• 제목/요약/키워드: energy module

Search Result 1,520, Processing Time 0.043 seconds

Optimal Design of PV Module with Bypass Diode to Reduce Degradation due to Reverse Excess Current

  • Jung, Tae-Hee;Kang, Gi-Hwan;Ahn, Hyung-Keun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.15 no.5
    • /
    • pp.279-283
    • /
    • 2014
  • In this paper, we present an economical and practical standard to install a bypass diode in a thin-film PV module. This method helps to reduce heat generation and to prevent module degradation due to excess current from reverse bias. The experimental results confirm that for different numbers of solar cells, there is a relation between the excess reverse current and the degradation of solar cells in a-Si:H modules. The optimal number of solar cells that can be connected per bypass diode could be obtained through an analysis of the results to effectively suppress the degradation and to reduce the heat generated by the module. This technique could be expanded for use in high power crystalline Si PV modules.

Analysis of Effect on Freshwater Production of Vacuum Membrane Distillation Module according to Housing Leak (중공사막 진공 막증류 모듈의 하우징 누수가 담수 생산에 미치는 영향 분석)

  • Joo, Hongjin;Kwak, Heeyoul
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.3
    • /
    • pp.313-319
    • /
    • 2016
  • In this study, the performance experiment was conducted to compare the permeate flux of hollow fiber Vacuum Membrane Distillation module according to leak problem between module housing and membrane bundle. For the permeate flux performance experiment of the two Vacuum Membrane Distillation modules, the Lab-scale experimental equipment was built in the capacity of $1m^3/day$. The performance test of the two Vacuum Membrane Distillation modules were analyzed according to the feed water conditions. As a result, it was analyzed that the leak VMD module decreased about 14% of permeate flux than normal VMD module.

A Study on the Application Method of Photovoltaic in Building (PV의 건축물 적용기법에 관한 연구)

  • Lee, E.J.;Kim, H.S.
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.2
    • /
    • pp.1-10
    • /
    • 2002
  • This study is a study on the building integrated method of Photovoltaic. It was analyzed into a basic installation condition and an integrated form in this study. And it was confirmed through the 3D simulation & drawing work of an integrated situation to the real domestic building. The Photovoltaic installation of the country to an optimal efficiency for the year must be installed to the due south with an angle of thirty degrees. And also a module spacing must be more than doubled from the bottom to the top of module to prevent from efficiency falling by a shadow of photovoltaic module in a roof setting of flat roof. If Photovoltaic module is an adequate material that is a basic requirement as a building's finishing material, it's not only an efficiency of alternation with an existing finishing material but also a building's design element.

Analysis of Module Mismatch Loss in Solar PV String and Feasibility Study for Improvement Method (태양광 PV 스트링에서의 모듈 부정합 손실의 분석 및 개선 기법 타당성 연구)

  • Ahn, Hee-Wook
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.1
    • /
    • pp.58-63
    • /
    • 2009
  • In this paper, the power loss due to PV module mismatch in PV string is analyzed and a mismatch compensation method is proposed to improve the efficiency of PV system. The analysis of mismatch loss using PV model simulation reveals that the mismatch module may decrease the total efficiency because the MPPT function of power conditioner make the PV system operate at the local maximum point. The mismatch loss can be severe if the maximum power point current of mismatch module is less than that of string. The proposed compensation method which is simply implemented with a buck type converter shows the possibility to remove the mismatch loss. The effectiveness of the analysis and compensation method is verified by a prototype experiment.

Study on Surface Temperature Change of PV Module Installed on Green Roof System and Non-green Roof System (옥상녹화와 비 옥상녹화 평지붕에 설치 된 PV모듈의 표면온도 변화 고찰)

  • Yoo, Dong-Chul;Lee, Eung-Jik;Lee, Doo-Ho
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.214-219
    • /
    • 2011
  • Today, various activities to save energy are being conducted around the world. Even in our country, carbon reduction policy is being conducted for low carbon green growth and with this movement, effort to replace energy sources by recognizing the problems on environment pollution and resource exhaustion due to the indiscrete usage of fossil fuel is being made. Therefore, active study on renewable energy is in progress as part of effort to replace the energy supply through fossil fuel and solar ray industry has rapidly developed receiving big strength of renewable energy policies. The conclusion of this study measuring the surface temperature change of single crystal and polycrystalline PV module in green roof system and non-green roof system aspect are as follows. There was approximately $4^{\circ}C$ difference in PV module temperature in green roof system and non-green roof system aspect and this has the characteristic to decrease 0.5% when the temperature rises by $1^{\circ}C$ when the front side of the module is $20^{\circ}C$ higher than the surrounding air temperature following the characteristic of solar cells. It can be concluded that PV efficiency will be come better when it is $4^{\circ}C$ lower. Also, in result of temperature measurement of the module back side, there was $5^{\circ}C$ difference of PV module installed on the PV module back side and green roof system side on the 5th, $3^{\circ}C$ on the 4th, $2^{\circ}C$ on the 5th to show decreasing temperature difference as the air temperature dropped, but is judged that there will be higher temperature difference due to the evapotranspiration latent heat effect of green roof system floor side as the temperature rises. Based on this data, it is intended to be used as basic reference to maximize efficiency by applying green roof system and PV system when building non-green roof system flat roof.

