• Title/Summary/Keyword: existing environment

Search Result 6,467, Processing Time 0.034 seconds

Analysis of the Change of Intensity Distribution and Luminous Environment by Reflector Shape in Indirect Reflected LED Luminaires (간접 반사형 LED 조명기구의 반사판 형태에 따른 배광형태 및 조명환경 변화 분석)

  • Kim, Yu-Sin;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.1
    • /
    • pp.9-17
    • /
    • 2011
  • Development of high efficiency and eco-friendly LED source has been progressed continuously. Also, by nation's regulations, public institutions have changed existing luminaires to LED luminaires. However, there are several differences between existing luminaires and the intensity distribution of general planar LED luminaires. In case of changing existing luminaires to LED luminaires, by such differences, there are inefficiencies both quality aspect and energy aspect in luminous environment. Therefore, this study aims to conduct a study on the changes of intensity distribution and luminous environment by reflector shapes in indirect reflected LED luminaires with software for optical design of a luminaire (Photopia 2.0) and lighting design of a space (ReluxPro). This study shows the changes of intensity distribution and luminous environment of indirect reflected LED luminaires and indirect fluorescent lamp luminaires by reflector shapes.

A study on Daylighting inducement within bedroom of Elderly care facility by light shelf attaching method for Therapeutic environment - By Dynamic Daylight Simulation Using Weather Data - (치유환경을 위한 광선반 부착방법에 따른 노인요양시설 침실 내 자연채광 유입 환경 연구 - 기상데이터 기반 동적 자연채광 시뮬레이션을 기반으로 -)

  • Cho, Ju-Young;Lee, Ki-Ho;Yun, Young-Il;Lee, Hyo-Won
    • KIEAE Journal
    • /
    • v.11 no.6
    • /
    • pp.71-79
    • /
    • 2011
  • There are high recognitions on the importance of comforts in Elderly living environment, but the circumstance is that studies on seniors facility space itself are approached only in planning level, and studies on lighting environment which is significantly associated with the comfort in the indoor environment of seniors where they actually spend the majority of their time are not that active. This study was intended to deduce cozy bedroom environment to which existing elderly care facility can be improved by using light shelf the lighting system with the advantage of being able to serve both as building sun visor and lighting window simultaneously in order to analyze the interior environment of bedroom space of elderly care facility the indoor space where the aged spend the majority of their life and examine the directions for the improvement of existing building lighting system through remodeling and renovation. In this study, lighting performance analysis was done in a way that the windows of the bedroom unit in existing facility were set in southbound direction based on two standard types and were put under initial simulation with the use of Autodesk Revit 2011, and after the simulation results were converted to Green Building Studio gbXML file to be used in ECOTECT, Daylight Autonomy a dynamic simulation and static natural lighting simulation the existing method of calculating daylight factors were deduced through Ecotect Analysis 2011. In conclusion, exiting standard model was found in such a condition that the daylight factors for both type A and type B were above 5% the proper standard value, and required improvement. In case light shelf the natural lighting system was attached, the daylight factor was improved to proper standard value for type A, and also was improved above existing facility for type B.

A Study on the Lighting Environment of Living Room and Kitchen in Apartment Houses (아파트 거실과 주방의 조명환경에 관한 연구)

  • Lim, Mann-Taek;Kwon, Chang-Yong;Kim, Hyun-Tae
    • Journal of the Korean housing association
    • /
    • v.18 no.1
    • /
    • pp.35-42
    • /
    • 2007
  • This study aims at examining the actual conditions of lighting environment and the consciousness and responses of residents with the living room of apartment house, grasping the problems of existing lighting methods, offering the lighting environment design standard in harmony with the various demands of residents, functions of living room space, life in living room and interior decoration and then pursuing the comfortable living environment. As the scope and methods of research for these, existing research methods are examined through the consideration of preceding researches and the basic outline of this research is constructed. Questionnaire survey is conducted with six apartment complexes including Kumho district, Munhung district, Sangmu district, Unnam district, Ilkok district and Chumdan district, the problems and improvements of lighting environment conditions are examined, conception and selection of lighting equipment design image are made, lighting equipment design of living room is suggested and the expected effects of lighting equipment ordering method are arranged as follows. As a result of examining and analyzing the lighting environment of living room in existing apartment houses, it is known that the conditions of existing lighting environment considered uniform lighting plan for functional sides of each room which didn't consider the various living behaviors and preference of residents and while the degree of interior decoration design is actually positive. Accordingly it seems that the lighting equipment ordering which considers the various preferences of residents is applied as the means for comfortable lighting environment, the interior environmental mood will be greatly improved.

Performance Assesment of the Existing Tunnel drain and higher permeable for the In-plane Test (평면투수 실험을 통한 기존 배수재와 고투수성 배수재의 성능 평가)

  • Ma, Sang-Joon;Lee, Heung-Soo;Choi, Hee-Sup;Kim, Kyung-Duk
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.1581-1584
    • /
    • 2008
  • In this study, performance Assesment of the existing tunnel drain and higher permeable for the In-plane Test. Two separate simulation tests from geotexitile and Lightweight Foamed Mortar compare. perfomed:the one is the in-plane test and the other is the clogging phenomenon test. As a result, NATM Composite used to Ligheweight Foamed Mortar pemability 80%, more than existing tunnel drain. Also, clogging phenomenon test do low assesment more than existing tunnel drain geotextile.

