• 제목/요약/키워드: etched surface

검색결과 754건 처리시간 0.031초

활성화 반응 증발법에 의한 Al2O3 박막 형성 (Formation of Al2O3 Film by Activated Reactive Evaporation Method)

  • 박용근;최재하
    • 열처리공학회지
    • /
    • 제14권5호
    • /
    • pp.292-296
    • /
    • 2001
  • In this work, an ultra-high vacuum activated reactive evaporation equipment was built. With reaction of Al and oxygen plasma, $Al_2O_3$ was deposited on the surface of etched Al foil. The chamber was evacuated down to $2{\times}10^{-7}$ torr initially. The Ar and $O_2$ gas introduced into the chamber to maintain $5{\times}10^{-5}$ torr during deposition. Ar gas prevents recombining of the ionized oxygen. Evaporation was maintained by electron beam evaporator continuously. Heating filament and electrode were used in order to generate plasma. The substrate bias of -300V was introduced to accelerate deposition of evaporated Al atoms. The composition and morphology of deposited $Al_2O_3$ films were analyzed by x-ray photoelectron spectroscopy(XPS) and atomic force microscopy (AFM), respectively. The Al oxide was formed on the surface of etched Al foil. According to AFM results, the surface morphology of $Al_2O_3$ film indicates uniform feature. Dielectric characteristic was measured as a function of frequency. Measured withstanding voltage and capacitance were 52V and $24{\mu}F/cm^2$, respectively. The obtained $Al_2O_3$ film shows clean condition without contaminants, which could be adapted to capacitor production.

  • PDF

Black Silicon Layer Formation using Radio-Frequency Multi-Hollow Cathode Plasma System and Its Application in Solar Cell

  • U. Gangopadhyay;Kim, Kyung-Hae;S.K. Dhungel;D. Mangalaraj;Park, J.H.;J. Yi
    • Transactions on Electrical and Electronic Materials
    • /
    • 제4권5호
    • /
    • pp.10-14
    • /
    • 2003
  • A low-cost, large area, random, maskless texturing scheme independent of crystal orientation is expected to have significant impact on terrestrial photovoltaic technology. We investigated silicon surface microstructures formed by reactive ion etching (R IE) in Multi-Hollow cathode system. Desirable texturing effect has been achieved when radio-frequency (rf) power of about 20 Watt per one hollow cathode glow is applied for our RF Multi -Hollow cathode system. The black silicon etched surface shows almost zero reflectance in the visible region as well as in near IR region. The etched silicon surface is covered by columnar microstructures with diameters from 50 to 100 nm and depth of about 500 nm. We have successfully achieved 11.7 % efficiency of mono-crystalline silicon solar cell and 10.2 % for multi-crystalline silicon solar cell.

인산 부식액의 수세가 교정용 접착레진의 전단결합강도에 미치는 영향 (THE EFFECT OF WASHING PHOSPHORIC ACID ETCHANT ON SHEAR BOND STRENGTH OF AN ORTHODONTIC ADHESIVE)

  • 김희균;이기수;박영국
    • 대한치과교정학회지
    • /
    • 제26권5호
    • /
    • pp.497-507
    • /
    • 1996
  • 산부식된 법랑질표면의 오염은 브라켓의 레진 접착력에 영향을 미친다고 보고되어 왔다. 이 연구의 목적은 인산액이 법랑질과 반응하여 수용성염 및 불수용성염을 형성하는 경우와 부식표면이 타액오염된 경우에, 이의 수세시간이 브라켓의 레진접착 전단결합강도에 미치는 영향을 관찰하기 위하여 시행되었다. 치과 교정치료를 목적으로 발거된 총 234개의 상하악 소구치를 대상으로 $37\%$ 인산액으로 60초간 부식한 군, $20\%$ 인산액으로 50초간 부식 한 군, $37\%$ 인산액으로 60초간 부식 하고 타액오염시킨 군으로 나누고, 인산부식군은 각각 0초, 5초, 10초, 20초간 수세하고, 타액오염 군은 0초, 20초,30초 수세하거나, 재부식후 5초, 10초, 20초간 수세한후 레진접착제로 브라켓을 접착하였다. 5각군의 법랑질표면을 주사전자현미경과으로 검경하고, 전단결합강도를 측정하여 비교검토한 결과 다음의 결과를 얻었다. 1) 산부식후 수세를 하지않으면 레진접착제의 전단결합강도가 현저히 감소 하였다. 2) $37\%$ 인산부식액으로 부식시키고 5초, 10초, 및 20초간 수세한후의 접착레진 전단결합강도 사이에는 차이가 없었다. 3) $20\%$ 인산액으로 부식시키고 5초, 10초, 및 20초간 수세한 후의 전단결합강도사이에는 차이가 없었으나, 5초간 수세후의 전단결합강도는 측정치의 변이가 매우컸다. 4) 부식후 타액으로 오염된 법랑질 표면은 5초, 20초간 및 30초간 수세후 및 재부식 한 후의 브라켓접착레진의 전단결합강도사이에 차이가 없었으나, 5초간 수세만한 군의 전단결합강도는 변이가 매우컸다. 이상의 결과에 의하면 수용성 염이 생성되는 농도의 인산액으로 부식하고 5초간 수세후 불수용성 염이 생성되는 농도의 인산액으로 10초간 수세후에, 그리고 타액오염된 부식표면을 재부식없이 20초간 수세후에 브라켓을 접착하면 임상적으로 유용한 부라켓 접착레진의 전단 결합강도를 얻을수 있을 것으로 추정된다.