  • PDF

Interaction of Multi Current Power Generation Blade (멀티 해류발전 블래이드 간섭 연구)

  • Jo, Chul-Hee;Park, Kwan-Kyu;Cho, Won-Chul
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.4
    • /
    • pp.47-54
    • /
    • 2006
  • The current power generation is very suitable renewable energy for the application to Korean western and south coastal regions where characterized as having high current speed. Being different from tidal power generation that needs tremendous dam structure to preserve water, the current power generation utilizes the ocean current flow without damaging to estuary area and its environment. There are still many areas to understand the characteristics of current power generation for the actual field installation. As designing muti module with several rotors, the interaction between rotors will occur that would affect the efficiency and RPM of each rotor. In this study, the interactions caused by gaps between rotors in multi module are studied.

A Study on the Manufacture of Single Axis Tracking Solar Power Generation System for BIPV (BIPV를 위한 단축 구동 태양광 전력 발생장치 제작에 관한 연구)

  • Cho, Jae-Cheol;Lee, Jin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.2
    • /
    • pp.335-338
    • /
    • 2012
  • Recently, the energy has been used much more than ever, but there has been many problems including atmospheric pollution. So we need alternative energy resources, which are solar heat, solar light, wind power, small water power, etc. The field, which is most popular these days, is the energy source by solar light which transform electric energy using the solar cell and it is available with many researches. In this paper, we manufactured the solar power generation system over 90W using solar module which was 9.90V for Voc, 0.93 A for Isc, 8.64 V for Vmp, 0.75 A for Imp, 6.5 W for power. System was controlled by step motor with worm gear to operate optimum condition between $0^{\circ}{\sim}70^{\circ}$ angle. This system was very effective in tracking space use because it need less space than general solar module.

Sun point detector for daylight system (태양광조명장치용 고정밀 태양위치 검출시스템)

  • Kim, Sun Ho;Kim, Byung Cheol
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.9 no.4
    • /
    • pp.26-31
    • /
    • 2010
  • Finding sufficient supplies of clean energy for future is one of the society's most important challenges according to technologies. Alternative renewable energy source such as solar energy can be substituted for exceeding human energy need. The main factor affect to solar performance is a collective intensity. To enhance intensity, suitable equipment is a solar tracker. The solar tracker consists of sun point detector module, mechanical mechanism module with actuator and control system module. This paper presents sun point detector for solar tracker of daylight system. To evaluate the detecting accuracy, an experimental device is implemented. In experimental results, the accuracy of development system has under 0.11%/0.5deg.

Design and simulation of a blanket module with high efficiency cooling system of tokamak focused on DEMO reactor

  • Sadeghi, H.;Amrollahi, R.;Zare, M.;Fazelpour, S.
    • Nuclear Engineering and Technology
    • /
    • v.52 no.2
    • /
    • pp.323-327
    • /
    • 2020
  • In this study, the neutronic calculation to obtain tritium breeding ratio (TBR) in a deuterium-tritium (D-T) fusion power reactor using Monte Carlo MCNPX is done. In addition, by using COMSOL software, an efficient cooling system is designed. In the proposed design, it is adequate to enrich up to 40% 6Li. Total tritium breeding ratio of 1.12 is achieved. The temperature of helium as coolant gas never exceed 687℃. As regards the tolerable temperature of beryllium (650℃), the design of blanket module is done in the way that beryllium temperature never exceed 600℃. The main feature of this design indicates the temperature of helium coolant is higher than other proposed models for blanket module, therefore power of electricity generation will increase.

A modeling and performance comparison of photovoltaic module (태양광모듈의 모델링 및 성능해석 결과비교)

  • So, Jung-Hun;Yu, Byung-Gyu;Hwang, Hye-Mi;Yu, Gwon-Jong;Choi, Ju-Yeop
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1128-1129
    • /
    • 2008
  • The detailed modeling method of photovoltaic (PV) module are useful to perform detailed analysis of PV array performance for changing meteorological conditions, verify actual rated power of PV system sizing and, determine the optimal design of PV system and components. This paper investigates a modeling approach of PV module performance in terms of irradiance and temperature changes and compared measured with simulated value of PV modules.

  • PDF