• Title/Summary/Keyword: error generator

Search Result 360, Processing Time 0.035 seconds

Phase Offset Enumeration Method with Error Detection and Its Application to Synchronization of PN Sequences

  • Song Young-Joan
    • Journal of electromagnetic engineering and science
    • /
    • v.5 no.1
    • /
    • pp.26-30
    • /
    • 2005
  • It is important to know phase offsets of PN(Pseudo Noise) sequences in spread spectrum communications since the acquisition is equivalent to making a phase offset between a receiving PN sequence and a PN sequence of local PN generator be identical. In this paper, a phase offset enumeration method for PN sequences with error detection, and its application to the synchronization are proposed. The phase offset enumeration for an n-tuple PN sequence and its error detection are performed when one period of the sequence is received. Once the phase offset of the receiving sequence is calculated, we can easily accomplish the synchronization by initializing shift registers of a local PN generator according to the phase offset value. The mean acquisition time performance of the proposed scheme was derived analytically. Since this synchronization scheme can be realized by using simple circuit and acquires very rapid acquisition in high SNR but shows performance degradation in low SNR, it can be especially useful in indoor and office environments.

Development of Error-Corrector Control Algorithm for Automatic Error Detection and Correction on Space Memory Modules (우주용 메모리의 자동 오류극복을 위한 오류 정정기 제어 알고리즘 개발)

  • Kwak, Seong-Woo;Yang, Jung-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.5
    • /
    • pp.1036-1042
    • /
    • 2011
  • This paper presents an algorithm that conducts automatic memory scrubbing operated by dedicated hardwares. The proposed algorithm is designed so that it can scrub entire memory in a given scrub period, while minimally affecting the execution of flight softwares. The scrub controller is constructed in a form of state machines, which have two execution modes - normal mode and burst mode. The deadline event generator and period tick generator are designed in a separate way to support the behavior of the scrub controller. The proposed controller is implemented in VHDL code to validate its applicability. A simple version of the controller is also applied to mass memory modules used in STSAT-3.

A 9-Rule Fuzzy Logic Controller of the Nuclear Steam Generator (핵증기 발생기의 9룰 퍼지논리 제어기)

  • Lee, Jae-Young;No, Hee-Cheon
    • Nuclear Engineering and Technology
    • /
    • v.25 no.3
    • /
    • pp.371-380
    • /
    • 1993
  • A model free controller utilizing a set of linguistic fuzzy logic of the human operator's experience is developed to control the steam generator water level in a pressurized water reactor. Only 9 rules for control action are generated from the inputs of water level error and mass flow error implicitly representing the time variation of the collapsed water level. The bell type membership functions of the premise side and the result side are tuned by the sensitivity study. This compact fuzzy logic controller shows a robust control during transient and no offset error and oscillation during steady state operation. For a multi-ramp power increase from start-up to full power, the proposed controller shows good performance for the entire range.

  • PDF

Design of Postdistortion Linearizer using Complex Envelope Transfer Characteristics of Power Amplifier (전력 증폭기의 복소 포락선 전달특성을 이용한 Postdistortion 방식의 선형화기의 설계)

  • 한재희;이덕희;남상욱;남상욱;임종식
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.7
    • /
    • pp.1086-1093
    • /
    • 2001
  • A new linearization technique for RF high-power amplifiers(HPAs) using n-th order error signal generator (ESGn) is proposed. The n-th order ESG generates an error signal based on the complex envelope transfer characteristics of the HPA, which is combined at the output of the HPA. Therefore, the higher-order nonlinearlities are not affected by the ESG$\_$n/ and the stability of the linearized system is guaranteed due to the inherent open-loop configuration. Moreover, the output delay loss can be avoided, because the error signal is generated with the input signal of the HPA. The IMD(intermodulation distortion) improvement obtained applying the ESG$\_$7/ to 5 W class A HPA in cellular band demonstrates the feasibility of the proposed postdistortion system.

  • PDF

Comparison of the first and the second order eigenvalue sensitivity coefficients affected by generator modeling (발전기 모델링 정도에 의한 고유치 일차${\cdot}$이차 감도계수 비교)

  • Kim Deok Young
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.345-347
    • /
    • 2004
  • In small signal stability analysis of power systems, eigenvalue analysis is the most useful method and the detailed modeling of generator has an important effect to the eigenvalues. Generator full model is used for precise dynamic analysis of generators and controllers while two-axis model is used for multi-machine systems because of the reduced order of the state matrix. Also, the eigenvalue sensitivity coefficients are used for optimizing controller parameters to improve system stability. This paper compare the first and second order eigenvalue sensitivity coefficients of controllers using generator full model with those of two-axis model. As a result of an example, the estimated eigenvalues using the first and the second eigenvalue sensitivity coefficients using generator full model is very close to those of state matrix. Also the error ratios throughout a wide range of controller parameters is less than $1\%$.

