• Title/Summary/Keyword: ethylene glycol method

Search Result 328, Processing Time 0.028 seconds

Fabrication of Nano-sized Titanate Powders by an Ethylene Glycol Solution Route

  • Lee, S.J.;Lee, M.J.;Yoon, Y.S.
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09a
    • /
    • pp.440-441
    • /
    • 2006
  • Several titanate powders ($Al_2TiO_5,\;SrTiO_3$, etc.) were synthesized by an ethylene glycol solution route. Titanium isopropoxide and nitrate salts were dissolved in stoichiometric proportions in liquid-type ethylene glycol without any precipitation. The parent precursor sols were dried to porous gels, and then the gels were calcined and crystallized. All synthesized titanate powders had stable crystallization behavior at low temperature and high specific surface area after a simple ball-milling process. A three-component PZT $(Pb(Zr_{0.52}{\cdot}Ti_{0.48})O_3)$ powder was also synthesized successfully by the ethylene glycol method. In this study, the characteristics of the multi-component titanate powders by the ethylene glycol method are examined.

  • PDF

Synthesis of Two-Component Titanate Powders Using Ethylene Glycol Solution (에틸렌글리콜 용액을 이용한 2성분계 Titanate 분말의 합성)

  • 이상진;권명도
    • Journal of Powder Materials
    • /
    • v.9 no.5
    • /
    • pp.346-351
    • /
    • 2002
  • Pure and fine, two-component titanate powders (barium titanate, calcium titanate etc.) were synthesized by an ethylene glycol method. Titanium isopropoxide and other metal ionic salts were dissolved in liquid-type ethylene glycol without any precipitation. In non-aqueous system, the amount of ethylene glycol affected the solubility and homogeneity of metal cation sources in the solution. At the optimum amount of the polymer, the metal ions were dispersed effectively in solution and a homogeneous polymeric network was formed. Most of the synthesized powders had sub-micron or nano-size primary particles after calcination and the agglomerated calcined powders were easily ground by ball milling process. All synthesized titanate powders had stable crystallization behavior at low temperature and high specific surface area after ball milling. The crystallization behavior and the microstructures of the calcined powders were affected on the ethylene glycol content.

Determination of Icing Inhibitors (Ethylene Glycol Monomethyl Ether and Diethylene Glycol Monomethyl Ether) in Ground Water by Gas Chromatography-Mass Spectrometry

  • Shin, Ho-Sang;Jung, Dong-Gyun
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.6
    • /
    • pp.806-808
    • /
    • 2004
  • A gas chromatography/mass spectrometric assay method has been developed for the simultaneous determination of icing inhibitors, ethylene glycol monomethyl ether and diethylene glycol monomethyl ether in ground water contaminated with JP-8. Ethylene glycol monobutyl ether and ethylene glycol monoethyl ether were used as the internal standard and surrogate, respectively. 100 mL of ground water was extracted twice with 20 mL of methylene chloride. The extract was concentrated to dryness, dissolved with 100 ${\mu}$L of methanol and analyzed by GC-MS (SIM). The use of an Innowax column gave the peaks good chromatographic properties, and the extraction of these compounds from samples gave recoveries of about 50% with small variations. The method detection limits of the target compounds were in a range of 0.5-0.8 ng/mL in ground water.

Clinicopathological Diagnosis of Gentamicin and Ethylene glycol Induced Acute Renal Failure in Dogs (개에서 Gentamicin과 Ethylene glycol에 임상병리학적 진단)

  • 김지현;이영재;이경갑
    • Journal of Veterinary Clinics
    • /
    • v.17 no.2
    • /
    • pp.327-333
    • /
    • 2000
  • The diagnostic method was, evaluated in experimentally induced acute renal failure in doges. Ten male dogs weighing from 5 to 10 kg were assigned to two groups(gentamicin & ethylene glycol treated group) al random. Gentamicin sulfate at 10 mg/kg of body weight, t.i.d., for 7 days and ethylene glycol at 3 ml/kg of body weight once used in a randomized complete block design with tee treatments in block. The samples(blood, urine) were collected before and 1,3,5,7,9 and l1th day after administration. The serum creatinine concentration and BUN(blood urea nitrogen) were sig- nificantly increased at the 7th day than before administration in gentamicin treated group (p<0.05), bolt there was significant increase at the 1st day than before administration in ethylene glycol treated group(p<0.05). The urine GGT(gramma glutamyl transpeptidase) and GGT/creatinine were significantly increased at the 1st (lay after administration in gentamicin treated group (p<0.05). But in ethylene glycol treated group, there was no significant changes. The value of FENa (fractional excretion of sodium) was significantly increased at the 3rd day after administration in gentamicin treated group and the 1 st day after administration in ethylene glycol treated group (p<0.05). These results suggest that FENa was a good parameter of renal function in dogs with acute renal failure.

