• Title/Summary/Keyword: error range

Search Result 2,811, Processing Time 0.035 seconds

A Study of Equipment Accuracy and Test Precision in Dual Energy X-ray Absorptiometry (골밀도검사의 올바른 질 관리에 따른 임상적용과 해석 -이중 에너지 방사선 흡수법을 중심으로-)

  • Dong, Kyung-Rae;Kim, Ho-Sung;Jung, Woon-Kwan
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose : Because there is a difference depending on the environment as for an inspection equipment the important part of bone density scan and the precision/accuracy of a tester, the management of quality must be made systematically. The equipment failure caused by overload effect due to the aged equipment and the increase of a patient was made frequently. Thus, the replacement of equipment and additional purchases of new bonedensity equipment caused a compatibility problem in tracking patients. This study wants to know whether the clinical changes of patient's bonedensity can be accurately and precisely reflected when used it compatiblly like the existing equipment after equipment replacement and expansion. Materials and methods : Two equipments of GE Lunar Prodigy Advance(P1 and P2) and the Phantom HOLOGIC Spine Road(HSP) were used to measure equipment precision. Each device scans 20 times so that precision data was acquired from the phantom(Group 1). The precision of a tester was measured by shooting twice the same patient, every 15 members from each of the target equipment in 120 women(average age 48.78, 20-60 years old)(Group 2). In addition, the measurement of the precision of a tester and the cross-calibration data were made by scanning 20 times in each of the equipment using HSP, based on the data obtained from the management of quality using phantom(ASP) every morning (Group 3). The same patient was shot only once in one equipment alternately to make the measurement of the precision of a tester and the cross-calibration data in 120 women(average age 48.78, 20-60 years old)(Group 4). Results : It is steady equipment according to daily Q.C Data with $0.996\;g/cm^2$, change value(%CV) 0.08. The mean${\pm}$SD and a %CV price are ALP in Group 1(P1 : $1.064{\pm}0.002\;g/cm^2$, $%CV=0.190\;g/cm^2$, P2 : $1.061{\pm}0.003\;g/cm^2$, %CV=0.192). The mean${\pm}$SD and a %CV price are P1 : $1.187{\pm}0.002\;g/cm^2$, $%CV=0.164\;g/cm^2$, P2 : $1.198{\pm}0.002\;g/cm^2$, %CV=0.163 in Group 2. The average error${\pm}$2SD and %CV are P1 - (spine: $0.001{\pm}0.03\;g/cm^2$, %CV=0.94, Femur: $0.001{\pm}0.019\;g/cm^2$, %CV=0.96), P2 - (spine: $0.002{\pm}0.018\;g/cm^2$, %CV=0.55, Femur: $0.001{\pm}0.013\;g/cm^2$, %CV=0.48) in Group 3. The average error${\pm}2SD$, %CV, and r value was spine : $0.006{\pm}0.024\;g/cm^2$, %CV=0.86, r=0.995, Femur: $0{\pm}0.014\;g/cm^2$, %CV=0.54, r=0.998 in Group 4. Conclusion: Both LUNAR ASP CV% and HOLOGIC Spine Phantom are included in the normal range of error of ${\pm}2%$ defined in ISCD. BMD measurement keeps a relatively constant value, so showing excellent repeatability. The Phantom has homogeneous characteristics, but it has limitations to reflect the clinical part including variations in patient's body weight or body fat. As a result, it is believed that quality control using Phantom will be useful to check mis-calibration of the equipment used. A value measured a patient two times with one equipment, and that of double-crossed two equipment are all included within 2SD Value in the Bland - Altman Graph compared results of Group 3 with Group 4. The r value of 0.99 or higher in Linear regression analysis(Regression Analysis) indicated high precision and correlation. Therefore, it revealed that two compatible equipment did not affect in tracking the patients. Regular testing equipment and capabilities of a tester, then appropriate calibration will have to be achieved in order to calculate confidential BMD.

