• Title/Summary/Keyword: evaluation modules

Search Result 438, Processing Time 0.022 seconds

A Study on the Policy of Cryptographic Module Verification Program (암호모듈 검증 정책에 관한 연구)

  • Choi, Myeong-Gil;Jeong, Jae-Hun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.1
    • /
    • pp.255-262
    • /
    • 2011
  • The advancement of information and communication technology has caused a few dysfunction such as hacking. To keep an organization from a harmful hacking, demands for cryptographic modules have been increased. However, the evaluation criteria of cryptographic modules in Korea have been less firmly established. It is difficult for the consumers of cryptographic module to choose an appropriate cryptographic module, and to establish interoperability between applications and cryptographic modules. This study analyzes evaluation criteria, evaluation processes and evaluation policy of CMVP(Cryptographic Module Verification Program) in the advanced countries. The paper suggests a policy for Korea CMVP, in resulting a provision of foundations for international standard and cooperations for international cryptographic policies and systems.

Reliability Evaluation for Photovoltaic Modules (태양전지 모듈의 신뢰성 평가)

  • Tanaka, Hirokazu;Kim, Keun-Soo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.19 no.2
    • /
    • pp.1-5
    • /
    • 2012
  • Long-term reliability of Si photovoltaic modules is a crucial issue for the cost-reduction on the power-supply system. To elevate this reliability, several environmental tests have been created as qualification and certification procedures. This paper gives an overview about recent researches of reliability tests for Si photovoltaic modules.

A Study on Learning Modules for Course Embedded Assessment of Soft Skills Program Outcomes (소프트스킬 프로그램 학습성과의 교과기반 평가(CEA)를 위한 학습모듈(안)에 관한 연구)

  • Kang, Sang Hee
    • Journal of Engineering Education Research
    • /
    • v.23 no.6
    • /
    • pp.40-50
    • /
    • 2020
  • This paper proposes learning modules as a kind of integrated instruction model for soft skills program outcomes to enable CEA. Learning modules consist of course learning objectives(outcomes) described in detail, learning content(elements), learning activities(teaching learning methods), evaluation methods, evaluation rubrics so that they can be evaluated based on the performance criteria of the program learning outcomes. The unit of time for the learning module is 50 minutes. If this learning module is applied, it is expected that the soft skill program outcomes can be evaluated in the technical course. As a result of the expert feasibility study, the positive answers were much higher than the negative answers in most of the questions about the composition of the learning module or the method of managing the class.

Development of data acquisition and analysis program modules for leakage current of polymeric insulators using the Labview software (Labview를 이용한 배전용 폴리머애자의 누설전류 측정 및 분석 프로그램 개발)

  • Cho, Seong-Soo;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1969-1971
    • /
    • 2000
  • This paper presents a data acquisition and analysis program modules that has been developed using the Labview program. These program modules can use to acquire and analyze leakage current data of insulator under different contamination conditions. The experimental hardware made up salt fog chamber, AC/DC power supply, transducer (shunt resistor), measurement devices and PC with the GPIB (General Purpose Interface Bus). And analysis program modules can calculate pulse level count, accumulated charge, average leakage current, power spectrum, and harmonics. The result of applying these analytical program modules to polymeric insulator is available for evaluation of leakage current characteristic of outdoor insulators.

  • PDF

Experimental Investigations for Thermal Mutual Evaluation in Multi-Chip Modules

  • Ayadi, Moez;Bouguezzi, Sihem;Ghariani, Moez;Neji, Rafik
    • Journal of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.1345-1356
    • /
    • 2014
  • The thermal behavior of power modules is an important criterion for the design of cooling systems and optimum thermal structure of these modules. An important consideration for high power and high frequency design is the spacing between semiconductor devices, substrate structure and influence of the boundary condition in the case. This study focuses on the thermal behavior of hybrid power modules to establish a simplified method that allows temperature estimation in different module components without decapsulation. This study resulted in a correction of the junction temperature values estimated from the transient thermal impedance of each component operating alone. The corrections depend on mutual thermal coupling between different chips of the hybrid structure. A new experimental technique for thermal mutual evaluation is presented. Notably, the classic analysis of thermal phenomena in these structures, which was independent of dissipated power magnitude and boundary conditions in the case, is incorrect.

Performance Evaluation of SiC Honeycomb Modules Used for Open Volumetric Solar Receivers (개방형 체적식 흡수기를 위한 SiC 허니컴 모듈의 성능 평가)

  • Chai, Kwan-Kyo;Lee, Hyun-Jin;Kim, Jong-Kyu;Yoon, Hwan-Ki;Lee, Sang-Nam;Han, In-Sub;Seo, Doo-Won
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.120-125
    • /
    • 2012
  • Daegu Solar Power Tower Plant of a 200 kW thermal capacity uses an open air receiver. An air receiver is generally based on the volumetric receiver concept with porous ceramic absorbers. Because absorber material is important in the volumetric receiver, ceramic materials with excellent thermal conductivity, high solar absorptivity and good thermal stability have been researched. KIER also developed SiC honeycomb absorber modules and evaluated performance of the modules at the KIER solar furnace. For performance evaluation, we made an open volumetric receiver containing the modules and measured the outlet temperature and the efficiency. It is demonstrated that performance of the KIER absorber is comparable to that of a reference absorber developed by DLR.

