• 제목/요약/키워드: exhaust system

Search Result 1,696, Processing Time 0.031 seconds

Study on Spray and Exhaust Emission Characteristics of DME-Biodiesel Blended Fuel in Compression Ignition Engine (압축착화기관에서 DME-바이오디젤 혼합연료의 분무 및 배기 특성에 관한 연구)

  • Cha, June-Pyo;Park, Su-Han;Lee, Chang-Sik;Park, Sung-Wook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.1
    • /
    • pp.67-73
    • /
    • 2011
  • The purpose of this study is to investigate experimentally the spray-atomization and combustion-emission characteristics of biodiesel-DME blended fuel. In this study, two types of test fuels pure biodiesel (BD100) and blended fuel (B-DME20) were used, and the spray and combustion characteristics of different fuel compositions were analyzed. DME constitutes 20% and biodiesel constitutes 80% (by mass fraction) of the blended fuel. The overall spray characteristics, spray tip penetration, and cone angle were evaluated using frozen spray images. In addition, the combustion and emission characteristics were analyzed on the basis of the evaluated data for a single-cylinder CI engine with common-rail injection system. It was revealed that the injection profiles of both the test fuels for a given injection pressure showed similar trends. However, the injection profiles of the blended fuel (B-DME20) indicated shorter ignition delay than those of biodiesel.

Effects of Swirl and Combustion Parameters on the Performance and Emission in a Turbocharged D.1. Diesel Engine (선회유동 및 연소인자가 터보과급 디젤엔진의 성능 및 배기가스특성에 미치는 영향)

  • 윤준규;차경옥
    • Journal of Energy Engineering
    • /
    • v.11 no.2
    • /
    • pp.90-98
    • /
    • 2002
  • The effects of swirl and combustion parameters on the performance and emission in a turbo-charged D.I. diesel engine of the displacement 9.4L were studied experimentally in this paper. Generally the swirl in the combustion process of diesel engine promotes mixing of the injection fuel and the intake air. It is a major factor to improve the engine performance because the fuel consumption and NO$_{x}$ is trade-off according to the high temperature and high pressure of combustion gas in a turbocharged D.I. diesel engine, it's necessary to thinking over the intake and exhaust system, the design of combustion bowl and so on. In order to choose a turbocharger of appropriate capacity. As a result of steady flow test, when the swirl ratio is increased, the mean flow coefficient is decreased, whereas the gulf factor is increased. Also, through engine test its can be expected to meet performance and emissions by optimizing the main parameter's; the swirl ratio is 2.43, injection timing is BTDC 13$^{\circ}$ CA, compression ratio is 16, combustion bowl is re-entrant 5$^{\circ}$, nozzle hole diameter is $\Phi$0.28*6, turbocharger is GT40 model which are compressor A/R 0.58 and turbine A/R 1.19.

An Experimental Study on $NO_x$ Reduction Efficiency and $NH_3$ Conversion Efficiency under Various Conditions of Reductant Injection on SCR and AOC (SCR 촉매와 AOC 촉매에서 환원제 분사에 따른 $NO_x$ 저감효율과 $NH_3$ 변환효율에 관한 실험적 연구)

  • Dong, Yoon-Hee;Choi, Jung-Hwang;Cho, Yong-Seok;Lee, Seang-Wock;Lee, Seong-Ho;Oh, Sang-Ki;Park, Hyun-Dae
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.18 no.5
    • /
    • pp.85-90
    • /
    • 2010
  • As the environmental regulation of vehicle emission is strengthened, investigations for $NO_x$ and PM reduction strategies are popularly conducted. Two current available technologies for continuous $NO_x$ reduction onboard diesel vehicles are Selective Catalytic Reduction (SCR) using aqueous urea and lean $NO_x$ trap (LNT) catalysts. The experiments were conducted to investigate the $NO_x$ reduction performance of SCR system which can control the ratio of $NO/NO_2$, temperature and SV(space velocity), and the model gas was used which is similar to a diesel exhaust gas. The maximum reduction efficiency is indicated when the $NO:NO_2$ ratio is 1:1 and the SV is 30,000 $h^{-1}$ in $300^{\circ}C$. Generally, ammonia slip from SCR reactors are rooted to incomplete conversion of $NH_3$ over the SCR. In this research, slip was occurred in 6cases (except low SV and $NO:NO_2$ ratio is 1:1) after SCR. Among 6 case of slip occurrence, the maximum conversion efficiency is observed when SV is 60,000 $h^{-1}$ in $400^{\circ}C$.

