• 제목/요약/키워드: energy-dispersive x-ray spectroscopy (eds)

검색결과 303건 처리시간 0.023초

티타늄이 첨가된 알루미나 분산강화 동합금의 산화물 형성 거동 (Oxidation Behavior of Ti Added Alumina Dispersion Strengthening Copper Alloy)

  • 조홍래;한승전;안지혁;이재현;손영국;김광호
    • 한국재료학회지
    • /
    • 제25권4호
    • /
    • pp.202-208
    • /
    • 2015
  • Alumina dispersion strengthening copper(ADSC) alloy has great potential for use in many industrial applications such as contact supports, frictional break parts, electrode materials for lead wires, and spot welding with relatively high strength and good conductivity. In this study, we investigated the oxidation behavior of ADSC alloys. These alloys were fabricated in forms of plate and round type samples by surface oxidation reaction using Cu-0.8Al, Cu-0.4Al-0.4Ti, and Cu-0.6Al-0.4Ti(wt%) alloys. The alloys were oxidized at $980^{\circ}C$ for 1 h, 2 h, and 4 h in ambient atmosphere. The microstructure was observed with an optical microscope(OM) and a scanning electron microscope(SEM) equipped with energy-dispersive X-ray spectroscopy(EDS). Characterization of alumina was carried out using a 200 kV field-emission transmission electron microscope(TEM). As a result, various oxides including Ti were formed in the oxidation layer, in addition to ${\gamma}$-alumina. The thickness of the oxidation layer increased with Ti addition to the Cu-Al alloy and with the oxidation time. The corrected diffusion equation for the plate and round type samples showed different oxidation layer thickness under the same conditions. Diffusion length of the round type specimen had a value higher than that of its plate counterpart because the oxygen concentration per unit area of the round type specimen was higher than that of the plate type specimen at the same diffusion depth.

빔 쉐이핑을 이용한 펨토초 레이저 ITO 박막 가공 깊이 제어에 대한 연구 (Study of ablation depth control of ITO thin film using a beam shaped femtosecond laser)

  • 김훈영;윤지욱;최원석;;황경현;조성학
    • 한국레이저가공학회지
    • /
    • 제17권1호
    • /
    • pp.1-6
    • /
    • 2014
  • Indium tin oxide (ITO) is an important transparent conducting oxide (TCO). ITO films have been widely used as transparent electrodes in optoelectronic devices such as organic light-emitting devices (OLED) because of their high electrical conductivity and high transmission in the visible wavelength. Finding ways to control ITO micromachining depth is important role in the fabrication and assembly of display field. This study presented the depth control of ITO patterns on glass substrate using a femtosecond laser and slit. In the proposed approach, a gaussian beam was transformed into a quasi-flat top beam by slit. In addition, pattern of square type shaped by slit were fabricated on the surfaces of ITO films using femtosecond laser pulse irradiation, under 1030nm, single pulse. Using femtosecond laser and slit, we selectively controlled forming depth and removed the ITO thin films with thickness 145nm on glass substrates. In particular, we studied the effect of pulse number on the ablation of ITO. Clean removal of the ITO layer was observed when the 6 pulse number at $2.8TW/cm^2$. Furthermore, the morphologies and fabricated depth were characterized using a optical microscope, atomic force microscope (AFM), and energy dispersive X-ray spectroscopy (EDS).