  • PDF

The Effect of Corporate Association on the Perceived Risk of the Product (소비자의 제품 지각 위험에 대한 기업연상과 효과: 지식과 관여의 조절적 역활을 중심으로)

  • Cho, Hyun-Chul;Kang, Suk-Hou;Kim, Jin-Yong
    • Journal of Global Scholars of Marketing Science
    • /
    • v.18 no.4
    • /
    • pp.1-32
    • /
    • 2008
  • Brown and Dacin (1997) have investigated the relationship between corporate associations and product evaluations. Their study focused on the effects of associations with a company's corporate ability (CA) and its corporate social responsibility (CSR) on consumers' product evaluations. Their study has found that both of CA and CSR influenced product evaluation but CA association has a stronger effect than CSR associations. Brown and Dacin (1997) have, however, claimed that there are few researches on how corporate association impacts product responses. Accordingly, some of researchers have found the variables to moderate or to mediate the relationship between the corporate association and the product responses. In particular, there has been existed a few of studies that tested the influence of the reputation on the product-relevant perceived risk, but the effects of two types of the corporate association on the product-relevant perceived risk were not identified so far. The primary goal of this article is to identify and empirically examine some variables to moderate the effects of CA association and CSR association on the perceived risk of the product. In this articles, we take the concept of the corporate associations that Brown and Dacin (1997) had proposed. CA association is those association related to the company's expertise in producing and delivering its outputs and CSR association reflected the organization's status and activities with respect to its perceived societal obligations. Also, this study defines the risk, which is the uncertainty or loss of the product and corporate that consumers have taken in a particular purchase decision or after having purchased. The risk is classified into product-relevant performance risk and financial risk. Performance risk is the possibility or the consequence of a product not functioning at some expected level and financial risk is the monetary loss one perceives to be incurring if a product does not function at some expected level. In relation to consumer's knowledge, expert consumers have much of the experiences or knowledge of the product in consumer position and novice consumers does not. The model tested in this article are shown in Figure 1. The model indicates that both of CA association and CSR association influence on performance risk and financial risk. In addition, the effects of CA and CSR are moderated by product category knowledge (product knowledge) and product category involvement (product involvement). In this study, the relationships between the corporate association and product-relevant perceived risk are hypothesized as the following form. For example, Hypothesis 1a($H_{1a}$) is represented that CA association has a positive influence on the performance risk of consumer. Also, the hypotheses that identified some variables to moderate the effects of two types of corporate association on the perceived risk of the product are laid down. One of the hypotheses of the interaction effect is Hypothesis 3a($H_{3a}$), it is described that consumer's knowledges of the product moderates the negative relationship between CA association and product-relevant performance risk. A field experiment was conducted in order to examine our model. The company tested was not real but imagined to meet the internal validity. Water purifiers were used for our study. Four scenarios have been developed and described as the imaginary company: Type A with both of superior CA and CSR, Type B with superior CSR and inferior CA, Type C with superior CA and inferior CSR, and Type D with both inferior of CA and CSR. The respondents of this study were classified into four groups. One type of four scenarios (Type A, B, C, or D) in its questionnaire was given to the respondent who filled out questions. Data were collected by means of a self-administered questionnaire to the respondents, chosen in convenience. A total of 300 respondents filled out the questionnaire but 207 were used for further analysis. Table 1 indicates that the scales in this study are reliable because the range of coefficients of Cronbach's $\alpha$ are from 0.85 to 0.92. The composite reliability is in the range of 0,85 to 0,92 and average variance extracted is in 0.72-0.98 range that is higher than the base level of 0.6. As shown in Table 2, the values for CFI, NNFI, root-mean-square error approximation (RMSEA), and standardized root-mean-square residual (SRMR) are acceptably close to the standards suggested by Hu and Bentler (1999):.95 for CFI and NNFI,.06 for RMSEA, and.08 for SRMR. We also tested discriminant validity provided by Fornell and Larcker (1981). As shown in Table 2, we found strong evidence for discriminant validity between each possible pair of latent constructs in all samples. Given that these batteries of overall goodness-of-fit indices were accurate and that the model was developed on theoretical bases, and given the high level of consistency across samples, this enables us to proceed the previously defined scales. We used the moderated hierarchical regression analysis to test the influence of the corporate association(CA and CSR associations) on product-relevant perceived risk(performance and financial risks) and to identify the variables moderating the relationship between the corporate association and product-relevant performance risk. In this study, dependent variables are performance and financial risk. CA and CSR associations are described the independent variables. The moderating variables are product category knowledge and product category involvement. The results are, as expected, found that CA association has statistically a significant influence on the perceived risk of the product, but CSR association does not. Product category knowledge and involvement moderate the relationship between the CA association and the perceived risk of the product. However, the effect of CSR association on the perceived risk of the product is not moderated by the consumers' knowledge and involvement. For this result, it is necessary for a corporate to inform its customers CA association more than CSR association so that they could be felt to be the reduction of the perceived risk. The important theoretical contribution of this research is the meanings that two types of corporate association that Brown and Dacin(1997), and Brown(1998) have proposed replicated the difference of the effects on product evaluation. According to Hunter(2001), it was an important affair to accomplish the validity of a particular study and we had to take about ten studies to deduce a strict study. Next, there is the contribution of the this study to find that the effects of corporate association on the perceived risk of the product are varied by the moderator variables. In particular, the moderating effect of knowledge on the relationship between corporate association and product-relevant perceived risk has not been tested in Korea. In the managerial implications of this research, we suggest the necessity to stress the ability that corporate manufactures the product well(CA association) than the accomplishment of corporate's social obligation(CSR association). This study suffers from various limitations that imply future research directions. The moderating effects of product category knowledge and involvement on the relationship between corporate association and perceived risk need to be replicated. Next, future research could explore whether the mediated effects of the perceived risk has the relationship between corporate association and consumer's product purchase. In addition, to ensure the external validity of the study will be needed to use realistic company, not artificial.