  • PDF

Microabrasive로 처리한 상아질표면에 대한 복합레진의 결합강도에 관한 연구 (A STUDY OF THE BOND STRENGTHS OF COMPOSITE RESIN TO DENTIN SURFACES PREPARED WITH MICROABRASIVE)

  • 최경규;민병순
    • Restorative Dentistry and Endodontics
    • /
    • 제22권1호
    • /
    • pp.61-75
    • /
    • 1997
  • The bond strengths of composite resin to tooth dentin vary with the methods of cavity preparation and surface treatment. Recent developments in techniques of dentinal surface treatment have renewed interest in microabrasive as a means of tooth preparation, The purpose of this study was to determine the effects of a new method of cavity preparation on the bond of composite resin to dentin. Freshly extracted 144 healthy human third molars were used in this study. The dentin surfaces prepared with #600 SiC abrasive paper were divided into control and air abrasion groups according to the method of dentin surface preparation using different combinations of delivery pressure, time, and acid etching. The shear bond strengths were measured after the composite resin (Clearfil Photo Bright) was bonded to prepared dentin surfaces by light-curing using a dentin bonding system (All-bond 2), In addition, the average surface roughness was measured to investigate the effect of differently prepared dentin surfaces on the shear bond strengths. The surface changes of prepared dentin and the debonded dentin surfaces were observed with SEM (S-2300, Hitachi Co., Japan). The following results from this-study were obtained ; 1. There was no significant difference of shear bond strengths according to the changes of delivery pressure and time. 2. The shear bond strengths were lower than the control in the air abraded-only groups, but those of the additional acid-etched groups were higher than the control. 3. The shear bond strengths to all air-abraded surfaces were increased by acid etching. 4. The correlation between shear bond strengths and surface roughness was not certain, although the mean surface roughness of all air-abraded surfaces has increased evidently while it has slightly decreased for additional acid etching. 5. On SEM examination, the dentinal tubules were almost occluded in the air abraded-only groups, but those were opened in the additional acid-etched groups. 6. The debonded surfaces were showed adhesive failure mode in the air abraded- only groups, while those were showed mainly the mixed and cohesive failure mode in the additional acid-etched groups. These results suggest that the layer produced during cavity preparation or surface treatment with air abrasion must be removed for maximum bond strength of composite resin to dentin.

  • PDF

Ti-49.5Ni (at%)합금의 다공성 구조가 뼈 세포 흡착에 미치는 영향 (Effect of Pore Structures of a Ti-49.5Ni (at%) Alloy on Bone Cell Adhesion)

  • 임연민;최정일;강동우;남태현
    • 한국재료학회지
    • /
    • 제22권2호
    • /
    • pp.66-70
    • /
    • 2012
  • Ti-Ni alloys are widely used in numerous biomedical applications (e.g., orthodontics, cardiovascular science, orthopaedics) due to their distinctive thermomechanical and mechanical properties, such as the shape memory effect, superelasticity and low elastic modulus. In order to increase the biocompatibility of Ti-Ni alloys, many surface modification techniques, such as the sol-gel technique, plasma immersion ion implantation (PIII), laser surface melting, plasma spraying, and chemical vapor deposition, have been employed. In this study, a Ti-49.5Ni (at%) alloy was electrochemically etched in 1M $H_2SO_4$+ X (1.5, 2.0, 2.5) wt% HF electrolytes to modify the surface morphology. The morphology, element distribution, crystal structure, roughness and energy of the surface were investigated by scanning electron microscopy (SEM), energy-dispersive Xray spectrometry (EDS), X-ray diffractometry (XRD), atomic force microscopy (AFM) and contact angle analysis. Micro-sized pores were formed on the Ti-49.5Ni (at%) alloy surface by electrochemical etching with 1M $H_2SO_4$+ X (1.5, 2.0, 2.5) wt% HF. The volume fractions of the pores were increased by increasing the concentration of the HF electrolytes. Depending on the HF concentration, different pore sizes, heights, surface roughness levels, and surface energy levels were obtained. To investigate the osteoblast adhesion of the electrochemically etched Ti-49.5Ni (at%) alloy, a MTT test was performed. The degree of osteoblast adhesion was increased at a high concentration of HF-treated surface structures.