  • PDF

A Study on Physical Properties and Catalytic Combustion of Methane of Sr Hexaaluminate Prepared using 1-butanol and Ethylene Glycol (1-butanol과 ethylene glycol을 이용하여 합성한 Sr hexaaluminate의 물리적 특성 및 메탄 연소 반응에 관한 연구)

  • Shon, Jung Min;Woo, Seong Ihl
    • Korean Chemical Engineering Research
    • /
    • v.45 no.3
    • /
    • pp.209-214
    • /
    • 2007
  • Sr hexaaluminate($Sr_{1-x}La_xMnAl_{11}O_{19-\alpha}$) were prepared by sol-gel method of metal alkoxide with 1-butanol or ethylene glycol as a solvent. The physical properties of prepared hexaaluminates were examined by TG/DTA, XRD and $N_2$ adsorption. When ethylene glycol was used as a solvent, the decomposition reaction and dehydroxylation reaction was observed above $400^{\circ}C$ and the temperature of the formation of a crystal structure of hexaaluminate was also increased resulting in small specific surface area and low catalytic activity of methane compared to Sr-hexaaluminate with 1-butanol.

Determination of ethylene glycol in alkali wastewater by gas chromatography/mass spectrometry (GC/MS를 이용한 알칼리 폐수 중 ethylene glycol 정량)

  • Park, Gyo-Beom;Lee, Sueg-Geun
    • Analytical Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.527-531
    • /
    • 2004
  • Treatment with aqueous sodium hydroxide solution plays an important role to impart certain desirable properties - feel and luster on the surface of polyester fiber. In this process alkali wastewater contains disodium terephthalate, ethylene glycol (EG) and residual sodium hydroxide. In this paper we report a new method containing the pretreatments of derivatization with benzoyl chloride and solvent extraction using pentane. The calibration curve of EG determined by GC/MS-SIM shows a good linearity in the range of 0.1 to $25{\mu}g/mL$ having the standard deviation of ${\leq}8.7%$. The recovery and the detection limit of this method are 91.9-93.7% and $0.05{\mu}g/mL$ respectively.

GC/MS Analysis of Ethylene Glycol in the Contaminated Lubricant Oil Through Solvent Extraction Followed by Derivatization using Bistrimethylsilyltrifluoroacetamide (BSTFA) (엔진윤활유 중 Ethylene Glycol의 용제추출후 bistrimethylsilyltrifluoroacetamide(BSTFA)를 이용한 GC/MS 분석에 관한 연구)

  • Lee, Joon-Bae;Kwon, O-Seong;You, Jae-Hoon;Shon, Shungkun;Sung, Tae-Myung;Paeng, Ki-Jung
    • Tribology and Lubricants
    • /
    • v.28 no.6
    • /
    • pp.315-320
    • /
    • 2012
  • For proper functioning, general machines usually need lubricant oil as a cooling, cleaning, and sealing agent at points of mechanical contact. The quality of lubricant oil can deteriorate during operation owing to various causes such as high temperature, combustion products and extraneous impurities. In this study, a heavy load stopped during operation, and the oil was analyzed to check whether any impurities were added. Extraction using acetonitrile followed by reaction with BSTFA(bistrimethylsilyl trifluoroacetamide) showed that, trimethylsilylated ethylene glycol was present in the lubricant oil. To quantify the ethylene glycol in the oil, deuterium-substituted ethylene glycol, which acted as an internal standard, was added to the sample and then extracted with the solvent. Next, the extract was reacted with the derivatizing agent(BSTFA) and then analyzed with GC/MS. The detection limit of this method was found to be $0.5{\mu}g/g$ and the recovery of oil containing $20,000{\mu}g/g$ of ethylene glycol was measured to be 94.8%. A damaged O-ring and eroded cylinder liner were found during the overhaul, which implied the leakage of coolant containing ethylene glycol into the lubricating system. The erosion of the cylinder liner was assumed to be due to cavitation of the coolant in the cooling system.