  • PDF

Analysis of Oceanic Current Maps of the East Sea in the Secondary School Science Textbooks (중등 과학 교과서의 동해 해류도 분석)

  • Park, Kyung-Ae;Park, Ji-Eun;Seo, Kang-Sun;Choi, Byoung-Ju;Byun, Do-Seong
    • Journal of the Korean earth science society
    • /
    • v.32 no.7
    • /
    • pp.832-859
    • /
    • 2011
  • The importance of scientific education on accurate oceanic currents and circulation has been increasingly addressed because the currents have played a significant role in climate change and global energy balance. The objectives of this study are to analyze errors of the oceanic current maps in the textbooks, to discuss a variety of error sources, to suggest how to produce a unified oceanic current map of the East Sea for the students. Twenty-seven textbooks based on the 7th National Curriculum were analyzed and quantitatively investigated on the characteristics of the current maps by comparing with both the previous literature and up-to-date scientific knowledge. All the maps in the textbooks with different mappings were converted to digitalized image data with Mercator mapping using geolocation information. Detailed analysis were performed to investigate the patterns of the Tsushima Warm Current (TWC) in the Korea Strait, to examine how closely the nearshore branch of the TWC flows along the Japanese coast, to scrutinize the features of the offshore branch of the TWC south of the subpolar front in the East Sea, to quantitatively investigate the northern range of the northward-propagating East Korea Warm Current and its latitude turning to the east, and lastly to examine the outflow of the TWC near the Tsugaru Strait and the Soya Strait. In addition, the origins, southern limits, and distances from the coast of the Liman Current and the North Korea Cold Current were analyzed. Other erroneous expressions of the currents in the textbooks were presented. These analyses revealed the problems in the present current maps of the textbooks, which might lead the students to misconception. This study also addressed a necessity in a bridge between scientists with up-to-date scientific results and educators who needed educational materials.

Determination of $^{14}C$ in Environmental Samples Using $CO_2$ Absorption Method ($Co_2$ 흡수법에 의한 환경시료중 $^{14}C$ 정량)