전류밀도와 식각시간이 니켈-크롬-베릴륨 합금의 식각깊이와 표면조도에 미치는 영향 (EFFECTS OF CURRENT DENSITY AND ETCHING TIME ON ETCHING DEPTH AND SURFACE ROUGHNESS OF NI-CR-BE ALLOY)

  • 정성권;전영찬;정창모;임장섭
    • 대한치과보철학회지
    • /
    • 제40권4호
    • /
    • pp.323-334
    • /
    • 2002
  • The purpose of this study is to investigate which current densities and etching times will result in an optimal etching depth and surface roughness when an Ni-Cr-Be alloy is etched with 30% perchloric acid($HClO_4$). For this study, observations were made by means of an optical three-dimensional surface roughness measuring machine and a scanning electron microscope. The etchings took place under the following conditions using current densities of $300mA/cm^2\;450mA/cm^2,\;600mA/cm^2$ and $750mA/cm^2$, and using etching time of three, five, six, seven and nine minutes. Under the conditions, the experiments reached the following conclusions. 1. When the current density is above $450mA/cm^2$ and the etching time is longer than five minutes, the etching depth increased as the current density and etching time increased. And the surface roughness was significantly influenced by the interaction of the current density and etching time. 2. Under the etching conditions of $600mA/cm^2$ and five minutes, the optimal etching depth for a resin cement space and the highest surface roughness for mechanical retention were obtained. The etching depth and surface roughness were $32.86{\mu}m$ and $7.90{\mu}m$, respectively. 3. Observations under the scanning electron microscope showed that both the corrosion at the grain boundary and the corrosion within the grain occurred on the etched surface. It was also observed that the corrosion at the grain boundary became more severe as the current density and etching time increased. In addition. at higher current densities and longer etching times general corrosion appeared.

The Effects of a Er:YAG Laser on Machined, Sand-Blasted and Acid-Etched, and Resorbable Blast Media Titanium Surfaces Using Confocal Microscopy and Scanning Electron Microscopy

  • Park, Jun-Beom;Kim, Do-Young;Ko, Youngkyung
    • Journal of Korean Dental Science
    • /
    • 제9권1호
    • /
    • pp.19-27
    • /
    • 2016
  • Purpose: Laser treatment has become a popular method in implant dentistry, and lasers have been used for the decontamination of implant surfaces when treating peri-implantitis. This study was performed to evaluate the effects of an Erbium-doped:Yttrium-Aluminum-Garnet (Er:YAG) laser with different settings on machined (MA), sand-blasted and acid-etched (SA), and resorbable blast media (RBM) titanium surfaces using scanning electron microscopy and confocal microscopy. Materials and Methods: Four MA, four SA, and four RBM discs were either irradiated at 40 mJ/20 Hz, 90 mJ/20 Hz, or 40 mJ/25 Hz for 2 minutes. The specimens were evaluated with scanning electron microscopy and confocal microscopy. Result: The untreated MA surface demonstrated uniform roughness with circumferential machining marks, and depressions were observed after laser treatment. The untreated SA surface demonstrated a rough surface with sharp spikes and deep pits, and the laser produced noticeable changes on the SA titanium surfaces with melting and fusion. The untreated RBM surface demonstrated a rough surface with irregular indentation, and treatment with the laser produced changes on the RBM titanium surfaces. The Er:YAG laser produced significant changes on the roughness parameters, including arithmetic mean height of the surface (Sa) and maximum height of the surface (Sz), of the MA and SA surfaces. However, the Er:YAG laser did not produce notable changes on the roughness parameters, such as Sa and Sz, of the RBM surfaces. Conclusion: This study evaluated the effects of an Er:YAG laser on MA, SA, and RBM titanium discs using confocal microscopy and scanning electron microscopy. Treatment with the laser produced significant changes in the roughness of MA and SA surfaces, but the roughness parameters of the RBM discs were not significantly changed. Further research is needed to evaluate the efficiency of the Er:YAG laser in removing the contaminants, adhering bacteria, and the effects of treatment on cellular attachment, proliferation, and differentiation.