  • PDF

엔진 마운트 브라켓용 다이캐스팅 Al-Si-Cu 합금의 미세조직과 기계적 특성 (Microstructural and Mechanical Characteristics of Al-Si-Cu Die Casting Alloy for Engine Mount Bracket)

  • 천인범;홍승표;김정석
    • 열처리공학회지
    • /
    • 제27권6호
    • /
    • pp.281-287
    • /
    • 2014
  • Microstructural and mechanical characteristics of Al-6Si-2Cu alloy for engine mount bracket prepared by gravity casting (as-cast) and die-casting (as-diecast) process have been investigated. For the microstructural characterization, the inductively coupled plasma mass spectrometry (ICP-MS), optical microscope (OM), scanning electron microscope (SEM) and electron probe microanalysis (EPMA) analyses are conducted. For the intermetallic phases, the X-ray diffraction (XRD) and energy dispersive spectroscopy (EDS) are also conducted with quantitative and qualitative analysis. Micro Vickers hardness and static tensile test are achieved in order to measure mechanical properties of alloys. Secondary dendrite arm spacing (SDAS) of as-cast and as-diecast show 37um and 18um, respectively. A large amount of coarsen eutectic Si, $Al_2Cu$ intermetallic phase and Fe-rich phases are identified in the Al-6Si-2Cu alloy. Mechanical properties of gravity casting alloy are much higher than those of die-casting alloy. Especially, yield strength and elongation of gravity casting alloy show 2 times higher than die-casting alloy. After shot peening, shot peening refined the surface grains and Si particles of the alloys by plastic deformation. The surface hardness value shows that shot peening alloy has higher value than unpeening alloy.

Porcelain의 표면코팅을 위한 Hematite 적색 안료의 특성 (Characterization of Hematite Red Pigment for Porcelain Surface Coating)

  • 김경남;박현;원일안
    • 한국재료학회지
    • /
    • 제27권4호
    • /
    • pp.206-210
    • /
    • 2017
  • In this study, an ${\alpha}-Fe_2O_3$ (hematite) coated porcelain plate was sintered in a temperature range from $1100^{\circ}C$ to $1250^{\circ}C$ using ferrous sulfate. The specimens were investigated by X-ray diffractometer (XRD), scanning electron microscopy (FE-SEM), energy dispersive spectroscopy (EDS), and UV-visible spectrophotometer. It was confirmed that ${\alpha}-Fe_2O_3$ (hematite) was densely fused to the surface at several tens of ${\mu}m$, the ${\alpha}-Fe_2O_3$ (hematite) was in the form of thin platelet and polyhedra, and no other compounds appeared in the sintering process. In the specimen coated with ${\alpha}-Fe_2O_3$ (hematite), the reflectance spectra show a red absorption band of 560-650 nm. The $L^*$ value decreased from 53.18 to 46.94 with the firing temperature. The values of $a^*$ and $b^*$ were at 19.03 and 15.25 at $1100^{\circ}C$ and gradually decreased with increasing temperature; these values decreased rapidly at $1250^{\circ}C$ to 11.54 and 7.98, respectively. It is considered that the new phases are formed by the phase transition of the porcelain plate (clay), and thus the $a^*$ and $b^*$ values are greatly influenced.

조선시대 심희수 초상화 채색 안료 분석 (Analysis of Pigment on Portraits of Sim Hui-su in Joseon Period)

  • 윤은영;장연희
    • 보존과학회지
    • /
    • 제32권4호
    • /
    • pp.571-578
    • /
    • 2016
  • 심희수 초상화 2점의 채색 안료에 대한 분석과 현미경 관찰을 통해 채색 안료의 특성을 조사하였으며 비파괴분석 결과와 비교 검토하였다. 심희수 초상화에 사용된 안료는 색상에 따라 유사한 안료를 사용한 것으로 확인되었다. 적색 안료는 진사/주, 연단을 사용하였으며, 청색 안료는 석청, 녹색 안료는 녹염동광, 백색 안료는 연백을 사용한 것으로 확인되었다. 또한 유사한 형식으로 제작된 17~18세기 조선시대 관복초상화 6점과의 채색 안료를 비교한 결과 제작 시기에 따라 차이를 보였다. 적색 안료의 경우 18세기에 제작된 초상화에서 산화철 계통의 안료가 추가적으로 사용된 특징을 보인다. 청색 안료의 차이점은 18세기 초반까지 사용되지 않았던 회청 안료가 18세기 후반에 제작된 초상화에서 확인된 점이다.