  • Lee, Sang-Kuk;Kim, Chang-Kyu;Kim, Cheol-Su;Kim, Yong-Jae;Rho, Byung-Hwan,
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.1
    • /
    • pp.35-46
    • /
    • 1997
  • A simple and precise method of $^{14}C$ was developed to analyze $^{14}C$ in the environment samples using a commercially available $^{14}CO_2$ absorbent and a liquid scintillation counter. An air sampler and a combustion system were developed to collect HTO and $^{14}CO_2$ in the air and the biological samples simultaneously. The collection yield of $^{14}CO_2$ by the air sampler was in the range of 73-89% . The yield of the combustion system was 97%. In preparing samples for counting, the optimum ratio of $CO_2$ absorbent to the scintillator for mixing was 1:1. No variation of the specific activity of $^{14}C$ in the counting sample was observed up to 70 days after preparation of the samples. The detection limit for$^{14}C$ was 0.025 Bq/gC, which is the level applicable to the natural level of $^{14}C$. The analytical result of $^{14}C$ obtained by the present method were within ${\pm}6%$ of the relative error from the one by the benzene synthesis. The specific activity of $^{14}C$ in the air collected at Taejon during the period of October 1996 ranged from 0.26 to 0.27 Bq/gC. The specific activity of $^{14}C$ in the air collected at 1km from the Wolsong nuclear power plant a 679 MWe PHWR, was $0.54{\pm}0.03$ Bq/gC. The ranges of specific activities of $^{14}C$ in the pine needles and the vegetations from the areas around the Wolsong nuclear power plant were 0.56-0.67 Bq/gC and 0.23-1.41 Bq/gC, respectively.

  • PDF

Performance Test of Portable Hand-Held HPGe Detector Prototype for Safeguard Inspection (안전조치 사찰을 위한 휴대형 HPGe 검출기 시제품 성능평가 실험)

  • Kwak, Sung-Woo;Ahn, Gil Hoon;Park, Iljin;Ham, Young Soo;Dreyer, Jonathan
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.1
    • /
    • pp.54-60
    • /
    • 2014
  • IAEA has employed various types of radiation detectors - HPGe, NaI, CZT - for accountancy of nuclear material. Among them, HPGe has been mainly used in verification activities required for high accuracy. Due to its essential cooling component(a liquid-nitrogen cooling or a mechanical cooling system), it is large and heavy and needs long cooling time before use. New hand-held portable HPGe has been developed to address such problems. This paper deals with results of performance evaluation test of the new hand-held portable HPGe prototype which was used during IAEA's inspection activities. Radioactive spectra obtained with the new portable HPGe showed different characteristics depending on types and enrichments of nuclear materials inspected. Also, Gamma-rays from daughter radioisotopes in the decay series of $^{235}U$ and $^{238}U$ and characteristic x-rays from uranium were able to be remarkably separated from other peaks in the spectra. A relative error of enrichment measured by the new portable HPGe was in the range of 9 to 27%. The enrichment measurement results didn't meet partially requirement of IAEA because of a small size of a radiation sensing material. This problem might be solved through a further study. This paper discusses how to determine enrichment of nuclear material as well as how to apply the new hand-held portable HPGe to safeguard inspection. There have been few papers to deal with IAEA inspection activity in Korea to verify accountancy of nuclear material in national nuclear facilities. This paper would contribute to analyzing results of safeguards inspection. Also, it is expected that things discussed about further improvement of a radiation detector would make contribution to development of a radiation detector in the related field.

Development of Empirical Fragility Function for High-speed Railway System Using 2004 Niigata Earthquake Case History (2004 니가타 지진 사례 분석을 통한 고속철도 시스템의 지진 취약도 곡선 개발)

  • Yang, Seunghoon;Kwak, Dongyoup
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.11
    • /
    • pp.111-119
    • /
    • 2019
  • The high-speed railway system is mainly composed of tunnel, bridge, and viaduct to meet the straightness needed for keeping the high speed up to 400 km/s. Seismic fragility for the high-speed railway infrastructure can be assessed as two ways: one way is studying each element of infrastructure analytically or numerically, but it requires lots of research efforts due to wide range of railway system. On the other hand, empirical method can be used to access the fragility of an entire system efficiently, which requires case history data. In this study, we collect the 2004 MW 6.6 Niigata earthquake case history data to develop empirical seismic fragility function for a railway system. Five types of intensity measures (IMs) and damage levels are assigned to all segments of target system for which the unit length is 200 m. From statistical analysis, probability of exceedance for a certain damage level (DL) is calculated as a function of IM. For those probability data points, log-normal CDF is fitted using MLE method, which forms fragility function for each damage level of exceedance. Evaluating fragility functions calculated, we observe that T=3.0 spectral acceleration (SAT3.0) is superior to other IMs, which has lower standard deviation of log-normal CDF and low error of the fit. This indicates that long-period ground motion has more impacts on railway infrastructure system such as tunnel and bridge. It is observed that when SAT3.0 = 0.1 g, P(DL>1) = 2%, and SAT3.0 = 0.2 g, P(DL>1) = 23.9%.