Nd : YAG레이저 조사시(照射時) 치아(齒牙) 법랑질(琺瑯質)의 변화(變化) 및 접착력(接着力)에 관(關)한 연구(硏究) (A STUDY ON THE EFFECT OF PULSED Nd : YAG LASER IMPACTS TO THE ENAMEL SURFACE AND BOND STRENGTH WITH COMPOSITE RESIN)

  • 박종만;배태성;송광엽;박찬운
    • 대한치과보철학회지
    • /
    • 제29권2호
    • /
    • pp.85-101
    • /
    • 1991
  • The purpose of this study was to determine the optimum range of laser energy density to the enamel surface of permanent incisors when they are irradiated with the pulsed Nd : YAG laser, Laser impacts on each experimental group were made at energy density of $20\sim50J/cm^2$ by 20 pulses of the pulse width 1.2 msec. The author investigated the enamel surface with the sunning electron microscope(SEM) and the surface roughness tester, and measured the shear bond strength between electrolytically etched Ni-Cr-Be alloy casting and composite resin. The obtained results were as follows: 1. The surface roughness of enamel after laser irradiation showed the significant difference level from the energy density $40J/cm^2(P<0.05)$. 2. The mean shear bond strength of etched-metal resin-bonded specimens were $154.23{\pm}33.30kg/cm^2$ at unlased enamel surface and $195.72{\pm}29.56kg/cm^2$ at lased energy density $30J/cm^2$, and showed a significant difference(P<0.05). 8. SEM photographs showed the irregular microcracks and the structural changes of lased enamel surface. 4. SEM photographs of the fracture surface after testing the shear bond strength showed the aspect of interfacial fracture between bonding agent and composite resin at the metal sides.

  • PDF

Glass Ionomer Cement의 접착력(接着力)에 관(關)한 실험적(實驗的) 연구(硏究) (AN EXPERIMENTAL STUDY ON THE BONDING FORCE OF GLASS IONOMER CEMENT)

  • 이명종
    • Restorative Dentistry and Endodontics
    • /
    • 제7권1호
    • /
    • pp.77-83
    • /
    • 1981
  • The purpose of this study was to observe the bonding strength between tooth surface (enamel and dentin) and restorative filling materials which are two composite resins (Clearfil and Concise) and Glass ionomer cement, after etching with 50% phoshoric acid and 37% citric acid. To measure the bonding strength in enamel, the labial surface of upper anterior tooth was cut flatly with using carborundum disk and polished with sand paper disk, and to measure in dentin, the dentin surface was prepared by grinding upper part of posterior tooth horizontally. After washing the tooth surface with water and drying with air blast, the prepared tooth surface was etched. In glass ionomer cement, 50% phosphoric acid and 37% citric acid were used, in Clearfil 40% phosphoric acid was used and in Concise, 50% phosphoric acid and 37% citric acid were used as etchant for 1 minute. After the copper band which is 5 mm in diameter and 5 mm in height was fixed on the prepared surface and each filling material was inserted into the copper band, the hooking loop was inserted into filled material in the copper band before setting to make it easily that the load is applied on the specimen. After all specimens were immersed in water at $37^{\circ}C$ for 1 week, this specimen was placed on the load cell of tensile test apparatus, and specimen was pulled at the cross-head speed of 0.8 mm per minute. The following results were obtained 1) In glass ionomer cement, the bond strength obtained by 37% citric acid was higher than one obtained by 50% phosphoric acid in enamel and dentin surfaces. The bond strength obtained in non-etched surface was much less than one by etchants in enamel and dentin surface. 2) In Clearfil, the bond strength obtained by 40% phosphoric acid was 4 times more than one obtained by non etch ant. 3) In Concise, the bond strength obtained by 50% phosphoric acid was almost same as one obtained by 37% citric acid, and the bond strength obtained by non etch ant was much less than one obtained by etchants.

  • PDF

나노스크래치와 HF 식각을 병용한 보로실리케이트 요/철형 구조체 패턴 제작 기술 (Fabrication Technique of Nano/Micro Pattern with Concave and Convex Structures on the Borosilicate Surface by Using Nanoscratch and HF etching)

  • 윤성원;강충길
    • 한국정밀공학회지
    • /
    • 제21권4호
    • /
    • pp.24-31
    • /
    • 2004
  • The objective of this work is to suggest a mastless pattern fabrication technique using the combination of machining by Nanoindenter(equation omitted) XP and HF wet etching. Sample line patterns were machined on a borosilicate surface by constant load scratch (CLS) of the Nanoindenter(equation omitted) XP with a Berkovich diamond tip, and they were etched in HF solution to investigate chemical characteristics of the machined borosilicate surface. All morphological data of scratch traces were scanned using atomic force microscope (AFM).