• Title/Summary/Keyword: exposure curve

Search Result 221, Processing Time 0.024 seconds

Electro-Optic Characteristics on Photoaligned TN cell using Photopolymer Based Hydroxy Aromatic Polyimide (Hydroxy Aromatic Polyimide계 광폴리머 표면을 이용한 광배향 TN 셀의 전기광학 특성)

  • Lee, Whee-Won;Hwang, Jeoung-Yeon;Choi, Sung-Ho;Kang, Hyung-Ku;Bae, Yu-Han;Lee, Myun-Gil;Suh, Dong-Hack;Seo, Dae-Shik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.185-188
    • /
    • 2005
  • We synthesized the two types of photoalignment material of high thermal resistance with hydroxyl aromatic polyimide, and studied the liquid crystal (LC) aligning capabilities on the photopolymer layers. Also, electro-optical (EO) performances for the twisted-nematic (TN)-liquid crystal display (LCD) photoaligned with linearly polarized UV exposure were investigated. A good LC alignment with UV exposure on the two types of photopolymer surface can be obtained. The Voltage-transmittance (V-T) curve in the photoaligned TN cell with UV exposure was different from two type. The response time of photoaligned TN cell was measured about 21 ms in two alkyl chain and about 15ms in four alkyl chain.

  • PDF

Hypoxic exposure can improve blood glycemic control in high-fat diet-induced obese mice.

  • Park, Yeram;Jang, Inkwon;Park, Hun-Young;Kim, Jisu;Lim, Kiwon
    • Korean Journal of Exercise Nutrition
    • /
    • v.24 no.1
    • /
    • pp.19-23
    • /
    • 2020
  • [Purpose] Blood glucose and insulin resistance were lower following hypoxic exposure in previous studies. However, the effect of hypoxia as therapy in obese model has not been unknown. [Methods] Six-week-old mice were randomly divided into chow diet (n=10) and high-fat diet (HFD) groups (n=20). The chow diet group received a non-purified commercial diet (65 % carbohydrate, 21 % protein, and 14 % fat) and water ad libitum. The HFD group was fed an HFD (Research Diet, #D12492; 60% kcal from fat, 5.24 kcal/g). Both groups consumed their respective diet for 7 weeks. Subsequently, HFD-induced mice (12-weeks-old) were randomly divided into two treatment groups : HFD-Normoxia (HFD; n=10) and HFD-Hypoxia (HYP; n=10, fraction of inspired=14.6%). After treatment for 4 weeks, serum glucose, insulin and oral glucose tolerance tests (OGTT) were performed. [Results] Homeostatic model assessment values for insulin resistance (HOMA-IR) of the HYP group tended to be lower than the HFD group. Regarding the OGTT, the area under the curve was 13% lower for the HYP group than the HFD group. [Conclusion] Insulin resistance tended to be lower and glucose uptake capacity was significantly augmented under hypoxia. From a clinical perspective, exposure to hypoxia may be a practical method of treating obesity.

A Study on Dose Calculation in Intracavitary Radiotherapy of the Carcinoma of the Uterine Cervix with TAO Applicator (TAO Applicator를 이용한 자궁경암 강내조사시의 선양계산에 관한 고찰)

  • Kim, Chul-Soo;Kim, Jung-Jin
    • Radiation Oncology Journal
    • /
    • v.2 no.1
    • /
    • pp.101-106
    • /
    • 1984
  • Various methods are available for determination of exposure time in intracavitary radiotherapy of the carcinoma of the uterine cervix. To determine the accuracy of dose calculation with isodose curve for TAO applicator, comparison with results calculated by computer for radiotherapy treatment Planning was done in 24 procedures done in 12 consecutive patients with the carcinoma of the uterine cervix from May to December, 1983. The results are as follows: 1. The average dose rate Per hour of Point A was 87.70 rad, being 89.91 rad ana 85.49 rad in left and right, respectively. 2. The average percentage of dose rate of point A calculated by isodose curve method over that by computer was $101.28\%$ and the difference was less than $5\%$ in 17 Procedures and over $10\%$ in only 3 procedures. 3. The average percentage in case of point B was $108.67\%$. In conclusion, in most cases the difference was less than 200 rad for point A and less than 100 rad for point B during 2 courses of intracavitary radiotherapy. And so the dose rate calculation with isodose curve for TAO applicator is comparatively accurate.

