• Title/Summary/Keyword: ethernet

Search Result 927, Processing Time 0.022 seconds

A Study on Architecture Design of Network Management System for DX (구축함(DX) 네트워크 관리 시스템 구조 설계에 대한 연구)

  • Lee, Kwang-Je;Chung, Jin-Wook
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.39 no.2
    • /
    • pp.95-103
    • /
    • 2002
  • We know that the all of warfare system has been becoming complex and variety in warfield thru the Gulf-War. The all of warfare electronic systems is designed to inter-operate by networks in recently. Especially Warfare Equipment systems of Men-of-War(War ship) as like KDX(Korea Destroyer, Experimental), FF(Frigate), PCC(Costal Patrol Craft), Submarine are connected by Combat System Databus to the Command system(C2 System), so C2 system can control all of equipments in ship. In this view, the status of network(Combat System Databus) is very critical parameter in war field. So In this paper, we propose the method of Network Management System construction for War ship, and especially propose the architectural design of network management system for DX(Destroyer, Experimental) equipments using SNMP(Simple Network Management Protocol). And Link Utilization is monitored by simulation. 

Transmission System of TDM signal based on E-PON (E-PON 기반 TDM 신호 전송 시스템)

  • Kwon, Jeong-Gook;Jin, Geol;Park, Chun-Kwan;Song, Han-Young;Jeon, Byung-Chun;Lee, Sang-Ho
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.12
    • /
    • pp.63-72
    • /
    • 2007
  • This paper addresses the system development that can transfer data and TDM signals simultaneously by adding TDM pseudowires functions to E-PON system. E-PON technology is one of many technologies which can realize FTTH, has raised as next generation access network solution having both low-cost Ethernet technology and optical infrastructure. TDM pseudowires service is the new voice/data conversion technology which can transfer the existing TDM circuit switched voice and data over packet switching network. In this paper, this system can provide both data and TDM service without deteriorating QoS by adding TDM pseudowires service module to E-PON, and then implementing QoS control function. Therefore, the competitive system which can transfer both data and TDM signal, can be installed.

A Study on the Transmission Characteristics and Channel Capacity of Telephone Line Communication System (전화선 통신 시스템의 전송특성 및 채널용량에 관한 연구)

  • Roh, Jae-Sung;Chang, Tae-Hwa
    • Journal of Digital Contents Society
    • /
    • v.10 no.2
    • /
    • pp.233-238
    • /
    • 2009
  • The advances in the digital communication and network technology, Internet technology and the proliferation of smart appliances in home, have dramatically increased the need for a high speed/high quality home network. As consumer electronic devices and computing devices are increasing in the home network, it is obvious that the data traffic of home network increases as well. Various home network devices want to access Internet servers to get multimedia contents. Therefore, we introduce TLC(Telephone Line Carrier) system for networked digital consumer electronic appliances within a house using Ethernet or wire/wireless technology. In the future home network environment, the primary purposes of the smart home network based TLC are to create low-cost, easily deployable, high performance, and wide coverage throughout the home. In this paper, the channel capacity of telephone line communication system is evaluated and compared as a function of transmission power, number of OFDM carrier, channel loss, and noise loss for smart home network.

  • PDF

Sensitivity Analysis on the Performance of Multimedia Stream Server using Simulation (시뮬레이선을 통한 멀티미디어 스트림 서버의 성능 민감도 분석)

  • Park, Jin-Won;Park, Chong-Won
    • Journal of the Korea Society for Simulation
    • /
    • v.15 no.2
    • /
    • pp.23-29
    • /
    • 2006
  • This paper studies the Internet stream server which serves multimedia stream services such as VoD and MoD. The Internet multimedia stream server is developed to provide 50 users with continuous multimedia stream contents simultaneously. This paper focuses on introducing design concepts, operation details and on evaluating system performance and doing sensitivity analysis with respect to the change of the system components. The performance evaluation is performed using simulation in order to identify the system component that mostly affects the system performance. The sensitivity analysis shows the service delay rates of the multimedia stream server depending on the user's service request pattern. Also, the analysis is made on the utilization rates of the core system components such as the PCI bus and the Ethernet card, and on the system performance change by adding more system components.

