• 제목/요약/키워드: experimental results

검색결과 64,148건 처리시간 0.071초

성견의 열개형 골 결손부에서 PDGF-BB와 IGF-l 치주조직 치유에 미치는 영향 (THE EFFECTS OF PLATELET DERIVED GROWTH FACTOR-BB AND INSULIN-LIKE GROWTH FACTOR-I ON THE REGENERATION OF PERIODONTIUM IN THE DEHISCENCE DEFECTS OF DOGS)

  • 손효상;조규성
    • Journal of Periodontal and Implant Science
    • /
    • 제26권4호
    • /
    • pp.799-821
    • /
    • 1996
  • The ultimate goal of periodontal treatment has been to facilitate regeneration of diseased periodontal tissues, destroyed by inflammatory periodontal disease. For regeneration of the periodontium to occur, all of component tissues must be restored to their original position and architecture. Growth factors which were known to promote the cellular processes, ie, proliferation, migration and matrix synthesis, have been in the spotlight of current periodontics. Platelet-derived growth factor(PDGF) stimulates collagen and non collagen protein synthesis, migration and proliferation of periodontal ligament cells. Insulin-like growth factor(IGF) has potentials to induce collagen and bone matrix synthesis so that it regulates normal bone remodeling. Application of the combination have been known to facilitate formation of bone and cementum, and to synergistically interact to promote coronal migration and proliferation of periodontal ligament cells. These two growth factors have been reported to exhibit positive effect in the periodontally diseased teeth or class m furcation defects. The aim of the present study was to test the hypothesis that PDGF-BB alone or the combination of PDGF-BB and IGF-I can predictably enhance regeneration of the periodontium in the dehiscence defect. Following the resection of premolars, roots were embedded. After 12 weeks of healing period, standardized experimental $4{\times}4mm$ dehiscence defects were created on the mid-facial of the premolar roots in each of 4 young adult dogs. In control group, only methylcellulose gel was inserted in the defects. In experimental group I and II, gel with $2{\mu}g$ of PDGF-BB or $2{\mu}g$ of PDGF-BB and $1{\mu}g$ of IGF-I was inserted in the defects, respectively. At 8 weeks postsurgery, the dogs were sacrificed. The results were observed histologically and analyzed histomorphometrically.The results of this study were as follws. 1. The new cementum formation was $1.26{\pm}0.69mm$ in the control group, $1.80{\pm}0.84mm$ in the experimental group I, $1.93{\pm}0.51mm$ in the experimental group II. The experimental group III, the experimental group I, the control group were in the order of cementum formation without statistically significant differences between control and all experimental groups. 2. The new bone formation was $1.00{\pm}0.53mm$ in the control group, $1.53{\pm}0.63mm$ in the experimental group I, $l.33{\pm}0.45mm$ in the experimental group II. The experimental group I, the experimental group II, the control group were in the order of bone formation without statistically significant differences between control and all experimental groups. 3. The root resorption was $1.12{\pm}0.64mm$ in the control group, $1.34{\pm}0.73mm$ in the experimental group I, $0.79{\pm}0.59mm$ in the experimental group II without statistically significant differences between control and all experimental groups. These results suggested that the use of PDGF-BB alone or PDGF-BB and IGF-I in the dehiscence defects might facilitate periodontal regeneration in some degree, but has not shown statistically significant results.

  • PDF

연속누출을 가지는 액체 풀 확산 모델의 실험적 평가 (Experimentally Evaluation of a Liquid Pool Spreading Model with Continuous Release)

  • 김태훈;도규형;김명배;한용식;최병일
    • 한국수소및신에너지학회논문집
    • /
    • 제26권6호
    • /
    • pp.659-665
    • /
    • 2015
  • In this study, an experimental investigation is performed for evaluation of a liquid pool spreading model with continuous release. The model considered in this study was developed based on a concept which means that the liquid pool spreading is governed by a balance between an inertia force from gravity and a frictional force from friction with the ground under the whole base of the liquid pool. For evaluation of the model, experimental study is performed. Experimental apparatus is setup for measuring release rate, spreading velocity, and evaporation rate from a liquid pool. The experimental results are compared with results from the model. By applying release and evaporation rates obtained from experiments to solving the model, liquid pool radius variation according to time can be obtained. For evaluation of an effect of friction force in the spreading model, results obtained from the models with and without the friction force are compared with those obtained from the experiments. As a result, it is shown that there exists a large deviation between the results obtained from the model without the friction force and the experimental results. On the other hand, the tendency of liquid pool radius variation according to time is similar between the results obtained from the model without the friction force and the experimental results.