  • PDF

The evaluation on the biological safety of diagnostic ultrasound using radiation-induced apoptosis in the external granular layer of mouse cerebellum (마우스 소뇌과립층의 apoptosis를 지표로 한 진단용 초음파의 안전성 검증)

  • Oh, Heon;Lee, Song-eun;Yang, Jung-ah;Jo, Sung-kee;Chung, Chi-young;Son, Chang-ho;Kim, Sung-ho
    • Korean Journal of Veterinary Research
    • /
    • v.39 no.3
    • /
    • pp.628-634
    • /
    • 1999
  • We have studied, by a nonisotopic in situ end-labeling(ISEL) technique, frequency of apoptosis in the external granular layer(EGL) of the cerebellum of immature mice by ${\gamma}$-rays irradiation from $^{60}Co$ or diagnostic ultrasound exposure. The total number of normal cells and cells showing morphological features of apoptosis were counted. The frequency of apoptotic cells was expressed as a percentage of the total number of cells in EGL. The extent of changes following 200 cGy(1090 cGy/min) was studied at 2, 4, 6, 8, 12, or 24 hours after exposure. The maximal frequency was found 6~8 hours after exposure. The immature mice that received 18, 36, 54, 108, 198, 396 cGy of ${\gamma}$-rays or diagnostic ultrasound(7.5MHz, 4.2mW, $I_{SPTA}=7.9mW/cm^2$, $I_{SPTA}=114.3W/cm^2$) for 10 or 30 minutes were examined 6 hours after irradiation. Measurements performed after ${\gamma}$-ray irradiation showed a dose-related increase in apoptotic cells in each of the mice studied. The dose-response curves were analyzed by a linear-quadratic model ; frequency of apoptotic cell in the EGL was y = $(0.1349{\pm}0.01175)D$+$(-0.0001522{\pm}0.0000334)D^2$+0.048($r^2$ = 0.981, D = dose in cGy). In the experiment of ultrasound exposure, the frequency of apoptotic cell was $0.106{\pm}0.130$(10 minutes exposure) and $0.167{\pm}0.220$(30 minutes exposure). We estimated the relative dose of the yield from the experiment with ultrasound by substituting the yield from ultrasound exposure into the curve from the ${\gamma}$-irradiation. The relative dose of ultrasound exposure compared with ${\gamma}$-irradiation were 0.432 cGy(10 minutes exposure) and 0.885 cGy(30 minutes exposure). We have found that there is no evidence to indicate that diagnostic ultrasound involves a significant risk.

  • PDF

Analysis on the relation between electric current and magnetic field near transmission lines (송전선로에서 전류와 자계의 상관관계 분석)

  • Cho, Sung-Bae;Lee, Eun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.3-5
    • /
    • 1997
  • The relation between electric current and magnetic field under three overhead transmission lines being operated was studied. It was examined for a difference each other in comparison with calculated value and measured value for current, magnetic field. With magnetic field equations made out, The magnetic field distribution around transmission lines had made to figure out with easy by load electric current value. Additionally, we are going to describe the distribution curve of magnetic exposure volume for KEPCO's T/L.

  • PDF

Evaluation of Image Quality and Stability of Radiation Output according to Change in Tube Voltage and Sensitivity when Abdomen and Pelvis Examination of Digital Radiography (DR) (디지털 방사선 시스템(DR)의 복부와 골반부 검사 시 관전압과 감도 변화에 따른 영상 화질과 방사선 출력의 안정성 평가)

  • Hwang, Jun-Ho;Yang, Hyung-Jin;Choi, Ji-An;Lee, Kyung-Bae
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.12
    • /
    • pp.517-526
    • /
    • 2019
  • The purpose of this study is to find the optimal method for clinical application by analyzing image quality and radiation output according to parameter combination when using the Automatic Exposure Control (AEC). The experimental method combines 70, 81 kVp with sensitivity S200, S400, S800 and S1000 of the Automatic Exposure Control for Entrance Surface Dose (ESD), current volume, Signal to Noise Ratio (SNR), Contrast to Noise Ratio (CNR), Time-to-Radiation Dose Curve in abdomen and pelvis. And then, image quality and radiation output stability were evaluated. As a results, Entrance Surface Dose, current volume, Signal to Noise Ratio, Contrast to Noise Ratio decreased as the tube voltage and sensitivity were set higher. In addition, the higher tube voltage and sensitivity, the Time-to-Radiation Dose Curve showed a poor output stability. In conclusion, the higher the combination of tube voltage and sensitivity in the use of Automatic Exposure Control, the more problems can be seen in image quality and stability of the radiation output. Therefore, a relatively low combination of tube voltage and sensitivity showed that the image quality and radiation output stability could be optimized by minimizing the error range that would occur when the detector recognized a combination of parameters.