치과용 Ti-6Al-4V 합금 골 고정판 표면에 형성된 나노튜브의 부식거동 (Corrosion Behavior of Nanotube Formed on the Bone Plate of Ti-6Al-4V Alloy for Dental Use)

  • 김원기;이충환;정재헌;최한철
    • 한국표면공학회지
    • /
    • 제43권1호
    • /
    • pp.25-30
    • /
    • 2010
  • Titanium and titanium alloys are widely used for orthopedic and dental implants for their superior mechanical properties, low modulus, excellent corrosion resistance and good biocompatibility. In this study, corrosion behaviors of nanotube formed on the bone plate of Ti-6Al-4V alloy for dental use have been investigated. $TiO_2$ nanotubes were formed on the dental bone plates by anodization in $H_3PO_4$ containing 0.6 wt % NaF solution at $25^{\circ}C$. Electrochemical experiments were performed using a conventional three-electrode configuration with a platinum counter electrode and a saturated calomel reference electrode. Anodization was carried out using a scanning potentiostat (EG&G Co, Model 263A USA), and all experiments were conducted at room temperature. The surface morphology was observed using field emission scanning electron microscopy (FE-SEM) and energy dispersive x-ray spectroscopy(EDS). The corrosion behavior of the dental bone plates was examined using potentiodynamic test(potential range of -1500~2000 mV) in a 0.9% NaCl solution by potentiostat (EG&G Co, PARSTAT 2273. USA). The inner diameter of nanotube was about 150~180 nm with wall thickness of about 20 nm. The interspace of nanotube to nanotube was 50 nm. The passive region of the nanotube formed bone plates showed the broad range compared to non-nanotube formed bone plates. The corrosion surface of sample was covered with corrosion products.

LTCC 기판상에 증착한 PZT 박막의 특성 향상에 관한 연구 (Improvement of the Characteristics of PZT Thin Films deposited on LTCC Substrates)

  • 황현석;강현일
    • 한국인터넷방송통신학회논문지
    • /
    • 제12권1호
    • /
    • pp.245-248
    • /
    • 2012
  • 본 논문에서는 실리콘 기반의 기술과 차별화하여 저온동시소성세라믹 (LTCC) 기판을 이용하여 대표적 압전물질인 PZT 박막의 최적의 증착조건을 연구하였다. LTCC 기술은 실리콘 기반의 기술에 비하여 낮은 생산 단가, 높은 수율, 3차원 구조물의 용이한 제작성 등으로 인하여 센서 및 액추에이터와 같은 10 um ~ 수백 um 정도의 중규모 디바이스를 제작하는데 있어서 중요한 역할을 담당하고 있다. LTCC 기판은 NEG사의 MLS 22C 상용 파우더를 이용하여 100 um 두께의 그린쉬트를 적층하고 동시소결하여 400 um 두께로 제작하였다. 제작한 기판위에 Pt/Ti 하부전극을 증착하고 RF 마그네트론 스퍼터링 방법을 이용하여 PZT 박막의 증착조건을 연구하였다. 증착조건으로는 RF 전력과 아르곤과 산소 가스비를 가변하여 실시하였으며, XRD와 EDS를 사용하여 박막의 결정성 및 성분을 분석하였다. 실험을 통하여 얻어진 최적의 증착조건은 RF 전력 125W, 아르곤과 산소비 15:5에서 가장 우수한 특성을 나타내는 것을 확인하였다.