능동 클램프형 DC-DC 컨버터의 효율에 관한 연구 (A Study on Efficiency of Active Clamp Type DC-DC Converter)

  • 연제선;안태영
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.49-53
    • /
    • 2003
  • In this paper, to analyze efficiency characteristic, one of important factors in design of DC-DC converter prototype, theoretically derived power loss of individual components generating in DC-DC converter and compared theoretical results with experimental results. For evaluation of results, active clamp type Forward DC-DC converter with synchronous rectifier was composed of experimental converter. Efficiency result measured in experimental converter was compared with theoretical efficiency result derived in this paper. In comparative results, a fact that derived theoretical value and experimental value comparatively correspond have been able to verify.

  • PDF

Comparison of Monte Carlo Simulation and Fuzzy Math Computation for Validation of Summation in Quantitative Risk Assessment

  • Im, Myung-Nam;Lee, Seung-Ju
    • Food Science and Biotechnology
    • /
    • 제16권3호
    • /
    • pp.361-366
    • /
    • 2007
  • As the application of quantitative risk assessment (QRA) to food safety becomes widespread, it is now being questioned whether experimental results and simulated results coincide. Therefore, this paper comparatively analyzed experimental data and simulated data of the cross contamination, which needs summation of the simplest calculations in QRA, of chicken by Monte Carlo simulation and fuzzy math computation. In order to verify summation, the following basic operation was performed. For the experiment, thigh, breast, and a mixture of both parts were preserved for 24 hr at $20^{\circ}C$, and then the cell number of Salmonella spp. was measured. In order to examine the differences between experimental results and simulated results, we applied the descriptive statistics. The result was that mean value by fuzzy math computation was more similar to the experimental than that by Monte Carlo simulation, whereas other statistical descriptors by Monte Carlo simulation were more similar.

c-CMG Cluster for Small Satellites

  • Lee, Seung-Mok;Seo, Hyun-Ho;Rhee, Seung-Wu
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제8권1호
    • /
    • pp.105-114
    • /
    • 2007
  • This article presents the details of a designed control moment gyroscope (CMG) with a constant speed momentum wheel and one-axis-gimbal, and its experimental results performed at Korea Aerospace Research Institute. The CMG which is able to produce a torque of lOO mNm per each, is mounted in a pyramid configuration with four SGCMGs. Each CMG test and a single axis maneuver test with four-CMG cluster configuration are performed to confirm their performance on a ground-test facilities consisted of three major parts: a vibration isolation system, a dynamic force plate (Kistler sensor), and a DSP board. These facilities provide the accurate data of three axial and torques from the control moment gyro. Details of the CMG experimental results are presented with discussion of the experimental errors. The experimental data are compared with theoretical results and both results are used to verify their performance specifications.

소음인(少陰人) 가미거풍산(加味祛風散)의 효능(效能)에 관(關)한 실험적(實驗的) 연구(硏究) (Experimental Studies on the Effects of Soumin Kamikop'ungsan)

  • 황성록
    • 사상체질의학회지
    • /
    • 제2권1호
    • /
    • pp.177-188
    • /
    • 1990
  • In order to investigate experimentally the clinical effects of Soumin Kamikop'ungsan (少陰人 加味祛風散) that was prescribed to cure the Wisuhanrihanbyung (胃受寒裡寒病) of Sumin (少陰人) the author experimented various activities of mixed extract from the Sournin Kamikop'ungsan by the method prescribed in the experimental part. The results of the studies were summerized as follows: 1. Analgesic effects by acetic acid and Randall-Sellito experimental method were noted. 2. Anticonvulsive effect to strychnine was noted. 3. The sedation effects by the unbalanced effects of spontaneous momentum by wheel cage method, muscle relaxing action by Rotor rod method were noted. 4. A prolongation of anesthetic time by Thiopental-Na on the mice was noed. 5. The expansion of blood vessels by relaxation of smooth muscle was noted. According to the above results, results of Soumin Kamikop'ungsan on oriental medical references were consistent with the actual experimental results.