Effects of Cryoprotectants on Survival and Hatching of Black Seabream, Acanthopagrus schlegeli Embryos (감성돔, Acanthopagrus schlegeli 배의 생존과 부화에 미치는 동해방지제의 영향)

  • 임한규;장영진;조필규
    • Journal of Aquaculture
    • /
    • v.16 no.4
    • /
    • pp.262-266
    • /
    • 2003
  • In order to develop a method for the cryopreservation of fish embryos, the determination of optimal concentrations of dimethyl sulfoxide (DMSO), ethylene glycol and glycerol as individual cryoprotectants was performed by using the early embryos of black seabream, Acanthopagrus schlegeli. Optimal concentrations of cryoprotectants were assessed in terms of effects on mortality, median lethal concentration and hatching rate of embryos. The mortality of black seabream embryos immersed in cryoprotectants was related to the concentrations of cryoprotectants and immersion times. The toxicity to embryos was lower in order of DMSO, < ethylene glycol, < glycerol. The results from the mortality, median lethal concentration and hatching rate evaluations suggest that DMSO was the most effective cryoprotectant for black seabream embryos followed by ethylene glycol, and suitable concentrations of DMSO and ethylene glycol were 2.0∼2.25M and 1.0∼1.78M, respectively, with 20 minutes of immersion time.

Synthesis and optical properties of ZnO thin films prepared by SILAR method with ethylene glycol

  • Lee, Pay-Yu;Chang, Sheng-Po;Chang, Shoou-Jinn
    • Advances in nano research
    • /
    • v.1 no.2
    • /
    • pp.93-103
    • /
    • 2013
  • An ultrasonic-mediated assisted stepwise method has been developed for depositing transparent ZnO films from aqueous solution. Rinsing in low ethylene glycol temperature was easy to produce intermediate phase of $Zn(OH)_2$, rinsing in $120^{\circ}C$ ethylene glycol was observed the diffraction peak of intermediate $Zn(OH)_2$ in early report, the rinsing temperature plays an important role in the process of $Zn(OH)_2$ phase transformed to ZnO, high rinsing temperature actually improved the intermediate phase. However, the effect of rinsing on the intermediate phase is yet to be understood clearly. The effect of different rinsing procedures, involving either of or a combination of successive ionic layer adsorption and reaction (SILAR) and ultrasonic-assisted rinsing, prior to hydrolysis in ethylene glycol was found to improve the occurrence $Zn(OH)_2$ in ZnO thin films. In the zinc complex ($[Zn(NH_3)_4]^{2+}$) solution, excess ($[Zn(NH_3)_4]^{2+}$) absorbed in glass substrate transformed incompletely to ZnO and exist as $Zn(OH)_2$ phase in thin films. In films deposited at low temperature, rinsing procedure is applied to improve excess $Zn(OH)_2$ and obtain smoother transparent thin films.

Device Development of Mixture Concentration of Ethylene Glycol Antifreeze Coolant for Vehicles (자동차 에틸렌글리콜 부동액의 혼합 농도 측정 장치 개발)

  • Lee, Dae-Woong;Lee, Eun-Woung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.8
    • /
    • pp.331-336
    • /
    • 2016
  • This study presents a coolant density calculation device and its corresponding method by using a mass flowmeter and the LabVIEW program. The method can be easily measured with a mixture of coolant and by calculating the percentage of ethylene-glycol without additional investment. The cooling water is very important in a vehicle to protect the engine, and the cooling performance is affected by the mixture concentration and coolant density. The coolant density calculation device measures the mixed concentration in the anti-freeze cooling mixture made from distilled water and ethylene-glycol in real time with the mass flowmeter that is commonly attached to the radiator or heater core. The calculation program for the mixture concentration percentage was developed using the LabVIEW software. The correlation between experimental results and the calculation was conducted for a range of temperature from 40 to $90^{\circ}C$ and by varying the mixture ratio of distilled water and ethylene-glycol. As a result, the anti-freeze coolant concentration in the volume percentage is able to monitor the coolant density in a timely basis by implementing a mixture concentration calculation program without the need for additional equipment investment. The results of the calculation for the mixture concentration level show a maximum 2.7% deviation compared to the experimental results.