study, for the establishment of the performance evaluation methods and the quality control standards of durability recovery method, the data of indoor durability test and the data of the long term exposure test under the coast are accumulated and analyzed. As a result of the indoor test, durability of repair material was more superior to that of plain concrete, but as a result of investigating and evaluating exposure test at 30 month of exposure age under the coastal environment, the difference in electric potential and the reinforcement corrosion at place replaced with repair material are found.

  • PDF