Evaluation of Airflow Control Capability of Natural Ventilators with Various Dampers (자연환기 벤틸레이터의 댐퍼 형태별 환기량 조절능력 평가)

  • Kim, Tae-Hyeong;Ha, Hyun-Chul;Park, Seung-Chul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.16 no.4
    • /
    • pp.364-374
    • /
    • 2006
  • Natural ventilation technique could be the substitute for or the complement to the local exhaust ventilation system in the sense of protecting work environment. Moreover, it has many strong points ; almost no mechanical parts, no energy use and no noise. If applied appropriately, it could have the very high ventilation rate and save a lot of energy expense. But, it depends on the outdoor environment, especially temperature and wind speed/direction. Predicting the capacity of natural ventilation is not an easy job because it comes from both buoyancy and wind effect. Another problem is too much flow through the ventilator especially in winter time due to too much difference between indoor and outdoor temperature. Thus some ventilators in industries are sealed by door or plastic sheet, resulting in bad work environment. Various types of dampers are used to control the flow rate through ventilators. The capabilities of flow control by damper has not been estimated. In addition, it was not tested whether the damper could obstruct the flow through ventilator when fully opened. To answer these questions, 4 types of dampers were tested by using computational fluid dynamics. 10 different configurations includes no damper, full open and half open. Flow rates were estimated and airflow fields were analysed to clarify the before-mentioned questions. The dual type damper was the best choice for controling the capability of ventilator. In addition, the upward grill type damper was the best for not obstructing the air flow when fully opened.

Experimental Study on the Spray Characteristics of a Fuel Injector for a Non-Road Small Engine (노외용 소형엔진 인젝터의 분무특성에 대한 실험적 연구)

  • Yeom, Kyoung-Min;Park, Sung-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.5
    • /
    • pp.2005-2010
    • /
    • 2011
  • Since recently exhaust gas regulation for a non-road small engine as well as commercial vehicle engine has been enforced, a carburettor of a small engine should be replaced by an electronic fuel injection system. In this study, the spray characteristics of the 400cc gasoline small engine injector has been experimentally analyzed. Based on the experimental results, suitable injector for the small engine has been selected. Through the test rig measuring spray mass distribution, fuel distribution characteristics of 3 hole- and 6 hole-injector has been analyzed. Through the visualization equipment, injector spray angle, penetration length and spray width have been measured and analyzed. Considering spray characteristics and stability, 6 hole-injector is selected for the 400cc gasoline small engine.

Technical Measures for Improving Energy Efficiency in Historic Buildings -Focused on Researches and Case Studies of the West- (역사적 건축물의 에너지 효율 향상을 위한 계획기법 -서양의 연구동향 및 사례를 중심으로-)

  • Kim, Tai-Young
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.20 no.1
    • /
    • pp.69-76
    • /
    • 2018
  • This study is to research technical measures for improving energy efficiency in the conservation and reuse of historic buildings focused on the recent research trends and case studies of the west. These measures are broadly classified into three types, the passive measures for saving energy and increasing comfort, the most cost-effective energy saving strategies, and the renewable energy sources. Firstly, the passive measures are divided into the elements and systems. The passive elements are awnings and overhanging eaves, porches, shutters, storm windows and doors, and shade trees. There are also the natural ventilation systems such as the historic transoms, roofs and attics to improve airflow and cross ventilation to either distribute, or exhaust heat. Secondly, the most cost-effective energy efficiency strategies are the interior insulation, airtightness and moisture protection, and the thermal quality improvement of windows. The energy efficiency solutions of modern buildings are the capillary-active interior insulation, the airtightness and moisture protection of interior walls and openings, and the integration of the original historic window into the triple glazing. Beyond the three actions, the additional strategies are the heat recovery ventilation, and the illumination system. Thirdly, there are photovoltaic(PV) and solar thermal energy, wind energy, hydropower, biomass, and geothermal energy in the renewable energy sources. These energy systems work effectively but it is vital to consider its visual effect on the external appearance of the building.

Experimental Study on Thermal NOx and CO Emission in a Laboratory-Scale Incinerator with Reversed Secondary Air Jet Injection (역방향 2차 공기 주입 방식을 적용한 소각 연소로의 Thermal NOx 및 CO 배출특성에 대한 축소모형실험 연구)

  • Choi, Chonggun;Choi, Woosung;Shin, Donghoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.8
    • /
    • pp.503-510
    • /
    • 2016
  • Incinerators generally emit pollutants such as NOx and CO during the combustion process. In this paper, pollutant emissions and temperature distributions were studied in a simulated incinerator with a reversed (relative to the flue gas flow) secondary air injection system. The experiments were performed by using a lab-scale furnace in order to evaluate the effects of the injection location, direction and flow rate of secondary air jets. The emission of NOx was lower in the case of reversed secondary air injection than in the case of cross injection, due to the recirculation and mixing of the exhaust gas. In the reversed air injection cases, thermal NOx emissions decreased as secondary air ratio increased from 30 to 60 and slightly increased at secondary air ratios higher than 60. In most cases, CO emissions were not detected except for a few reversed secondary air injection cases, in which cases CO concentrations below 2ppm were observed.