Adsorption Characteristics of Cd, Cu, Pb and Zn from Aqueous Solutions onto Reed Biochar

  • Choi, Ik-Won;Kim, Jae-Hoon;Lee, Soo-Hyung;Lee, Jae-Kwan;Seo, Dong-Cheol;Cho, Ju-Sik
    • 한국토양비료학회지
    • /
    • 제49권5호
    • /
    • pp.489-494
    • /
    • 2016
  • Carbon-based sorbents such as biochar and activated carbon have been proven to be cost-effective in removing pollutants containing heavy metals from wastewater. The aim of this study was using batch experiment to evaluate the adsorption characteristics of heavy metals in single-metal conditions onto reed biochar for treating wastewater containing heavy metals. The removal rates of heavy metals were in the order of Pb > $Cu{\fallingdotseq}Cd{\fallingdotseq}Zn$, showing the adsorption efficiency of Pb was higher than the other heavy metals. Freundlich and Langmuir adsorption isotherms were used to model the equilibrium adsorption data obtained from adsorption of Pb on reed biochar. For reed biochar, the Langmuir model provided a slightly better fit than the Freundlich model. Lead was observed on the biochar surface after adsorption by scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS). The main functional groups of reed biochar were aromatic carbons. Overall, the results suggested that reed biochar could be useful adsorbent for treating wastewater containing Pb.

Ag Paste bump 구조를 갖는 인쇄회로기판의 Ag migration 발생 안전성 평가 (Investigation of Ag Migration from Ag Paste Bump in Printed Circuit Board)

  • 송철호;김영훈;이상민;목지수;양용석
    • 한국재료학회지
    • /
    • 제20권1호
    • /
    • pp.19-24
    • /
    • 2010
  • The current study examined Ag migration from the Ag paste bump in the SABiT technology-applied PCB. A series of experiments were performed to measure the existence/non-existence of Ag in the insulating prepreg region. The average grain size of Ag paste was 30 nm according to X-ray diffraction (XRD) measurement. Conventional XRD showed limitations in finding a small amount of Ag in the prepreg region. The surface morphology and cross section view in the Cu line-Ag paste bump-Cu line structure were observed using a field emission scanning electron microscope (FE-SEM). The amount of Ag as a function of distance from the edge of Ag paste bump was obtained by FE-SEM with energy dispersive spectroscopy (EDS). We used an electron probe micro analyzer (EPMA) to improve the detecting resolution of Ag content and achieved the Ag distribution function as a function of the distance from the edge of the Ag paste bump. The same method with EPMA was applied for Cu filled via instead of Ag paste bump. We compared the distribution function of Ag and Cu, obtained from EPMA, and concluded that there was no considerable Ag migration effect for the SABiT technology-applied printed circuit board (PCB).

폴리머 코팅된 NiTi합금 교정선의 표면특성 (Surface Characteristics of Polymer Coated NiTi Alloy Wire for Orthodontics)

  • 조주영;김원기;최환석;이호종;최한철
    • 한국표면공학회지
    • /
    • 제43권3호
    • /
    • pp.132-141
    • /
    • 2010
  • NiTi alloy has been used for orthodontic wire due to good mechanical properties, such as elastic strength and frictional resistance, combined with a high resistance to corrosion. Recently, these wire were coated by polymer and ceramic materials for aesthetics. The purpose of this study was to investigate surface characteristics of polymer coated NiTi alloy wire for orthodontics using various instruments. Wires (round type and rectangular type) were used, respectively, for experiment. Polymer coating was carried out for wire. Specimen was investigated with field emission scanning electron microscopy(FE-SEM), energy dispersive x-ray spectroscopy(EDS) and atomic force microscopy(AFM). The phase transformation of non-coated NiTi wire from martensite to austenite occurred at the range of $14{\sim}15^{\circ}C$, in the case of coated wire, it occurred at the range of $16{\sim}18^{\circ}C$. Polymer coating on NiTi wire surface decreased the surface defects such as scratch which was formed at severe machined surface. From the AFM results, the average surface roughness of non-coated and coated NiTi wire was 13.1 nm, and 224.5 nm, respectively. From convetional surface roughness test, the average surface roughness of non-coated and coated NiTi wire was $0.046{\mu}m$, and $0.718{\mu}m$, respectively.