  • PDF

A Study on the Implement of Test Bed for Ad-hoc Networks (Ad-hoc 네트워크 테스트 베드 구현에 관한 연구)

  • Lee, Heung-Jae;Ga, Soon-Mo;Choe, Jin-Kyun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.11A
    • /
    • pp.1059-1067
    • /
    • 2006
  • AODV(Ad-hoc On-demand Distance Vector) routing protocol was devised for use of mobile nodes in Ad-hoc network. When we use the AODV routing protocol in Ad-hoc networks with high mobility, disturbance of optimized route path and link break occur. In order to solve the shortcomings, this paper proposes a new routing protocol in which new routing control messages are added to the existing AODV. The proposed protocol minimizes link break and transmission delay while is able to secure the optimized route path constantly in changes of network topology The performance of the proposed routing protocol was evaluated by using us2 network simulator. The actual Ad-hoc network test bed provides us the most reliable experimental data for Ad-hoc networks. In order to support this experimental environment, the dissertation also developed an efficient embedded system on which AODV routing protocol, NAT, Netfilter can run and other event message can be verified without declining efficiency. The correct operation of AODV routing protocol has been verified in both the Ad-hoc network test bed in which the embedded system was used, and Ad-hoc networks linked with Ethernet backbone network.

Hierarchical Power Management Architecture and Optimal Local Control Policy for Energy Efficient Networks

  • Wei, Yifei;Wang, Xiaojun;Fialho, Leonardo;Bruschi, Roberto;Ormond, Olga;Collier, Martin
    • Journal of Communications and Networks
    • /
    • v.18 no.4
    • /
    • pp.540-550
    • /
    • 2016
  • Since energy efficiency has become a significant concern for network infrastructure, next-generation network devices are expected to have embedded advanced power management capabilities. However, how to effectively exploit the green capabilities is still a big challenge, especially given the high heterogeneity of devices and their internal architectures. In this paper, we introduce a hierarchical power management architecture (HPMA) which represents physical components whose power can be monitored and controlled at various levels of a device as entities. We use energy aware state (EAS) as the power management setting mode of each device entity. The power policy controller is capable of getting information on how many EASes of the entity are manageable inside a device, and setting a certain EAS configuration for the entity. We propose the optimal local control policy which aims to minimize the router power consumption while meeting the performance constraints. A first-order Markov chain is used to model the statistical features of the network traffic load. The dynamic EAS configuration problem is formulated as a Markov decision process and solved using a dynamic programming algorithm. In addition, we demonstrate a reference implementation of the HPMA and EAS concept in a NetFPGA frequency scaled router which has the ability of toggling among five operating frequency options and/or turning off unused Ethernet ports.

Distribution System Reconfiguration Using the PC Cluster based Parallel Adaptive Evolutionary Algorithm

  • Mun Kyeong-Jun;Lee Hwa-Seok;Park June Ho;Hwang Gi-Hyun;Yoon Yoo-Soo
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.3
    • /
    • pp.269-279
    • /
    • 2005
  • This paper presents an application of the parallel Adaptive Evolutionary Algorithm (AEA) to search an optimal solution of a reconfiguration in distribution systems. The aim of the reconfiguration is to determine the appropriate switch position to be opened for loss minimization in radial distribution systems, which is a discrete optimization problem. This problem has many constraints and it is very difficult to find the optimal switch position because of its numerous local minima. In this investigation, a parallel AEA was developed for the reconfiguration of the distribution system. In parallel AEA, a genetic algorithm (GA) and an evolution strategy (ES) in an adaptive manner are used in order to combine the merits of two different evolutionary algorithms: the global search capability of GA and the local search capability of ES. In the reproduction procedure, proportions of the population by GA and ES are adaptively modulated according to the fitness. After AEA operations, the best solutions of AEA processors are transferred to the neighboring processors. For parallel computing, a PC-cluster system consisting of 8 PCs·was developed. Each PC employs the 2 GHz Pentium IV CPU, and is connected with others through switch based fast Ethernet. The new developed algorithm has been tested and is compared to distribution systems in the reference paper to verify the usefulness of the proposed method. From the simulation results, it is found that the proposed algorithm is efficient and robust for distribution system reconfiguration in terms of the solution quality, speedup, efficiency, and computation time.