A Study on Diesel Engine Performance with Ar and $CO_2$ Addition (Ar과 $CO_2$ 첨가에 따른 디젤기관의 성능에 관한 연구)

  • 정영식;이상만;채재우
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.4
    • /
    • pp.93-99
    • /
    • 1997
  • The re quest to develop the engines that are able to run without air or with very little oxygen condition is raised with the interest of ocean science or the mines. This research had already be gun before the world war II, but had been stagnant owing to the appearance of nuclear power. Recycle diesel engines have ability to run under the above mentioned condition the recycle diesel engine recirculates exhaust gases into intake port and consumes additional oxygen supplied by oxygen tank. Carbon dioxide is controlled by the absorber. The combustion and emission characteristics of recycle diesel engines are quite different with conventional one because the working fluids of recycle diesel engines consist of Ar, $CO_2$ and $O_2$ as well as $N_2$. Recycle diesel engine is therefore different with general diesel engine from the viewpoint of intake air composition. It is required to investigate the effect of intake composition in the combustion and emission to know recycle diesel engine. In this study, NOx concentration, smoke and cylinder pressure are measured with the variation of Ar and $CO_2$ Reduces show that the addition of Ar reduces NOx but increases smoke. Otherwise $CO_2$ reduces smoke and NOX simultaneously. Only $CO_2$ increases the ignition delay and both gases increase fuel consumption Ar addition is superior to $CO_2$ addition for the performance of recycle diesel engine system but $CO_2$ has the avantage with respect to emission.

  • PDF

A Study on NOx Reduction Characteristics of LNT Catalyst with Fuel Injection Control in Light-duty Diesel Engine (승용디젤엔진의 연료분사 제어를 통한 LNT 촉매의 NOx 저감 특성에 관한 연구)

  • Hwang, Seung-Kwon;Ko, A-Hyun;Yoon, Joo-Wung;Myung, Cha-Lee;Park, Sim-Soo;Kim, Eun-Seok
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.4
    • /
    • pp.150-155
    • /
    • 2012
  • Lean NOx Trap (LNT) catalysts are capable of reducing exhaust NOx emissions from diesel engines. LNT stores NOx in lean condition and exhausts N2 by reducing NOx in rich condition. NOx reduction characteristic of LNT catalysts using throttle position sensor and fuel injection timing control for light-duty diesel engine was investigated. In contrast to SCR system, LNT catalyst uses diesel fuel in resuctant. Also if the concentration of reductant is exceeded, excessive amount of reductant will slip throughout LNT and cause another emission problem. Thus LNT regeneration with precise engine control established that can make higher NOx conversion efficiency and lower fuel penalty, prevent another emission problem. NOx and reductant concentration were measured by the NOx sensor and Mexa7100D equipped inlet and outlet of catalyst. As a result of engine test, regeneration strategy has reached high of 77.8% NOx conversion efficiency according to engine operation condition. Moreover, we have proved that it is possible to use regeneration strategy of LNT within 5% fuel penalty.

Nonlinear Static Model-based Feedforward Control Algorithm for the EGR and VGT Systems of Passenger Car Diesel Engines (승용디젤엔진의 EGR, VGT 시스템을 위한 비선형 정적 모델 기반 피드포워드 제어 알고리즘 설계)

  • Park, Inseok;Park, Yeongseop;Hong, Seungwoo;Chung, Jaesung;Sohn, Jeongwon;Sunwoo, Myoungho
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.21 no.6
    • /
    • pp.135-146
    • /
    • 2013
  • This paper presents a feedforward control algorithm for the EGR and VGT systems of passenger car diesel engines. The air-to-fuel ratio and boost pressure are selected as control indicators and the positions of EGR valve and VGT vane are used as control inputs of the EGR and VGT controller. In order to compensate the non-linearity and coupled dynamics of the EGR and VGT systems, we have proposed a non-linear model-based feedforward control algorithm which is obtained from static model inversion approach. It is observed that the average modeling errors of the feedforward algorithm is about 2% using stationary engine experiment data of 225 operating conditions. Using a feedback controller including proportional-integral, the modeling error is compensated. Furthermore, it is validated that the proposed feedforward algorithm generates physically acceptable trajectories of the actuator and successfully tracks the desired values through engine experiments.