  • PDF

ANSYS Fluent를 이용한 와류형 분사기의 분무특성 연구 (A Study on the Spray Characteristics of Swirl Injectors Using ANSYS Fluent)

  • 윤원재;이봄;안규복
    • 한국분무공학회지
    • /
    • 제22권4호
    • /
    • pp.159-168
    • /
    • 2017
  • Numerical studies on the spray characteristics of closed-type and open-type swirl injectors were conducted using ANSYS Fluent. By changing injection pressures, discharge coefficient and spray angle were calculated using the Reynolds stress BSL turbulent model. The numerical results were compared with previous experimental data to examine their accuracy. For a closed-type swirl injector, spray angles matched well with experimental results and discharge coefficients showed approximately 8% differences. On the contrary, discharge coefficients of an open-type swirl injector were similar with experimental result but its spray angles presented around 15% differences. Though the numerical results were not perfectly consistent with experimental data, it is thought that they could be sufficiently used for analyzing spray characteristics, specially which is hard to be measured from experiments. Numerical simulation with different turbulent models was also performed to examine their effects on the numerical results.

New Experimental Investigation of Magnetic and Electric Fields in the Vicinity of High-Voltage Power Lines

  • Ghnimi, Said;Rajhi, Adnen;Gharsallah, Ali
    • Journal of Magnetics
    • /
    • 제21권1호
    • /
    • pp.102-109
    • /
    • 2016
  • In this paper, the theoretical and experimental characteristics of magnetic and electric fields in the vicinity of high voltage lines are investigated. To realize these measurements and calculations, we have developed some equations for two overhead power line configurations of 150 kV (single circuit, double circuit), based on Biot-savart law, image and Maxwell theories, in order to calculate the magnetic and electric fields. The measurements were done to a maximum distance from the tower of 50 m, at a height of 1m from the ground. These experiments take into consideration the real situations of the power lines and associated equipment. The experimental results obtained are near to that of the Biot-Savart theoretical results for a far distance from the tower; and for a distance close to the power line, the results from the image theory are in good agreement with the experimental results.

마이크로 채널 PCHE의 압력손실 특성에 관한 연구 (A Study on the Pressure Loss Characteristics of Micro-Channel PCHE)

  • 김진혁;백승환;정상권
    • 설비공학논문집
    • /
    • 제22권11호
    • /
    • pp.751-759
    • /
    • 2010
  • A newly developed type PCHE(Printed Circuit Heat Exchanger), which has a longitudinal corrugation flow channel, was fabricated using etching and diffusion bonding to evaluate its hydraulic performance. The pressure drop characteristics obtained from the experimental results are presented and the local friction factors associated with different hydraulic diameters and inclination angles are discussed. The results of a three-dimensional numerical simulation are presented, conducted using commercial CFD(Computational Fluid Dynamics) software at lower Reynolds number range. The numerical results were validated by experimental data obtained from helium gas experimental apparatus. The results of CFD prediction show fairly good agreement with the experimental data.

FRP Rods로 보강한 콘크리트 보의 전단 내하력의 평가 (Estimation of Shear Carrying Capacity on Concrete Beams, Reinforced with FRP Rods)

  • 최익창;연준희;고재용
    • 한국해양공학회지
    • /
    • 제18권1호
    • /
    • pp.63-68
    • /
    • 2004
  • The purpose of this study is to estimate the contribution of concrete and shear reinforcement, in shear carrying capacity, on concrete beams, reinforced with steel and/or FRP rods. The experimental tests for 12 concrete beams, reinforced with steel and/or FRP rods, are carried out. Experimental parameters includes the mechanical properties of reinforcements in shear and bending, and the ratio of shear reinforcement. This study compares the experimental results of shear carrying capacity in concrete beams, reinforced with steel and/or FRP rods, with the proposed equations. According to the experimental results, the effect of the concrete in concrete beams reinforced with FRP rods is decreased with decreasing Young's modulus of longitudinal tensile reinforcement. This results from the large deflection of concrete beams reinforced with decreasing Young's modulus of longitudinal tensile reinforcement. Also, the contribution of shear reinforcement is smaller than the calculated value, using the truss analogy. This results from the fact that the stress redistribution is not exhibited after the break of shear reinforcement.