Performance Evaluation of an Electrometer for Quality Control and Dosimetry in Radiation Therapy (방사선 치료의 정도관리 및 선량측정에 이용되는 전리계의 성능평가)

  • Kim, Chang-Seon;Kim, Chul-Yong;Park, Myung-Sun
    • Progress in Medical Physics
    • /
    • v.11 no.2
    • /
    • pp.123-130
    • /
    • 2000
  • The performance of an electrometer directly affects on the accuracy and precision in radiation dosimetry. This study is to list of the quality control for maintaining performance and to perform evaluation tests of an electrometer. Performance tests selected include proper polarizing voltages, warm-up and equalization time, leakages, long-term stability, linearity, and effect of ambient conditions. An electrometer connected with a rigid stem ionization chamber was evaluated with a Strontium-90 check device. Bias voltage was measured directly on the input socket. Equalization time is the time required for reaching threshold of charged state after the power is on or the bias voltage is changed. Pre- and post-signal leakages are defined as the accumulation of signal with no exposure and after exposure, respectively. Over three months period, the electrometer's long-term stability was measured by comparison of the temperature-pressure corrected readings. Linearity was expressed as the deviation of readings from multiple short exposures from one continuous exposure. Effect of ambient conditions was expressed as the zero drift of the electrometer over 17-34$^{\circ}C$ temperature ranges. For two nominal values, 300 and 500 volts, measured voltages were lower by 2.5 and 5.8%, respectively. The warm-up time, 20 minutes, was longer than the lamp time by 9 minutes and the equalization time was less than 1 minute. Without exposure, the zero-drift was 0.002 scale-unit in 15 minutes and the leakage after 10 minutes exposure was minimal. The IQ-4 was stable over 99.4% for three-month periods. Deviation from the linearity was 0.9% for measurement scale, 0.000-9.991. Over 17-34$^{\circ}C$ temperature range, the zero-drift was minimal, less than 0.2%. For a clinically-used electrometer, a list for the basic peformance evaluations is proposed. By running this program, the measurement error using an electrometer can be reduced and in turn the improvement in accuracy and precision of radiation dosimetry can be achieved.

  • PDF

Analysis of Sensitivity to Prediction of Particulate Matters and Related Meteorological Fields Using the WRF-Chem Model during Asian Dust Episode Days (황사 발생 기간 동안 WRF-Chem 모델을 이용한 미세먼지 예측과 관련 기상장에 대한 민감도 분석)

  • Moon, Yun Seob;Koo, Youn Seo;Jung, Ok Jin
    • Journal of the Korean earth science society
    • /
    • v.35 no.1
    • /
    • pp.1-18
    • /
    • 2014
  • The purpose of this study was to analyze the sensitivity of meteorological fields and the variation of concentration of particulate matters (PMs) due to aerosol schemes and dust options within the WRF-Chem model to estimate Asian dusts affected on 29 May 2008 in the Korean peninsula. The anthropogenic emissions within the model were adopted by the $0.5^{\circ}{\pm}0.5^{\circ}$ RETRO of the global emissions, and the photolysis option was by Fast-J photolysis. Also, three scenarios such as the RADM2 chemical mechanism and MADE/SORGAM aerosol, the MOSAIC 8 section aerosol, and the GOCART dust erosion were simulated for calculating Asian dust emissions. As a result, the scenario of the RADM2 chemical mechanism & MADE/SORGAM aerosol depicted higher concentration than the others' in both Asian dusts and the background concentration of PMs. By comparing of the daily mean of PM10 measured at each air quality monitoring site in Seoul with the scenario results, the correlation coefficient was 0.67, and the root mean square error was $44{\mu}gm^{-3}$. In addition, the air temperature, the wind speed, the planetary boundary layer height, and the outgoing long-wave radiation were simulated under conditions of no chemical option with these three scenarios within the WRF or WRF-Chem model. Both the spatial distributions of the PBL height and the wind speed of u component among the meteorological factors were similar to those of the Asia dusts in range of 1,800-3,000 m and $2-16ms^{-1}$, respectively. And, it was shown that both scenarios of the RADM2 chemical mechanism and MADE/SORGAM aerosol and the GOCART dust erosion were interacted on-line between meteorological factors and Asian dusts or aerosols within the model because the outgoing long-wave radiation was changed to lower than the others.