  • PDF

Assessment Items of Outdoor Environment through Analysis of SITES - Focused on the Comparison with G-SEED and LEED -

  • Lee, Hyung-Sook
    • KIEAE Journal
    • /
    • v.14 no.4
    • /
    • pp.11-18
    • /
    • 2014
  • Although assessing outdoor environment and green space in terms of sustainability and environmental performance is perceived as an important issue, most existing green building certification systems are more focused on buildings and indoor environment. Recently, the Sustainable Site Initiatives (SITES) has been developed by American Society of Landscape Architecture in order to evaluate sustainability of site development and outdoor environment. Separate from LEED, the SITES are increasingly receiving attentions as a reliable certification system in the United States. As a preliminary study to develop the items of outdoor environmental assessment, the present study is purposed to analyze the assessment items, grading system and applicability of SITES for better understanding on the system. Also it was compared to existing green building certification criteria, including G-SEED, LEED-NC, and LEED-ND in order to investigate similarities and discrepancies. The results would provide insights and basic data to improve assessment items for outdoor environment of G-SEED.

An Exploratory Study on Smart Learning Environment (스마트 러닝 환경에 관한 탐색적 연구)

  • Woo, Jin;Han, Haksoo;Lee, Sunhee
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.1
    • /
    • pp.21-31
    • /
    • 2016
  • The changes to Ubiquitous Network Environment leads existing learning environment to Smart Learning Environment. Expecially, Smart Learning Environment is in changing paradigm existing teacher centered environment and learner centered environment, recently the demand of Smart Learning Environment for learners are growing up. This study analyzed Learning Environments for Smart Learning Environment focused on the learners through analyzing Ubiquitous Network Environment that is concentrated on the physical aspects and the non-physical aspects. Also, we suggested learning several ways that can be effectively applied based on the environmental characteristics of Smart Learning.

Building a Classification Scheme of Soil and Groundwater Contamination Sources in Korea: 1. State-of-the-Art and Suggestions (토양.지하수오염원 분류체계 구축방안: 1. 국내외 현황 및 시사점)

  • An, Jeong-Yi;Shin, Kyung-Hee;Hwang, Sang-Il
    • Journal of Soil and Groundwater Environment
    • /
    • v.15 no.6
    • /
    • pp.64-71
    • /
    • 2010
  • National inventory of soil and groundwater contamination is an efficient decision-making tool to identify and manage existing or potential contaminated sources and contaminants. It has been used as basic data for establishing the scheme of regulations and remediation plans of soil and groundwater contamination in developed countries. This study examined classification of existing or potential sources of soil and groundwater contamination from various countries to suggest implications that required for development of classification of soil and groundwater contamination sources in Korea. Each country has provided a list of currently or potentially contaminating activities or landuses and identified some of the potential contaminants related to those contamination sources. Consideration of sources which had not been mentioned or regarded as contamination sources before was suggested for Korea situation. In addition, it is necessary to compile a list of existing data and information as much as possible to develop a detailed and practical list of various contamination sources.

A Study on Management Methodology of Local Government Underground Facility Database Using Mobile Mapping System I (MMS를 활용한 지자체 지하시설물 DB의 유지관리 방법론 연구 I)

  • Ryu, Ji-Ho;Yong, Min;Kim, Tai-Yohb;Lee, Hyun-Jik
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2004.04a
    • /
    • pp.353-359
    • /
    • 2004
  • Underground facility DB that is constructed by NGIS project need efficient management methodology, because falling-off in quality was worried by confused of existing management affair and management affair of computerization environment. Through analysis of existing management affair, underground facility DB and management system decide that modification/renewal factor of underground facility DB and subject affair Through modification/renewal factor of underground facility DB, developed underground facility DB management methodology using MMS. Result that apply developed management methodology to subject affair, existing affair environment improved to computerization environment and Could improve underground facilities DB authoritativeness.

  • PDF

System Implementation for PC-based Center Position Control of Strip (PC 기반 Strip 중앙 위치 제어 시스템의 구현)

  • Park, Nam-Jun;Jung, Jin-Yang;Kim, Hyun-Sool;Han, Young-Oh;Park, Sang-Hui
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.395-397
    • /
    • 1996
  • The existing CPC(Center Position Controller) has unstably performed because of dusts on reflection panel, CCD protector contamination due to high temperature in furnace or other parameters. The reason is that the existing CPC has a Z80 processor as a CPU and only performs low level image processing as a simple edge detector. So the improvement of control system through the development of robust edge detection algorithm overcoming changes of measuring environment is needed. For this, in this study we carefully analyze the image of the strip rolled in occasion that measuring environment is changing, develop the optimal edge detection algorithm to solve the problems, generate the control signal suitable for the existing CPC(Center Position Controller), and propose the capability of application to the actual environment.

  • PDF

Effect of Marine Environment and Underwater Construction on Mechanical Properties of High Strength Grout (해상환경 및 수중타설이 고강도 그라우트의 역학적 성능에 미치는 영향)

  • Kim, Beom-Hwi;Son, Da-Som;Yi, Chong-Ku
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.89-90
    • /
    • 2023
  • In this study, grout was poured into seawater to confirm the effect of similar marine environment and underwater erosion on the mechanical performance of domestically produced high-performance grout and compared with the existing strength. As a result of the compressive strength measurement, the specimen that simultaneously performed underwater drilling and seawater curing showed slow initial strength expression in both H1 and H2, and from the 7th day, it was confirmed to be within 2% of the existing intensity. It is believed that both grout were caused by disturbance with water during underwater drilling, and the same strength was subsequently shown as the existing strength.

  • PDF