Performance Based Evaluation of Concrete Chloride Diffusion Resistance from Wind Speed-Sunlight Exposure Time Curing Conditions of Climate Change (기후변화에 대한 풍속과 일조시간의 콘크리트 염화물확산 저항성의 성능중심평가)

  • Kim, Tae-Kyun;Cho, Chul-Min;Choi, Ji-Hun;Kim, Jang-Ho Jay
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.5
    • /
    • pp.601-609
    • /
    • 2016
  • Recently, extreme climate change has been occurring globally not only in the simple form of temperature increases but also in a wide range of extreme climatic events, such as abnormal drought conditions and frequent typhoons. In addition, climate change is delaying the construction period of concrete structures, increasing related economic losses. Forcing construction projects for completion without considering climate change is leading to concrete quality deterioration, poor quality constructions, and consequent casualties and property damage. Therefore, to address these problems and provide a countermeasure to climate change, the present study selected wind speed, and sunlight exposure time as the most important curing conditions among the climate factors affecting concrete structures and examined their effects on the curing and durability of concrete structures. In addition, for the analysis of the experimental results, this study proposed a process of performance based evaluation (PBE) of concrete strength and durability using a method of Satisfaction Curve (SC) generation.

Studies on the Light Fastness of Dyeings (3) Effect of Dye Concentration on the Visual Judgement of Fading (染色物의 日光에 對한 堅牢性에 關한 硏究 (第3報) 染料初濃度가 視覺에 依한 褪色判定結果에 미치는 影響)

  • Ha Wan Shik
    • Journal of the Korean Chemical Society
    • /
    • v.11 no.1
    • /
    • pp.12-16
    • /
    • 1967
  • Fading of Chlorantine Fast Red 5B (C.I. Direct Red 81) on cotton fabric exposed to carbon are light was examined. It was observed that the dye had anomaly in CF curve slope, while normal in CFG one. Auther considered that the reason for discrepancy of the one with the other curve slope might be appeared from Weber-Fechner law, and derived following equation $F_v=[logC_0-log(C_0-C_0F_t/100)]{\times}100/(logC_0+b)$ where $F_t$; the proportion of dye faded after t hour exposure. $F_v$; the proportion of dye faded after t hour exposure, when a pattern is judged by visual method $C_0$; initial dye concentration. b; constant. also, the reason for increasing lightfastness with dye concentration was discussed on view of the above equation.

  • PDF

Vertical alignment of liquid crystal on $a-SiO_x$film by using $Ar^+$ beam

  • Son, Phil-Kook;Park, Jeung-Hun;Cha, Sung-Su;Kim, Jae-Chang;Yoon, Tae-Hoon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.818-821
    • /
    • 2006
  • We demonstrate the vertical alignment of liquid crystal on $a-SiO_x$ film surface using the ion beam exposure. Liquid crystal can be aligned vertically by the rotational oblique evaporation of $a-SiO_x$ film. However, the electro-optic switching behavior of liquid crystal along random directions results in disclination lines. We found that we can achieve highly uniform alignment of liquid crystal without disclination lines by using the ion beam exposure. We found from XRD and XPS data that the vertical alignment can be achieved when x approaches 1.5 at the $a-SiO_x$ film surface. We have shown that the pretilt angle can be controlled by changing ion beam parameters, such as the ion beam energy, the angle of incidence, and the exposure time. We found that whether liquid crystals can be aligned vertically or homogeneously on $a-SiO_x$ film can be predicted simply by measuring the change in optical transmittance by deposition of $a-SiO_x$ thin film layers. We also have shown that a liquid crystal cell aligned vertically by the ion beam exposure exhibits the voltage-transmittance curve similar to that of a rubbed polyimide cell.

  • PDF

An Electrochemical Evaluation on the Corrosion Resistance of a Al Alloy (주조용 Al합금의 내식성에 관한 전기화학적 평가)

  • Youn Dae-Hyun;Lee Myung-Hoon;Kim Ki-Joon;Moon Kyung-Man
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.5
    • /
    • pp.495-501
    • /
    • 2005
  • Al is a active metal that owes its resistance to a thin, protective, barrier oxide surface layer, which is stable in air and neutral aqueous solution. Thus Al alloys are widely used in architectural trim. cold & hot-water storage vessels and piping. However Al and most of its alloy may corrode with some forms such as pitting corrosion, intergranular corrosion and galvanic corrosion in the case of exposure to various industrial and marine atmosphere. Therefore a correct evaluation of corrosion resistance for their Al and Al alloys may be more important in a economical point of view. In this study. a relative evaluation of corrosion resistance for three kinds of Al alloys such as ALDC2, ALDC3, and ALDC8 series was carried out with electrochemical method. There is a tendency that corrosion potential is shifted to positive or negative direction by alloying components regardless of corrosion resistance. Moreover the data of corrosion properties obtained from cathodic Polarization curve, cyclic voltammogram and AC. DC impedance respectively showed a good correspondence each other against the corrosion resistance but variation of corrosion potential. passivity current density of anodic polarization curve and corrosion current density by Tafel extrapolation and Stern-Geary method didn't correspond with not only each other but also considerably the data of corrosion properties discussed above. Therefore it is suggested that an optimum electrochemical evaluation for corrosion resistance of Al alloy is to calculate the diffusion limiting current density of cathodic polarization curve, impedance of AC or DC and polarization resistance of cyclic voltammogram.