• Title/Summary/Keyword: equipment deterioration

Search Result 190, Processing Time 0.028 seconds

Evaluation of Deterioration Grade for Remodeling Architectural Facilities in Old Schools (학교건물(學校建物) 건축설비(建築設備)시스템의 노후도(老朽度) 평가(評價) 기준(基準)마련을 위한 기초연구(基礎硏究))

  • Cho, Min-Kwan;Cho, Chang-Geun;Park, Jong-Soo
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.13 no.4
    • /
    • pp.15-23
    • /
    • 2006
  • The purpose of this study is to establish the objective deterioration grades and evaluation criteria of building equipment system of educational facilities available for reasonable maintenance and remodeling of them. For the purpose of it, the actual conditions of building equipment systems of the 148 buildings of 84 middle and high schools in Seoul 20 years after construction are investigated and surveyed through one-on-one interviews and questionnaires. And, deterioration grades of them are estimated by the evaluation criteria which is proposed in this study. As a result of this study, the 10 deterioration grades and the 4 evaluation criteria of the 6 performances of building equipment system, which are heating and cooling, water supply and drainage, hot water supply and electrical power performance, are suggested. And, as a result of the survey, it showed that 24% of the investigated school buildings were estimated C grade which needs partial remodelling, and 51% of the school buildings were estimated D grade which needs extensive remodelling. And, 25% of the school buildings were estimated E grade which needs overall remodelling or alteration of building equipment system.

Implementation of Prediction Program for Deterioration Judgment on Substation Power Systems in Urban Railway (도시철도 전력설비의 노후화 판단을 위한 예측 프로그램 구현)

  • Jung, Ho-Sung;Park, Young;Kang, Hyun-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.6
    • /
    • pp.881-885
    • /
    • 2013
  • In this paper, we present a deterioration judgment model of urban rail power equipment using driving history, the frequency and number of failures. In addition, we have developed a deterioration judgment program based on the derived failure rate. A deterioration judgment model of power equipments on metro system was designed to establish how much environmental factors, such as thermal cycling, humidity, overvoltage and partial discharge. The deterioration rate of the transformers followed the Arrhenius log life versus reciprocal Kelvin temperature (hotspot temperature) relation. The deterioration judgment program is linked to the online condition monitoring system of urban railway system. The deterioration judgment program is based on the user interface it is possible to apply immediately to the urban rail power equipment.

A Case Study of Electricity Usage Monitoring for Deterioration and Economic Analysis of Main Equipment in University Laboratory

  • Park, Jun-Young;Lee, Chun-Kyong;Park, Tae-Keun
    • International conference on construction engineering and project management
    • /
    • 2015.10a
    • /
    • pp.706-707
    • /
    • 2015
  • Our country is aiming at 30% reductions in building energy consumption accounting for 39% of the total energy consumption by 2020[1]. For this purpose, the government is developing and applying the Building Energy Management System (hereinafter, referred to as "BEMS", Smart plug, etc.) while the researches on new renewable energy development. BEMS, which is applied with focus on large buildings, is inducing energy management of the entire building through energy measurement and data management, but considering its economic efficiency, it's very difficult to apply BEMS to small & medium-size buildings. Hereupon, this study intends to implement the case analysis of deterioration and economic efficiency of major equipment in buildings on the basis of electricity consumption which has been measured targeting small & medium-size buildings for a certain period by taking into account that equipment deterioration is a contributor to the increase in energy consumption.

  • PDF

Development of the Corrosion Deterioration Inspection Tool for Transmission Tower Members

  • Woo, Sangkyun;Chu, Inyeop;Youn, Byongdon;Kim, Kijung
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.2
    • /
    • pp.293-298
    • /
    • 2016
  • Recently, interests for maintenance of transmission tower are increasing to extend life of structures and reduce maintenance cost. However, existing classical diagnosis method of corrosion deteriorated degree on the transmission tower steel members, visual inspection, has a problem that error often due to difference of inspector's individual knowledge and experience. In order to solve the problem, this study carried out to develop the corrosion deterioration inspection tool for transmission tower steel members. This tool is composed of camera equipment and computer-aided diagnosis system. We standardized the photographing method by camera equipment to obtain suitable pictures for image processing. Diagnosis system was designed to evaluate automatically degree of corrosion deterioration for member of transmission tower on the basis of the RGB color image processing techniques. It is anticipated that developed the corrosion deterioration inspection tool will be very helpful in decision of optimal maintenance time for transmission tower corrosion.