  • PDF

Analysis of the first order eigenvalue sensitivity affected by generator model (발전기 모델링 정도에 의한 고유치 감도계수에 미치는 영향해석)

  • Cho, Eon-Jung;Lee, Kun-Jae;Kim, Deok-Young
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.119-121
    • /
    • 2003
  • In small signal stability analysis of power systems, eigenvalue analysis is the most useful method and the detailed modeling of generator gives an important effect to the eigenvalues. Generator full model is used for precise dynamic analysis of generators and controllers while two-axis model is used for multimachine systems because of the reduced order of the state matrix. Also, the eigenvalue sensitivity coefficients are used for optimization of controller parameters to improve system stability. This paper compare the first order eigenvalue sensitivity coefficients of controllers in case of generator full model with those of two-axis model. As a result of an example the estimated eigenvalues using sensitivity coefficients in case of generator full model is very close to those of state matrix within 1% error ratios.

  • PDF

FPGA Implementation of BCH Encoder to change code rate (부호율 변경이 가능한 BCH Ecoder의 FPGA구현)

  • Jegal, Dong;Byon, Kun-sik
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.485-488
    • /
    • 2009
  • The class of BCH codes is a large class of error correction codes. HDL implementation of BCH code generator to change code rate. and used System Generator, and implemented hardware to FPGA. Loaded bit stream to a FPGA board in order to verify this design to Hardware co-simulation from these results. Also, compared as investigated the maximum action frequency through timing analysis and resource of logic in order to evaluate performance of BCH code generator.

  • PDF

Design and Applications of a Generalized Software-Based GNSS IF Signal Generator

  • Lim, Deok-Won;Park, Chan-Sik;Lee, Sang-Jeong
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.2
    • /
    • pp.211-215
    • /
    • 2006
  • In this paper, design and applications of a generalized, versatile and customizable IF signal generator that can model the modernized GPS and Galileo signal is given. It generates IF sampled data that can be directly used by a software receiver. Entire constellation of satellites which is independent of satellite-user geometry is easily determined using a real or simulated ephemeris data. Since the IF center frequency, sampling frequency and quantization bit number are user location dependent parameters, their effects are also considered in IF signal generator. The generalized IF signal generator will be very well suited for the development phase of a software receiver due to its versatility. The full access to the sampling frequency, front-end filter definition and ADC parameters also offers a great opportunity for cost-effective analysis of tracking loops and error mitigation techniques at the receiver level. Interference sources can be easily added to the generator to simulate specific environments. This software IF signal generator can also be used to feed a multi-frequency multi-system software receiver for the prototyping of a combined GPS/Galileo receiver. The test result using the generated signals and a real software receiver shows the effectiveness of the implemented IF signal generator.

  • PDF

Dynamic Reserve Estimating Method with Consideration of Uncertainties in Supply and Demand (수요와 공급의 불확실성을 고려한 시간대별 순동예비력 산정 방안)

  • Kwon, Kyung-Bin;Park, Hyeon-Gon;Lyu, Jae-Kun;Kim, Yu-Chang;Park, Jong-Keun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.11
    • /
    • pp.1495-1504
    • /
    • 2013
  • Renewable energy integration and increased system complexities make system operator maintain supply and demand balance harder than before. To keep the grid frequency in a stable range, an appropriate spinning reserve margin should be procured with consideration of ever-changing system situation, such as demand, wind power output and generator failure. This paper propose a novel concept of dynamic reserve, which arrange different spinning reserve margin depending on time. To investigate the effectiveness of the proposed dynamic reserve, we developed a new short-term reliability criterion that estimates the probability of a spinning reserve shortage events, thus indicating grid frequency stability. Uncertainties of demand forecast error, wind generation forecast error and generator failure have been modeled in probabilistic terms, and the proposed spinning reserve has been applied to generation scheduling. This approach has been tested on the modified IEEE 118-bus system with a wind farm. The results show that the required spinning reserve margin changes depending on the system situation of demand, wind generation and generator failure. Moreover the proposed approach could be utilized even in case of system configuration change, such as wind generation extension.

Fabrication of a Multiplexing Sensor Probe for Measuring the Blade Deflection of a Wind Power Generator (풍력발전기 블레이드 처짐 측정을 위한 다중화 센서 탐촉자 설계 제작)

  • Kim, Ji-Dea;Lee, Dong-Ju
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.2
    • /
    • pp.178-185
    • /
    • 2014
  • This paper describes a fabrication multiplexing sensor probe that employs a fiber Bragg grating(FBG) based on multiple measurements to determine the blade deflection of a wind power generator the reliability analysis of this probe is also presented. To diminish the temperature sensitivity of the FBG sensor, we form multiple CFRPs onto the upper and lower layers of the FBG and package it with an epoxy resin. As a result, the depth of the CFRP is 1mm, and the temperature sensitivity is $2.39pm/^{\circ}C$. We construct a sensor network utilizing the fabricated sensor with a blade beam model. As the number of pendulums is increased on the fore-end of the beam, the strain value is measured. The strain variation is calculated from the measurement of the load on the blade beam model by monitoring the strain of the FBG sensor. When the linear equation is applied, the strain error is 0.4% and when the finite difference method is used, the tip deflection error is 3.3%. The displacement error derived from the strain value of the FBG sensor is 4.39%. The calculated result between the measured value of the dead-end of the beam and the strain is less than 2.46% tip distortion error. Therefore, our proposed multiplexing sensor probe is a low-cost and high-reliability solution for a commercial wind power generator.