• Title/Summary/Keyword: error range

Search Result 2,816, Processing Time 0.033 seconds

Accuracy Evaluation of Pre- and Post-treatment Setup Errors in CBCT-based Stereotactic Body Radiation Therapy (SBRT) for Lung Tumor (CBCT 기반 폐 종양 정위 신체 방사선 요법(SBRT)에서 치료 전·후 set up 에러의 정확도 평가)

  • Jang, Eun-Sung;Choi, Ji-Hoon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.861-867
    • /
    • 2021
  • Since SBRT takes up to 1 hour from 30 minutes to treatment fraction once or three to five times, there is a possibility of setup error during treatment. To reduce these set-up errors and give accurate doses, we intend to evaluate the usefulness of pre-treatment and post-treatment error values by imaging CBCT again to determine postural movement due to pre-treatment coordinate values using pre-treatment CBCT. On average, the range of systematic errors was 0.032 to 0.17 on the X and Y,Z axes, confirming that there was very little change in movement even after treatment. Tumor centripetal changes (±SD) due to respiratory tuning were 0.11 (±0.12) cm, 0.27 (±0.15) cm, and 0.21 cm (±0.31 cm) in the X, Y and Z directions. The tumor edges ±SD were 0.21 (±0.18) cm, 0.30 (±0.23) cm, and 0.19 cm (±0.26) cm in the X, Y and Z directions. The (±SD) of tumor-corrected displacements were 0.03 (±0.16) cm, 0.05 (±0.26) cm, and 0.02 (±0.23) cm in RL, AP, and SI directions, respectively. The range of the 3D vector value was 0.11 to 0-.18 cm on average when comparing pre-treatment and CBCT, and it was confirmed that the corrected set-up error was within 0.3 cm. Therefore, it was confirmed that there were some changes in values depending on some older patients, condition on the day of treatment, and body type, but they were within the significance range.

Antenna Test Range for Telecommunication Satellite (통신위성용 안테나 테스트 레인지)

  • Lim, Seong-Bin;Kim, Tae-Youn;Choi, Seok-Won;Sim, Eun-Sup
    • Aerospace Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.52-59
    • /
    • 2007
  • Telecommunication satellite consists of a bus system and an RF payload system with high efficiency and high gain reflector antennas. Antenna measurement and also RF system performance (antenna under test, payload and satellite level) have to be evaluated enough before launching in the far-field range or equivalent test range. Basically far-field range is required in a range from two hundred meters to several kilo meters, and it is highly constrained to the externa1 environment, like the RF and the whether environment So the compact antenna test range is developed and used efficiently without external environments as in-door facility. This paper describes the configuration of the compact antenna test range, the range error, and the physical concept of the plane wave illumination Also, it provides a overall design of the anechoic chamber and range parameter values to accommodate the precision measurements in antenna test range.

  • PDF

A research on the sychronized clock pulse for the measurement of physical function. (안정된 동기시신호발생을 이용한 인체 기능의 측정에 관한 연구)

  • Lee, Haing-Se;Lee, Sang-Hyeok;Kim, Yong-Deuk
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.13 no.5
    • /
    • pp.9-16
    • /
    • 1976
  • This paper deals with a method of measuring the temperature, purse, and pressure of a human body The temperature controlled oscillator was designed with a thermistor as a temperature measuring part The error in temperature was less than $\pm$0.05$^{\circ}C$ in the range of the temperature of a human body.

  • PDF

Development of the Computer Vision based Continuous 3-D Feature Extraction System via Laser Structured Lighting (레이저 구조광을 이용한 3차원 컴퓨터 시각 형상정보 연속 측정 시스템 개발)

  • Im, D. H.;Hwang, H.
    • Journal of Biosystems Engineering
    • /
    • v.24 no.2
    • /
    • pp.159-166
    • /
    • 1999
  • A system to extract continuously the real 3-D geometric fearture information from 2-D image of an object, which is fed randomly via conveyor has been developed. Two sets of structured laser lightings were utilized. And the laser structured light projection image was acquired using the camera from the signal of the photo-sensor mounted on the conveyor. Camera coordinate calibration matrix was obtained, which transforms 2-D image coordinate information into 3-D world space coordinate using known 6 points. The maximum error after calibration showed 1.5 mm within the height range of 103mm. The correlation equation between the shift amount of the laser light and the height was generated. Height information estimated after correlation showed the maximum error of 0.4mm within the height range of 103mm. An interactive 3-D geometric feature extracting software was developed using Microsoft Visual C++ 4.0 under Windows system environment. Extracted 3-D geometric feature information was reconstructed into 3-D surface using MATLAB.

  • PDF

Development of Automatic Evaluation Equipment for Burden of Instrument Transformer using Resistor Simulator (저항기를 이용한 계기용 변성기 부담 자동 평가 장치 개발)

  • Lee, Young Seob;Jung, Jae Kap
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.4
    • /
    • pp.589-595
    • /
    • 2014
  • The error of instrument transformers is measured by connecting the external burden with the secondary terminal of the instrument transformers. Because the error of transformer is affected by the apparent power and power factor of the external burden, an accurate measurement of burden is important for transformer evaluation. We have developed the burden evaluation equipment for both potential transformer and current transformer by employing the series resistor in the range of $20m{\Omega}{\sim}5{\Omega}$ and the parallel resistor in the range of $1M{\Omega}{\sim}500{\Omega}$, respectively, together with visual basic program. We could reduce testing time more than 5 times by employing method developed in this study, compared with that developed in past. This method shows more better reliability by analyzing the evaluation results and fitting graphs of burden measurements. The test results of the developed system is compared with those obtained in the power meter analyzer to verify the validity.

