• Title/Summary/Keyword: energy regeneration

Search Result 356, Processing Time 0.031 seconds

Basic Static Characteristics of a Closed and a Regeneration Cycles for the OTEC System (해양온도차발전 Closed and Regeneration Cycle의 기본 정특성)

  • Cha, Sang-Won;Kim, You-Taek;Mo, Jang-Oh;Lim, Tae-Woo;Lee, Young-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.8
    • /
    • pp.1151-1157
    • /
    • 2012
  • Ocean Thermal Energy Conversion(OTEC) technology is one of the new and renewable energy that utilizes the natural temperature gradient that exists in the tropical ocean between warm surface water and the deep cold water, to generate electricity. The selection of working fluid and the OTEC cycle greatly influence the effect on the system operation, and it's energy efficiency and impacts on the environment. Working fluids of the OTEC are ammonia, R22, R407C, and R410A. In this paper, we compared boiling pressure to optimize OTEC system at $25^{\circ}C$. Also, this paper showed net-power and efficiency according to working fluids for closed cycle and regeneration cycle.

Absorption and Regeneration Characteristics of a Sorbent for Fluidized-Bed CO2 Removal Process (유동층 CO2 회수공정을 위한 흡수제의 흡수 및 재생특성)

  • Yi, Chang-Keun;Hong, Sun-Wook;Jo, Sung-Ho;Son, Jae-Ek;Choi, Jeong-Hoo
    • Korean Chemical Engineering Research
    • /
    • v.43 no.2
    • /
    • pp.294-298
    • /
    • 2005
  • Absorption and regeneration characteristics of sorbent used in a fluidized-bed process to capture $CO_2$ from flue gas have been measured in a thermo gravimetric analyzer. A sorbent Sorb NH prepared for fluidized-bed process was faster than pure $Na_2CO_3$ in absorption and regeneration reaction rate. Activation energy of apparent absorption reaction of sorbent Sorb NH was estimated as -10,100 cal/g mol and that of pure $Na_2CO_3$ as -12,200 cal/g mol. Activation energy of apparent regeneration reaction of sorbent Sorb NH was estimated as about 12,050 cal/g mol and that of pure $Na_2CO_3$ as about 11,320 cal/g mol.

A Case Study on the Application of Renewable Energy System for Urban Regeneration (도시재생을 위한 신재생에너지 적용성에 관한 사례연구)

  • Kim, Seong-Eun;Chung, Min-Hee;Park, Jin-Chul;Rhee, Eon-Ku
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.294-299
    • /
    • 2008
  • The enforcement of the Kyoto Protocol to reduce greenhouse gas is definitely a challenge we cannot avoid. Korea ranks 10th in the world and 1st among OECD countries in terms of the volume of greenhouse gas emission and is expected to join Annex I countries which have to reduce emission after 2012. For the sustainable development, we shouldn't depend upon fossil fuel energy longer. This study will provide preliminary data to developing renewable energy systems for urban generation. There are investigated a recent case study of CONCERTO projects co-funded by the European Commission and analyzed application of renewable energy systems as a urban energy source.

  • PDF

PStudy on Characteristics of Dryness Storage Tank, Component of Open-type Dehumidifying and Drying System using Solar Energy(I Experiment on Flowing Characteristics of Storage Tank for Regenerator) (태양열을 이용한 개방형 제습.건조시스템의 저장탱크 유동특성에 관한 연구(제1보 재생기용 저장탱크의 유동특성에 관한 실험))

  • Kim, J.R.;Choi, K.H.;Kum, J.S.;Kim, J.R.
    • Solar Energy
    • /
    • v.20 no.2
    • /
    • pp.1-8
    • /
    • 2000
  • The present study has been conducted to offer geometrically optimal structure of a storage tank for a regenerator, one of the components of an open-type dehumidifying and drying system using solar energy to develop an alternatives for time-limited energy such as a fossil fuel, and to decrease an environmental pollutant. Two kinds of model classified by the mixing process were suggested to estimate the amount of regeneration rate. One was the stratified-type, "case 1", a method to place an entrance in the upper part of the tank and an outlet in the lower part. The other was the mixed-type, "case 2", a method to place vice versa. Solution temperature and concentration were used to evaluate the regeneration rate. As a result, the regeneration rate was better in "case 2".

  • PDF

Study on the Contribution Ratio of Factors to Affect Regeneration Performance of a Solar Air Conditioning System (태양열 이용 냉난방 공조시스템의 재생성능에 영향을 미치는 인자의 기여율에 관한 연구)

  • Kim, B.C.;Choi, K.H.;Kum, J.S.
    • Solar Energy
    • /
    • v.20 no.1
    • /
    • pp.91-96
    • /
    • 2000
  • This study was performed to find out how much experimental factors influence on regeneration performance in a solar air conditioning system. The experimental apparatus was set up in a climate-controlled chamber where temperature and humidity could be kept constant. In order. to investigate factors' influence on the regeneration performance of the solar air conditioning system, the model experiment was done using the 600mm $\times$ 600mm black painted aluminum regenerator. The design and analysis of experiment were done by the design of experiments, especially the table of orthogonal arrays. In order to find out how much experimental factors influence on regeneration performance, the table of orthogonal arrays $L_8(2^7)$ was used. According to the results, it was found that the most influential factor to affect regeneration performance was the concentration of LiCl solution. The next influential factors were a solar radiation, an air velocity, and the temperature of LiCl solution in order.