A Study on Deterioration Evaluation Method by Condition Monitoring and Diagnosis for Aging Oil-immersed Power Transformers (유입식 변압기의 상태진단을 통한 노후도 평가 방법)

  • Chang, Jeong-Ho;Lee, Sung-Hun;Lee, Heung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.2
    • /
    • pp.297-305
    • /
    • 2014
  • Nowadays new water supply projects have been on the decline as the water-power constructions have saturated, which means that the existing power equipment have slowly aged and they require more efforts to maintain the system performance. An effective asset management method of power equipment has become a great necessity from both economical and technical aspects. To be balanced, the asset management should look into all three parts: management, engineering, and information. The purpose of this paper is to study a Risk-Based Maintenance (RBM) matrix method through the deterioration evaluation algorithm for an efficient reliability assessment of oil-immersed power transformers by considering both asset management and technical evaluation. Make use of this result, the equipment will be decided to be replace or repair otherwise on service.

A Case Analysis Study on the Validity Assessment of Safety Inspection Findings for Reconstruction - Focusing on the Building Finish and Equipment Deterioration Sector - (공동주택 재건축 안전진단 적정성 검토 사례분석 연구 - 건축 마감 및 설비노후도 평가 중심으로 -)

  • Jeon, Jun-Seo;Kim, Hong-Seop;Kim, Eun-Young;Choe, Gyeong-Cheol;Lee, Mun-Hwan
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.271-272
    • /
    • 2023
  • In this study, we conducted a case analysis of the building finish and equipment deterioration sector in the validity assessment of safety inspection findings for reconstruction. A total of 21 cases were analyzed to confirm the characteristic of performance score for each subsector. It is confirmed that the average performance score was generally affected by maintenance activity, had regional characteristics.

  • PDF

Study of Deterioration Improvement of Power Fuse (전력퓨즈의 열화현상 개선에 관한 연구)

  • Song, Jae-Ki;Kim, Hwan-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.6
    • /
    • pp.3827-3831
    • /
    • 2014
  • This paper aims to solve the problem deterioration of power fuses. The deterioration of a power fuse is a cause of failure misoperation by a normal current flowing reduplicatively to fuse the element. An extension survey of a load feature rerating power fuse examined the power fuse deterioration removal, the cause of the deterioration of the power fuse, the front-after, and the thermal variation of the inside transformer room electric power equipment. The transformer showed an average improvement of $6[^{\circ}C]$. The temperature of the electrical line showed $7{\sim}8[^{\circ}C]$ improvement. The static condenser and direct reactor was $2{\sim}3[^{\circ}C]$ high-state maintenance the temperature and equipment syntonization relationship. In the subject of study $0.5{\sim}1.0[^{\circ}C]$ stabilizing three phase power fuse temperature differential was. Suggestion in the transformer room environment power equipment between the cause temperature happen elimination to deterioration of power fuse and temperature rise control.

Deterioration Characteristics and an On-Line Diagnostic Equipment for Surge Protective Devices (서지 보호기의 열화 특성과 온라인 진단장치)

  • Park, Kyoung-Soo;Wang, Guoming;Hwang, Seong-Cheol;Kim, Sun-Jae;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.10
    • /
    • pp.635-640
    • /
    • 2016
  • This paper dealt with the deterioration characteristics and an on-line diagnosis equipment for SPDs (surge protective devices). An accelerated aging test was carried out using a $8/20{\mu}s$ standard lightning impulse current to analyze the changes of electrical characteristics and to propose the diagnostic parameters and the criterion for deterioration of ZnO varistor which is the core component of SPDs. Based on the experimental results, an on-line diagnosis equipment for SPD was fabricated, which can measure the total leakage current, reference and clamping voltage. The leakage current measurement circuit was designed using a low-noise amplifier and a clamp type ZCT. A linear controller, the leakage current measurement part and a HVDC were used in the measurement of reference voltage. The measurement circuit of clamping voltage consisted of a surge generator and a coupling circuit. In a calibration process, measurement error of the prototype equipment was less than 3%.

Development of Equipment Measuring Insulation Resistance of High-Power Cables in Operation at Power Station (발전소에서 운전 중인 고전력 케이블의 절연저항의 변화를 감시하는 장치의 개발)

  • Um, Kee-Hong;Kim, Bo-Kyeong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.4
    • /
    • pp.159-164
    • /
    • 2016
  • In or to generate high electric power in increasing demand, power station should operate facilities to meet requirement. The scale of electric power equipment is increasing in both size and complexity. With unexpected accidents at power facilities or power stations happening, substantial socioeconomic losses in an industrial society is caused. A major cause of unexpected accidents is deterioration of dielectrics, isolating two conductors electrically. In order to detect the deterioration processes of power cables, the operation status of power cables should be monitored on a regular basis. We have invented and installed equipment at Korea Western Power Co., Ltd., located in Taean, in order to predict and prevent the deterioration status of dielectrics destruction of power cables. The main line in Y-connection to the secondary coils of transformer delivers electric power to the external devices. The equipment we developed is the one measuring insulation resistance of cables operation in on/off status with respect to the main line. We present the equipment in terms of operation and configuration of hardware side.