  • PDF

Performance Evaluation of Anti-Reflection Coating on Photovoltaic Modules (태양광 모듈의 반사방지 코팅 성능 평가)

  • Kang, Soyeon;Kim, Juhee;Kim, Jungsik;Oh, Wonwook;Chan, Sungll
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.5
    • /
    • pp.1-8
    • /
    • 2016
  • In this paper, we evaluated the effect of a silica-based Anti-Reflection(AR) coating for PV modules. The coating technique can be easily applied to large-scale PV modules at room temperature with improvements of the optical properties that is qualified by the optical transmission measurements on the coated cover glass of the modules. The power improvement of the large-scale PV modules shows the increasing about 2.4% at standard condition of the coating technique on average. To improve the AR coating effect of the PV modules, we have characterized the individual PV modules by the measurements of DC power output, modified performance ratio(PRm) and the regression. The results show that the significant improvements of the AR coating effect are 6.4%, 5.5% and 4.5% of increasing of the performances by using the measurements of DC power output, modified performance ratio(PRm) and the regression, respectively.

A Study on Analysis of the Implementation Status and the Advancement of Computerized Maintenance Management System (CMMS) in Korean Companies (한국기업의 설비관리정보시스템(CMMS) 구현실태 분석과 고도화에 관한 연구)

  • Ku, Sung Tae;Kim, Chang Eun
    • Journal of Korean Society for Quality Management
    • /
    • v.41 no.4
    • /
    • pp.693-708
    • /
    • 2013
  • Purpose: This study is to develop an evaluation model for analysis of CMMS Implementation status and provide CMMS advancement methods to maximize implementation effect through the evaluation model. Methods: After extracting common modules from CMMS packages and establishing evaluation standard for each module, then the evaluation standard is applied to 33 Korean companies for evaluating their own current implementation status. Results: Preventive maintenance and analysis information modules were considered the most vulnerable in Korean companies which have introduced CMMS packages. And the reason why preventive maintenance is vulnerable is that there is poor build-up of their own preventive maintenance standards. Conclusion: Korean companies which will introduce CMMS need to make preventive maintenance standards, and data of the materials and the equipment to improve the effectiveness in advance.

Performance Assessment of Sputter-Coating-Colored BIPV Modules Through Field Test (현장 실험을 통한 Sputter Coating 컬러 BIPV 모듈의 발전성능 평가)

  • Lee, Hyo-Mun;Yoon, Jong-Ho;Kim, Hyun-Il;Lee, Gun-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.40 no.5
    • /
    • pp.1-12
    • /
    • 2020
  • To assess the performance and characteristics of colored building-integrated photovoltaic (BIPV) modules, a comparative assessment of empirical performance was conducted on colored BIPV modules (gray, blue, and orange) and general BIPV module. These modules were installed on the south-facing slope (30°) for comparative assessment through a field test. Monitoring data were collected every 10 min from December 20, 2019 to January 21, 2020 and used to performance and characteristics analysis. Performance ratio and module efficiency were utilized during performance indexing for comparative assessment. For general BIPV modules, the operational efficiency was analyzed at 16.63%, whereas for colored BIPV modules, 13.70% (gray), 15.12 % (blue), and 14.49% (orange) were analyzed. It was discovered that the efficiency reduction caused by transmission losses owing to the application of colored cover glasses were 17.74% (gray), 9.05% (blue), and 9.86 % (orange), under field testing conditions. These values turned on an additional 7% reduction in efficiency for gray BIPV modules, compared to the degradation resulting from transmission drop (gray: 10.87%, blue: 8.99%, and orange: 9.02%) calculated using the efficiency of each module in standard test conditions (STC). Performance ratio analysis resulted in the following values: 0.92 for general BIPV modules, and 0.85 (gray), 0.91 (blue), and 0.91 (orange) for colored BIPV modules. As demonstrated by the above results, modules with a colored cover glass may differ in their operational performance depending on their color, unlike general modules. Therefore, in addition to the performance evaluation under STC, additional factors of degradation require consideration through field test.

A Selecting Model for the Technology Modular Alternatives Based on Development Effectiveness (개발효용성에 근거한 기술대체모듈의 선정모형)

  • Kim, Ki-Chan;Ahn, Ki-Hyun;Kang, Il-Jung;Kwon, Cheol-Shin
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2007.11a
    • /
    • pp.152-155
    • /
    • 2007
  • The object of this research is to evaluate the priority of R&B project alternatives which were already screened by both feasibility and suitability of technological performance. This research is a selection model for R&D project alternatives after setting phase. And it is designed by CHP model which include individual and mutual weights. This model have 5 steps. (1) Setting Technology-Modules derived on the setting phase (2) Presenting the evaluation standards divided with 'M-Field' and 'T-Field' (3) Assessing the evaluation standard and technology modules (4) Obtaining and integrating the individually and mutually effective weights (5) Selecting the technology modules based on the priority of order by CHP. Through these steps, this model can suggest the evaluation way from specific technology levels to project level. And it can be guaranteed to perform the selected module set.

  • PDF