  • PDF

Development Status of the Regeneration Inverter System for Energy Saving in DC Electric Railway (전철시스템의 에너지절약 회생인버터시스템 개발 현황)

  • Kim, Yong-Ki;Han, Moon-Seob;Yang, Young-Chul;Jang, Su-Jin
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1473-1478
    • /
    • 2007
  • In the respect of energy saving and reusing, it is necessary to reduce greenhouse gases emission and to enhance the operation efficiency in electric railway system. Recently, as the power electronics technologies are advanced, some countries have focused on the regenerative inverter to use regeneration energy on each line. When the electric tractions are stopped or slowed down, it is useful to supply the surplus energy to the power source by regenerative system, which increases its energy efficiency. Also, the generated energy can be supply to other tractions or equipments inside traction. Thus, it may help reduce construction cost of additional power plants. The purpose of this study is to describe the development status of the regenerative inverter system which suppress extra DC-line voltage and regenerate the energy instead of using a resister.

  • PDF

Development of Hybrid Excavator for Regeneration of Boom Potential Energy (작업장치 위치에너지 회생을 위한 하이브리드 굴삭기 시스템 개발)

  • Yoon, J.I.;Ahn, K.K.;Truong, D.Q.;Kang, J.M.;Kim, J.H.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.6 no.4
    • /
    • pp.1-8
    • /
    • 2009
  • Nowadays with the high fuel prices, the demands for energy saving and green emission of construction machinery have highly been increased without sacrifice of working performance, safety and reliability. The aim of this paper is to propose a new energy saving hybrid excavator system using an electro-hydraulic actuator driven by an electric motor/generator for the regeneration of potential energy. A 5 ton class excavator is analyzed, developed with the boom for the evaluation of the designed system. The hardware implementation is also presented in this paper. A control strategy for the hybrid excavator is proposed to operate the machine with a highest efficiency. The energy saving ability of the proposed excavator is clearly verified through simulation and experimental results in comparison with a conventional hydraulic excavator.

  • PDF

Effects of Regeneration Conditions on Sorption Capacity of CO2 Dry Potassium Sorbent During Carbonation (재생반응 조건이 CO2 건식 K-계열 흡수제의 흡수능력에 미치는 영향)

  • Kim, Yunseop;Park, Young Cheol;Jo, Sung-Ho;Ryu, Ho-Jung;Rhee, Young Woo;Yi, Chang-Keun
    • Korean Chemical Engineering Research
    • /
    • v.53 no.3
    • /
    • pp.333-338
    • /
    • 2015
  • In this study, we investigated carbonation-regeneration and agglomeration characteristics of dry sorbents. Experiment has been proceeded in the batch-type reactor, which is made of quartz: 0.05 m of I.D and 0.8 m in height. The sorbents that is collected at the cyclone of the carbonation reactor of continuous process were used in this study. The reactivity was studied at the various concentrations of water vapor, $N_2$ and $CO_2$ in the fluidizing gas at regeneration reaction. As a result, the reactivity increased as the regeneration temperature increased, the reactivity decreased as the concentration of water vapor increased. The absorption capacity showed the highest value in case of using $N_2$ 100% as regeneration gas. And decreased in order of $H_2O+N_2$, $CO_2$ 100% and $H_2O+CO_2$. The agglomeration characteristics were investigated according to the particle sizes and concentrations of water vapor at carbonation reaction. As a result, the particle with smaller size and higher concentration of water vapor showed the higher agglomeration characteristic.

A Study of Regeneration Reaction for Desulfurization Sorbents using Natural Manganese Ore (천연 망간 광석 탈황제의 재생 반응 특성 연구)

  • 윤여일;윤용승;김성현
    • Journal of Energy Engineering
    • /
    • v.11 no.3
    • /
    • pp.247-253
    • /
    • 2002
  • Natural manganese ore was selected as main active component for a non-zinc desulfurization sorbent used in the gas clean-up process of the integrated gasification combined cycle (IGCC) because of excellent H$_2$S removal efficiency and economical aspect . In this study, the regeneration characteristics of sorbent after desulfurization reaction were determined in a thermobalance reactor and a fixed bed reactor in the temperature range of 350~55$0^{\circ}C$. The mixed gases of oxygen and nitrogen are used as the regeneration reaction gases for manganese sorbent. According to Mn-S-O phase diagram, the manganese sorbent has a low regeneration efficiency in medium temperature due to formation of MnSO$_4$ and the regeneration temperature must be over 85$0^{\circ}C$. To improve that problem, ammonia and steam was added in regeneration mixed gases. Effect of new regeneration method was determined by XRD and difference of desulfurization through multicycle tests.

A 15kW Grid-Connected Battery Charging and Discharging System with AC Regeneration Function

  • Youn, Sun-Jae;Kim, Jun-Gu;Kim, Jae-Hyung;Won, Chung-Yuen;Na, Jong-Kuk
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.491-493
    • /
    • 2011
  • In this paper, a 15kW grid-connected battery charging and discharging system was proposed. AC regenerative device which consisted of an inverter using IGBTs and LCL filter transferred surplus power to grid. Phase locked loop(PLL) was used to resolve three-phase unbalance. AC regeneration function is able to improve the rate of energy use and the cost savings of energy is expected.

  • PDF