Enterprise Network Weather Map System using SNMP (SNMP를 이용한 엔터프라이즈 Network Weather Map 시스템)

  • Kim, Myung-Sup;Kim, Sung-Yun;Park, Jun-Sang;Choi, Kyung-Jun
    • The KIPS Transactions:PartC
    • /
    • v.15C no.2
    • /
    • pp.93-102
    • /
    • 2008
  • The network weather map and bandwidth time-series graph are popularly used to understand the current and past traffic condition of NSP, ISP, and enterprise networks. These systems collect traffic performance data from a SNMP agent running on the network devices such as routers and switches, store the gathered information into a DB, and display the network performance status in the form of a time-series graph or a network weather map using Web user interface. Most of current enterprise networks are constructed in the form of a hierarchical tree-like structure with multi-Gbps Ethernet links, which is quietly different from the national or world-wide backbone network structure. This paper focuses on the network weather map for current enterprise network. We start with the considering points in developing a network weather map system suitable for enterprise network. Based on these considerings, this paper proposes the best way of using SNMP in constructing a network weather map system. To prove our idea, we designed and developed a network weather map system for our campus network, which is also described in detail.

Implementation of PC based Motor Fault Diagnosis System (PC 기반 전동기 고장 진단 시스템의 구현)

  • Doo, Seung-Ho;Park, Jin-Bae;Kwak, Ki-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1689-1690
    • /
    • 2006
  • This study is for implementation of PC based Motor fault diagnosis system. By using harmonics and current signals of the motor, this system diagnoses the motor condition by accumulated harmonic contribution rate. In this proposed system that was composed of 5 parts. A sensor, connection box, evaluation board, device server, and main computer are those. There were two types of sensor, one was harmonic sensor the other was current sensors. The signal was acquired by sensor, and transferred to evaluation board. Second one is connection box. Because the output type of sensor and input type of evaluation board is different, connection box was necessary. Third one was evaluation board. The signal from the sensor was converted to digital signal in evaluation board. And this signal was transferred to device server. Fourth one was device server Device server transferred the data from evaluation board to main computer. And the last one was other parts controlled by main computer. In main computer, there were communication and diagnosis algorithms. The result was derived by main computer. In the result, there were 12 categories and 5 levels of motor conditions. The proposed system had some advantages comparing with stand alone type commercial motor fault diagnosis system. The first, by using remote access it was easier to get the conditions of motor. The second, there was no need to handle the sensors when users measured the motor signals. By this property, no one was necessary at motor location site. The third, this system was less restricted by times and places than commercial stand alone type diagnosis system. Therefore users can operate this system only using the main computer. Once the sensors are installed at the motor, users doesn't need to move to check up the condition of motors. Moreover, if there is ethernet hub, many motors can be not only diagnosed at once but also decreased its cost.

  • PDF

Development of Log Processing Module and Log Server for Ethernet Shipboard Integration Networks (이더넷 기반 선박 통합 네트워크를 위한 로그 처리 모듈 및 로그 서버의 개발)

  • Hwang, Hun-Gyu;Yoon, Jin-Sik;Seo, Jeong-Min;Lee, Seong-Dae;Jang, Kil-Woong;Park, Hyu-Chan;Lee, Jang-Se
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.2
    • /
    • pp.331-338
    • /
    • 2011
  • Objectives of shipboard integration networks are to exchange and manage integrated information. Shipboard integration networks use UDP(User Datagram Protocol) multicast for the exchange of information. However, such information can be missed or damaged because UDP can't guarantee reliability. The standard of shipboard integration networks defines error log functions for the missed or damaged information. In this paper, we analyze internal and external log functions. The internal log function records errors internally, and the external log function sends error messages to a log server and records them in a database. We also develop a log processing module and log server for the external log function.