1 |
S. C. Kim, H. K. Lee, Y. S. Lee, and J. H. Cho, "Evaluation of Automatic Exposure Control System Chamber for the Dose Optimization when Examining Pelvic in Digital Radiography," J. of X-ray Science and Technology, Vol.23, No.3, pp.321-330, 2015.
DOI
|
2 |
B. Louise, F. Ronan, C. Conor, G. Aoife, D. Mark, G. Dermot, O. Geraldine, and D. Anita, "Doses under Automatic Exposure Control (AEC) for Direct Digital Radiographic (DDR) X-ray Systems," Radiation Protection Dosimetry, Vol.147, No.1/2, pp.210-214, 2011.
DOI
|
3 |
M. Reade, S. Cournane, J. McCavana, and J. Lucey, "Modeling CTDlvol through Analysis of the Localiser Image: Towards Estimating Factors Influencing Automatic Exposure Control Tube Output," Physica Medica : Eur. J. of Med. Phys., Vol.52, pp.172-172, 2018.
|
4 |
ICRP, ICRP Publication 135, 2017.
|
5 |
ICRP, ICRP Publication 93, 2004.
|
6 |
ICRP, ICRP Publication 105, 2007.
|
7 |
S. J. Shepard, J. Wang, M. Flynn, E. Gingold, L. Goldman, K. Krugh, D. L. Leong, E. Mah, K. Ogden, D. Peck, E. Samei and C. E. Willis, Report of AAPM Task Group 116, AAPM, 2009.
|
8 |
R. G. Lane, D. M. Stevens, J. P. Gibbons, L. J. Verhey, K. R. Hogstrom, E. L. Chaney, M. C. Martin, E. E. Klein, K. P. Doppke, B. R. Paliwal. R. E. Wendt III, and M. G. Herman, Report of AAPM Task Group 90, AAPM, 2006.
|
9 |
J. K. Dave, A. K. Jones, R. Fisher, K. Hulme, L. Rill, D. Zamora, A. Woodward, S. Brady, R. D. MacDougall, L. Goldman, S. Lang, D. Peck, B. Apgar, S. J. Shepard, R. Uzenoff, and C. Willis, "Current State of Practice Regarding Digital Radiography Exposure Indicators and Deviation Indices: Report of AAPM Imaging Physics Committee Task Group 232," Med. Phys., Vol.45, No.11, pp.e1146-e1160, 2018.
|
10 |
R. K. Grewal, N. Young, L. Colins, N. Karunnaratne, and N. Sabharwal, "Digital Chest Radiography Image Quality Assessment with Dose Reduction," Australasian Physical & Engineering Sciences in Medicine, Vol.35, No.1, pp.71-80, 2012.
DOI
|
11 |
G. Dougherty, Digital Image Processing for Medical Applications, Cambridge, 2009.
|
12 |
G. Dougherty, Pattern Recognition and Classification, Springer Science & Business Media, 2012.
|
13 |
최지안, 황준호, 이경배, "인터벤션에서 자동노출제어 장치 이용 시 내장형 면적 선량계와 이동형 면적 선량계의 면적선량 비교를 통한 선량계 오차분석과 교정지침 필요성 연구," 한국콘텐츠학회논문지, 제18권, 제3호, pp.508-515, 2018.
|
14 |
IEC, IEC 61267 : Medical Diagnostic X-ray Equipment - Radiation Conditions for Use in the Determination of Characteristics, 2005.
|
15 |
IEC, IEC 62220-1 : Medical Electrical Equipment - Characteristics of Digital X-ray Imaging Devices - Part 1: Determinations of the Detective Quantum Efficiency, 2003.
|
16 |
IEC, IEC 62494-1 : Medical Electrical Equipment - Exposure Index of Digital X-ray Imaging Systems - Part 1: Definitions and Requirements for General Radiography, 2008.
|
17 |
ISO, ISO 9236-1 : Photography - Sensitometry of Screen/Film Systems for Medical Radiography - Part 1: Determination of Sensitometric Curve Shape, Speed and Average Gradient, 2004.
|
18 |
E. B. Podgorsak, Radiation Physics for Medical Physicists, Springer, 2016.
|
19 |
G. Li, T. C. Greene, T. K. Nishino, and C. E. Willis, "Evaluation of Cassette-based Digital Radiography Detectors using Standardized Image Quality Metrics: AAPM TG-150 Draft Image Detector Tests," J. of Applied Clinical Medical Physics, Vol.17, No.5, pp.391-417, 2016.
DOI
|
20 |
D. S. Kim and E. Kim, "Noise Power Spectrum of the Fixed Pattern Noise in Digital Radiography Detectors : Noise Power Spectrum of the Fixed Pattern Noise," Med. Phys., Vol.43, No.6, pp.2765-2773, 2016.
DOI
|
21 |
보건복지부, 진단용 방사선 발생장치의 안전관리에 관한 규칙, 2015.
|
22 |
N. W. Marshall, C. V. Ongeval, and H. Bosmans, "Performance Evaluation of a Retrofit Digital Detector-based Mammography System," Physica Medica : Eur. J. of Med. Phys., Vol.32, No.2, pp.312-322, 2016.
DOI
|
23 |
김상현, "디지털 흉부단층합성검사에서 감도와 관전압 변화에 따른 영상 최적화," 한국방사선학회 논문지, 제12권, 제4호, pp.541-547, 2018.
|
24 |
J. T. Smith, A. J. Couture, J. R. Stowell, and D. R. Allee, "Optically Seamless Flexible Electronic Tiles for Ultra Large-Area Digital X-ray Imaging," IEEE Transaction on Components, Packaging, and Manufacturing Technology, Vol.4, No.6, pp.1109-1115, 2014.
DOI
|
25 |
황준호, 이경배, "DR (Digital Radiography)에서 자동노출제어장치의 감도변화에 따른 검출기 성능평가시 흡수선량과 히스토그램을 통한 정량적 분석방법에 관한 연구," 한국콘텐츠학회논문지, 제18권, 제1호, pp.232-240, 2018.
DOI
|
26 |
https://www.iba-dosimetry.com, 2019.06.03.
|
27 |
식품의약품안전처, 영상의학 검사(일반촬영)에서의 표준 촬영기법, 2014.
|