Observation Likelihood Function Design and Slippage Error Compensation Scheme for Indoor Mobile Robots (실내용 이동로봇을 위한 위치추정 관측모델 설계 및 미끄러짐 오차 보상 기법 개발)

  • Moon, Chang-Bae;Kim, Kyoung-Rok;Song, Jae-Bok;Chung, Woo-Jin
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.11
    • /
    • pp.1092-1098
    • /
    • 2007
  • A mobile robot localization problem can be classified into following three sub-problems as an observation likelihood model, a motion model and a filtering technique. So far, we have developed the range sensor based, integrated localization scheme, which can be used in human-coexisting real environment such as a science museum and office buildings. From those experiences, we found out that there are several significant issues to be solved. In this paper, we focus on three key issues, and then illustrate our solutions to the presented problems. Three issues are listed as follows: (1) Investigation of design requirements of a desirable observation likelihood model, and performance analysis of our design (2) Performance evaluation of the localization result by computing the matching error (3) The semi-global localization scheme to deal with localization failure due to abrupt wheel slippage In this paper, we show the significance of each concept, developed solutions and the experimental results. Experiments were carried out in a typical modern building environment, and the results clearly show that the proposed solutions are useful to develop practical and integrated localization schemes.

Design of CMOS Optical Link Receiver for FTTH (FTTH용 CMOS Optical Link Receiver의 설계)

  • Kim Kyu-Chull
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.1
    • /
    • pp.47-52
    • /
    • 2004
  • This paper presents a CMOS optical receiver design featuring wide input dynamic range and low bit error rate suitable for FTTH application. We achieved 60dB input dynamic range for up to 100Mbps by controlling the PMOS feedback resistance of transimpedance preamplifier according to its output signal level. Auto-bias circuit is designed in current mirror configuration to minimize duty error. Circuit simulation has been performed using 2-poly, 3-metal, 0.6um CMOS process parameters. The designed receiver consumes less than 130mW at 100Mbps with 5V power supply.

Measurement of Complex Modulus of Acoustic Materials by Using Transfer Function Method

  • Kim, Hyun-Sil;Kim, Jae-Seung;Kang, Hyun-Joo;Kim, Bong-Ki;Kim, Sang-Ryul
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.1E
    • /
    • pp.12-17
    • /
    • 2002
  • Two improvements are discussed in measurement of the complex Young's modulus of the acoustic materials by using the transfer function method. It is found that the accelerometer misalignment might result in the severe measurement error, particularly in high frequency range. The supporting structure is modified to attach the upper and lower accelerometers along the vertical axis. Secondly, the method fur solving the equation associated with wave model is described. The solution of the lumped mass-spring model is chosen as the starting value for low frequency range, while in the mid and high frequency, the solution to the previous frequency step is used as the initial values. Measurements are done for hard and soft rubber specimens. It is shown that the erroneous peaks in the transfer function, due to the measurement error, cause highly incorrect Young's modulus and loss factors.

RF Transceiver Implementation to Evaluate the Requirements of 3G W-CDMA User Equipment (3G W-CDMA UE 요구사항 평가를 위한 RF 트랜시버 구현)

  • Il-Kyoo Lee;Seung-Hyeub Oh
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.2
    • /
    • pp.148-156
    • /
    • 2003
  • This paper describes the RF performance issues of UE for W-CDMA system based on 3 GPP specifications. The parameters of transmitter and receiver are derived from the viewpoint of RF performance. In order for UE to achieve high performance, the transceiver performance requirements such as ACLR, EVM, Peak Code Domain Error, spectrum emission mask, frequency error stability and TX power control dynamic range for transmitter and reference sensitivity level, blocking characteristics, noise figure, ACS, AGC dynamic range for receiver are considered. On the basis of the required parameters, the UE RF transceiver is implemented and then the evaluation of RF performance is accomplished through practical test scenarios.

Methodology of System Alignment using Angular Error Compensation Among Multi-Axes (다중 좌표계간 각도오차 보정을 통한 체계정렬 기법)

  • Ha, Jong-Soo;Lee, Eui-Hyuk;Lee, Hyun-Ah;Park, Gyu-Churl;Cho, Kyu-Gong
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.17 no.3
    • /
    • pp.342-349
    • /
    • 2014
  • MRDS is a short range missile/rocket defense system which protects a main battle tank(MBT) from threats in a short range. It is composed of 2 radars, 2 infrared trackers(IRTs), 1 fire control computer(FCC), 2 launchers and countermeasures. To guarantee the performance of the MRDS, these components have to be mounted on the vehicle with the known positions and directions and it is required to compensate the alignment errors. In this paper, a system alignment method using angular error compensation is proposed to install its components within a tolerance on the MBT. The test results are presented to evaluate and verify the effectiveness of the proposed method.