An Adjustment of Cloud Factors for Continuity and Consistency of Insolation Estimations between GOES-9 and MTSAT-1R (GOES-9과 MTSAT-1R 위성 간의 일사량 산출의 연속성과 일관성 확보를 위한 구름 감쇠 계수의 조정)

  • Kim, In-Hwan;Han, Kyung-Soo;Yeom, Jong-Min
    • Korean Journal of Remote Sensing
    • /
    • v.28 no.1
    • /
    • pp.69-77
    • /
    • 2012
  • Surface insolation is one of the major indicators for climate research over the Earth system. For the climate research, long-term data and wide range of spatial coverage from the data observed by two or more of satellites of the same orbit are needed. It is important to improve the continuity and consistency of the derived products, such as surface insolation, from different satellites. In this study, surface insolations based on Geostationary Operational Environmental Satellite (GOES-9) and Multi-functional Transport Satellites (MTSAT-1R) were compared during overlap period using physical model of insolation to find ways to improve the consistency and continuity between two satellites through comparison of each channel data and ground observation data. The thermal infrared brightness temperature of two satellites show a relatively good agreement between two satellites : rootmean square error (RMSE)=5.595 Kelvin; Bias=2.065 Kelvin. Whereas, visible channels shown a quite different values, but it distributed similar tendency. And the surface insolations from two satellites are different from the ground observation data. To improve the quality of retrieved insolations, we have reproduced surface insolation of each satellite through adjustment of the Cloud Factor, and the Cloud Factor for GOES-9 satellite is modified based on the analysis result of difference channel data. As a result, the insolations estimated from GOES-9 for cloudy conditions show good agreement with MTSAT-1R and ground observation : RMSE=$83.439W\;m^{-2}$ Bias=$27.296W\;m^{-2}$. The result improved accuracy confirms that the modification of Cloud Factor for GOES-9 can improve the continuity and consistency of the insolations derived from two or more satellites.

Effect of Night and Daytime Temperatures on Growth and Yield of Paprika 'Fiesta' and 'Jubilee' (${\cdot}$야 온도가 착색단고추의 생육 및 수량에 미치는 영향)

  • Choi Young Hah;Kwon Joon Kook;Lee Jae Han;Kang Nam Jun;Cho Myeong Whan;Kang Jum Soon
    • Journal of Bio-Environment Control
    • /
    • v.13 no.4
    • /
    • pp.226-232
    • /
    • 2004
  • This experiment was conducted to investigate the effect of night and daytime temperatures on growth and yield of paprika 'Fiesta' and 'Jubilee' under soil culture experiment in the vinyl houses during the 2003 and 2004 season. Total fruit yield was greater in 'Fiesta' than 'Jubilee' Marketable yield was not different between two cultivars, due to lower $\%$ marketable fruits in 'Fiesta'. mean Fruit weight was not different between two cultivars. Difference of yield between cultivars was due to fruit number, harves time and root condition. It was caused by cracked fruits to decrease $\%$ marketable fruits. Total yield was greater in nighttime temperature of $18^{\circ}C\;than\;15^{\circ}C$ and marketable yield was considerably greater because of $\%$ marketable fruits was higher. Mean fruit weight was slightly greater in nighttime temperature of $15^{\circ}C\;than\;18^{\circ}C$. Difference of fruit yield in treatments of nighttime temperature was due to fruit number and harvest time. There was not significant difference of yield between daytime temperature of $28^{\circ}C\;and\;31^{\circ}C$, but in $34^{\circ}C$, total and marketable yields were the least and mean fruit weight was the smallest because of decreased $CO_2$ concentration in the house, accerated vegetative growth, and the least chlorophyll content. There were no significant difference in photosynthetic rate, transpiration rate, maximal photochemical efficiency and antioxidant enzyme activities of all temperature treatments in this experiment. However it was clear that a little difference in error range of these results affects the source of crops in any case. It was not acknowledged that compensation effect by high temperature in daytime to the low temperature treatment in nighttime.